• Title/Summary/Keyword: gate operation

Search Result 820, Processing Time 0.033 seconds

OPTIMUM STORAGE REALLOCATION AND GATE OPERATION IN MULTIPURPOSE RESERVOIRS

  • Hamid Moradkhani
    • Water Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.57-62
    • /
    • 2002
  • This research is intended to integrate long-term operation rules and real time operation policy for conservation & flood control in a reservoir. The familiar Yield model has been modified and used to provide long-term rule curves. The model employs linear programming technique under given physical conditions, i.e., total capacity, dead storage, spillways, outlet capacity and their respective elevations to find required and desired minimum storage fur different demands. To investigate the system behavior resulting from the above-mentioned operating policy, i.e., the rule curves, the simulation model was used. Results of the simulation model show that the results of the optimization model are indeed valid. After confirmation of the above mentioned rule curves by the simulation models, gate operation procedure was merged with the long term operation rules to determine the optimum reservoir operating policy. In the gate operation procedure, operating policy in downstream flood plain, i.e., determination of damaging and non-damaging discharges in flood plain, peak floods, which could be routed by reservoir, are determined. Also outflow hydrograph and variations of water surface levels for two known hydrographs are determined. To examine efficiency of the above-mentioned models and their ability in determining the optimum operation policy, Esteghlal reservoir in Iran was analyzed as a case study. A numerical model fur the solution of two-dimensional dam break problems using fractional step method is developed on unstructured grid. The model is based on second-order Weighted Averaged Flux(WAF) scheme with HLLC approximate Riemann solver. To control the nonphysical oscillations associated with second-order accuracy, TVD scheme with SUPERBEE limiter is used. The developed model is verified by comparing the computational solutions with analytic solutions in idealized test cases. Very good agreements have been achieved in the verifications.

  • PDF

- Optimizing Gate Assignment and Operation Support System for Reliability Improvement of Airport - (공항의 신뢰성 향상을 위한 최적 주기장 배정과 운영지원시스템)

  • Lee Hee Nahm;Lee Chang Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.4
    • /
    • pp.215-226
    • /
    • 2004
  • This study develops a improved gate assignment algorithm and decision support system using its algorithm to extract a assignment result minimizing a walking distance of passengers in airport and maximizing the utilization rate of avaliable gates in domestic airports. By operation support system, it may contribute greatly in efficient enlargement of airport operation and increase the airport reliability through quickly coping with takeoff and landing delay of flight due to weather change, preservation and repair of gate, etc. Also, passengers who use airport terminal can minimize time and walking distance for departure, arrival, and transit, and it may greatly reduce the additional operation cost for common gates through maximizing the utilization rate for exclusive usage gates for airplanes which use gates.

Optimizing Gate Assignment and Operation Support System for Reliability Improvement of Airport (공항의 신뢰성 향상을 위한 최적 주기장 배정과 운영지원시스템)

  • Lee HeeNahm;Lee ChangHo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.221-227
    • /
    • 2004
  • This study develops a improved gate assignment algorithm and decision support system using its algorithm to extract a assignment result minimizing a walking distance of passengers in airport and maximizing the utilization rate of avaliable gates in domestic airports. By operation support system, it may contribute greatly in efficient enlargement of airport operation and increase the airport reliability through quickly coping with takeoff and landing delay of flight due to weather change, preservation and repair of gate, etc. Also, passengers who use airport terminal can minimize time and walking distance for departure, arrival, and transit, and it may greatly reduce the additional operation cost for common gates through maximizing the utilization rate for exclusive usage gates for airplanes which use gates.

  • PDF

An Analysis for Gate-source Voltage of GaN HEMT Focused on Mutual Switch Effect in Half-Bridge Structure (GaN HEMT를 사용한 Half-Bridge 구조에서의 스위치 상호작용에 의한 게이트 전압분석)

  • Chae, Hun-Gyu;Kim, Dong-Hee;Kim, Min-Jung;Lee, Byoung Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1664-1671
    • /
    • 2016
  • This paper presents the analysis of the gate-source voltage of the gallium nitride high electronic mobility transistor (GaN HEMT) in the half bridge structure focused on the mutual effects of two switching operation. Especially low side gate-source voltage is analyzed mathematically according to the high side switch turn-on and turn-off operation. Moreover, the influence of each gate resistance and parasitic component on the switching characteristic of other side switch is investigated, and the formula, simulation and experimental results are compared with theoretical data.

Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate (전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

Driving Methods of LCD-TV Using a-Si:H TFT Integrated Gate Drivers

  • Lee, Chang-Soo;Lee, Min-Cheol;Lee, Yong-Soon;Bae, Yu-Han;Kim, Young-Su;Moon, Seung-Hwan;Kim, Nam-Deog;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.280-283
    • /
    • 2008
  • LCD-TV applications were successfully implemented using integrated gate drivers. Integrated gate drivers have been implemented on a HD panel for 60Hz operation and on a FHD panel for 120Hz operation. It is found that the integrated gate driver reduces the flicker of a panel.

  • PDF

CoolSiCTM SiC MOSFET Technology, Device and Application

  • Ma, Kwokwai
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.577-595
    • /
    • 2017
  • ${\bullet}$ Silicon Carbide (SiC) had excellent material properties as the base material for next generation of power semiconductor. In developing SiC MOSFET, gate oxide reliability issues had to be first overcome before commercial application. Besides, a high and stable gate-source voltage threshold $V_{GS(th)}$ is also an important parameter for operation robustness. SiC MOSFET with such characteristics can directly use existing high-speed IGBT gate driver IC's. ${\bullet}$ The linear voltage drop characteristics of SiC MOSFET will bring lower conduction loss averaged over full AC cycle compared to similarly rate IGBT. Lower switching loss enable higher switching frequency. Using package with auxiliary source terminal for gate driving will further reduce switching losses. Dynamic characteristics can fully controlled by simple gate resistors. ${\bullet}$ The low switching losses characteristics of SiC MOSFET can substantially reduce power losses in high switching frequency operation. Significant power loss reduction is also possible even at low switching frequency and low switching speed. in T-type 3-level topology, SiC MOSFET solution enable three times higher switching freqeuncy at same efficiency.

  • PDF

Simulation of Turbid Water in the Stratified Daecheong Reservoir during Gate Operation (댐 배수조작에 따른 저수지내 탁수변화 모의 - 대청댐을 대상으로 -)

  • Lee, Jae-Yil;Seo, Se-Deok;Lee, Gyu-Sung;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.377-386
    • /
    • 2009
  • Due to severe flooding, the long-term residence of turbidity flows within the stratified Daecheong Reservoir have lengthened. A long-term residence of turbidity flows within the stratified Daecheong Reservoir after floods has been major environmental issue. The objective of this study was to assess the impact to water supply from the hydrodynamics and turbidity outflow. Two gate operation scenarios were investigated. Scenario A refers to gate operations according to rainfall events, and scenario B refers to gate operations according to inflow. From the results of secenario A, the SS concentrations decreased from 0.44mg/l to 0.54mg/l at the front of the dam, whereas SS concentrations increased from 0.24mg/l to 1.24mg/l at the intake points at Munhi and Daejeon. From the results of scenario B, the SS concentrations decreased from 0.61mg/l to 0.83mg/l at the front of Dam; howeve, SS concentrations also decreased from 0.16mg/l to 0.48mg/l at the intake points at Munhi and Daejeon. It seems that it may be more efficient to control turbidity by creating additional outflows of generated discharge after intensive rainfalls than not.

Two-dimensional Numerical Modeling of Water Quality Variation by Gates Operation in the Seonakdong River (수문운영에 따른 서낙동강 수질변화에 관한 이차원 수치모의)

  • Lee, Namjoo;Kim, Young Do;Kwon, Jae Hyun;Shin, Chan Ki
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.101-112
    • /
    • 2007
  • This study has used RMA2 model and RMA4 model, which are depth-averaged two-dimensional flow and water-quality prediction models, to analyze the variation of the water-quality by the gates operation in the Seonakdong River. Sensitivity analysis is performed to get the Manning coefficient and the coefficient of eddy viscosity for RMA2 model, and to get the diffusion coefficient for RMA4 model. Since the numerical simulation using RMA2 and RMA4 models did not consider tributary pollutant load except for that of Joman River, it could make a little difference from the natural phenomenon. Nevertheless, the numerical simulation shows that the discharge of $30m^3/s$, which is the continuous inflow from the Daedong-gate, can make it possible to achieve the target water-quality (BOD 4.3mg/L) of Nakbon-N watershed about 10 days later if the Daejeo-gate could remain opened in connection with the Noksan-gate operation.