• 제목/요약/키워드: gold alloy

검색결과 233건 처리시간 0.028초

각종매몰재와 주조 금속에 따른 주조관의 적합도에 관한 실험적 연구 (Comparing Fitness of Casting Crowns with Various Investments and Casting Metals)

  • 이병기;차성수;김원태
    • 대한치과기공학회지
    • /
    • 제5권1호
    • /
    • pp.13-17
    • /
    • 1983
  • The experimental investication wax performed to study fitness of casting crowns with various investment widely used in Korea. 36 wax patterns were invested and casted according to the regular casting method. The result were as follow : 1. Casting with cristobalite investments of Shofu were seen apart, 0.04mm the tightest space in the linguo and bucco-cervical margin. And the largest deviation, 0.1mm was shown in the central groove 0.1mm was shown in the central groove area of occlusal surface(Jensen Metal) 2. Casting with cristobalite investments of kerr were seen apart, 0.04mm the tightest space in the linguo and bucco-cervical margin And the largest deviation, 0.09 was shown in the central groove area of occlusal surface(Jensen Metal) 3. Casting with Quartz investments of G-C were seen apart, 0.04mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.1mm was shown in the central groove area of occlusal surface(Jensen Metal) 4. Casting with cristobalite investments of shofu were seen apart, 0.01mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.03mm was shown in the central groove of occusal surface(Bo-sung A type gold alloy) 5. Casting with cristobalite investments of kerr showed the best fintness in linguo-cervical margin. And the largest deviation, 0.02mm was shown in the central groove area of occlusal surface(Bosung A type gold alloy) 6. Casting with Quartz investments of G-C were Seen apart, 0.02mm the tightest space in the linguo-cervical margin, And the largest deviation, 0.04mm was shown in the central groove area of occlusal surface(Bo-sung A type gold alloy) 7. Casting with cristobalite investments of shofu were seen apart, 0.01mm the tightest space in the linguo-cervical margin. And the largest deviation, 0.08mm was shown in the buccal cusp area of occlusal surface(Bo-sung B type gold alloy) 8. Casting with cristobalite investments of kerr shown the best fitness in linguo-cervical margin. And the largest deviation, 0.04mm was shown in the central groove atea of occlusal surface(Bosung B type gold alloy) 9. Casting with Quartz investments of G-C were seen apart, 0.03mm the tightest space in the linguo-cervical margin. And the largest deviation, 0.04mm was shown in the central groove area of occlusal surface(Bo-sung B type gold alloy) 10. Casting with cristobalite investments of kerr shown the best fitness and Bo-sung A type gold alloy showed the best fitness.

  • PDF

법랑질에 의한 수종의 간접복합레진의 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF INDIRECT COMPOSITE RESINS AGAINST HUMAN ENAMEL)

  • 이현정;전영찬;정창모;정희찬
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.611-620
    • /
    • 2007
  • Statement of problem: Second-generation indirect composite resins have been improved flexural strength, compressive strength, hydrolytic degradation resistance, wear resistance compared to first-generation indirect composite resins, but there are still some problems as hydrolysis and low wear resistance. Some manufacturers claim that wear resistance of their materials has been improved, but little independent study has been published on wear properties of these materials and the properties specified in the advertising materials are largely derived from in-house or contracted testing. Purpose: This study was to evaluate the wear of indirect composite resins (SR Adore, Sinfony, Tescera ATL) and gold alloy against the human enamel. Material and method: Extracted human incisors and premolars were sectioned to $2{\times}2{\times}2mm$ cube and embedded in the clear resin and formed conical shaped antagonist to fit the jig of pin-on-disk tribometer. Total 20 antagonists were stored in distilled water. Five disk samples, 24mm in diameter and 1.5mm thick, were made for each of three groups of indirect composite resins and gold alloy group, and polished to #2,000 SiC paper on auto-polishing machine. Disk specimens were tested for wear against enamel antagonists. Wear test were conducted in distilled water using a pin-on-disk tribometer under condition (sliding speed 200rpm contact load 24N, sliding distance 160m). The wear of the enamel was determined by weighing the enamel antagonist before and after test, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear mechanisms. Statistical analysis of the enamel wear volume, wear track depth and wear tract width of disk specimens were accomplished with one-way ANOVA and the means were compared for significant differences with Scheffe's test. Results: 1. The enamel wear was most in gold alloy, but there were no statistically significant differences among all the groups (P>.05). 2. In indirect composite resin groups, the group to make the most shallow depth of wear tract was Sinfony, followed by Tescera ATL, SR Adoro (P<.05). Gold alloy was shallower than Sinfony, but there was no statistically significant difference between Sinfony and gold alloy (P>.05). 3. The width of wear tract of SR Adore was larger than the other groups (P<.05), and there were no statistically significant differences among the other groups (P>.05). 4. SEM analysis revealed that Sinfony and gold alloy showed less wear scars after test, Tescera ATL showed more wear scars and SR Adore showed the most. Conclusion: Within the limits of this study, Sinfony and gold alloy showed the least wear rates and showed similar wear patterns.

