• Title/Summary/Keyword: gc/ms

Search Result 2,427, Processing Time 0.027 seconds

Analytical method of the polychlorinated biphenyls in soil using GC/ECD and GC/MS (GC/ECD 및 GC/MS을 이용한 토양 중 PCBs 분석방법 고찰)

  • Kim, Tae-Seung;Shin, Sun-Kyoung;Yoon, Jeong-Ki;Kim, Jong-Ha;Kim, Hyoung Seop;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study was investigated both the Korean official soil test method and the international various methods for PCBs in soil sample. The analytical guideline of PCBs in contaminated soil were proposed based on the official soil test methods by discussing the extraction, column cleanup, instrumental conditions, quantification methods of peak matching and individual isomers. The total 28 soil samples were selected by consideration of PCBs-contamination, land use etc., and then analyzed using gas chromatography/electron capture detection (GC/ECD) and gas chromatography/mass spectrometry(GC/MS). In this study, the PCBs were not detected as peak matching method using GC/ECD, but PCBs detected $0.002{\sim}0.487{\mu}g/kg$ using GC/MS in background concentrations.

Feasibility study of membrane interface for gas chromatograph-mass spectrometry (기체크로마토그래프-질량분석기의 실리콘 분리막 인터페이스의 유용성 연구)

  • Kang, Gil Seon;Lee, Dong Soo;Lee, Hwa Sim;Park, Chang Joon
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.495-501
    • /
    • 2008
  • Agilent 5973 GC-MS instrument was modified so that the capillary direct interface was removed and that a silicone membrane was installed between GC and MS. Feasibility study of the membrane interface GC-MS has been carried out. Vacuum of the mass spectrometer was not affected by the carrier gas flow rate up to $4.7m{\ell}/min$. As the carrier flow rate was increased, peak tailing was reduced and chromatogram peaks appeared earlier. Chromatogram peaks showed better separation and higher sensitivity as the membrane thickness was reduced from $127{\mu}m$ to $75{\mu}m$, and also as the interface temperature was increased. However, the membrane interface GC-MS had drawbacks such as background ions at 73 and 147 m/z and poor peak separation due to peak tailing.

A Study on the Identification of Phenol Production by GC/MS under Chemical Treatment of Industrial Wastewater (화학적 폐수처리 중 GC/MS에 의한 폐놀생성 규명에 관한 연구)

  • 박선구;고오석;신대윤
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.89-93
    • /
    • 2000
  • Twenty organic chemical substances(Table 2) were isolated from untreated wastewater, as well as treated wastewater, collected at 76 companys of 9 industry group located in the basin of Youngsan River. Those organic compounds were analyzed by Gas Chromatography/Mass Spectrometry(GC/MS) and confirmed through comparison with each standard reagents. Phenol, which was not detected in the raw wastewater, was identified in the effluent of treatment facility, indicating that phenol is generated from isopropylbenzene of plant wastewater.

  • PDF

Fire Debris Analysis by GC/MS (GC/MS를 이용한 화재현장증거물의 분석)

  • Han, Dong-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.37-40
    • /
    • 2011
  • 화재현장에서는 화재의 원인으로 간주되는 여러 가지 증거물이 발생한다. 이러한 증거물을 분석하기 위한 수단으로 GC/MS의 역할은 아주 크며, 이를 이용한 증거물의 분석에 관한 표준으로 ASTM 1618-10과 전처리법을 소개한다. 또한 전처리법에 따른 여러 가지 종류의 유류의 특성을 알아보고 유류 성분을 포함한 화재증거물의 실제 사례를 들어 보겠다. 아울러 화재현장에서의 가연물로 추정되는 물질에 대하여 열분해를 통한 GC/MS 분석 사례도 제시하여 본다.

