• Title/Summary/Keyword: glove

Search Result 321, Processing Time 0.026 seconds

Epidemiologic Analysis of Burns in Military Hospital

  • Choi, Jangkyu;Park, Sejin;Kim, Hyun Chul
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.145-157
    • /
    • 2017
  • Purpose: We accessed epidemioloy of 908 acute burns (7 years) in the military, of injuries and propose proper educational programs to suit community. Methods: We surveyed burn demographics, circumstances of injuries, size, result of treatment. Results: The mean age was 20.6 years. The flame burns (FB) (325, 35.8%) were most common, followed scald (SB) (305, 33.6%), contact (CB) (219, 24.1%), electric (EB) (45, 5.0%) and chemical burns (ChB) (14, 1.5%). The more occurred during winter (29.7%). SB had mean 3.9% total body surface area (TBSA). The 251 (82.3%) had superficial burns by spillage of hot water/food on lower limbs (45.6%), feet (33.8%) in summer (34.8%), treated with simple dressing (92.8%). Morbidity rate was 5.6%; post traumatic stress disease (PTSD) (0.7%). FB had large wound (9.3% TBSA). The 209 (64.3%) had superficial burns by ignition to flammable oils (31.7%) and bomb powders (29.2%) on head/neck (60.3%), hands (58.6%) in summer (31.7%), autumn (30.2%). They underwent simple dressing (83.4%) and skin graft (16.0%). Morbidity rate was 18.8%; PTSD (10.5%), inhalation injuries (4.0%), corneal injury (3.7%), amputations (0.9%), and mortality rate (1.2%). CB had small (1.1% TBSA), deep burns (78.5%) by hotpack (80.4%) on lower limbs (80.4%). The more (59.8%) underwent skin graft. EB had 6.8% TBSA. The 29 (64.4%) had superficial burns by touching to high tension cable (71.1%) on hand (71.1%), upper limbs (24.4%) in autumn (46.8%). They underwent simple dressing (71.1%) and skin graft (24.4%). They showed high morbidity rate (40.0%); loss of consciousness (13.3%), nerve injuries (11.1%), neuropathy (8.9%), amputations (2.2%), and mortality rate (2.2%). Conclusions: The cook should wear apron over the boots during work. The lighter or smoking should be strictly prohibited during work with flammable liquids or bomb powders. Don't directly apply hotpack to skin for a long time. Use insulating glove during electric work. Keep to the basic can prevent severe injury and proper education is important.

Implementation of Real-time Recognition System for Continuous Korean Sign Language(KSL) mixed with Korean Manual Alphabet(KMA) (지문자를 포함한 연속된 한글 수화의 실시간 인식 시스템 구현)

  • Lee, Chan-Su;Kim, Jong-Sung;Park, Gyu-Tae;Jang, Won;Bien, Zeung-Nam
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.6
    • /
    • pp.76-87
    • /
    • 1998
  • This paper deals with a system which recognizes dynmic hand gestures, Korean Sign Language(KSL), mixed with static hand gesture, Korean Manual Alphabet(KMA), continuously. Recognition of continuous hand gestures is very difficult for lack of explicit tokens indicating beginning and ending of signs and for complexity of each gesture. In this paper, state automata is used for segmenting sequential signs into individual ones, and basic elements of KSL and KMA, which consist of 14 hand directions, 23 hand postures and 14 hand orientations are used for recognition of complex gestures under consideration of expandability. Using a pair of CyberGlove and Polhemus sensor, this system recognizes 131 Korean signs and 31 KMA's in real-time with recognition rate 94.3% for KSL excluding no recognition case and 96.7% for KMA.

  • PDF

A Comparison of Microbial Load on Bare and Gloved Hands among Food Handlers (맨손과 장갑 낀 손의 미생물 오염도 비교)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.4
    • /
    • pp.298-305
    • /
    • 2011
  • Objectives: There has been a great amount of controversy in the food industry over the effectiveness of using gloves. The objectives of this study were to examine the microbial contamination of food handlers' hands and determine if using gloves could ensure safe handling of foods. Methods: Samples were collected through the glove-juice method from the bare and gloved hands of food handlers at work and were analyzed for the presence of aerobic plate counts, total coliform, fecal coliform, Escherichiacoli, Staphylococcus aureus, and Salmonella spp. Microbiological testing was conducted according to the Food Code of Korea. Results: Microbial contamination was consistently higher with bare hands than with gloved hands, although the microbial loads on both hands increased over time. Under certain conditions, there were significant differences between the bacterial loads on bare and on gloved hands (p<0.05). E. coli, S. aureus, and Salmonella spp. were still alive on both bare and gloved hands at the time the food handlers finished their work. Conclusions: Wearing gloves was associated with a marked reduction of bacterial contamination of the hands. However, the practice of continuously wearing gloves during food handling increases the potential for cross-contamination of bacteria. The findings of this study emphasize the need for a rational use of gloves, and strict adherence to hand hygiene compliance among food handlers.

