• Title/Summary/Keyword: gas facility

Search Result 762, Processing Time 0.025 seconds

GlSPD Analysis Using UHF Dual-Band Method (UHF 이중대역법을 이용한 GIS PD 분석)

  • Yi, Sang-Hwa;Choi, Jae-Gu;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

Analysis of Greenhouse Gas Emissions Associated with the Production of Wood Pellets (목재 펠릿 생산에 따른 온실 가스 배출량 분석)

  • Kim, Tae Hoon;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.21 no.3
    • /
    • pp.305-319
    • /
    • 2013
  • In this study, it is intended that utilize the LCA (Life Cycle Assessment) method, to evaluate the environmental impact of wood pellet manufacturing facility. As mentioned above, wood pellet manufacturing facility of 20 has produced wood pellets as a raw material sawdust and wood in our country. In this study, in order to feature manufacturing process of wood pellets that resemble almost necessary to analyze evenly size and characteristics of various equipment whether these reasonable, the characteristics of the equipment may be different, the production of 20 places I surveyed the facility one central timber distribution center one large scale most of the equipment.

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

Development of Algorithm for Vibration Analysis Automation of Rotating Equipments Based on ISO 20816 (ISO 20816 기반 회전기기 진동분석 자동화 알고리즘 개발)

  • JaeWoong Lee;Ugiyeon Lee;Jeongseok Oh
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.2
    • /
    • pp.93-104
    • /
    • 2024
  • Facility diagnosis is essential for the smooth operation and life extension of rotating equipment used in industrial sites. Compared to other diagnostic methods, vibration diagnosis can find most of the initial defects, such as unbalance, alignment failure, bearing defects and resonance, compared to other diagnostic methods. Therefore, vibration analysis is the most commonly used facility diagnosis method in industrial sites, and is usefully used as a predictive preservation (PdM) technology to manage the condition of the facility. However, since the vibration diagnosis method is performed based on experience based on the standard, it is carried out by experts. Therefore, it is intended to contribute to the reliability of the facility by establishing a system that anyone can easily judge defects by establishing a vibration diagnosis method performed based on experience as a knowledgeable code system. An algorithm was developed based on the ISO-20816 standard for vibration measurement, and the reliability was verified by comparing the results of vibration measurement at various demonstration sites such as petrochemical plant compressors, hydrogen charging stations, and industrial machinery with the results of analysis using a development system. The developed algorithm can contribute to predictive maintenance (PdM) technology that anyone can diagnose the condition of the rotating machine at industrial sites and identify defects early to replace parts at the exact time of replacement. Furthermore, it is expected that it will contribute to reducing maintenance costs and downtime due to the failure of rotating machines when applied to various industrial sites such as oil refining facilities, transportation, production facilities, and aviation facilities.

Gas Accident Analysis and Suggestion of Countermeasure at Thawing Season (해빙기 가스사고분석 및 사고예방 대책 제시)

  • Park Kyo-Shik;Kim Eun-Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.2 s.10
    • /
    • pp.46-51
    • /
    • 2000
  • It is required that fuel gas accidents should be managed carefully along with the increase of fuel gas consumption. Factors to cause accidents were investigated through a systematic analysis of gas accidents during recent 4 years, which could be applied to prepare countermeasures to reduce gas accidents. The thawing season is found to be weak to gas accidents, showing a slightly higher rate of accident occurring than average. During this term although the number of LPG accident is similar to that of yearly average, countermeasures are required for LPG facilities since the portion of accident is large; in detail, user's carelessness, defective facility, or instrument failure are major causes. The number of city gas accident facility is larger than that of yearly average; particularly, defective facilities, third-party work, and appliance failure are major causes. As a result, countermeasures have been suggested for the accident of large portion or above yearly average.

