• 제목/요약/키워드: gas measurement

검색결과 1,916건 처리시간 0.025초

A Computational Work of Critical Nozzle Flow for High-Pressure Hydrogen Gas Mass Flow Measurement (고압수소 유량계측용 임계노즐 유동의 수치해석적 연구)

  • Lee, Jun-Hee;Kim, Heuy-Dong;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.227-230
    • /
    • 2006
  • The method of mass flow rate measurement using a critical nozzle is well established in the flow satisfying ideal gas law. However, in the case of measuring high-pressure gas flow, the current method shows invalid discharge coefficient because the flow does not follow ideal gas law. Therefore an appropriate equation of state considering real gas effects should be applied into the method. The present computational study has been performed to give an understanding of the physics of a critical nozzle flow for high-pressure hydrogen gas and find a way for the exact mass flow prediction. The two-dimensional, axisymmetric, compressible Navier-Stokes equations are computed using a fully implicit finite volume method. The real gas effects are considered in the calculation of discharge coefficient as well as in the computation. The computational results are compared with the previous experimental data and predict well the measured mass flow rates. It has been found that the discharge coefficient for high-pressure hydrogen gas can be corrected properly adopting the real gas effects.

  • PDF

An On-Line Measurement of Ethanol Concentration by Membrane Gas Sensor (막가스센서에 의한 에탄올 농도의 온라인 측정)

  • 김형찬;박민선
    • KSBB Journal
    • /
    • 제10권2호
    • /
    • pp.126-130
    • /
    • 1995
  • A membrane gas sensor was developed for the measurement of ethanol concentration during acetic acid fermentation. The fermentation broth including ethanol was permeated through the silicone membrane by synthetic air as a carrier gas and was detected by a semiconductor gas sensor. The optimum conditions of membrane gas sensor were 20m1/min of flow rate and 0.5mm of membrane thickness. In acetic acid fermentation, an on-line measurement of ethanol concentration was conducted by the proposed membrane gas sensor and then the on-line sensor signal, was compared with the result of off-line analysis by gas chromatography. As a result, a correlated response over the range of $0∼70g/\ell$ was shown between membrane gas sensor and gas chromatography and this use of membrane gas sensor was experimentally ascertained for the monitoring and control of bioprocess like acetic acid fermentation.

  • PDF

Development of Gas Measurement System for the Harmful Gases at Livestock Barn (축산생육환경 유해가스 모니터링을 위한 무선가스측정시스템 개발)

  • Kim, Young Wung;Paik, Seung Hyun;Park, Hong Bae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • 제49권9호
    • /
    • pp.314-321
    • /
    • 2012
  • Harmful gases which are generated from various rout at growth environment of livestock ban have a direct and indirect bad influence to the livestock and farmers, and also step-up breeding density and long-term exposure to the sealed environment of winter can be fatal. In this paper, we propose a gas measurement system for monitoring gases of ammonia, hydrogen sulfide, volatile organic compounds, etc. which arise from the muck. The measurement system consist of both wireless gas sensor node and gas recognition software using a Fuzzy Min-Max neural network. To evaluate the performance of suggested system, gas measurement experiments are performed in laboratory environment by using the designed wireless gas sensor node. And we show the performance through classification test for the target gases by the designed gas recognition software.

Uncertainty evaluation in electrochemical noise resistance measurement (전기화학적 노이즈 저항 측정에서의 불확도 평가)

  • Kim, Jong Jip;Kang, Su Yeon
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Lee, Dae-Sung;Yang, In-Young;Jun, Yong-Min;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제26권11호
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field (현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교)

  • An, Seung-Hee;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

Temperature Measurement by Radiation Wavelength of High Temperature CO2 gas (고온 CO2 가스의 복사 파장을 이용한 부분별 온도 측정)

  • Maeng, Saeromg;Yoo, Miyeon;Kim, Saewon;Lee, Changyeop
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.315-316
    • /
    • 2014
  • Combustion gases emit various radiation signals by chemical reaction and excited molecules in combustion system. Since temperature measurement of combustion system is very difficult, non-contact temperature measuring methods are being researched. In this paper, we propose optical system of simple structure and implement technique for measuring temperature partially in furnace using radiation wavelength signals of high temperature $CO_2$ gas generated during combustion.

  • PDF

Development and Measurement Error Compensation of Odometer System for Intelligent PIG (인텔리전트 피그를 위한 주행거리계의 개발 및 측정오차 보상)

  • Kim D.K.;Park S.S,;Cho S.H.;Yoo H.R.;Park D.J.;Koo S.J.;Rho Y.W.;Kho Y.T
    • Journal of the Korean Institute of Gas
    • /
    • 제6권1호
    • /
    • pp.17-23
    • /
    • 2002
  • This paper introduces the spring-mounted odometer system which maintains the correct contact with the pipe wall and measures the distance along the pipe. The odometer wheel is designed to keep contact to the pipelines inner wall and to generate fifty rectangular pulses per one turn(159.5681mm) during pigging. The pipeline has the defects in various types such as buckles, winkles, cracks, dents, welding point and so on. Specially girth welding points which exist each 12m of the pipeline, much affects the operational environment of the odometer. The measurement error of the distance along the pipe is accumulated, for the measurement error of wheel's circumference and the pipeline inner environment. So, this paper proposes the method for the error compensation based on the analysis of the odometer's behavior around the girth welding point of pipe. The experimental results show that developed odometer system can be used for the intelligent pig with good performances.

  • PDF

Development of Gas Production Measurement System by Bubble Counting during Fermentation (기포계수식 발효가스 발생량 계측시스템의 개발)

  • Lee, Young-Jin;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • 제26권3호
    • /
    • pp.195-198
    • /
    • 1994
  • A bubble counter was designed and fabricated for the measurement of gas production rate on the basis of number of bubbles produced from yeast fermentor. The sensor was consisted of bubble forming device and electronic signal processing circuitry. The bubble forming device was built with bubble collector and liquid cell to form uniform size of bubble. Bubbles were counted by pulses formed by photo-interrupter circuitry having 8-bit binary latch counter. The gas production rate curves on the basis of bubble counted showed a good agreement to that of growth curves obtained by the optical measurement method. The sensor was succesfully applied to monitoring of the nutrient utilization test with glucose and galactose media.

  • PDF

Improvement of Soot Probe Efficiency for Automotive Emission Measurement (자동차 배기가스 측정을 위한 매연프로브 효율 개선에 관한 연구)

  • Chae, Il-Seok;Kim, Sang-Yu;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제18권8호
    • /
    • pp.74-81
    • /
    • 2019
  • Cars are inspected in the transport sector for their ability to achieve the greenhouse gas reduction targets. A vehicle (automobile) inspection broadly consists of regular and total checks, and both the safety level and the amount of exhaust gas are checked simultaneously during a vehicle inspection. This study deals with the efficiency of a soot probe to measure soot emissions from diesel vehicles. When the vehicle exhaust gas measurement is performed, there may be a difference between the exhaust gas temperature and the soot suction amount because of the different shape and angle of the exhaust port for each vehicle type. This may result in some incidents where the correct inspection nonconforming vehicle is not selected. Therefore, in this study, the shape of the probe was improved to increase the soot measurement efficiency under the condition of the exhaust pipe angle change.