• Title/Summary/Keyword: gas pipes

Search Result 274, Processing Time 0.021 seconds

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열교환 성능 분석(농업시설))

  • 서원명;강종국;윤용철;김정섭
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.333-339
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas funnel connected to combustion chamber of greenhouse heating system. The experiment heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas funnel, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amount by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air pipes and exhaust air passages crossing the pipes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through funnels.

  • PDF

Structural Integrity Assessments of Pressurized Pipes with Gouge using Stress-Modified Fracture Strain Criterion (삼축응력 기반의 파괴변형률 기준을 적용한 가우지 손상배관의 건전성 평가)

  • Oh C.K.;Kim Y.J.;Park J.M.;Baek J.H.;Kim Y.P.;Kim W.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.808-813
    • /
    • 2005
  • Structural integrity assessment of defected pipe is important in fitness for service evaluation and proper engineering assessment is needed to determine whether pipelines are still fit for service. This paper present a failure prediction of gas pipes made of APIl X65 steel with gouge using stress-modified true fracture strain, which is regarded as a criterion of ductile fracture. For this purpose, API X65 pipes with gouge are simulated using elastic-plastic FE analyses with the proposed ductile failure criterion and the resulting burst pressures are compared with experimental data. Agreements are quite good, which gives confidence in the use of the proposed criteria to defect assessment fer gas pipelines. Then, further extensive finite element analyses are performed to obtain the burst pressure solution of pipes with gouge as a function of defect depth, length and pipeline geometry.

  • PDF

Pipe Wall-Thinning Inspection using Vibration Modes of Pipes with Circumferentially Varying Thickness (원주 방향 두께가 불균일한 배관의 진동 모드 특성을 이용한 배관 감육 검사 기법 연구)

  • Han, Soon-Woo;Seo, Jeong-Seok;Park, Jin-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.18-26
    • /
    • 2017
  • This work proposes an alternative pipe wall-thinning inspection method based on change of eigenfrequencies of shell vibration modes in wall-thinned pipes. It takes much time to detect wall-thinning of pipes using ultrasonic thickness gauge and only a limited number of pipes are under regular inspection. In a pipe with locally decreased thickness, stiffness varies along circumferential direction and natural frequencies of shell vibration modes of the pipe change or frequencies of same modes bifurcate into two different values. Therefore, one can monitor pipe wall-thinning by measuring change of natural frequencies or estimate wall-thinning shape qualitatively. The feasibility of the proposed method was studied by FE vibration analysis for wall-thinned pipes. Modal testing was also carried out for the pipes with artificial wall-thinned section to verify the working performance of the suggested technique.

Evaluation of structural integrity of the HP vaporizer and pipes of LNG fuel gas supply system (LNG 연료 선박용 FGSS의 고압 기화기와 출입구 배관에 대한 구조 건전성 평가)

  • Kim, Chang-Soo;Yoon, Joo-Hwan;Lee, Chang-Joon;Ha, Man-Young;Cho, Jong-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.780-785
    • /
    • 2016
  • Heavy oil used as ship propulsion has a serious issue regarding exhaust emission of global warming. Recently, among large-scale merchant ships are using LNG as green ships so called ech-ships. In this study, an vaporizer and pipes under cryogenic and high pressure load were considered to evaluate structural integrity according to codes. Structural analysis of the vaporizer and pipes was performed using the commercial code, ANSYS. Integrity evaluation of the vaporizer based on von Mises stress was performed in accordance with allowable stress specified in ASME Boiler & Pressure Vesssel Section VIII Division 2. To assess structural integrity of the pipes, stress components were combined and compared with ASME B31.3. The calculated stresses for all load cases are lower than allowable stresses, therefore the structural integrity of equipments are verified.

