1 |
Porter SS, Robb IT. Increasing implant-abutment preload by thin-gold coating abutment screws. J Dent Res 1998;77:837 (IADR Abstracts)
|
2 |
Shigley J. Mechanical Engineering Design. 3ed. New York; McGraw Hill,; 1987. p. 227-252
|
3 |
Motosh N. Development of design charts for bolts preloaded up to the plastic range. J Eng Ind 1976;98:849-851
DOI
|
4 |
Shigley JE, Mischke CR. Standard handbook of machine design. 1st ed. New York; McGraw Hill; 1986. p. 23-26
|
5 |
Steri-Oss. Evaluation of TorqTite surface technology. Number TR01-1148, Yorba Linda(CA): Steri-Oss Dental Care Co; 1998
|
6 |
Jeong YT, Chung CH, Lee HT. Screw joint stability according to abutment screw materials. J Korean Acad prosthodont 2002;40 :275-286
|
7 |
Richard LB, Richard BJ,Toby K. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994;71:592-529
DOI
ScienceOn
|
8 |
Rachel SS, Walter JP, Thomas DT. Removal torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area. Int J oral Maxillofac Implants 2002;17:24-27
|
9 |
Jorneus L. Screws and cylinders in the Nobelpharma implant system. Nobelpharma News 1987;1:7
|
10 |
Andersson B, adman P, Lindvall AM. Single-tooth restorations supported by osseointegrated implants: results and experiences from a prospective study after 2 to 3years. Int J Oral Maxillofac Implants 1995;10:702-711
PUBMED
|
11 |
Ronald LS, Svenn EB. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995;10:295-302
|
12 |
Jorneus L, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated Implants. Int J Oral Maxillofac Implants 1992;7:353-359
PUBMED
|
13 |
Binon PP. Implants and Components: Entering the New Millennium. Int J oral Maxillofac Implants 2000;15:76-94
PUBMED
|
14 |
William JD. Dental Materials and their selection. 2nd Edition. 1997. p. 16-1
|
15 |
Ablowitz S, Burke JJ, Hiltz RH. Titanium industry. New York; Van Nostrand Co; 1955. p. 102-112
|
16 |
Will CM, Ronald DW, Barbara HM, Amp WM. Implant abutment screw rotations and preloads for four different screw materials and surface. J Prosthet Dent 2001;86:24-32
DOI
ScienceOn
|
17 |
Jaarda MJ, Razzoog ME, Gratton DG. Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws. Implant Dent 1994;3:17-21
DOI
PUBMED
ScienceOn
|
18 |
Avivi-Arber L, Zarb GA. Clinical effectiveness of implant-supported single tooth replacement. Int J Oral Maxillofac Implant 1996;11:311-321
|
19 |
Binon P. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994;9;48-63
|
20 |
Charles JG, Joseph YKK, Kitichai R. Clinical complications of osseintegrated implants. J Prosthet Dent 1999;81:537-552
DOI
ScienceOn
|