• Title/Summary/Keyword: glass furnace

Search Result 199, Processing Time 0.025 seconds

Electric Furnace Sysetem development of Batch Type Back Light Glass Unit (Batch Type Back Light Glass Unit 소성 봉착 시스템 개발)

  • Kim, Soo-Yong;Lee, Oh-Keol;Kim, Sang-Hyo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1798-1800
    • /
    • 2001
  • As a batch Type device, this machine is contrive to seal glass plates for plasma BLU (Back Light Unit) by indirect heating from electric heaters. In order to maintain the heating / cooling Chambers clean, this machine uses a muffle formation. The components of the machine are listed bellow.

  • PDF

An Experimental Study on Alkali-Silica Reaction of Mortar Containing Waste Glass and By-products (폐유리 및 산업부산물을 혼입한 모르터의 ASR에 관한 실험적 연구)

  • Lee, Bong-Chun;Kwon, Hyuk-Joon;Kim, Jeong-Hwan;Lee, Jun;Park, Seung-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.93-98
    • /
    • 2001
  • Using waste glass in concrete can cause crack and strength loss by the expansion of alkali-silica reaction(ASR). In this study, ASR expansion and properties of strength were analyzed in terms of clear waste glass grading, and by-products(fly ash, blast-furnace slag) and by-products content for reduction ASR expansion due to waste glass. In this accelerated ASTM C 1260 test of waste glass, pessimum grading can be found. Also, when the by-products are used with waste glass, there is an effect on reduction of expansion and strength loss due to ASR between the alkali in the cement paste and the silica in the waste glass.

  • PDF

A Fault Diagnosis System of Glass Melting Furnace Using A Fuzzy Expert System (퍼지 전문가 시스템을 이용한 유리 용해로 이상 감시 시스템 구축 사례)

    • Journal of Intelligence and Information Systems
    • /
    • v.8 no.1
    • /
    • pp.65-65
    • /
    • 2002
  • 본 논문에서는 용해로 이상감시를 위한 실시간 유리 용해로 운전 전문가시스템을 구축한 결과를 소개한다. 유리 용해 공정에서는 운전자의 경험지식에 의해 내부의 상황을 판단하게 되고, 이는 용해로 수명과 제품의 품질에 중요한 영향을 준다. 이를 전문가 시스템으로 구현하기 위하여, 먼저 기존 운전자의 지식을 취합, 분석한다. 그 후,취합된 각 지식들의 특성에 부합하도록 이진 규칙(Crisp Rule)과 퍼지 규칙(Fuzzy Rule)으로 구분한다. 이 때, 선형 회귀분석을 통하여 퍼지 규칙의 입력을 결정함으로써 보다 정확한 운전 지식의 표현이 가능하도록 하였다. 설계된 알고리듬은 젠심(Gensym)사의 실시간 전문가 시스템 개발 툴인 G2를 사용하여 구현하였다. 제시된 퍼지 전문가 시스템은 삼성코닝(주) 수원사업장의 실제 생산 용해 공정에 직접 적용하여 그 효율성이 검증되었다.

Fuzzy Learning Algorithms for Time Series Prediction (시계열 예측을 위한 퍼지 학습 알고리즘)

  • 김인택;공창욱
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.7 no.3
    • /
    • pp.34-42
    • /
    • 1997
  • This paper presents new fuzzy learning algorithms and their applications to time series prediction. During generating fuzzy rules from numerical data, there is a tendency to produce conflicting rules which have same premise but different consequence. To resolve the problem, we propose MCM(Modified Center Method) which is proven to reduce the error in the prediction. We have applied MCM to the analysis of Mackey-Glass time series and Gas Furnace da.ta to verify its efficiency.

  • PDF

Optimization of Spin-On-Glass Planarization Process Using Statistical Design of Experiments (통계적 실험계획법을 이용한 SOG 평탄화 공정의 최적화)

  • 임채영;박세근
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.198-205
    • /
    • 1992
  • Abstract-Planarieation technology, which is essential to VLSI, has been developed using non-etch back Spin- On-Glass (SOG). Process factors for 1.5 micron double metal technology are optimized by the statistical design of experiments. Optimum conditions are found to be a process with twice SOG coating, sufficiently long hot plate baking at 300t, and furnace curing for 40 minutes below 400$^{\circ}$C.

