• Title/Summary/Keyword: gas tightness

Search Result 41, Processing Time 0.026 seconds

Development of Static Seal for a Liquid Rocket Engine (액체 로켓 엔진 스태틱 실 개발)

  • Jeon, Seong Min;Yoon, Suk-Hwan;Chung, Taegeum
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.53-59
    • /
    • 2022
  • Static seals are used to seal high temperature gas and cryogenic fluid under high pressure, at interfaces between liquid rocket engine components such as combustion chamber, turbopump, gas generator, valves, etc. As thermal expansion and contraction at assembly interfaces cause undesirable leakage under cryogenic and high temperature environments, static seals applied for sealing of joint interfaces without relative motion should be designed properly. The additional function of rotation at the sealing face is also required for static seals, when the spherical flange is used for improvement of assembly at misalignment interfaces. In this study, structural analysis and leak tightness test of simulating test rig for several important interfaces are performed, to verify structural integrity of static seals.

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

Analysis of the Edge Sealing Strength for Vacuum Glass Panel Using Design of Experiment (실험계획법을 이용한 진공유리 패널 모서리 용융 접합 강도실험 분석)

  • Kim, Seung-Jong;Jeon, Euy-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1819-1824
    • /
    • 2014
  • The vacuum-glazing panel is a panel that keeps two glasses completely sealed in a vacuum condition. It is the high function insulation material of having the wall level minimizing the heat loss by the conduction and convection heat transmission coefficient. The edge sealing is a very important process of vacuum glass on the strength, thickness and air tightness. In this study, by using the hydrogen mixture gas torch, two sheets of glass was sealing in the furnace. The thickness and strength of the glass according to the process parameters is measurement and analysis, and predicting the edge sealing strength of glass by using taguchi method of experiment. We verified the validity of the experiment by checking the error rate through additional experiment.

Estimation of Water Leak Rate in the Underground Oil Storage Cavern (지하 원유 저장공동에서의 누수량 산정에 대한 연구)

  • Shim, Hyun-Jin;Park, Tae-Jun;Jeong, Woo-Cheol;Kim, Ho-Yeong;Choi, Young-Tae
    • Tunnel and Underground Space
    • /
    • v.20 no.4
    • /
    • pp.233-240
    • /
    • 2010
  • Double Plug is constructed for preventing mixing of two different oils between two compartments in the underground oil storage cavern. And the gas and oil tightness of double plug is tested from the measurement of water leakage from double plug after the completion of double plug water filling. If water leakage is underestimated, it can increase construction cost and if water leakage is overestimated, it can increase operating cost. Therefore, optimum water leakage should be estimated to cut down the cost. In this study, hydraulic stability analysis was conducted to consider permeable properties of rock mass around double plugs and a water leak rate from double plug was estimated from the hydraulic stability analysis and case study. Finally, the reliability of estimation of water leak rate was proven by comparing estimated water leak rate with measured data.

Uncertainty Analysis for Head and Gradient Incorporating Spatial Nonuniformity of Hydraulic Conductivity around Underground Storage Caverns (지하공동주변 수리전도도의 불균일성을 도입한 수두 및 동수경사의 불확실성 해석)

  • Jeong, Il-Mun;Jo, Won-Cheol;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.5
    • /
    • pp.553-564
    • /
    • 1998
  • For the proper design and management of underground storage cavern, groundwater flow around cavern should be analyzed. Since this flow is influenced by spatial nonuniformity of hudraulic conductivity, the two-dimensional finite element flow model incorporating stochastic concepts was developed to analyze influences due to this nonuniformity. Monte Carlo technique was applied to obtain an approximate solution for two-dimensional, steady flow in a stochastically defined nonuniform medisu. For this purpose, the values of hydraulic conductivity were generated for each element with known mean and standard deviations. The uncertainty in model prediction depends on both the nonuniformity in hydraulic conductivity and the natures of the flow system such as water curtain and boundary condition. Therefore the uncertainties in predicted hydraulic head and gradient are the greatest where the mean hydraulic gradients are relatively large and far from the boundaries. Especially, we relate these uncertainties with well known gas tightness condition.

  • PDF

High Pressure Spray and Combustion Characteristics of Throttleable Pintle Injector (가변추력 핀틀 분사기의 고압 분무 및 연소특성)

  • Kim, Dae Hwan;Heo, Subeom;Kim, Inho;Hwang, Donghyun;Kang, Cheolwoong;Lee, Shinwoo;Ahn, Kyubok;Yoon, Youngbin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.2
    • /
    • pp.60-71
    • /
    • 2022
  • The reusable, low-cost launch vehicle development trend in the recent launch vehicle market is being subdivided into several ways, and the throttleable engine is one of them. Plus, several nations have selected methane as a next-generation propellant due to its cleanness. In this research, a throttleable pintle injector using gas methane and liquid oxygen as propellants was developed, followed by its spray and combustion characteristics analysis, including high pressure cold and hot tests. The designed throttleable pintle injector has a double sleeve structure, and its tightness and functionality are confirmed through repetitive atmospheric, high-pressure cold tests, and hot tests. Though some design errors were discovered and a low throttling level was unable to be achieved in the combustion test.

