• Title/Summary/Keyword: gas selectivity

Search Result 670, Processing Time 0.04 seconds

Process Design and Performance Test of the SCR Pilot Plant (SCR Pilot Plant 성능실험 및 공정 설계)

  • Kim, Jeong-Il;Chang, In-Gab;Seon, Chil-Yeong;Moon, Kil-Ho
    • Clean Technology
    • /
    • v.9 no.2
    • /
    • pp.71-79
    • /
    • 2003
  • The selective catalytic reduction (SCR) process is the most widely applied technology for the denitrification of coal-fired power plant flue gases due to its selectivity and high efficiency. In order to attain the optimum design of SCR process, it is required to consider various catalysis characteristics as well as various operating conditions. A systematic study to elucidate the effects of the design conditions(reaction temperature, $NH_3/NO$ mole ratio, space velocity and linear velocity) on the reduction of NOx using the SCR pilot plant with maximum flue gas flow rate of $1,000Nm^3/hr$ was carried out and employed to identify the optimum design parameters. Design approaches of SCR process with test results were also presented.

  • PDF

In-situ Growth Synthesis of ZIF-8 Membranes and their H2/CO2 Separation Properties (In-situ 성장법에 의한 ZIF-8 분리막 합성 및 H2/CO2 분리 특성)

  • Lee, Jeong Hee;Yoo, Sung Jong;Kim, Jinsoo
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.129-135
    • /
    • 2018
  • ZIFs (Zeolitic imdazolate frameworks) have attracted great attention as membrane materials in recent years due to their high chemical and thermal stability, high specific surface area and adjustable pore structure. In this study, ZIF-8 membranes were synthesized by in-situ growth method on two different support materials (${\alpha}$-alumina and YSZ) and their $H_2/CO_2$ gas permeation characteristics were investigated. In order to synthesize defect-free ZIF-8 layer, YSZ support required less synthesis time than ${\alpha}$-alumina support due to smaller pore size. After in-situ growth for 3 h, ZIF-8 membranes prepared on both YSZ and ${\alpha}$-alumina supports showed $H_2/CO_2$ selectivity of about 10.

Model-Based Analysis of the $ZrO_2$ Etching Mechanism in Inductively Coupled $BCl_3$/Ar and $BCl_3/CHF_3$/Ar Plasmas

  • Kim, Man-Su;Min, Nam-Ki;Yun, Sun-Jin;Lee, Hyun-Woo;Efremov, Alexander M.;Kwon, Kwang-Ho
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.383-393
    • /
    • 2008
  • The etching mechanism of $ZrO_2$ thin films and etch selectivity over some materials in both $BCl_3$/Ar and $BCl_3/CHF_3$/Ar plasmas are investigated using a combination of experimental and modeling methods. To obtain the data on plasma composition and fluxes of active species, global (0-dimensional) plasma models are developed with Langmuir probe diagnostics data. In $BCl_3$/Ar plasma, changes in gas mixing ratio result in non-linear changes of both densities and fluxes for Cl, $BCl_2$, and ${BCl_2}^+$. In this work, it is shown that the non-monotonic behavior of the $ZrO_2$ etch rate as a function of the $BCl_3$/Ar mixing ratio could be related to the ion-assisted etch mechanism and the ion-flux-limited etch regime. The addition of up to 33% $CHF_3$ to the $BCl_3$-rich $BCl_3$Ar plasma does not influence the $ZrO_2$ etch rate, but it non-monotonically changes the etch rates of both Si and $SiO_2$. The last effect can probably be associated with the corresponding behavior of the F atom density.

  • PDF

Solubilization of Mixture of Hydrocarbon Oils by C12E8 Nonionic Surfactant Solution (C12E8 비이온 계면활성제 수용액에 의한 탄화수소 오일 혼합물의 가용화 특성에 관한 연구)

  • Lim, JongChoo
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.59-65
    • /
    • 2008
  • The equilibrium solubilization capacity of the mixture of hydrocarbon oils by $C_{12}E_8$ nonionic surfactant micellar solution was measured at $23^{\circ}C$ by gas chromatography (GC) analysis. Experimental results indicated that the solubilization capacity for pure alkanes was found to decrease almost linearly with the alkane carbon number (ACN) of the hydrocarbon oil. For the binary mixture systems of the hydrocarbon oils both selective and nonselective solubilization behaviors were observed depending on the difference in ACN of the two hydrocarbon oils. Equilibrium solubilization tests for the hydrocarbon oil mixtures in $C_{12}E_8$ surfactant solutions such as the three n-octane/n-nonane, n-nonane/n-decane and n-decane/n-undecane mixture systems suggest almost non-selective solubilization. On the other hand, the n-octane/n-decane and n-octane/n-undecane systems, where difference in ACN of the two hydrocarbon oils is greater than 1, selective solubilization in favor of n-octane was conclusively demonstrated.

