A Study on Manufacturing Techniques and Conservation Treatment for Yongjam, Ceremonial Hairpin with a Dragon-shaped Engraving in 17th Century - Focusing on Yongjam of the Clothes Worn by Oejae Yi Dan-ha and His wife, National Folklore Cultural Heritage No.4 - (17세기 대례용 용잠의 제작기법 조사와 보존처리 - 국가민속문화재 제4호 외재 이단하 내외옷 용잠을 중심으로 -)

  • Ryu, Dongwan;An, Boyeon;Lee, Ryangmi;Lee, Jaesung;Park, Yeonghwan;You, Harim
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.270-281
    • /
    • 2021
  • The Yongjam of Oejae, Yi Dan-ha's wife, is an ornamental hairpin with a dragon-shaped engraving; designated as National Folklore Cultural Heritage No. 4. It is also a component of the ceremonial costume, and an artifact of great value as it clearly identifies the position of the wearer and the period of this artifact. The Yongjam has been well preserved in general; however, various pollutants and corrosive products have affected the engraved patterns, requiring conservation treatment. Furthermore, a non-destructive analysis was conducted to identify the components of the materials and the manufacturing techniques used in the ornament. The Yongjam is hollow inside to reduce its weight when placed in the hair and has a color contrast of gold, red, and black. The decorative part and the body were made separately. That is, the body was made from an alloy of copper, silver, and zinc, and its joint was elaborately connected without any overlaps. In the decorative part, different alloy ratios were identified in the dragon's face, beard, horn, body, and fin. Further, for the dragon's face with its delicate patterns, an alloy of silver and copper was used, likely to make the face appear as realistic as possible.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

Characterization of the Stress in the Luting Cement layer Influenced by Material Properties of Full Veneer Crown (전부피개관의 물성과 시멘트의 물성이 시멘트 내부의 응력에 미치는 영향)

  • Lee, Jun-Young;Lee, Kyu-bok;Lee, Chung-Hee;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The objective of this study was to test the effects of crown material, cement type, the direction in which stress is applied and distribution of luting cement that might lead to cement microfracture using 2D Finite Element Method. Twenty three finite element models with a chamfer margin configuration were generated for a mandibular first molar. Crown models exhibited four crown materials: type 3 gold alloy, Ni-Cr alloy, ceramic and composite resin, and two luting cements: zinc phosphate and glass ionomer cements with a thicknesses of $70{\mu}m$. Modeled crowns were loaded axially or obliquely at unit load of 1 N. Areas and levels of stress concentrations within the cement were determined. Stress in the cement layer at the margins of crowns were higher than those in the area away from the margin. Stress under oblique loads were much higher than under axial load. The stiffer crown material produced higher stress and similarly, higher stress were found in cements with the greater Young's modulus.

Solderability of thin ENEPIG plating Layer for Fine Pitch Package application (미세피치 패키지 적용을 위한 thin ENEPIG 도금층의 솔더링 특성)

  • Back, Jong-Hoon;Lee, Byung-Suk;Yoo, Sehoon;Han, Deok-Gon;Jung, Seung-Boo;Yoon, Jeong-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.83-90
    • /
    • 2017
  • In this paper, we evaluated the solderability of thin electroless nickel-electroless palladium-immersion gold (ENEPIG) plating layer for fine-pitch package applications. Firstly, the wetting behavior, interfacial reactions, and mechanical reliability of a Sn-3.0Ag-0.5Cu (SAC305) solder alloy on a thin ENEPIG coated substrate were evaluated. In the wetting test, maximum wetting force increased with increasing immersion time, and the wetting force remained a constant value after 5 s immersion time. In the initial soldering reaction, $(Cu,Ni)_6Sn_5$ intermetallic compound (IMC) and P-rich Ni layer formed at the SAC305/ENEPIG interface. After a prolonged reaction, the P-rich Ni layer was destroyed, and $(Cu,Ni)_3Sn$ IMC formed underneath the destroyed P-rich Ni layer. In the high-speed shear test, the percentage of brittle fracture increased with increasing shear speed.