  • PDF

Confirming Animal Glue in Dancheong Sample by Pyrolysis/GC/MS (열분해/GC/MS에 의한 재현 단청 시편에서 아교의 확인)

  • Park, Jong Seo;Kim, Mi Jeong;Kim, Soon Kwan
    • Journal of Conservation Science
    • /
    • v.32 no.1
    • /
    • pp.21-32
    • /
    • 2016
  • Animal glue is a traditional material used extensively as adhesive and binder in mother-of-pearl, wooden structure, traditional painting, etc. Analysis of animal glue is usually performed with IR(infrared spectroscopy) based on the IR absorption of functional group. But, it has a limitation in confirming animal glue when a sample consists of several materials because of overlapping of the absorption band. Py/GC/MS(pyrolysis/gas chromatography/mass spectrometry) is a useful tool in analyzing the constituent of polymeric materials like animal glue by identifying their pyrolysate with very small amount of sample. In this study, confirmation of animal glue in a Dancheong sample was tried with this method. Characteristic pyrolytic compounds of animal glue and tung oil used in Dancheong were identified. Dancheong sample painted with Noerok as a coloring material, animal glue and tung oil was prepared and it was possible to find characteristic peaks of animal glue after thermal degradation and artificial weathering experiment. From this, we found that animal glue can be detected using py/GC/MS in cultural heritage samples consisting of several materials and in different condition. IR was also tried to analyze Dancheong sample and the results were compared with those of py/GC/MS for the detection of animal glue.

Development of a GC-MS Automatic Analysis Program to Provide Information on Exposure to Chemical Substances (화학물질 노출정보 제공을 위한 GC-MS 분석자동화 프로그램 개발)

  • Park, Seung-Hyun;Park, Hae Dong;Jang, Miyeon;Ro, Jiwon;Cho, Hyounmin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.1
    • /
    • pp.1-12
    • /
    • 2021
  • Objective: The purpose of this study was to contribute to the prevention of occupational diseases through the development of an automatic analysis program for evaluating workers' exposure to hazardous chemical substances. Methods: The authors selected chemical substances that caused occupational disease in Korea and chemical substances that are frequently used in industrial sites as target substances for a GC-MS automatic analysis program. The target substances are organic compounds which can be measured by a passive sampler. The automatic analysis program was studied using various raw data obtained from GC-MS analysis for the target substances. Results: A total of 48 organic compounds that can be measured with a passive sampler were selected as target substances for the GC-MS automatic analysis program. The selected compounds included substances that caused occupational disease, substances related to C1 and D1 in special health examinations, and substances for which work environment measurements have been frequently conducted. The GC-MS automatic analysis program was developed by combining information mainly on retention time and mass spectrum. The GC-MS automatic analysis program is designed to analyze unknown samples by comparing the mass spectrum and retention time of the samples to those of reference materials. To evaluate the stability of the program, samples at about the 30-50% level of OELs were prepared and analyzed with the GC-MS automatic analysis program, resulting in stable results for all 48 organic compounds. Conclusion: An automatic analysis program for a total of 48 organic compounds was developed using a GC-MS system that can analyze organic compounds. Unknown samples that contain the 48 organic compounds can be automatically analyzed by the developed program. It is anticipated that it can contribute to the prevention of occupational diseases through an GC-MS automatic analysis program that can quickly provide workers with information on exposure to chemical substances.

Determination of Radiolysis Produce of DHOA by GC/MS (GC/MS를 이용한 DHOA의 방사선 분해생성물 분석)

  • Yang, Han-Beom;Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Kim, Kwang-Wook;Kim, Jong-Seung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • Dihexyloctanamide(DHOA) was used as an extractant or phase modifier with the diamide extractants in a solvent extraction process for a radioactive liquid waste treatment. The degradation compounds of the DHOA extractant, irradiated with $^{60}Co$ gamma ray, were octanoic acid and dihexylamine which are identified by a Fourier transform infrared(FT-IR) and gas chromatograph/mass spectrometer(GC/MS) analysis, and determined by the GC/MS with selected ion monitoring(SIM) mode. Retention behavior of octanoic acid, tridecane (internal standard) and dihexylamine in total ion chromatogram (TIC) were 8.65 min., 9.79 min., and 10.27 min., respectively. With increasing the absorbed dose of the $\gamma$-ray irradiated DHOA, the concentration of octanoic acid was decreased and that of dihexylamine was increased.

