• 제목/요약/키워드: gas generator

검색결과 757건 처리시간 0.023초

진공관 전원방식 30 W급 구리증기레이저 (A 30 W Copper Vapor Laser Using a Vacuum Tube Based Pulse Generator)

  • 진정태;차병헌;김철중;이흥호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.568-572
    • /
    • 2003
  • A longitudinal discharge heated copper vapor laser with internal diameter 28 mm and discharge length 1.3 m has been constructed and tested. At the discharging voltage 15.2 kV, pulse repetition rate 10 kHz, buffer gas pressure 40 mbar, and internal temperature of the laser plasma tube $1520^{\circ}C$, it delivers more than 30 W average laser outputs.

분사기 수에 따른 실물형 가스발생기 연소특성 (Effect of Injector Number on Combustion Characteristics of Full-scale Gas Generators)

  • 안규복;서성현;임병직;김종규;이광진;한영민;최환석
    • 항공우주기술
    • /
    • 제6권1호
    • /
    • pp.128-135
    • /
    • 2007
  • 분사기 헤드에 설치된 분사기 수를 바꾸어가며 실물형 가스발생기의 연소 특성에 대한 실험적 연구를 수행하였다. 가스발생기에 공급되는 총 추진제의 유량은 같으면서 분사기당 유량이 달라지는 실물형 가스발생기 3대가 사용되었다. 각 가스발생기에는 13개, 19개, 37개의 내부 혼합형 이중 스월 분사기가 배치되었다. 연소시험 결과, 13개, 19개 분사기를 장착한 가스발생기는 축방향 공진주파수에 해당하는 섭동이 발생하지 않았지만, 37개 분사기가 장착된 가스발생기의 경우 강도가 작긴 하지만 축방향 공진주파수에 해당하는 압력 섭동 현상이 나타나고 있다. 분사기 수가 증가할수록 연소실내의 온도 분포 편차는 점차 작아지지만, 분사기 LOx post의 손상은 증가하는 결과를 나타내었다.

  • PDF

배열회수 보일러 구조물의 피로수명 평가를 위한 유동해석 (The CFD Analysis for the Fatigue Life Evaluation of HRSG Structure)

  • 김진범;김철호
    • 에너지공학
    • /
    • 제29권3호
    • /
    • pp.7-17
    • /
    • 2020
  • 배열회수보일러는 가스터빈의 고온의 배기가스 에너지를 이용하여 증기를 발생시키는데 고속의 배기 가스에 의해 유체유발진동이 발생하여 다수의 구조물 파손이 발생한다. 구조물의 파손을 예측하기 위한 피로수명 평가는 유체유발 진동으로 발생하는 진동분석을 통해 PSD(Power Spectral Density)을 도출해야 하지만, 가스터빈의 배기가스 유동 형태가 매우 빠르고 복잡하여 발생되는 진동을 이론, 실험적으로 도출되는 것은 매우 어렵다. 하지만 LES(Large Eddy Simulation) 적용을 통해 구조물의 위치에 따라 진동 특성을 파악할 수 있는 방법을 정립하였고, 이러한 진동 특성을 구조 해석에 적용하면 구조물 피로수명 평가에 활용할 수 있다.

분사기 설계에 따른 실물형 가스발생기 연소특성 비교 (Effect of Injector Design on Combustion Characteristics of Full-scale Gas Generators)

  • 안규복;서성현;이광진;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.309-315
    • /
    • 2006
  • 분사기 설계에 따른 실물형 가스발생기의 연소 특성에 대한 연구를 수행하였다. 가스발생기에 공급되는 총 추진제의 유량은 같으면서도 분사기 설계에 따라 분사기당 유량이 달라지는 실물형 가스발생기 3대가 제작되었다. 각 가스발생기에는 13개, 19개, 37개의 내부 혼합형 이중 스월 분사기가 배치되었다. 연소시험 결과, 13개, 19개 분사기를 장착한 가스발생기는 축방향 공진주파수에 해당하는 섭동이 발생하지 않았지만, 37개 분사기가 장착된 가스발생기의 경우 강도가 작긴 하지만 축방향 공진주파수에 해당하는 연소불안정 현상이 나타나고 있다. 분사기 헤드에 배치된 분사기 수가 증가할수록 연소실내의 온도 분포는 작은 편차를 보이지만, LOx post의 손상은 증가하는 것을 알 수 있었다.

