• Title/Summary/Keyword: glass window

Search Result 223, Processing Time 0.025 seconds

The Development and Application of Sound Quality Index for the Improving Sound Quality to Road Vehicle Power Window System (차량 윈도우 리프트 음질 향상을 위한 음질 지수 제작 및 개선에의 응용)

  • Kim, Seong-Hyeon;Park, Dong-Chul;Jo, Hyeon-Ho;Seong, Won-Chan;Kang, Yeon-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.525-530
    • /
    • 2013
  • With the increasing the importance of emotional quality of vehicle, the sound quality of systems with electric motor components has become increasingly important. Electric motors are used for windows, seats, sun roof, mirrors, steering columns, windshield wiper, climate control blowers, etc. In this paper, a study was conducted to identify sound quality factors that contribute to customer's satisfaction and preference of the window lift system. Jury test for subjective evaluation was carried out and sound quality index was developed. Averaged sound pressure level and sharpness were significant factors when glass moves down. Also, maximum loudness at stop section and averaged loudness were significant factor when glass moves up. Noise source identification was carried out for the reduced the loudness and sharpness during glass transferred section and impulsive noise at stop section, Using the source identification result, several improvement points were applied. And finally, the degree of sound quality improvement was judged using sound quality index.

  • PDF

A Study on the Heat Transfer Phenomenon through the Glazing System (창호를 통한 열전달 현상에 관한 연구)

  • Kang, Eun-Yul;Oh, Myung-Won;Kim, Byung-Sean
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

Nonvolatile memory devices with oxide-nitride-oxynitride stack structure for system on panel of mobile flat panel display

  • Jung, Sung-Wook;Choi, Byeong-Deog;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.911-913
    • /
    • 2008
  • In this work, nonvolatile memory (NVM) devices for system on panel of flat panel display (FPD) were fabricated using low temperature polycrystalline silicon (LTPS) thin film transistor (TFT) technology with an oxide-nitride-oxynitride (ONOn) stack structure on glass. The results demonstrate that the NVM devices fabricated using the ONOn stack structure on glass have suitable switching characteristics for data storage with a low operating voltage, a threshold voltage window of more than 1.8 V between the programming and erasing (P/E) states after 10 years and its initial threshold voltage window (${\Delta}V_{TH}$) after $10^5$ P/E cycles.

  • PDF

A Study on Analysis for Energy Demand of the Heating, Cooling and Lighting in Office Building with Transparent Thin-film a-Si BIPV Window (투광형 박막 BIPV 창호 적용에 따른 냉난방 및 조명 부하 저감에 관한 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Park, Jang-Woo;Kim, Bit-Na
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.91-96
    • /
    • 2013
  • The purpose of this study was to analyze the annual energy demand including heating, cooling and lighting according to kind of windows with transparent thin-film a-Si Building Integrated Photovoltaic(a-Si BIPV) for office building. The analysis results of the annual energy demand indicated that the a-si BIPV window was reduced by 8.4% than the clear gazing window. The base model A was combinate with a-Si BIPV window area of 67% and clear window area of 33% among the total exterior area. The model B is to be applied with low-e clear glass instead of clear glass of the base model A. The model B was reduced to annual energy demand of 1% more than the model A. Therefore, By using a-si BIPV solar module, the cooling energy demand can be reduced by 53%(3.4MWh) and the heating energy demand can be increase by 58%(2.4MWh) than clear glazing window in office building. Also, Model C applied to the high efficient lighting device to the model B was reduced to annual energy demand of 14.4% more than the Model D applied to the high efficient lighting device to the model A. The Model E applied with daylight dimming control system to the Model C was reduced to annual energy demand of 5.9% more than Model C.

A Study on Integration of Pre-manufactured Window Systems with Conventional Building Design Elements (자연채광 요소기술 도출을 위한 창호시스템과 건물요소와의 통합화에 관한 연구)

  • Kim, Jeong-Tai;Jeong, In-Young;Jeong, Yu-Gun
    • KIEAE Journal
    • /
    • v.2 no.2
    • /
    • pp.15-22
    • /
    • 2002
  • Importation of mass production of building elements with standardization are vital way for environment-friendly architectural planning, which it makes the lifespan of a building longer than normal with easier maintenance and remodeling. The advantage might be magnified here in Korea since typical types of apartment house are dominated in our construction market. For the purpose, a series of pre-manufactured window systems is one of the optimal elements to be prototype building modules. In the design process of the system windows, lots of consideration should be involved and they include aesthetics, thermal performance, noise reduction, airtightness, and so forth. A real survey on the ready-made window systems has been performed and its optical issue related to luminous peculiarity is what is of major interest in this study. In addition, technical review on more advanced window products and their adaptable potential for the integration with fundamental architectural design elements were carried out.

