• 제목/요약/키워드: gold alloy

검색결과 233건 처리시간 0.03초

Comparison of retention forces with various fabrication methods and materials in double crowns

  • Guven, Melahat Celik;Tuna, Meral;Bozdag, Ergun;Ozturk, Gizem Nur;Bayraktar, Gulsen
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.308-314
    • /
    • 2017
  • PURPOSE. The purpose of this study was to analyze the retention force changes and wear behaviours of double-crown systems over long-term use. MATERIALS AND METHODS. Ten groups, each consisting of six samples, were evaluated. Specifically, casting gold alloy primary crown - casting gold alloy secondary crown (AA), laser sintering primary crown - laser sintering secondary crown (LL), casting Cr alloy primary crown - casting Cr alloy secondary crown, (CC) zirconia primary crown - electroformed secondary crown (ZA), and CAD/CAM titanium alloy primary crown - CAD/CAM titanium alloy secondary crown (TT) groups were evaluated at cone angles of $4^{\circ}$ and $6^{\circ}$. The samples were subjected to 5,000 insertion-separation cycles in artificial saliva, and the retention forces were measured every 500 cycles. The wear levels were analyzed via SEM at the beginning and end of the 5,000 cycles. RESULTS. In all samples, the retention forces increased when the conus angle decreased. The highest initial and final retention force values were found in the $LL-4^{\circ}$ group (32.89 N-32.65 N), and the lowest retention force values were found in the $ZA6^{\circ}$ group (5.41 N-6.27 N). The ZA groups' samples showed the least change in the retention force, and no wear was observed. In the other groups, wear was observed mostly in the primary crowns. CONCLUSION. More predictable, clinically relevant, and less excursive retention forces can be observed in the ZA groups. The retention force values of the LL groups were statically similar to those of the other groups, except the ZA groups.

도재소부용 금합금에서 인듐, 주석 첨가가 금속-도재계면 특성에 미치는 영향 (Effects of Indium and Tin on Interfacial Property of Porcelain Fused to Low Gold Alloys)

  • 남상용;곽동주;정석민
    • 대한치과기공학회지
    • /
    • 제23권1호
    • /
    • pp.31-43
    • /
    • 2001
  • This study was performed to observe the micro-structure change of surface, behavior of oxide change of element, the component transformation of the alloy and the bonding strength between the porcelain interface in order to investigate effects of indium, tin on interfacial properties of porcelain fused to low gold alloy. Hardness of castings was measured with a micro-Vicker's hardness tester. The compositional change of the surface of heat-treated specimen was analyzed with an EDS and an EPMA. The interfacial shear bonding strength between alloy specimen and fused porcelain was measured with a mechanical testing system(MTS 858.20). The results were as follows: 1) The hardness value of alloy increased as increasing amount of indium addition. 2) The formation of oxidation increased as increasing indium and tin contents after heat treatment. 3) Diffusion of indium and tin elements increased as increasing indium and tin contents in metal-porcelain surface after porcelain fused to metal firing. 4) The most interfacial shear bonding strength was increased as increasing a composition of adding elements, and a heat-treatment time, and an oxygen partial pressure. From the results of this study it was found that the addition of alloying elements such as indium and tin increase hardness of as-cast alloy, produce surface oxide layer of adding elements by heat-treatment which may improve interfacial bonding strength between alloy and porcelain.

  • PDF

자연치아 및 치과용 합금에 대한 도재표면 마모에 관한 실험적 연구 (An Experimental Study on Wear of Porcelain Surface to Natural Teeth and Crown Metal Alloys)

  • 이능수
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.47-54
    • /
    • 1981
  • Dental porcelains are widely used for restorative material because of its excellent esthetic property. But according to contact with natural teeth or metal in oral cavity, the porcelain may be worn and may effect on masticatory physiology and prosthetic function. The purpose of this experiment was to study on wear of porcelain surface which treated in different method. Using the abrasion device which was designed and constructed by myself, the different porcelain surface were abraded by gold alloy, nickel-chrome alloy and natural teeth in order to compare roughness. Results were as follows. 1. The group of porcelain abraded by gold alloy showed less surface roughness change (t=2.92, p<0.05), and the group of porcelain abraded by natural teeth had high surface roughness. change (t=6.84, p<0.05). 2. According to the method of surface treatment, the surface roughness were very significant (F=9.12, p<0.05). 3. After abrading, the porcelain surface roughness change was very significant (F=54.49, p<0.05). 4. There was no significant between surface treatment method and the kind of abrading materials. (F=1.01, p>0..05). 5. The group of natural glazing had the most smooth surface ($2.1{\pm}1.13{\mu}m$).