Incidence and Risk Factors of Infection Caused by Vancomycin-Resistant Enterococcus Colonization in Neurosurgical Intensive Care Unit Patients

  • Se, Young-Bem;Chun, Hyoung-Joon;Yi, Hyeong-Joong;Kim, Dong-Won;Ko, Yong;Oh, Suck-Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.2
    • /
    • pp.123-129
    • /
    • 2009
  • Objective: This study was aimed to identify the incidence and risk factors of vancomycin-resistant enterococcus (VRE) colonization in neurosurgical practice of field, with particular attention to intensive care unit (ICU). Methods: This retrospective study was carried out on the Neurosurgical ICU (NICU), during the period from January. 2005 to December. 2007, in 414 consecutive patients who had been admitted to the NICU. Demographics and known risk factors were retrieved and assessed by statistical methods. Results: A total of 52 patients had VRE colonization among 414 patients enrolled, with an overall prevalence rate of 6.1%. E. faecium was the most frequently isolated pathogen, and 92.3% of all VRE were isolated from urine specimen. Active infection was noticed only in 2 patients with bacteremia and meningitis. Relative antibiotic agents were third-generation cephalosporin in 40%, and vancomycin in 23%, and multiple antibiotic usages were also identified in 13% of all cases. Multivariate analyses showed Glasgow coma scale (GCS) score less than 8, placement of Foley catheter longer than 2 weeks, ICU stay over 2 weeks and presence of nearby VRE-positive patients had a significantly independent association with VRE infection. Conclusion: When managing the high-risk patients being prone to be infected VRE in the NICU, extreme caution should be paid upon. Because prevention and outbreak control is of ultimate importance, clinicians should be alert the possibility of impending colonization and infection by all means available. The most crucial interventions are careful hand washing, strict glove handling, meticulous and active screening, and complete segregation.

Study on the perception of health science college students about the personal protection of dental personnels (치과 의료종사자의 개인보호장구 착용에 대한 보건계열 대학생의 인식)

  • Kang, Eun-Ju;Choi, Mi-Hye
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.5
    • /
    • pp.637-647
    • /
    • 2011
  • Objectives : This study was performed to enhance infection control and to establish the fundamental and practical improvement by the survey on personal protection of dental personnels with health science college students. Methods : We performed the survey with 585 individual students affiliated with health science in Jeonbuk province and statistically analyzed by SPSS 12.0 program. Results : The frequencies of the clinic gown as a personal protection were 96.0% of dentists (p<0.01) and 88.0% of dental hygienists (p<0.05) respectively in college-associated dental hospital when we compared with institution scale. The frequencies of the medical gloves as a compulsory personal protection were 47.2% of dentists and 34.6% of dental hygienists respectively (p<0.001). The frequencies of the medical mask as a compulsory personal protection were 84.0% of dentists (p<0.001) and 52.2% of dental hygienists (p<0.05) respectively shown by freshman students. The frequencies of the safety glasses as a compulsory personal protection were 12.3% of dentists and 2.5% of dental hygienists shown by freshman students (p<0.001). Conclusions : The results reflect that current dental personnel's concern of personal protection need to be increased continuously in accordance with current demands and eventually suggest their effort to put their action on personal protection in their dental office.

A Study on Synthetic Method and Material Analysis of Calcium Ammine Chloride as Ammonia Transport Materials for Solid SCR (Solid SCR용 암모니아 저장물질인 Calcium Ammine Chloride의 합성방법 및 물질분석 연구)

  • Shin, Jong Kook;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.199-207
    • /
    • 2015
  • Solid materials of ammonia sources with SCR have been considered for the application of lean NOx reduction in automobile industry, to overcome complex problems of liquid urea based SCR. These solid materials produce ammonia gas directly with proper heating and can be packaged by compact size, because of high volumetric ammonia density. Among ammonium salts and metal ammine chlorides, calcium ammine chloride was focused on this paper due to low decomposition temperature. In order to make calcium ammine chloride in lab-scale, simple reactor and glove box was designed and built with ammonium gas tank, regulator, and sensors. Basic test conditions of charging ammonia gas to anhydrous calcium chloride are chosen from equilibrium vapor pressure by Van't Hoff plot based on thermodynamic properties of materials. Synthetic method of calcium ammine chloride were studied for different durations, temperatures, and pressures with proper ammonia gas charged, as a respect of ammonia gas adsorption rate(%) from simple weight calculations which were confirmed by IC. Also, lab-made calcium ammine chloride were analyzed by TGA and DSC to clarify decomposition step in the equations of chemical reaction. To understand material characteristics for lab-made calcium ammine chloride, DA, XRD and FT-IR analysis were performed with published data of literature. From analytical results, water content in lab-made calcium ammine chloride can be discovered and new test procedures of water removal were proposed.

