• 제목/요약/키워드: glass fiber reinforced glulam

검색결과 14건 처리시간 0.031초

Shear Performance of Glass Fiber Reinforced Glulam Bolted Connection

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.661-671
    • /
    • 2015
  • To evaluate the shear performance of the textile glass fiber and the sheet glass fiber reinforced glulam bolted connections, a tension type shear test was conducted. The average yield shear strength of the bolted connection of reinforced glulam was increased by 12% ~ 31% compared to the non-reinforced glulam. It was confirmed that the shear performance of 5D end distance of the glass fiber reinforced glulam connection corresponds to that of 7D of the non-reinforced glulam connection proposed in building design requirements in various countries. Compared to the non-reinforced glulam, the average shear strength of textile glass fiber reinforced glulam was markedly increased. The non-reinforced glulam and the GFRP reinforced glulam underwent a momentary splitting fracture. However, the failure mode of textile glass fiber reinforced glulam showed a good ductility.

Bonding Performance of Glulam Reinforced with Textile Type of Glass- and Aramid-Fiber, GFRP and CFRP

  • Kim, Keon-Ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권2호
    • /
    • pp.156-162
    • /
    • 2011
  • To evaluate the bonding performance of reinforced glulam, the textile type of glass fiber and aramid fiber, and the sheet type of glass fiber reinforced plastic (GFRP) and carbon fiber reinforced plastic (CFRP) were used as reinforcements. The reinforced glulam was manufactured by inserting reinforcement between the outmost and middle lamination of 5ply glulam. The types of adhesives used in this study were polyvinyl acetate resins (MPU500H, and MPU600H), polyurethane resin and resorcinol resin. The block shear strengths of the textile type in glass fiber reinforced glulam using MPU500H and resorcinol resin were higher than 7.1 N/$mm^2$, and these glulams passed the wood failure requirement of Korean standards (KS). In case of the sheet types, GFRP reinforced glulams using MPU500H, polyurethane resin and resorcinol resin, and CFRP reinforced glulams using MPU500H and polyurethane resin passed the requirement of KS. The textile type of glass fiber reinforced glulam using resorcinol resin after water and boiling water soaking passed the delamination requirement of KS. The only GFRP reinforced glulam using MPU500H after water soaking passed the delamination requirement of KS. We conclude that the bonding properties of adhesive according to reinforcements are one of the prime factors to determine the bonding performance of the reinforced glulam.

Bearing Strength of Glass Fiber Reinforced Glulam Bolted Connection

  • Kim, Keon-ho;Hong, Soon-il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.652-660
    • /
    • 2015
  • To study the bearing characteristics of glass fiber reinforced glulam for structural design, bearing strength tests were performed. Bearing loads were applied in the direction parallel to the grains, and the holes were prepared in such a way that the bolts would bear and support all the layers. The yield bearing strengths of the glass fiber reinforced glulam were found to be similar to those of the non-reinforced glulam, and were almost constant regardless of increases in bolt diameter. The ratio of the experimental yield bearing strength to the estimated bearing strength according to the suggested equation of the Korea Building Code and National Design Specification was 0.91~1.03. For the non-reinforced glulam and the sheet glass fiber reinforced plastic glulam, the maximum bearing load was measured according to the splitting fracture of specimens under bolt. The textile glass fiber reinforced glulam underwent only an embedding failure caused by the bearing load. The failure mode of reinforced glulam according to bearing load will influence the failure behavior of bolted connection, and estimating the shear yield strength of the bolted connection of the reinforced glulam is necessary, not only by using the bearing strength characteristics but also using the fracture toughness of the reinforced glulam.

유리섬유 조합에 따른 보강 집성재 볼트접합부의 전단강도 특성 (Shear Strength of Reinforced Glulam-bolt Connection by Glass Fiber Combination)

  • 김건호;송요진;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권1호
    • /
    • pp.51-57
    • /
    • 2013
  • 직물형 유리섬유 조합에 따른 보강 집성재의 볼트 접합부 전단 성능을 알아보기 위하여 인장형 전단시험을 실시하였다. 보강재는 직물형 유리섬유로서 유리섬유 배열 형태는 평직형과 능직형을 사용하였다. 보강 집성재는 5층으로 직물형 유리섬유의 삽입 위치와 조합 형태를 달리하여 층재 사이에 삽입 적층시켜 제작하였다. 인장형 전단 시험편은 강판 삽입형로서 끝면거리 7D에 직경 12, 16 mm의 볼트로 접합하였다. 체적비 1% 직물형 유리섬유 보강 집성재의 경우 12 mm 볼트 접합부의 항복 전단내력은 집성재 외층부보다 내층부를 보강한 시험편에서 10% 큰 값을 나타내었다. 체적비 2% 직물형 유리섬유 보강 집성재의 항복 전단내력은 12 mm 볼트 접합부의 경우 각층재 사이에 삽입 적층시킨 시험편이 보강하지 않은 접합부보다 약 22% 향상되었으며, 16 mm 볼트 접합부의 항복 전단내력은 약 20% 향상되었다.