  • PDF

고대 금동유물의 금도금(金鍍金) 피막(被膜)에 관한 연구 (A Study on the Gold Film Coated on the Ancient Gilt Bronze)

  • 임선기;강성군
    • 보존과학회지
    • /
    • 제1권1호
    • /
    • pp.60-79
    • /
    • 1992
  • In relation to the scientific conservation treatment of ancient gilt bronze, the gold film coated on the bronze excavated from Hwangnam Great Tomb of Old Silla Kingdom(A. D. 5C) was studied in the view of coating technology and metallurgy of bronze. The uniform and dense gold film containing $2.44\sim12.40%$ of Hg with the thickness of $5.99\sim12.97{\mu}m$ was found to be coated on the bronze objects by amalgam coating method. On silver objects, the film with the thickness of $19.96{\mu}m$ was coated also continously and uniformly with gold by the same method. The bronze objects was fabricated by forging technique and contained almost $4.7\sim11.5%$ of Pb. Its microstructure was $\alpha-phase$ solid solution including Pb segregation in the matrix. The amount of $0.4\sim2.0%$ Zn was added in the bronze for the purpose of easy fabricating of Cu alloy. Based on the data studied, the gold film on bronze sample was reproduced by amalgam coating method and compared with the ancient gold film.

  • PDF

치과용 합금의 표면 처리가 글라스아이오노머 시멘트와 폴리카르복실레이트 시멘트의 결합력에 미치는 영향 (INFLUENCE OF SURFACE TREATMENTS OF DENIAL ALLOYS ON BOND STRENGTH OF GLASS IONOMER AND POLYCARBOXYLATE CEMENT)

  • 이헌우;우이형;임호남;최부병
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.125-142
    • /
    • 1996
  • Bond strength of four different cements to dental casting alloys which were treated with #600 emery, tin-plating, and $50{\mu}m$ sandblasting were evaluated. The alloy specimens were Type III Gold alloy(Degulor C), Palladium-Silver alloy(Pors on 4), Nickel-Chromium(Rexillium III) alloy, which were embedded in acrylic resin disc. The specimens were treated with #600 emery and tin plating, #600 emery and sandblasting, then bonded using Fuji I, Ketac Cem(Glass ionomer cements), Poly F, Livcarbo(Polycarboxylate cements). The specimens were immersed in water for 24 hours and shear bond strengths were evaluated by Instron Machine. Tin plated, sandblasted, and debonded alloy surfaces were observed using scanning electron microscope. On the basis of this study, the following conclusions could be drawn. 1. In the tin plated alloy group, increase in bond strength of glass ionomer cements was statistically insignificant. 2. In the tin plated alloy group, increase in bond strength of polycarboxylate cements was statistically significant, except nickel-chromium alloy. 3. Sandblasted alloy group showed higher bond strength than that of tin-plated alloy group.

  • PDF

도재 열처리 과정중에 나타나는 도재용 귀금속 합금 표면의 성분 원소 변화에 관한 연구 (A Study on the Surface Pelmental Change of the Precious Procelain alloy during Porcelain degassing procedure)

  • 김광남;조성암
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.27-31
    • /
    • 1986
  • The purpose of this study was to discover the elemental change of the tracemetal surface of the precious porcelain alloy. The alloy was degudent H. For this purpose, the following experiment was made the analysis of the elemental change of the surface precious gold porcelain alloy were done by EDXA, and EPMA. The result is as follows, The Indium was transported to the alloy surface and its segregation to within a few microns of the porcelain-metal interface.

  • PDF

백색금 합금용 모합금의 실리콘 함량에 따른 물성변화 (Properties of the Master Alloys for White Gold Products with Silicon Contents)

  • 송정호;노윤영;이현우;최민경;송오성
    • 한국재료학회지
    • /
    • 제25권2호
    • /
    • pp.90-94
    • /
    • 2015
  • We prepared 8 samples of non-silver and silver-added master alloys containing silicon to confirm the existence of nickel-silicides. We then prepared products made of 14K and 18K white gold by using the prepared master alloys containing 0.25, 0.35, and 0.50 wt% silicon to check for nickel release. We then employed the EN 1811 testing standard to investigate the nickel release of the white gold products, and we also confirmed the color of the white gold products with an UV-VIS-NIR-color meter. We observed $NiSi_x$ residue in all master alloys containing more than 0.50 wt% Si with EDS-nitric acid etching. For the white gold products, we could not confirm the existence of $NiSi_x$ through XRD after aqua-regia etching. In the EN 1811 test, only the white gold products with 0.25 wt% silicon master alloys successfully passed the nickel release regulations. Moreover, we confirmed that our white gold products showed excellent Lab indices as compared to those of commercial white gold ones, and the silver-added master alloys offered a larger L index. Our results indicate that employing 0.25 wt% silicon master alloys might be suitable for white gold products without nickel-silicide defects and nickel release problems.