Design of Tritium Handling System(II): Injection System, Regeneration System (삼중수소취급계통의 설계(II): 주입계통, 재생계통)

  • 김광신;김경숙;정은수;손순환;김위수
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.117-123
    • /
    • 2003
  • In succession to the previous paper, the tritium injection system and the regeneration system of the tritium handling system are presented. Both systems should be placed inside glove boxes since there can be potential leakage of tritium from these systems. The tritium injection system should be capable of measuring the exact amount of the injected tritium to keep track of the tritium inventory. The tritium injection system is designed to recover the remaining tritium from the system after injection for the minimization of tritum release to the environment as well as for the recovery of precious resource. TRS equipment such as MS, Ni catalyst bed, and metal getter are regenerated with a standalone regeneration system. Unlike other equipments which can be regenerated by heating and purging with appropriate gas, regeneration of the metal getter used to recover tritium is somewhat complicated.

  • PDF

The Database Development of 2-D and 3-D Hands Measurement for Improving Fitness of Gloves - Focused on the Classification of Hand Type and Analysis of 3-D Hand Shape - (장갑의 적합성 향상을 위한 손부의 2차원 및 3차원 계측정보 DB구축에 관한 연구 -손의 유형분석 및 3차원 입체형상 분석을 중심으로-)

  • 최혜선;김은경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.910
    • /
    • pp.1300-1311
    • /
    • 2004
  • The aim of this study was to provide the 2 and 3 dimensional statistics requisite in the sizing system and design of gloves. The 64 2-dimensional static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. To summarize the information from the measurement values, a Factor Analysis and a Cluster Analysis among multivariate analyses were performed. 3-D scanner was used for visual results of hand shape of each cluster. The results were as follows. Twenty-two items were used for the factor and cluster analysis in order to classify the adult hand shape. The variable quantities that are explained by a total of 3 factors amounted to under 79.37% of the variable quantities. The definition results of the factors related to the hands are as follows: Factor 1 is the horizontal dimension, the thickness of hand factor; Factor 2 is the height of the crotch; and Factor 3 is the vertical dimension of the hand. The adults' group hand was divided into 2 clusters according to a cluster analysis using factor scores. The characteristics according to hand type were as follows: Cluster 1 referred to high horizontal dimensions and thickness, rather small vertical dimensions and crotch height; and Cluster 2 represented the rather smaller horizontal dimensions and thickness but longer hand length than Type 1. To provide specific shape data of each cluster, 3-D scanner measurement was performed. 3-dimensional data base was developed for each cluster type and visual information was provided.

Separation of $PuO_2^{2+}$, $Pu^{4+}$ and $Pu^{3+}$ by Ion Chromatography (이온크로마토그래피에 의한 $PuO_2^{2+}$, $Pu^{4+}$$Pu^{3+}$의 분리)

  • Joe, Kih Soo;Kim, Jong Gu;Park, Yang Soon;Kim, Do Yang;Eom, Tae Yoon
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.280-285
    • /
    • 1999
  • Separation of plutonium species was studied by ion chromatography installed in a glove box for the determination of plutonium element. The plutonium species, $PuO_2^{2+},\; PC^{4+}\; and\; Pu^{3+}$, were stably separated on dynamically equilibrated cation exchanger using 1-octanesulfonate and ${\alpha}$-HiBA eluant after controlling the plutonium oxidation states with KI, $NaNO_2\;or=;KBrO_3$ based on the oxidation-reduction potentials. For the separation of plutonium from other matrix, $PuO_2^{2+}\; and\; Pu^{4+}$ were reduced to $Pu^{3+}$ with KI and $NaNO_2$ followed by cation exchange chromatography.

  • PDF

Systematic Review on the Type and Method of Convergence Study of Inertial Measurement Unit (관성 측정 장치의 융합연구 형태와 방법에 관한 체계적 고찰)

  • Lee, Hey-Sig;Park, Hae-Yean
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.3
    • /
    • pp.119-126
    • /
    • 2020
  • The purpose of this study is to identify trends in the type and method of Inertial Measurement Unit (IMU) by investigating studies on the type and method of convergence study of the IMU by systematic review. The study was conducted using PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. 23 studies that meet the selection criteria were selected from 630 studies identified by three databases. As a result of this study, showed that various research using IMU was being conducted around the world, and the type of IMU was strap, full body suit, belt, wrist watch, shoes and glove. Among them, the number of strap-type IMUs was the largest at 11. The IMU's strengths were simplicity, real-time data collection and ease of application, which were used as measurement methods such as task, walking, and range of joint. The result of this study is expected to be used as basic data for experts in the medical and rehabilitation fields that conduct IMU research.