유리섬유 보강집성재 볼트 접합부 전단내력 예측 (Estimate of Bolt Connection Strength of Reinforced Glulam using Glass Fiber)

  • 김건호;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.67-74
    • /
    • 2016
  • 유리섬유 보강집성재의 볼트접합부 항복전단내력을 예측하기 위해 인장형 전단시험을 통해 측정된 실측값과 설계기준에 의한 예측값을 비교하였다. 볼트접합부의 항복전단내력 예측식을 위해 층재의 방향별 탄성계수, 포아송비, 전단계수를 측정하였다. 설계기준의 예측식 보정을 위해 유리섬유 보강집성재의 파괴거동을 반영한 파괴인성계수($K_{ft}$)를 적용하여 보정항복전단내력을 비교하였다. 층재의 탄성계수는 섬유방향에 따라 연륜폭, 연륜각과 높은 상관관계를 보였다. 유리섬유 보강집성재의 보정항복전단내력은 직경과 보강재에 따라 실측치와 비슷한 경향을 보였으며, 직물형 유리섬유보강집성재의 볼트접합부가 가장 높은 내력성능을 보였다. 볼트직경과 보강재에 따른 유리섬유 보강집성재 볼트접합부의 항복전단내력은 건축구조설계기준의 제안식을 보정한 예측치가 가장 잘 일치하였다.

Evaluation of The Moment Resistance Joint Strength of Larch Glulam Using Glass Fiber Reinforced Wood Plate

  • Song, Yo-Jin;Jung, Hong-Ju;Park, Hyun-Ho;Lee, Hak-Young;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.571-578
    • /
    • 2014
  • As a way of developing wooden joint development, a glass fiber reinforced wood plate was manufactured to replace a steel plate. Also, the fracture toughness was evaluated. Through application to a cantilever-type specimen made of a column and a beam, the moment resistance performance was evaluated. For the fracture toughness specimen of the wood plate, 12 types were manufactured by varying the combination of a main member (veneer and plywood) and reinforcement (glass fiber sheet and glass fiber cloth). The results of the fracture toughness test indicated that the 5% yield load of the specimen using plywood was 18% higher than that of the specimen using veneer, and that the specimen reinforced by inserting glass fiber sheets between testing materials (Type-3-PS) had the highest average 5% yield load 4841 N. Thus, a moment resistance strength test was performed by applying Type-3-PS to a column-beam joint. The results of the test indicated that compared to the specimen using a steel plate and a drift pin (Type-A), the maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a drift pin (Type-B) was 0.79; and that a rupture occurred in the wood plate due to high stiffness of the drift pin. The maximum moment ratio of the specimen using a glass fiber reinforced wood plate (Type-3-PS) and a glass fiber reinforced wooden laminated pin (Type-C) was 0.67, which showed low performance. However, unlike Type-A, a ductile fracture occurred on Type-C, and the load gradually decreased even after the maximum moment.

잣나무 만곡 복합집성재의 휨강도 성능평가 (Performance Evaluation of Bending Strength of Curved Composite Glulams Made of Korean White Pine)

  • 송요진;정홍주;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권4호
    • /
    • pp.463-469
    • /
    • 2015
  • 본 연구에서는 잣나무 곡선부재의 휨 성능을 향상시키기 위하여 Glass fiber 소재의 보강재와 낙엽송 층재로 보강한 만곡 복합집성재를 제작하였다. 잣나무 만곡집성재는 보강유무 및 보강방법에 의하여 다섯 종류로 제작되었다. 대조시험편인 Type-A는 잣나무 층재로만 제작된 시험편이며, Type-B는 최외층에 잣나무 대신 동일한 두께의 국내산 낙엽송층재로 제작한 시험편이다. Type-C는 직물형태의 glass fiber cloth가 매 층재 사이에 삽입된 시험편이다. Type-D는 glass fiber cloth가 최외층재들의 안쪽과 바깥쪽에 2장씩 보강된 시험편이다. Type-E는 sheet 타입의 GFRP를 Type-D와 동일한 위치에 1장씩 보강한 시험편이다. 휨 강도 시험 결과, Type-A의 파괴계수와 비교하여 Type-B는 29%, Type-C는 6%, Type-E는 48% 증가되었으며 Type-D는 오히려 2% 감소하였다. 파괴모드에서 Type-A와 Type-B 그리고 Type-C는 최대하중에 도달하는 순간 완전히 파단되는 경향을 보였다. 그러나 Type-D와 Type-E는 보강재에 의해 파단이 억제되어 하중의 감소가 천천히 진행되었으며, 보강재 GFRP sheet(Type-E)는 압축응력과 인장응력에 대한 보강효과가 glass fiber cloth(Type-D)보다 양호한 것으로 확인되었다.

GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 문형라멘 구조의 수평가력 성능평가 (Lateral Load Performance Evaluation of Larch Glulam Portal Frames Using GFRP-Reinforced Laminated Plate and GFRP Rod)

  • 정홍주;송요진;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.30-39
    • /
    • 2016
  • 구조용 집성재 라멘 접합부에 일반적으로 사용되는 접합철물을 대신하여 단판과 Glass Fiber Reinforced Plastic (GFRP)를 복합시킨 GFRP 보강적층판과 삽입 접착형 GFRP rod를 접합물로 사용하여 낙엽송 집성재 문형라멘 구조의 수평가력 성능평가를 실시하였다. 실험결과 GFRP rod와 에폭시 접착제를 이용한 삽입 접착형 접합부는 기존의 접합철물을 이용한 실험체와 비교하여 항복내력, 종국내력, 초기강성이 각각 49%, 52%, 61% 낮게 측정되었다. 이러한 접합부는 GFRP rod와 집성재 간의 접착력이 중요한 내력 기구로 현장적용 시 문제가 발생할 수 있는 가능성이 크다고 판단된다. 반면, GFRP 보강적층판과 목재(Eucalyptus marginata)핀을 이용한 실험체는 집성재 슬릿 접합부의 단면적 손실이 큼에도 불구하고 항복내력, 종국내력, 초기강성, 소성률이 전부 3% 이내로 측정되었다. 게다가 사이클에 대한 강성변화율도 35%로 가장 낮게 측정되며 접합철물을 이용한 실험체와 거의 동등한 성능을 발휘한 것을 확인하였다.

GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 접합부의 모멘트저항 성능평가 (Moment Resistance Performance Evaluation of Larch Glulam Joints using GFRP-reinforced Laminated Plate and GFRP Rod)

  • 정홍주;송요진;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.40-47
    • /
    • 2016
  • 구조용 집성재 라멘 접합부에 일반적으로 사용되는 접합철물을 대신하여 단판과 GFRP (Glass Fiber Reinforced Plastic)를 복합시킨 GFRP 보강적층판과 삽입 접착형 GFRP rod를 접합물로 사용하였다. 이들을 적용시킨 접합부에 대한 모멘트저항 성능평가 결과, 접합철물을 이용한 실험체(Type-1)와 비교하여 GFRP 보강적층판과 GFRP rod 핀을 사용한 실험체의 항복모멘트는 4% 낮게 측정되었으나 회전강성은 29% 높게 측정되었다. 또한 GFRP 보강적층판과 목재(Eucalyptus marginata)핀을 사용한 실험체는 Type-1 실험체와 비교하여 항복모멘트 11%, 회전강성 56% 높게 측정되며 가장 양호한 성능을 나타냈었다. 파괴형상과 완전탄소성 분석을 통해서도 핀에 의한 전단내력으로부터의 취성파괴가 아닌 연성거동을 나타내며, 접합내력이 상승하고 부재의 일체화가 이루어짐을 확인하였다. 반면, GFRP rod를 삽입 접착한 실험체는 접착 불량으로 측정이 불가하거나 접합성능이 매우 낮게 측정되었다.

초산비닐수지계 접착제를 사용한 유리섬유강화플라스틱 복합집성재의 강도 성능 평가 (Strength Properties of GFRP Reinforced Glulam Beams Bonded with Polyvinyl Acetate-Based Emulsion Adhesive)

  • 박준철;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권4호
    • /
    • pp.19-25
    • /
    • 2008
  • 유리섬유강화플라스틱(GFRP : Glass fiber reinforced plastic) 보강 집성재를 제작한 후 유리섬유강화플라스틱의 체적비에 따른 휨강도 성능을 평가하였다. 집성재 제작에는 평균함수율 8%, 비중 0.54의 국산 낙엽송(Larix kaempferi Carr.) 제재판($2cm(h){\times}10cm(b){\times}360cm(l)$)을 7층으로 적층하여 집성재($10cm(b){\times}14cm(h){\times}180cm(l)$)를 제작하였다. 유리섬유강화플라스틱은 인장응력을 받는 하층의 최외각층과 윗층 사이에 두께 0.1 cm (체적비 0.7%)와 0.3 cm (체적비 2.1%)로 보강하였다. 유리섬유강화플라스틱을 체적비 0.7% 보강한 집성재의 경우 Control 집성재보다 휨강도가 12% 정도 증가하였으며 체적비 2.1%를 보강한 집성재의 경우 휨강도가 28% 정도 증가하였다. 또한, 유리섬유강화플라스틱 보강층이 파단의 진행을 억제하였으며 파괴되지 않은 부분은 약 90%의 휨강도를 유지하고 있었다. 접착성능 평가 결과 블록 전단 강도는 KS F3021의 합격기준 $7.1N/mm^2$를 만족하였으며 침지박리시험과 삶음박리시험 결과 박리율 5% 이하로 접착성능도 양호하였다.