Effect of Water on the Kinetics of Nitric Oxides Reduction by Ammonia over V-based Catalyst (바나듐계 촉매상에서 암모니아를 이용한 질소산화물의 환원반응속도에 수분이 미치는 영향에 관한 연구)

  • Kim, Young-Deuk;Jeong, Soo-Jin;Kim, Woo-Seung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.6
    • /
    • pp.73-82
    • /
    • 2012
  • The main and side reactions of the three selective catalytic reduction (SCR) reactions with ammonia over a vanadium-based catalyst have been investigated using synthetic gas mixtures in the temperature range of $170{\sim}590^{\circ}C$. The three SCR reactions are standard SCR with pure NO, fast SCR with an equimolar mixture of NO and $NO_2$, and $NO_2$ SCR with pure $NO_2$. Vanadium based catalyst has no significant activity in NO oxidation to $NO_2$, while it has high activity for $NO_2$ decomposition at high temperatures. The selective catalytic oxidation of ammonia and the formation of nitrous oxide compete with the SCR reactions at the high temperatures. Water strongly inhibits the selective catalytic oxidation of ammonia and the formation of nitrous oxide, thus increasing the selectivity of the SCR reactions. However, the presence of water inhibits the SCR activity, most pronounced at low temperatures. In this study, the experimental results are analyzed by means of a dynamic one-dimensional isothermal heterogeneous plug-flow reactor (PFR) model according to the Eley-Rideal mechanism.

Detection and Quantitation of Residual Antibiotics and Antibacterial Agents in Foods

  • Ryu, Jae-Chun;Seo, Ja-Won;Song, Yun-Seon;Park, Jong-Sei
    • Journal of Food Hygiene and Safety
    • /
    • v.5 no.3
    • /
    • pp.159-164
    • /
    • 1990
  • To detect and quantitation residual antibiotics and antibacterial agents in meats, we performed a biological assay employing the three microorganisms Bacillus subtilis ATCC 6633, Micrococcus luteus ATCC 9341, and Bacillus cereus var. mycoides ATCC 11778 for the screening purpose and developed a Gas Chromatography-mass Spectrometry(GC/MS) analysis for the confirmation and quantiation. In the biological assay (paper disk method), three test solution are used depending on the character of the residual antibiotics and antibacterial agents, follow by a simple clean up procedure which includes homogenization with Mcilvaine buffer, defatting with includes homogenization with Mcilvaine buffer, defatting with hexane, extraction with chloroform, clean-up by Sep-Pak $C_{18}$ and Bakerbond SPE carboxylic acid column. The chloroform layer is used for the analysis of sulfa agents. macrolides antibiotics and antibacterial agents, Adsorbed materials in the Sep-Pak $C_{18}$ were also employed for th analysis of penicillins and tetracyclines. Effluents from the Sep-Pak $C_{18}$ were cleaned-up one more by Bakerbond 10 SPE COOH column and employed for the analysis of aminoglycosides. In the instrumental analysis by using the GC/MSD, residual antibiotics and antibacterial agent were quantitated by selected ion monitoring (SIM) mode after derivatization. A simultaneous analysis of six residual antibiotic and antibacterial agent such as oxytetracycline, penicillin, ampicillin, choliraphenicol and thiamphenicol was developed with simple cleanup procedures revealing good recovery and reproducibility. Also, simultaneous detection of macrolides antibiotics such as erythromycin, spiramycin, and oleandomycin was developed after acid hydrolysis due to their large molecular structures. Because of the high reproducibility and selectivity of these two methods, it is very desirable that the combination of the two methods be used in the bioassay for the screening of residual antibiotics and antibacterial agent and that GC/MSD analysis be used for the confirmation and quantitation.

  • PDF

Sensing Properties of ZrO2-added SnO2 for Nerve and Blister Agent (ZrO2 첨가된 SnO2를 이용한 신경 및 수포작용제 검지에 대한 연구)

  • Yun, Ky-Youl;Cha, Gun-Young;Choi, Nak-Jin;Lee, Duk-Dong;Kim, Jae-Chang;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.323-328
    • /
    • 2004
  • N-type semi-conducting oxides such as $SnO_{2}$, ZnO, and $ZrO_{2}$ have been known for the detecting materials of inflammable or toxic gases. Of those materials, $SnO_{2}$-based sensors are well known as high sensitive materials to detect toxic gases. And the sensitivity is improved if catalysts are added. Detecting toxic gases, especially DMMP (di-methyl-methyl-phosphonate) and DPGME (Dipropylene glycol methyl ether), was performed by a mixture of Tin oxide ($SnO_{2}$) and Zirconia ($ZrO_{2}$). The films consist of each three different mass% of Zr (from 1 mass% to 5 mass%), and they were tested by XRD, SEM, TEM, BET. Nano-structure, pore and particle size was controlled to verify the sensor's sensing mechanism. The sensors was evaluated at five different degrees (from $200^{\circ}C$ to $400^{\circ}C$) and three different concentrations (from 500 ppb to 1500 ppb). The sensors had good sensitivity of both simulants, and high selectivity of DMMP.