An Experimental Study on the Verification of Fire Extinguishing Performance According to the Combustion Characteristics of Building Window Frame (건축물 창호 프레임의 연소특성에 따른 방화성능 검증에 관한 실험적 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.54-55
    • /
    • 2021
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

Study on Design Considerations to Prevent Bird Collisions with Glass (조류 유리충돌 방지를 위한 디자인 개선방안에 관한 고찰)

  • Lee, Hyung-Sook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.15 no.1
    • /
    • pp.13-20
    • /
    • 2013
  • Bird collisions with glass are a substantial source of human-caused avian mortality. It has been estimated that between 100 million and 1 billion birds die in collisions with windows every year, and bird-window collisions can have a particularly serious impact on populations because glass is dangerous for strong, healthy, breeding adults. The purpose of this study are to address the bird-window collision issue and to provide suggestions for bird-safe development by reviewing precedent studies on bird collision and analyzing bird-friendly design guidelines. Typically reflections of the sky, clouds or trees on glass, green plants in lobbies, and lights attract and confuse both migrating and resident birds. Therefore birds fatally fly into the glass because they do not recognize that reflections are false and that glass is a barrier. Many cities such as Toronto, Chicago and New York have made efforts on reducing the bird collision by encouraging the creation of environmentally conscious and bird-safe buildings. The USGBC also introduced a bird-safety credit as part of its environmental certification process, called LEED. The results of the study presented that architects and builders can help reduce or prevent bird from collisions in both new construction and existing structures with creative use of design elements. The measures to reduce bird collisions include using glass with an embedded pattern, opaque or translucent films, decals, dot patterns, awnings, louvers, and grilles. Turning off lights after midnight during the spring and fall migrations can be part of the solution as well. In order to reduce bird mortality, the most important thing is to generate awareness of the issue among designers, builders, as well as the public. Also local governments need to develop bird-friendly design guidelines and planning mechanisms to encourage bird-safe development and building operation.

Effects of Glass Frit Size on the Sintering Behavior of Cu Termination Paste in MLCC (Glass Frit의 입도가 MLCC 외부전극 Paste의 소결거동에 미치는 영향)

  • Lee, Kyu-Ha;Jeon, Byung-Jun;Kim, Chang-Hoon;Kwon, Young-Geun;Park, Myung-Jun;Gu, Hyun-Hee;Uhm, Ji-Won;Kim, Young-Tae;Hur, Kang-Heon
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.2
    • /
    • pp.175-180
    • /
    • 2009
  • Multilayer ceramic capacitors (MLCCs) have continually been made smaller in size and larger in capacity in resent years. However, the end termination electrode is still thick in many MLCCs. In this study, we used small grain glass frit to embody thin film and highly densification in the end termination by improve sintering driving force with well-dispersion and rising surface energy. Pastes were fabricated using size changed glass frit, such as 0.1 ${\mu}m$, 0.5 ${\mu}m$, 1.0 ${\mu}m$, 4.0 ${\mu}m$. Fabricated pastes were applied 05A475KQ5 chip and fired various sintering temperatures to analyze sintering behavior of pastes. Consequently, small glass frit used pastes have many merits than larger, such as well-dispersion, improve cornercoverage and surface roughness, possibility of low temperature sintering. However, we confirmed that small glass frit used pastes have narrow sintering window by rapid completion of sintering densification.

The study of temperature changes heat on the window glass using the rolling stock (철도 차량 유리창에 발열 유리 시스템 사용시 객실 온도 변화에 대한 연구)

  • Ahn, Jong-Kon;Yoo, Suk-Hee;Kang, Beom-Su;Kwon, Jin;Im, Won-Suk;Kang, Ju-Hee
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1109-1116
    • /
    • 2009
  • To the development of construction techniques and construction of glass-walled structure is generalized. Existing wall to support the role of the vertical load was lose. Features and the beautiful side of the curtain wall job was to be highlighted. Carriage access to the interior of the windows will cause pain in the neck with a cold feeling. And in the windows, drafty windows, under floor heating occurs despite the condensation phenomenon occurs. droplets that occurs around the window (the cause of the mold) in summer and winter, the heat energy and move through the glass is warmer outside. Therefore, to reduce energy efficiency affects absolutely. When you apply heat to the carriage window, the surface of the glass system, the spread of the cold air does not occur. Therefore, energy savings cars and heating of the interior is cold.

  • PDF

Infrared Transmitting Glass Ceramics for Passive and Active Applications

  • Zhang, Xianghua;Adam, J.L.
    • Ceramist
    • /
    • v.10 no.3
    • /
    • pp.48-54
    • /
    • 2007
  • Glass-ceramics transparent above $10\;{\mu}m$ in the infrared, have been synthesized. They are based on germanium and antimony sulphides or selenides associated to alkali halides. They are prepared by heating glass samples at temperatures above the glass transition, as a function of time. Ceramisation can be controlled, so that sub-100 nm crystals are generated in the glass matrix. Then, low light scattering is achieved and the transparency window of the original glass is maintained. When gallium sulphide is added, glass ceramics can be doped with rare-earth ions. Emissions from the $^4F_{3/2}$ and $^4I_{13/2}$ of $Nd^{3+}$ and $Er^{3+}$ ions, respectively, are more intense in glass-ceramics, as compared to their vitreous counterpart. Examination of band profiles and decaytimes show that rare-earth ions are embedded in both crystalline and glassy environments.

  • PDF