  • PDF

An Analysis of Safety Management Items for Low Pressure Hydrogen Facility below 0.1MPa in Domestic Hydrogen Town (국내 수소타운 내 0.1MPa 이하 저압 수소 사용시설의 안전관리 항목 분석)

  • Lee, Duk-Gwon;Heo, Doo-Hyun;Lee, Sun-Kyu;Lee, Jung-Woon;Lyu, Geun-Jun;Lee, Yeon-Jae;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.85-91
    • /
    • 2015
  • As the interest in hydrogen energy is being increased, it is a widely issue to develop a lot of hydrogen technologies in the field of production, storage, transportation, application and others. In the aftermath, there is a hydrogen town in Ul San, which is expected to expand application fields of hydrogen energy, as a demonstration project. The hydrogen town in Ul San can consist of high and low pressure part by the gas pressure. The high pressure part is managed by 'the high pressure gas safety control act'. And, low pressure part is managed by 'the guideline for the safety management of demonstration project of hydrogen town'. In this paper, to improve efficiency of safety management, the direction of safety management is reviewed by an analysis of low pressure hydrogen facility and safety management items. And then, some improvement directions are suggested. In the end, it is expected that the results of this study could help to activate construction of hydrogen town and improve efficiency of safety management as well.

Application of the Microbial Process for Hydrogen Sulfide Removal and Bio-Sulfur Production from Landfill Gas (미생물 공법에 의한 매립가스 황화수소 제거 및 바이오황 생산)

  • Khim, Young-Min;Song, Hyo-Soon;Ahn, Hyoseong;Chun, Seung-Kyu
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.68-76
    • /
    • 2020
  • Operational testing of the THIOPAQ® facility that removes H2S from landfill gas was performed for 746 days. The average H2S removal efficiency was 99.4%, and the input quantities of air, NaOH, and nutrients per sulfur load were 13.1 ㎥/ton, 1.5 ㎥/ton, and 28.7 L/ton, respectively. The purity of the bio-sulfur produced from the facility was 94.8%, with 3.3% impurities, except for moisture. X-ray photoelectron spectroscopy showed that the compositional contents of amino acids and free amino acids of the bio-sulfur surface were 5,308 and 728 mg/kg, respectively. The mean particle size was 3.41 ㎛, which was much smaller than that of chemical sulfur. Based on these results, a high H2S removal rate of more than 97% is feasible, and high value-added bio-sulfur, which is used as a fungicide because of its hydrophilic characteristics and small size, can be obtained at this facility.

A Study on the Collecting Method of Reliability Database for Gas Facilities (가스설비의 신뢰도데이터 수집방법에 관한 연구)

  • Rhie, Kwang-Won;Yoon, Ik-Keun;Han, Sang-Tae;Oh, Sin-Kyu;Kim, Tae-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2008
  • The safety assessment for facility industry is now being periodically performed. For the purpose of scientific safety management, QRA(Quantitative Risk Assessment) is also being performed, and reliability data of the facilities is essential to perform the assessment. Generally, the existing safety assessment is performed by using the values announced in other industry processes, which result in the drop of reliability. In order to solve this problem, there is an urgent need to establish reliability database for the facilities. The most appropriate method is to perform a direct reliability analysis towards the facilities undergoing safety assessment. In this study, in compliance with the assessment method and procedure of OREDA-2002 handbook, the facility reliability data are collected, which include the calendar time and operational time in terms of different facility items, the number of failures in terms of different failure mode, the mean, standard deviation, lower limit and upper limit of failure rate, and the failure rate. And the data process method for this special occasion is also proposed when the number of failure is 0.

Prediction of the Blast Wave Propagation Over a Kick Motor Test Facility (Kick Motor 시험장 충격파 전파 예측)

  • Ok, Ho-Nam;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.220-223
    • /
    • 2008
  • A test facility to measure the performance of a KM(Kick Motor) is constructed, and prediction of blast wave propagation over the facility is performed to check if the safety of test personnel in MCC(Main Control Center) can be guaranteed even for the most severe explosion. Assuming that the initial explosion energy is contained in a sphere under the pressure of 500, 1000, 1500 psi, respectively, the radius of the sphere is determined for each pressure to set the mass of contained explosion gas to 35 kg. The material properties of explosion gas are set to be the ones of KM propellant combustion gas under normal condition. To reduce the effort and time required for a complex three-dimensional modeling, the flowfield is approximated to axismmetry. Calculations are performed for all three initial pressure conditions, and the analysis of the result is given for 1500 psi which is expected to be the worst case. The maximum pressure is 3.5 psig while the minimum pressure is -1.2 psig on the outer wall of MCC, and the maximum pressure difference between the inner and outer walls of protection wall amounts to 3.0 psi.

  • PDF

Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles (석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가)

  • Lee, Gi-Hyuk;Kim, Moon-Won;Yu, Tae-U;Yook, Se-Jin
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.