백색 5K Au-Ag-In 합금재의 인듐 첨가량에 따른 물성 변화 (Properties of the White 5K Au-Ag-In Alloys with Indium Contents)

  • 송정호;송오성
    • 한국재료학회지
    • /
    • 제27권7호
    • /
    • pp.381-385
    • /
    • 2017
  • In order to replace 14K white gold alloys, the properties of 5K white gold alloys (Au20-Ag80) were investigated by changing the contents of In (0.0-10.0 wt%). Energy dispersive X-ray spectroscopy (EDS) was used to determine the precise content of alloys. Properties of the alloys such as hardness, melting point, color difference, and corrosion resistance were determined using Vickers Hardness test, TGA-DTA, UV-VIS-NIR-colorimetry, and salt-spray tests, respectively. Wetting angle analysis was performed to determine the wettability of the alloys on plaster. The results of the EDS analysis confirmed that the Au-Ag-In alloys had been fabricated with the intended composition. The results of the Vickers hardness test revealed that each Au-Ag-In alloy had higher mechanical hardness than that of 14K white gold. TGA-DTA analysis showed that the melting point decreased with an increase in the In content. In particular, the alloy containing 10.0 wt% In showed a lower melting temperature (> $70^{\circ}C$) than the other alloys, which implied that alloys containing 10.0 wt% In can be used as soldering materials for Au-Ag-In alloys. Color difference analysis also revealed that all the Au-Ag-In alloys showed a color difference of less than 6.51 with respect to 14K white gold, which implied a white metallic color. A 72-h salt-spray test confirmed that the Au-AgIn alloys showed better corrosion resistance than 14K white gold alloys. All Au-Ag-In alloys showed wetting angle similar to that of 14K white gold alloys. It was observed that the 10.0 wt% In alloy had a very small wetting angle, further confirming it as a good soldering material for white metals. Our results show that white 5K Au-Ag-In alloys with appropriate properties might be successful substitutes for 14K white gold alloys.

Corrosion of Dental Au-Ag-Cu-Pd Alloys in 0.9 % Sodium Chloride Solution

  • Chiba, Atsushi;Kusayanagi, Yukiharu
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.19-22
    • /
    • 2005
  • Two Au-Ag-Cu-Pd dental casting alloys (Au:12% and 20%) used. The test solutions used 0.9 % NaCl solution (isotonic sodium chloride solution), 0.9 % NaCl solution containing 1 % lactic acid, and 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_2S$. The surface of two samples in three sample solutions was not natural discoloration during one year. The alloy containing 12 % gold was easily alloyed and the composition was uniform comparing with the alloy containing 20 % gold. The rest potentials have not a little effect after three months. The kinds of metals could not definitely from the oxidation and reduction waves of metal on the cyclic voltammograms. The dissolutions of gold and palladium were 12 % Au sample in the 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_{2}S$. The pH of solution had an affect on dissolution of copper, and sulfur ion had an affect on dissolution of silver. The copper dissolved amount from 20 % gold sample was about 26 times comparing with that of 12 % gold sample in the 0.9 % solution containing 1 % lactic acid. Corrosion products were silver chloride and copper chloride in NaCl solution, and silver sulfide and copper sulfide in NaCl solution containing $Na_{2}S$.

이종금속간의 결합방법에 따른 결합강도에 관한 비교 연구 (Comparative analysis on mechanical properties of gold and Co-Cr dental alloys due to joining methods)