Ingredient analysis of 태환이식 excavated from 황남대총 남분 and the characteristics (황남대총 남분출토 태환이식의 성분분석과 그 특징)

  • Ju, Jin-ok;Kang, Dai-il
    • 보존과학연구
    • /
    • s.27
    • /
    • pp.129-143
    • /
    • 2006
  • This report is on a scientific investigation of 3 pairs of 금제태환이식 which were excavated from 황남대총 납분. 태환 is a main part of 태환이식 and it could be classified with 4 types in how to produce, especially how many the golden petal was used. In this investigation, they,3 pairs of 금제태환이식 from 황남대총 남분, were in 3 of 4 types and also I could find that this result was not on the technical progress but on the ingredient of metal. Also, In the result of ingredient assay, I could find that although they were in one pair of 태환 one piece was made in gold and silver alloy and the other piece was made in 99.5 percent of pure Ag with gold amalgam plating. And the another pair was getting red from others because of making in 33percent of Ag and 77 percent of gold, high Ag content. And All pairs of 태환 have a small quantity of Copper. As above, although they are one pair they have the difference of how to produce and the difference of volume and ingredient content, it means that these pairs of 태환 from 황남대총 남분 were made in pressure of time. From now on, if we investigate the ingredient and how to produce of 태환이식 in the local comparative analysis, namely natural science method, we can find out the metal art technique and the social aspect of the ancient times as not analogical inference but scientific basis.

  • PDF

A Study on Shear Bond Strength of Heat Press Ceramic to Non Precious Porcelain Metal (도재용착용 비귀금속과 열가압성형도재의 전단결합강도 연구)

  • Kim, Seong-Soo;Kim, Wook-Tae;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.1
    • /
    • pp.37-45
    • /
    • 2011
  • Purpose: Heat pressed ceramics, used for all ceramic restorations, have the additional advantage of being technically less change through using of the lost-wax technique. Conceptually, combining the ceramic with the clinically proven reinforcing ability of a metal framework would be advantageous; however, cause of mismatching of fusion between ceramics and metal frameworks which from differences of casting temperature and coefficient of thermal expansion, pressed ceramics could not be used with a metal framework. The purpose of this study was to compare shear bond strength of press-to metal ceramic to porcelain fused non precious metal and feldspatic porcelain fused non precious metal. Methods: The 30 metal specimens were casted in a porcelain fused non precious metal nickel-chromium alloy. They were divided into 3 groups by surface treatment and applied ceramic: $125{\mu}m$ aluminium oxide sandblasting and veneered feldspatic porcelain (group FP), $125{\mu}m$ aluminium oxide sandblasting and had press-to-metal ceramic applied (group PC), porcelain bonder (gold bonder) fused on surface of metal specimens and had press-to-metal ceramic applied (group PCG). In each group 10 metal specimens were used. The press-to-metal ceramic applied 20 specimens had ash-free wax pattern applied, the metal-wax complexes invested, and were pressed with heat press ceramic. All specimens were subjected to shear bond strength test at a crosshead speed of 1.0 mm/min. Results: The results of measured in Mean SD and data were analyzed by one-way AVOVA (p= .05) and Tukey HSD test (p= .05).: group FP $16.090{\pm}1.841$ MPa, group PC $12.620{\pm}1.8256$ MPa, group PCG $10.920{\pm}0.9283$, significant differences between all groups (p < .05). Significant differences were found in each between group FP and group PC, group FP and group PCG (p < .05). Conclusion: The shear bond strength of press-to-metal ceramic to porcelain fused non precious metal was described higher in unused gold bonder group than used gold bonder groups.

Scientific Analysis of Baekje Earrings from Habjung-ri Site in Buyeo (부여 합정리 유적 출토 백제이식의 과학적 분석)

  • Cho, Hyunkyung;Jeon, Yuree;Eo, Jieun;Cho, Namchul
    • Conservation Science in Museum
    • /
    • v.13
    • /
    • pp.71-80
    • /
    • 2012
  • So-hwan earring(small hoop earing) is orbicular earring that have only main hoop. In this study, So-hwan earring from Baekje tombs are analyzed scientifically and those is attempted to find the correlation between scientific results and historical constituent. Six earrings were excavated from Habjung-ri sites in Buyeo and formative features and material characteristics of them were analyzed by microscope and XRF. As a results, various toreutics about producing gold silver alloy, pressure welding and amalgam plating that existed in Baekje from Ungjin period to Sabi period.