Air-tightness Test by Silicagel on Museum Cases (조습제(燥濕濟)(Art-Sorb)를 이용한 벽부형진열장(壁附形陳列欌) 밀폐도(密閉度) 간접측정(間接測淀))

  • Yu, Hei-sun;Kim, Myoung-nam;Lee, Sung-eun
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.71-78
    • /
    • 2001
  • The airtightness of museum cases in museums was measured by using CO2 tracing gas, but it has been pointed that it has a problem with measuring the airtightness of a museum case which has a hole inside before it is used or while is being used. So studies tried to come up with alternatives which make it possible to measure the airtightness of a museum case before it is used or while it is being used if necessary by indirectly measuring the airtightness of the museum case without changing its form. Indirect measuring is done by measuring the change of Art-sorb weight and the change of temperature and humidity inside the museum case. Experiments were made for 12 days with three builtin wall case installed at the same place without turning on the lights but with Art-sorb and the data logger of temperature and humidity put into museum case. The change rate was produced with the change of temperature and humidity inside the museum case divided by that of those around museum case. As a result, the temperature change rate of museum case A(0.67) was lower than that of museum case B(0.69) or museum case C(0.79). The humidity change rate of museum case A(0.12) was lower than that of museum case B(0.19) or museum case C(0.72) showing that its airtightness was the best. Also in the direct airtightness measurement by CO2 tracing gas, the air exchange rate was compared with the humidity change rate by Art-sorb in the indirect measurement.

Assembly and Test of the In-cryostat Helium Line for KSTAR (KSTAR 저온용기 내부의 헬륨라인 설치 및 검사)

  • Bang, E.N.;Park, H.T.;Lee, Y.J.;Park, Y.M.;Choi, C.H.;Bak, J.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • In-cryostat helium lines are under installation to transfer a cryogenic helium into cold components in KSTAR device. In KSTAR, three kinds of helium should be supplied into the cold components, which are supercritical helium Into superconduction(SC) magnet system, liquid helium into current lead system, and gas helium into thermal shields. Cryogenic helium lines consist of transfer lines outside the cryostat, in-cryostat helium lines, and electrical breaks. In-cryostat helium lines should be guaranteed of leak tightness for tong time operation at high internal helium pressure of 20 bar. We wrapped the helium line with multi-layer insulator(MLI) to reduce radiation heat and insulated the surface of the high potential part with prepreg tape. The electrical break was fabricated by brazing ceramic tube with stainless steel tube. To ensure the operation reliability at operation temperature, all the electrical break have been examined by the thermal cycle test at liquid nitrogen and by the hydraulic test at 30 bar. And additional surface insulation was prepared with prepreg tape to give structural safety. At present most of the in-cryostat helium lines have been installed and the final inspection test is progressing.

Development of Pressure Correction System for Surface Vessel to Ensure Reliability of Compartment Test Result (수상함 격실기밀시험 결과의 신뢰성 확보를 위한 압력 보정 시스템 개발)

  • Min, Il-Hong;Kim, Jun-Woo;Son, Gi-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.409-414
    • /
    • 2021
  • Tightness performance that blocks compartments is important for surface ships to achieve superior mission performance and survivability in combat environments. To meet the above requirements, airtightness of the structural elements and the appropriate strength to specific areas are checked during a test run after ship construction. In particular, air tests of compartments adjacent to the water surface are performed. In an air test, air is injected into the compartment up to the test pressure of the test memo. The pressure drop value is checked after 10 minutes to determine if the requirements of the corresponding area are satisfied. In summer, however, when the influence of the outside temperature is large, a phenomenon in which the internal pressure increases during the air test was identified. This phenomenon reduces the reliability of the test result. Therefore, a system was designed to compensate for temperature changes in the compartments through this study. The developed system calculates the amount of pressure change caused by a temperature change in the compartment and outputs a correction value. The pressure change was calculated using the ideal gas equation, reflecting the maintenance, increase, and decrease in temperature during the test process. A comparison of the calculated pressure correction value with the database of NIST REFPROP revealed a difference of 0.126% to a maximum of 0.253%.

Study on establishment of emission cell test method for liquid phase building materials (방출셀을 이용한 액상건축자재 오염물질 방출시험방법 정립에 관한 연구)

  • Lim, Jungyun;Jang, Seongki;Seo, Sooyun
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • The aim of this study was to evaluate and establish of emission test method for liquid phase building materials such as paint, adhesive, sealant by emission cell. A small-scale emission chamber and emission cell were used to evaluate emission of TVOC from paint, adhesive, sealant. The quantity of TVOC emission were measured by a gas chromatography/mass spectrometry (GC/MS). Background concentration of TVOC was below $10{\mu}g/m^3$ in the emission chamber and cell. Air tightness and recovery in chamber and cell showed good results. The recovery of thermal desorber for toluene and n-dodecane were about 120%. The repeatability of response factor and retention time in GC/MS below 30%. The method detection limit of VOCs ranged 0.04~8.82 ng. The concentration of TVOC emission using emission cell was 1.35~1.41 times higher than emission chamber. The correlation of TVOC emission using chamber and cell method was significantly high (r=0.91~0.97).