  • 박성규;최부병;권긍록
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.75-86
    • /
    • 2003
  • The purpose of this study was to evaluate their mechanical properties after laser-welding or soldering of precious and non-precious dental alloys. For this study, 30 Co-Cr alloy specimens, 15 gold alloy specimens, 15 palladium alloy specimens were casted and seperated on the middle area. 15 sperated Co-Cr specimens and 15 seperated gold alloy specimens were laser welded (GW Group). 15 sperated Co-Cr specimens and 15 sperated gold alloy specimens were soldered by coventional soldering method (GS Group). 15 sperated Co-Cr specimens and 15 seperated palladium alloy specimens were laser welded (PW Group). 15 sperated Co-Cr specimens and 15 sperated palladium alloy specimens were soldered by coventional soldering method (PS Group). Tensile strength, 0.2% yield strength, % elongation were recorded in nine specimens of each group. Bending strength were record in six specimens of each group. These data for four groups were subjected to a two-way analysis of variance(ANOVA). The fracture locations, fractured surfaces were examined by SEM(scanning electron microscope). The results were as following: 1) In the same alloy combination, the tensile strength and 0.2% yield strength and of the laser welded group with same metal combination were significantly less than soldered groups(p<0.05). 2) In the combination of Co-Cr/Palladium, the bending strength of laser welded group were significantly less than that of soldered groups(p<0.05). In the combination of Co-Cr/Gold, the bending strength of laser welded group were significantly higher than that of soldered groups(p<0.05). 3) In the same method of joint, the tensile strength and 0.2% yield strength and bending strength of the Co-Cr/gold were significantly higher than Co-Cr/palladium(p<0.05). 4) There was no significantly statistical difference between each group in the % elongation(p>0.05). 5) The fracture of the laser welded specimens occured in the welding area and a large void was observed at the center of the fracture surface. 6) The fracture of the soldered specimens occured also inthe soldered area and many porpsities were showed at the fracture sites.

치과용 금합금에 대한 금속 프라이머 처리와 열순환 처리가 교정용 브라켓의 전단결합강도에 미치는 영향 (Effect of metal primer and thermocycling on shear bonding strength between the orthodontic bracket and gold alloy)

  • 이영기;차정열;유형석;황충주
    • 대한치과교정학회지
    • /
    • 제39권5호
    • /
    • pp.320-329
    • /
    • 2009
  • 치과용 금합금에 교정용 브라켓 접착 시 금속 프라이머와 열순환 처리가 전단결합강도에 미치는 영향을 알아보기 위하여 80개의 치과용 금합금 시편을 샌드블라스팅만 처리한 군과 3종류의 금속 프라이머(Alloy Primer, Metaltite, V-Primer)처리를 시행한 군으로 분류하고, 이를 열순환 처리 시행 여부에 따라 모두 8개 군으로 분류하였다. 만능물성 시험기를 사용하여 브라켓의 전단결합강도를 측정하고, modified ARI (Adhesive Remnant Index) scores를 통해 브라켓 접착면의 파절 양상을 평가하였다. 열순환 처리 미시행 시에는 금속 프라이머의 적용 시 샌드블라스팅만 단독으로 처리한 경우에 비하여 통계적으로 유의성 있는 전단결합강도의 증가가 있었다 (p < 0.05). 열순환 처리를 시행한 군에는 금속 프라이머의 처리에 의한 전단결합강도의 변화는 유의한 차이가 없었다 (p > 0.05). 금속 프라이머를 적용한 경우 열순환 처리 미시행 시에는 파절 양상이 브라켓과 접착제 계면에서의 파절 발생 빈도가 높았으나, 열순환 처리 시행 시에는 각 군 간 파절 양상에 유의한 차이가 없었다. 이상의 결과로 금속 프라이머의 적용이 치과용 금합금에 대한 교정용 브라켓 접착 시 초기 접착 강도에서는 유의성 있는 결합력의 증가를 보이나, 열순환 처리 시행 후에는 결합 강도에서는 유의한 차이가 없는 것으로 나타나 금속 프라이머에 의한 결합력 증가가 감소하는 것으로 생각한다.

치아에 잔존하는 치과재료의 성분분석을 통한 개인식별에의 응용 (Analysis of Residual Dental Materials Existing on the Teeth and Its Application to Individual Identification)

  • 윤중교;최종훈;김종열
    • Journal of Oral Medicine and Pain
    • /
    • 제23권2호
    • /
    • pp.193-209
    • /
    • 1998
  • In identifying bodies that are severely decayed or damaged, methods using fingerprints and various biochemical tests are known to have its limits. To overcome this, forensic odontological method which is based on the analysis of the cranium, tooth and dental restoration is used to enhance the accuracey of individual identification. For this reason, I have come to analysis of the dental materials that exists between the teeth that is perceived to have been previously restored and the one adjacent to it. By analyzing the constituents of gold crown-restored, non-precious metal-restored, gold inlay-restored and amalgam -restored teeth, and adjacent teeth using EDX(energy dispersive X-ray microanalysis) which was invented to analyze very small amount of elements, the nature of the restoration could be predicted and the results obtained were as follows. 1. Some of constitute of gold alloy was extracted from residual cement of gold crown restoration, but that was not extracted from the restored tooth and the one adjacent to it. 2. Some of constituents of non-precious metal alloy was extracted both in the residual cement on the tooth with no-precious metal restoration and in the tooth with the restoration itself. However, none of its constituents were found in the tooth adjacent to it. 3. Some of constituents of gold alloy were found in the residual cement of gold inlay, but they were not found in the restored tooth and the adjacent tooth. 4. Some of constituents of amalgam alloy were found both in tooth restored with amalgam and in the adjacent tooth. From the results obtained above, it is possible to utilize the data obtained from analyizing residual dental materials in a more effective way. This data compensates for the lost data due to any harm done to the restorations prior to individual identification and further enhances the accuracy. Therefore, it could be concluded that this process of analyzing residual dental materials could be beneficial to individual identification in the area of forensic odontoldogy.