  • PDF

Organic Material Analysis of a Lacquered Wooden Sheath of Long Sword with Ring Pommel Excavated in Imdang Ancient Tomb (경산 임당고분 출토 철제 고리자루칼 칠의 유기물 분석)

  • Park, Jongseo;Cho, Ha-nui;Lee, Jae-sung
    • Journal of Conservation Science
    • /
    • v.34 no.5
    • /
    • pp.369-377
    • /
    • 2018
  • In order to examine the constituents and weathered state of a lacquer specimen, analysis of the organic materials was conducted using py/GC/MS(pyrolysis-gas chromatography-mass spectrometry). The samples were obtained from the lacquered wooden sheath of a long ring-pommel sword excavated in the Imdang No.1 ancient tomb constructed around the Proto-Three Kingdoms period. In direct py/GC/MS, the sample and the dried Asian lacquer showed similar chromatograms, while the characteristic compounds of Asian lacquer such as 1,2-dimethoxy-3-pentadecylbenzene were observed in THM(thermally assisted hydrolysis and methylation)-py/GC/MS. In addition, compounds like dimethyl nonanedioate, which presumably originated from drying oil, were also detected. Furthermore, the detection of oxidized catechols in considerable amount indicated that the degradation of lacquer is estimated to result from the oxidation of urushiol. Therefore, it is suggested that the lacquered wooden sheath was prepared using Asian lacquer and drying oil, and that the lacquer layer was considerably oxidized over the long burial time.

A Study on the Analysis of Ingredients and Safety of Darkening Shampoo using Gas Chromatography Mass Spectrometer (GC-MS) (기체 크로마토그래피 질량 분석법을 이용한 다크닝 샴푸의 성분 분석 및 안전성에 관한 연구)

  • Yuri Kim;Woonjung, Kim
    • Industry Promotion Research
    • /
    • v.9 no.1
    • /
    • pp.13-20
    • /
    • 2024
  • In this study, we conducted a compositional analysis of five darkening shampoos available in the South Korean market and evaluated their active ingredients and safety based on the analysis results. GC-MS analysis was employed to identify the main components of each shampoo, revealing discrepancies between the detected compounds and the ingredient lists provided by the manufacturers. These differences are interpreted as being due to the limitations of the GC-MS analysis and the volatility of certain compounds. Further investigations were carried out to explore compounds potentially contributing to hair darkening. However, it was not definitively concluded that these compounds are directly involved in the hair darkening process. It is speculated that they may enhance hair care product performance and offer additional benefits to hair, or improve product texture, stability, or preservation. Additionally, the GC-MS analysis identified several compounds with potential safety concerns, necessitating caution when used as cosmetic ingredients.

Gas Chromatography-High Resolution Tandem Mass Spectrometry Using a GC-APPI-LIT Orbitrap for Complex Volatile Compounds Analysis

  • Lee, Young-Jin;Smith, Erica A.;Jun, Ji-Hyun
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.29-38
    • /
    • 2012
  • A new approach of volatile compounds analysis is proposed using a linear ion trap Orbitrap mass spectrometer coupled with gas chromatography through an atmospheric pressure photoionization interface. In the proposed GC-HRMS/MS approach, direct chemical composition analysis is made for the precursor ions in high resolution MS spectra and the structural identifications were made through the database search of high quality MS/MS spectra. Successful analysis of a complex perfume sample was demonstrated and compared with GC-EI-Q and GC-EI-TOF. The current approach is complementary to conventional GC-EI-MS analysis and can identify low abundance co-eluting compounds. Toluene co-sprayed as a dopant through API probe significantly enhanced ionization of certain compounds and reduced oxidation during the ionization.