Development of Performance Test Procedure for the Excess Flow Valve for Buried Piping for the Domestic LPG Mass Supply System (국내 LPG 집단공급시설 환경에 적합한 매몰배관용 과류차단밸브 성능시험 절차 개발)

  • Jang, Chanyeong;Lee, Ugwiyeon;Lee, Jinhan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.16-27
    • /
    • 2018
  • Since 2014, the Korean government has begun distributing LPG pipelines and LPG tankers to mountainous or island areas where it is difficult to open urban gas supply chains. When installing LPG supply facilities at village level and county level, it supplied consumers with 10 times higher quasi-low pressure (25 kPa to 100 kPa) than conventional gas supply pressure, increasing the risk of gas accident. Due to the pressure that is 10 times higher than the conventional gas supply pressure, large amounts of gas are released at a faster rate when leaked. In order to secure safety of quasi-low-pressure gas pipes, excess flow valves for quasi-low-pressure gas pipes are not developed and are not supplied in Korea. Therefore, Korea Gas Safety Corporation is investigating the performance standards and products of the excess flow valves in order to localize the excess flow valves.

A study on the performance prediction of 4 cycle 4 cylinder S.I. engine considering the unsteady flow in the intake and exhaust pipes (흡배기 관내의 비정상 유동을 고려한 4사이클, 4기통 전기.점화 기관의 성능 예측에 관한 연구)

  • 박성서;김응서
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.72-81
    • /
    • 1991
  • In this study, the analytic investigation of the unsteady flow in the intake and exhaust pipes has been carried out using the method of characteristics in one direction to predict volumetric efficiency. Based on the calculated volumetric efficiency, three zone predictive analysis using Wiebe function was applied to predict the engine performance and the results were compared with experiment. Mixture in the cylinder is subdivided into three zones during combustion process in this analysis; adiabatic core zone, thermal boundary layer zone and unburned zone. In each zone, pressure, temperature and gas composition have been calculated. In conclusion, it is possible to take account of the intake and exhaust pipe tuning effect in predicting the engine performance, by the analytic solution of the unsteady flow in the pipes, and comparison of prediction with experimental results shows a good agreement on the pressure variation in the intake and exhaust pipes which has a direct influence on the volumetric efficiency and performance of the engine.

  • PDF

Development of droplet entrainment and deposition models for horizontal flow

  • Schimpf, Joshua Kim;Kim, Kyung Doo;Heo, Jaeseok;Kim, Byoung Jae
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.379-388
    • /
    • 2018
  • Models for the rate of atomization and deposition of droplets for stratified and annular flow in horizontal pipes are presented. The entrained fraction is the result of a balance between the rate of atomization of the liquid layer that is in contact with air and the rate of deposition of droplets. The rate of deposition is strongly affected by gravity in horizontal pipes. The gravitational settling of droplets is influenced by droplet size: heavier droplets deposit more rapidly. Model calculation and simulation results are compared with experimental data from various diameter pipes. Validation for the suggested models was performed by comparing the Safety and Performance Analysis Code for Nuclear Power Plants calculation results with the droplet experimental data obtained in various diameter horizontal pipes.

Characteristics of Structural Behavior of Unplasticized Polyvinyl Chloride (PVC-U) Pipe Buried Underground (지중매설 경질폴리염화비닐관의 구조적 거동)

  • Kim, Sun-Hee;Cheon, Jinuk;Kim, Eung-Ho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.16-23
    • /
    • 2015
  • The industrialization and urbanization forced to increase the density of pipelines such as water supply, sewers, and gas pipelines. The materials used for the existing pipe lines are mostly composed of concretes and steels, but it is true that the development for more durable and efficient materials has been continued performed to produce long lasting pipe lines. Recently, underground pipes serve in diverse applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. In this paper, we present the result of investigation pertaining to the structural behavior of unplasticized polyvinyl chloride (PVC-U) flexible pipes buried underground. In the investigation of structural behavior such as a ring deflection, pipe stiffness, 4-point bending test, experimental and analytical studies are conducted. In addition, pipe stiffness is determined by the parallel plate loading tests and the finite element analysis. The difference between test and analysis is about 8% although there are significant variations in the mechanical properties of the pipe material. In addition, it was found by the 4-point bending test there is no problem in the connection between the pipes by coupler.