  • PDF

Effects of supplementary cementitious materials on drying shrinkage of cement mortar - a comparative study (혼화재에 따른 모르타르 건조수축-비교 연구)

  • Choi, Hoon Jae;Cui, Chengkui;Park, Chung-Hoon;Kim, Baek-Joong;Yi, Chongku;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.158-159
    • /
    • 2013
  • In this study, effects of supplementary cementitious materials(fly ash, blast furnace slag and waste glass) on drying shrinkage of cement mortar were compared and evaluated. The results showed drying shrinkage of cement mortar using blast furnace slag and waste glass is larger than shrinkage due to capillary pressure, while using fly ash is smaller.

  • PDF

Role of Added Metal Oxide in the Adherence Mechanism of Low Melting Glass to Several Metal Seals (저융점유리와 각종금속과의 봉착기구에 있어서 금속산화물의 역할)

  • 정창주
    • Journal of the Korean Ceramic Society
    • /
    • v.11 no.1
    • /
    • pp.3-9
    • /
    • 1974
  • The role of added metal oxide in the adherence mechanism of low melting glass to several metal plates such as oxygen free high conducting copper, low carbon steel, chrominum galvanized on copper, and stainless steel was investigated. The metal oxide which added to glass were cupric oxide, ferric oxide, chromic oxide, and stainless steel oxide. The glass to that various metla oxide were added, sealed with several metal plates in the electric furnace at $650^{\circ}C$ for 5 minutes. The results as follows; 1) The interfacial reaction was promoted and strong chemical bonding with glass and metals by which the surface energy was decreased showed excellent sealing by addition of metal oxide. 2) When the interfacial reaction of glass and metals was promoted by addition of metal oxide found out that various adhernece mechanism were related to the sealing. 3) When the amount of metal oxide addition was 3-5% the excellent sealing was achieved.

  • PDF

RTA Post-annealing Effect on Poly-Si Thin Film Transistors Fabricated by Metal Induced Lateral Crystallization (금속 유도 측면 결정화를 이용한 박막 트랜지스터의 RTA 후속열처리 효과)

  • 최진영;윤여건;주승기
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.274-277
    • /
    • 2000
  • Thin Film Transistor(TFTs) were fabricated from poly-Si crystallized by a two-step annealing process on glass substrates. The combination of low-temperature(500$^{\circ}C$) Metal-Induced Lateral Crystallization(MILC) furnace annealing and high -temperature (700$^{\circ}C$) rapid thermal annealing leads to the improvement of the material quality The TFTs measured with this two-step annealing material exhibit better characteristics than those obtained by using conventional MILC furnace annealing.

  • PDF

Hydration Mechanism of Alkali Activated Slag Cement

  • Jong Cheol Kim;Keun Ho Auh;Sung Yun Hong
    • The Korean Journal of Ceramics
    • /
    • v.5 no.1
    • /
    • pp.35-39
    • /
    • 1999
  • For many years, alkali activated blast furnace slag cement containing no ordinary portland cement has received much attention in the view of energy saving and its many excellent properties. We examined the structural change of slag glass which was activated by alkali metal compounds using IR spectroscopy. The properties of hydrated products and unhydrated slag grains was characterized by XRD and micro-conduction calorimeter. Ion concentration change in the liquid during the hydration of blast furnace slag was also studied to investigated the hydration mechanism.

  • PDF

Development of Fabrication Method for Translucent Concrete and the Material Characteristics Associated with the Use of Mineral Admixture (반투명 콘크리트의 제조기법 개발과 무기혼화재 혼입에 따른 역학적 특성)

  • Kim, Sang-Chel
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.69-78
    • /
    • 2011
  • As recent concrete products changed to pursue high class, high quality, and high strength, as translucent concrete was developed to meet esthetic effects and exhibition purpose of structures. This study aims at introducing fabrication methods of various shapes of translucent concrete and evaluating feasibility of using mineral admixture such as fly ash, ground granulated blast furnace slag and granulated glass throughout experimental tests. As the result, it was found that compressive strength of translucent concrete block at 28 days is 32.2MPa and higher elastic modulus and Poisson's ratio than ordinary concrete block, which means that translucent concrete is widely applicable to structural purpose. Application of fly ash as a replacement of cement showed lower strength of 85 to 96% than Portland cement. In the meanwhile, ground granulated blast furnace slag showed 82 to 96% depending on the amount of replacement. The use of granulated glass as replacement of optical fiber was not applicable due to invisibility of light in concrete.

  • PDF