Etch Characteristics of CO/NH3 Plasma Gas for Magnetic Random Access Memory in Pulsed-biased Inductively Coupled Plasmas

  • Yang, Gyeong-Chae;Jeon, Min-Hwan;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.200-200
    • /
    • 2013
  • 기존 메모리 반도체에 비교해 빠른 재생속도와 높은 집적도, 비휘발성 등의 특성을 가지는 MRAM (Magnetic Random Access Memory)은 DRAM, flash memory 등을 대체할 수 있는 차세대 기억 소자로서 CoFeB/MgO/CoFeB로 구성된 한 개의 MTJ (Magnetic Tunnel Junction)를 단위 메모리로 사용한다. 이 MTJ 물질들은 고밀도 플라즈마를 이용한 건식 식각공정시 Cl2, BCl3 등과 같은 chlorine 을 포함한 가스를 이용하여 왔으나 식각 후 sidewall에서 발생하는 부식과 식각 선택비 확보의 어려움 등으로 마스크 물질에 제약을 받고 소자 특성이 감소하게 되는 등의 문제가 있다. 따라서 이러한 식각 문제점을 해결하기 위한 대안으로 noncorrosive 가스인 CO/NH3, CH3OH, CH4 등을 이용한 MTJ 식각 연구가 진행되어 오고 있으며 이중 CO/NH3 혼합가스는 부식성이 없고 hard mask와의 높은 선택비를 가지는 기체로 CO gas에 NH3 gas를 첨가하게 되면 etch rate이 증가하는 특성을 보인다. 또한 rf pulse-biased power를 이용하여 이온의 입사를 시간에 따라 제어함으로써 pulse off time 때 etch gas와 MTJ 물질간의 chemical reaction을 향상시킬 수 있다. 따라서 본 연구에서는 CO/NH3 혼합가스를 이용하여 다양한 rf pulse-biased power 조건에서 MTJ 물질인 CoFeB, MgO와 hard mask 물질인 W을 식각 한 뒤 식각특성을 분석하였으며 MTJ surface의 chemical binding state, surface roughness 측정을 진행하였다. 식각 샘플의 측정은 Alpha step profiler, XPS (X-ray Photoelectron Spectroscopy), AFM (Atomic Force Microscopy)를 통해 진행되었다. Time-averaged pulse bias에서는 duty ratio가 감소할수록 etch rate의 큰 감소 없이 CoFeB/W, MgO/W 물질의 etch selectivity가 향상됨을 확인할 수 있었으며 pulse off time 구간에서의 chemical reaction 향상으로 인해 식각부산물의 재증착이 감소하고 CoFeB의 surface roughness가 감소하는 것을 확인하였다.

  • PDF

Development and validation of a qualitative GC-MS method for methamphetamine and amphetamine in human urine using aqueous-phase ethyl chloroformate derivatization

  • Kim, Jiwoo;Sim, Yeong Eun;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • Methamphetamine (MA) is the most common and available drug of abuse in Korea and its primary metabolite is amphetamine (AP). Detection of AP derivatives, such as MA, AP, phentermine (PT), MDA, MDMA, and MDEA by the use of immunoassay screening is not reliable and accurate due to cross-reactivity and insufficient specificity/sensitivity. Therefore, the analytical process accepted by most urine drug-testing programs employs the two-step method with an initial screening test followed by a more specific confirmatory test if the specimen screens positive. In this study, a gas chromatography-mass spectrometric (GC-MS) method was developed and validated for confirmation of MA and AP in human urine. Urine sample (500 µL) was added with N-isopropylbenzylamine as internal standard and ethyl chloroformate as a derivatization reagent, and then extracted with 200 µL of ethyl acetate. Extracted samples were analysed with GC-MS in the SIM/ Scan mode, which were screened by Cobas c311 analyzer (Roche/Hitachi) to evaluate the efficiency as well as the compatibility of the GC-MS method. Qualitative method validation requirements for selectivity, limit of detection (LOD), precision, accuracy, and specificity/sensitivity were examined. These parameters were estimated on the basis of the most intense and characteristic ions in mass spectra of target compounds. Precision and accuracy were less than 5.2 % (RSD) and ±14.0 % (bias), respectively. The LODs were 3 ng/mL for MA and 1.5 ng/mL for AP. At the screening immunoassay had a sensitivity of 100% and a specificity of 95.1 % versus GC-MS for confirmatory testing. The applicability of the method was tested by the analysis of spiked urine and abusers' urine samples.

Chromogenic and Fluorogenic Polymer Systems for Optical Sensing and Patterning

  • Lee, Taek-Seung;Kim, Tae-Hyeon;Kim, Tae-Hoon;Choi, Moon-Soo;Kim, Hyung-Jun;Kwak, Chan-Gyu;Lee, Jung-Hyo;Lee, Chi-Han
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.175-175
    • /
    • 2006
  • Considering the number of chemosensors that have been developed for the sensing of metal ions, only a few chemosensors for fluoride anion have been described in the literature that are based on fluorescent or chromogenic responses. We performed colorimetric anion sensing based on the binding of anion analytes with hydrogen donor group in polymer backbone resulting in naked-eye color change and fluorescent quenching. Our challenges using hydrogen donor moiety was designed effectively are continuing in order for high selectivity and sensitivity for ultimate applications such as fluid solution sensing in biomolecules and gas vapor sensing.

  • PDF