  • PDF

Studies on the Interaction of Alkyl Thiophosphinate with Precious Metals

  • 김동수
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권4호
    • /
    • pp.321-325
    • /
    • 1995
  • Adsorption mechanisms of diisobutyl dithiophosphinate (DIBDTPI) and diisobutyl monothiophosphinate (DIBMTPI) on gold and gold-silver alloys (80:20 and 50:50) have been studied. The adsorption mechanisms on gold-silver alloys can be explained by the EC mechanism involving an electron transfer step and a chemical reaction step. Thus, the adsorption should be controlled by the E of the electrochemical oxidation of the electrode involved and the pK of the metal collector complex. Both di- and mono- thiophosphinate adsorb on 50:50 Au-Ag alloy at lower potential than on 80:20 Au-Ag alloy surface. There are no significant differences between the reactivities of DIBDTPI and DIBMTPI with precious metals except that the dithio- compound can be oxidized to dimer on gold at high potentials, while the monothio- homologue cannot. In this regard, DIBDTPI may be a better surface active reagent for pure gold than DIBMTPI.

Ni-Cr합금과 도재간의 결합력에 gold-based bonding agent가 미치는 영향 (The effect of the gold based bonding agents on the bond between Ni-Cr alloys and ceramic restorations)

  • 이정환;주규지
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.213-223
    • /
    • 2007
  • The success of a porcelain fused to metal (PFM) restoration depends upon the quality of the porcelain-metal bond. The adhesion between metal substructure and dental porcelain is related to the diffusion of oxygen to the reaction layer formed on cast-metal surface during firing. The purposed of this investigation was to study the effects of gold based bonding agent on Ni-Cr alloy-ceramic adhesion between porcelain matrix, gold based bonding agent and metal substructure interface. gold based bonding agent have been applied as an intermediate layer between a metal substructure and a ceramic coating. gold based bonding agent(Aurofilm NP, Metalor, Swiss) was applied on Ni-Cr alloy surface by four method. Surfaces only air abraded with 110${\beta}\neq$ Al2O3 particles were used as control. metal ceramic adhesion was evaluated by a biaxial flexure test(N=5) and volume fraction of adherent porcelain was determined by SEM/EDS analysis. Result of this study suggest that the layering sequence of gold based bonding agent is very important and can improve porcelain adherence to PFM.

  • PDF

Phase Transformation and Mechanical Properties of 14 K White Gold Alloys by Heat Treatments

  • 윤돈규;서진교;안용길;신소라;한동석;박종완
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.283-283
    • /
    • 2013
  • Because of beautiful glossy and color, the value of gold leverage is very high in Europe. To improve the quality of gold alloys, we performed heat treatment on 14 K white gold alloys by variously changing age-hardening conditions. Age-hardening behavior and the related phase transformation changes were studied to elucidate the hardening mechanism of 14 K white gold alloy. For solid solution treatment [ST], casted gold alloy specimens were treated at high temperature ($750^{\circ}C$) for 30 minutes, and the specimens dropped to water to quench them. For Age-hardening treatment [AT], the specimens were treated at various temperatures ($250{\sim}300^{\circ}C$). After the heat treatment, we observed the phenomenon to increase hardness from 126 Hv to 166 Hv by Vicker's hardness tester. Through electron probe micro-analysis (EPMA) mapping analysis, we investigated that irregular particles were changed uniformly. In the SEM and OM images, two phases of matrix and particle-likestructures were observed, and the precipitation of these elements from the matrix progressed during age-hardening. By transmission electron microscope and X-ray diffraction observation, it was revealed that the formation of the Au3Cu superstructure contributed to the age-hardening at $270^{\circ}C$ in the gold alloy. After the heat treatment, this analysis shows that casted gold alloys were to improve hardness and to moderate surface defects at specific temperatures and duration.

  • PDF