저품위 금합금의 PbO와 CaO를 이용한 건식 정련 공정 (Pyrometallurgy Process for a Low Graded Gold Alloy with PbO and CaO)

  • 송정호;송오성
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.608-613
    • /
    • 2017
  • 본 연구에서는 저품위인 35wt% 금합금에 대해 80.0wt% 이상의 Au를 얻기 위한 건식 정련 공정을 제안하였다. Au35wt%-Ag5wt%-Cu60wt%의 조성을 가진 금합금에 대해 PbO/(PbO+CaO)의 혼합비를 각각 0~1로 변화시키고 플럭스/금합금의 무게비는 1/2로 하여 $1200^{\circ}C$-5시간의 열처리를 진행하였다. 이때 공정 전, 후 시료의 조성 변화는 energy dispersive X-ray spectroscopy(EDS)로 확인하고, 공정이 완료된 후 분리된 플럭스 금속 원소 성분은 time of flight secondary ion mass spectromerty(ToF-SIMS)로 확인하였다. EDS분석 결과 플럭스의 비율이 1(PbO 단일)인 경우 Au의 함량이 35.0wt%에서 86.7wt%로 가장 크게 향상되었고, 다른 플럭스 조성의 경우도 84wt% 이상으로 정련이 가능하였다. 또한 2/3 혼합비의 플럭스에서 Ag가 플럭스부로 빠져나가는 손실이 가장 적었다. 플럭스부의 ToF-SIMS 분석 결과 플럭스의 비율이 1, 0 일 때 $Au^+$의 특성 피크의 강도가 각각 349, 37로 측정되었다. Au의 손실을 고려하였을 때 CaO 단일 플럭스의 사용이 더 유리할 수 있었으나, 이 정도의 신호강도는 무시할 수 있는 정도로 판단되었다. 따라서 혼합플럭스를 이용한 건식 열처리를 통해 효과적인 금의 정련이 가능하여 경제적인 습식제련의 전처리 공정으로 사용될 수 있음을 확인하였다.

고대신라의 금속기술 연구 (A Study of Metal Technology in Ancient Silla Dynasity)

  • 강성군;조종수
    • 한국표면공학회지
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 1975
  • The crorosion film of gilt bronz, silver and iron objects, which were excaved from Ancient Tomb of Silla Dynasty, was removed by the electrolytic reduction process. These metallic objects were mainly investigated for microstructure, designs and gilting film etc. Most iron objects might be made by hot forging process. The cold extrusion technique might be used for gold and silver objects, in addition to an amalgam method might be applied for the gilting Au film on Cu-alloy surface. For the gilting on glass surface, first, a Cu alloy was cladded on glass , next, Au-film was obtained on the Cu-ally by the amagum method.

  • PDF

블리스터 시험법을 이용한 열증착 금박막의 기계적 성질 측정 (Measurement of Mechanical Properties of a Thermally Evaporated Gold Film Using Blister Test)

  • 문호정;함순식;엄윤용;조영호
    • 대한기계학회논문집A
    • /
    • 제20권3호
    • /
    • pp.882-890
    • /
    • 1996
  • Mechanical properties, including Young's modulus, residual stress and rupture strength, of a thermally evaporated gold film have been measured form a blister test. In a theoretical study, the priniple of minimum potential energy and that of virtual work have been applied to the pressurized circular membrane problem, and load-deflection relations have been derived for typical membrane deflection mode of spheroidal shape. In an experimental study, circular gold membranes of 4800 A-thickness and 3.5mm diameter were fabricated by the silicon electropolishing technique. Mecahnical properties of the thin gold films were deduced from the load-deflection curves obtained by the blister test, Young's moduli, obtianed from blister test, have been in the range of 45-70 GPa, while those of bulk gold have been in the range of 78-80 GPa. Residual stresses in the evaporated gold films have been measured as 28-110MPa in tension, The rupture strength of the gold film has turned out to be almost equal to that of dental gold alloy (310-380MPa). It has been demonstrated that the present specimen fabrication method and blister test apparatus have been effective for simultaneous measurement of Young's modulus, residual stress and repture strength of thin solid films. Especially, the electropolishing technique employed here has provided a simple and practical way to fabricate thin membranes in a circular or an arbitrary shape, which could not be obtained by the conventional anisotropic silicon mecromachining technique.