TEM Observation of Microstructure in Al-Sc alloys (투과전자현미경에 의한 Al-Sc합금의 미세구조 관찰)

  • 이영호;문정호;이갑호;이명현;서원선
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.44-44
    • /
    • 2003
  • Scandium을 소량 첨가한 Al합금은 용체화 처리 후 시효에 의해 강화되며, 합금의 주 강화상은 Ll2 type의 규칙구조를 갖는 A1$_3$Sc상으로 열처리시 아주 미세한 정합의 구형입자로 석출한다. Scandium은 Al합금에서 첨가원소의 at%에 따른 경량화 효과가 Gold 다음으로 크다. 현재까지의 Al-Sc계 합금에 대한 연구는 시효경화에 따른 기계적 특성 변화에 대해서만 이루어져 왔으나 본 연구에서는 투과전자현미경을 이용하여 열처리에 따른 미세조직의 변화, 급냉 상태에서 생성된 A13Sc입자의 형성 및 계면구조, 시효에 따른 석출거동을 규명하였다. 실험에 사용된 alloy는 미국의 Ashurst 사에서 제조된 Al-2wt%Sc모합금과 순도 99.9%의 Al을 혼합하여 Arc melting법으로 제조하였다. Primary A13Sc상은 Ll2 type으로 응고시에 용융상태에서 먼저 핵생성되어 Al의 핵생성 site로 작용한다. 635$^{\circ}C$에서 용체화 처리한 시편에서는 수백 nm 크기를 갖는 $Al_3$Sc상이 계면과 matrix내에 구형으로 존재함을 확인하였다. 수백 nm 크기의 $Al_3$Sc상의 내부에는 역위상 경계(Antiphase boundary)이 존재로 인한 특징적인 contrast가 관찰되었으며, 이 $Al_3$Sc상은 응고시 생성된 작은 $Al_3$Sc상들이 모여져 생성된 것으로 추측된다. 수백 nm 크기 의 $Al_3$Sc사와 Al matrix 사이의 계면에는 격자상수 차이에 의한 많은 edge dislocation들이 관찰된다.

  • PDF

Design and Fabrication of a Low-cost Wafer-level Packaging for RF Devices

  • Lim, Jae-Hwan;Ryu, Jee-Youl;Choi, Hyun-Jin;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.2
    • /
    • pp.91-95
    • /
    • 2014
  • This paper presents the structure and process technology of simple and low-cost wafer-level packaging (WLP) for thin film radio frequency (RF) devices. Low-cost practical micromachining processes were proposed as an alternative to high-cost processes, such as silicon deep reactive ion etching (DRIE) or electro-plating, in order to reduce the fabrication cost. Gold (Au)/Tin (Sn) alloy was utilized as the solder material for bonding and hermetic sealing. The small size fabricated WLP of $1.04{\times}1.04{\times}0.4mm^3$ had an average shear strength of 10.425 $kg/mm^2$, and the leakage rate of all chips was lower than $1.2{\times}10^{-5}$ atm.cc/sec. These results met Military Standards 883F (MIL-STD-883F). As the newly proposed WLP structure is simple, and its process technology is inexpensive, the fabricated WLP is a good candidate for thin film type RF devices.

Finite element analysis of stress distribution on supporting bone of posterior implant partial dentures by loading location (유한요소 분석을 이용한 하중 위치에 따른 구치부 임플란트 국소의치 지지골의 응력 분포 연구)

  • Son, Sung-Sik;Kim, Young-Jick;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.93-101
    • /
    • 2007
  • The purpose of this study is to evaluate the effect of three different oblique mechanical loading to occlusal surfaces of posterior implant partial dentures on the stress distributions in surrounding bone, using 3-dimensional finite element method. A 3-dimensional finite element model of a posterior implant partial dentures composed of three unit implants, simplified 3 gold alloy crown and supporting bone was developed according to the design of AVANA self tapping implant for this study. Three kinds of surface distributed oblique loads(300 N) are applied to following occlusal surfaces in the three crowns; 1) All occlusal surfaces in the three crown(load of 300 N was shared to three crown), 2) Occlusal surface of centered crown (load of 300 N was applied to a centered crown), 3) Occlusal surface of proximal crown(load of 300 N was applied to a distal proximal crown). In the results, 141 MPa of maximum von Mises stress was calculated at third loading condition and 98 MPa of minimum von Mises stress was calculated at first loading condition. From the results, location and type of occlusive loading conditions are important for the safety of supporting bone.

  • PDF