  • PDF

2압, 증기분사 복합발전 사이클에 대한 성능해석 (A dual Pressure, Steam Injection Combined cycle Power Plant Performance Analysis)

  • 김수용;손호재;박무룡;윤의수
    • 연구논문집
    • /
    • 통권27호
    • /
    • pp.75-86
    • /
    • 1997
  • Combined cycle power plant is a system where a gas turbine or steam turbine is used to produce shaft power to drive a generator for producing electrical power and the steam from the HRSG is expanded in a steam turbine for additional shaft power. Combined cycle plant is a one from of cogeneration. The temperature of the exhaust gases from a gas turbine ranges from $400^\circC$ to $600^\circC$, and can be used effectively in a heat recovery steam generator to produce steam. Combined cycle can be classed as a "topping(gas turbine)" and a "bottoming(steam turbine)" cycle. The first cycle, to which most of the heat is supplied, is called the topping cycle. The wasted heat it produces is then utilized in a second process which operates at a lower temperature level and is therefore referred to as a "bottoming cycle". The combination of gas/steam turbine power plant managed to be accepted widely because, first, each individual system has already proven themselves in power plants with a single cycle, therefore, the development costs are low. Secondly, the air as a working medium is relatively non-problematic and inexpensive and can be used in gas turbines at an elevated temperature level over $1000^\circC$. The steam process uses water, which is likewise inexpensive and widely available, but better suited for the medium and low temperature ranges. It, therefore, is quite reasonable to use the steam process for the bottoming cycle. Only recently gas turbines attained inlet temperature that make it possible to design a highly efficient combined cycle. In the present study, performance analysis of a dual pressure combined-cycle power plant is carried out to investigate the influence of topping cycle to combined cycle performance.

  • PDF

설계 인자에 따른 연료 과농 가스발생기의 연소 안정성 특성 연구 (A Parametric Study on Combustion Stability Characteristics of Fuel-rich Gas Generators)

  • 안규복;문일윤;서성현;한영민;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.171-176
    • /
    • 2006
  • 연료 과농 가스발생기에 대한 실험적 연구가 수행되었다. 연소 성능에 주요한 영향을 미치는 분사기 헤드에는 1.5의 리세스 수를 갖는 내부 혼합형 이중 스월 분사기 37개가 배치되었다. 본 논문에서는 연소실 길이, 직경, 그리고 교반링 등의 연소실 설계 변경에 따른 실물형 가스발생기의 연소 안정성 특성에 대하여 살펴보았다. 연소시험 결과 공진 주파수가 고주파 영역에서 생성됨에 따라 동압의 세기는 전반적으로 감소하였으나, 연소 불안정을 완전히 억제시키지는 못하는 것으로 나타났다.

  • PDF

파이로스타터용 점화기 개발 (Development of an Igniter for Pyrostarters)

  • 박호준;홍문근;권미라;이수용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.149-152
    • /
    • 2009
  • 파이로스타터는 일종의 가스발생기로써, 내부에 충전되는 저온 고체 추진제의 연소가스를 통해 시동에 필요한 에너지를 터빈에 공급한다. 파이로스타터의 연소관에 충전된 저온 고체추진제를 연소시키기 위한 초기 에너지를 공급해 주기 위해서는 파이로스타터 및 고체추진제의 특성과 형상에 맞는 점화기 설계가 필요하다. 이에 C.B.T 시험을 수행하여 초기 연소실 내부의 충분한 압력 증가를 확보할 수 있는 점화기의 주요 설계 인자를 결정하였다. 파이로스타터의 연계연소시험을 통해 신뢰성 있는 점화 특성을 확인하였고, 점화장약 충전량에 대한 간단한 해석을 수행하였다.

  • PDF

저탄소 고질소 산화제 적용 추진제 특성 연구 (The Study of Propellant Characteristic for Low Carbon & High Nitrogen Oxidizer)

  • 원종웅;최성한;박영철
    • 한국추진공학회지
    • /
    • 제21권2호
    • /
    • pp.26-31
    • /
    • 2017
  • 고체 추진제의 환경적 문제는 고체 로켓에서 중요한 이슈로 부각되고 있다. 예를 들어 고체추진제의 산화제인 ammonium perchlorate (AP)는 염산과 같은 독성 가스와 대기 오염을 발생시켜 환경적 문제를 야기한다. 산화제 중 N-guanylurea dinitramide (GuDN)는 높은 성능과 압력 지수를 가지고 있으며, 가스발생기 추진제에서 연소하는 동안 친환경적인 연기를 배출하는 성질을 가지고 있기 때문에 환경친화적으로 효과적인 후보 물질이다. 본 논문에서는 가스발생기 추진제로서 특성에 대하여 이론적 분석, 추진제 제조공정성, 추진제 경도 특성 및 연소특성에 대하여 연구하였다.

신재생발전 확대적용을 위한 ESS와 천연가스발전기의 경제성 평가 (Economic Evaluation of ESS and Natural Gas Generator for Expansion of New and Renewable Generation)

  • 주용진;신주곤;서동균;박세익
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.363-369
    • /
    • 2018
  • This paper considers the alternative way to mitigate cost for REC instead of Photovoltaic (PV) panels with Energy Storage System (ESS). This study starts from an economic analysis of a 1 megawatt PV system without ESS. Several assumptions have been applied in consideration of the current domestic situation. Based on this result, the economic efficiency of PV with ESS improved. However, the reliance on government subsidies was very high. The alternative way to cover the fluctuation power from renewable energy was reviewed with economical and technical way. In case the natural gas engine applied to PV, the IRR and Levelized Cost of Electricity (LCOE) can be improved without ESS. And if small amount of additional REC, the IRR can be improved up to investment level.