• 제목/요약/키워드: gas discharge tube

검색결과 90건 처리시간 0.028초

이중 베리어 방전 반응기를 사용한 $NO_x$ 제거에 관한 연구 (A Study on the Double Dielectric Barrier Discharge for $NO_x$ reduction)

  • 김동욱;김응복;정영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2182-2185
    • /
    • 1999
  • In this experimental study we propose the double dielectric barrier discharge(DDBD) reactor to produce as high an electric field as possible. DDBD reactor is designed to remove $NO_x$ at atmospheric pressures from the moving pollution source such as diesel automobile DDBD reactor consisted of two cylinder glass tubes arranged so that the gas flow was directed between the two tubes. Inside of the inner tube was filled with small metal beads and outside of the inner tube was wounded with stainless wire to form the electrode. The outer tube was surrounded by an aluminum foil In this reactor there are three electrodes, i.e. metal bead(C), helical wire(I) and aluminum foil(0). By using DDBD reactor we will report some interesting results of treatment of the gas which is the dilute mixtures of NO in N2. And then we compared thee results with the results of cylinder-wire(CW) which is one of popularly used reactor in non-thermal plasma applications.

  • PDF

방전가열형 구리증기레이저의 개발 (Development of the Discharge Heated Copper Vapor Laser)

  • 임창환;차병헌;성낙진;이종민
    • 한국광학회지
    • /
    • 제1권1호
    • /
    • pp.28-32
    • /
    • 1990
  • 방전가열형 구리증기레이저를 제작하였으며 그 동작특성을 조사하였다. 레이저관으로는 내경 25mm, 길이 106cm 인 고순도(99.8%) 알루미나관을 이용하였다. 방전전극은 molybdenum 튜브로 제작하였으며 전극간의 거리는 108cm 이었다. Ne 가스압력 40mbar, 충전전압 10kV, 반복률 5KHz, 레이저관 내부온도 $1500^{\circ}C$일 때 평균출력 10W를 얻었다.

  • PDF

방전에 의한 프라즈마에서의 마이크로파 전파특성 (The Properties of Microwave Propagation in Discharging Plasma)

  • 양인응;노방현;김봉열
    • 대한전자공학회논문지
    • /
    • 제5권3호
    • /
    • pp.31-39
    • /
    • 1968
  • 외부자계가 가해진 냉프라즈마에서의 마이크로파 전파 특성을 측정하였다. 직류방전프라즈마는 두 전극판을 구형도파관에 삽입한것과, 또한 유리시설관을 구형도파관에 삽입한 것에서 이루어졌다. 마이크로파 전파방향, 방전관축, 외부자계는 각각 수직이고, 자속밀도, 방전유기, 기체압등이 증가할때 프라즈마를 전파하는 마이크로파의 감쇠 및 흡수는 증가함을 보았다.

  • PDF

Al2O3 유전체를 이용한 산소/공기 원료에 따른 오존발생기의 특성 (A Characteristic Analysis of Ozone Generator Using the Al2O3 Ceramic Dielectric According to Gas Type(O2/Air))

  • 박현미;송현직;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.76-81
    • /
    • 2014
  • The ozone generation is commonly made with silent discharge method using quartz glass dielectric. In this paper, using $Al_2O_3$ dielectric to instead of the traditional quartz glass dielectric to improve the system efficiency is presented. The dielectric was manufactured as tube shape (Internal diameter${\times}$ Outside diameter: $11{\times}15mm$) using 99% $Al_2O_3$ ceramic. The characteristics of dielectric discharge and ozone generation were studied of experiments with variation of discharge power, discharge electrode space and rate of flow for supplied gas ($O_2$/Air). As the experimental results, in the same discharge space, the ozone concentration continuously increased with input power increasing, and ozone yield increased until saturation happened. Also, the expended power increased with discharge space extended due to discharge power increased. In additional, the ozone concentration of oxygen ozone was higher than air that was observed when using oxygen ozone in proposed experiments.

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

양방향 펄스전원을 이용한 NO 가스의 방전처리 (Discharge Processes of NO Gas Using Bidirectional Pulsed Voltage)

  • 주홍진;박정호;심재학;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1682-1684
    • /
    • 2001
  • In removing the flue-gas using electrical discharge method, it is important to dissociate or ionize the atoms and molecules by the collisions with energetic electrons and it produces the radicals that are used to decompose the pollutants. For that purpose, a bidirectional pulsed voltage is used to produce lots of energetic electrons efficiently and increase the power efficiency. The simulation is performed with changing the pulsewidth under the fixed applied voltage. The particle-mesh model coupling the NGP(nearest-grid-point) to FEM(finite element method) is used to simulate the behavior of electrons and the spatio-temporal variation of the electric field for the streamer in discharge tube.

  • PDF

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.

Hollow Cathode Discharge에서 플라즈마 특성에 관한 연구 (Study on Characteristics of Plasma in Hollow Cathode Discharge)

  • 윤만영;신종순
    • 한국인쇄학회지
    • /
    • 제23권2호
    • /
    • pp.93-101
    • /
    • 2005
  • The measured plasma temperature of Ar hollow cathode discharge for several metal cathodes are about $620\;{\sim}\;780K$ at discharge current of $7\;{\sim}\;10mA$. The optogalvanic signals were measured using hollow cathode discharge tube with argon as buffer gas at change of discharge currents. A change of ionization rate due to electron collision causes an increase or decrease of the electric conductivity. This change in electric conductivity generates the optogalvanic signal. We conclude that optogalvanic signal has close relation with the lowest metastable atoms density at low current.

  • PDF

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권6호
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.

비디오흉강경을 이용한 자연기흉의 치료시 국소적 Fibrin Glue 도포 (Surgical Treatment of Spontaneous Pneumothorax by Thoracoscopic Wedge Resection with Fibrin Glue)

  • 신화균
    • Journal of Chest Surgery
    • /
    • 제33권10호
    • /
    • pp.812-816
    • /
    • 2000
  • Background ; To evaluate the efficacy of Fibrin glue to decrease recurrence in video-assisted thoracoscopic surgery(VATS) for a treatment of spontaneous penumothorax. Material and Method : All medical records of 17 patients who underwent a thoracoscopic wedge resections of bullae with stapling device with Fibrin glue in our institute between May 1998 and December 1999 were reviewed. variables analyzed include affected sites primary indication of VATS. duration from admission to discharge duration of postoperative stay duration of chest tube drainage recurrence and complication. There were 16 men and 1 woman. Result : There was no evidence of hemodynamic instability or arterial blood gas abnormalities encountered during the procedure. Mean age at the time of the VATS was 26.9 years (range 15 to 61 years) The mean duration from admission to discharge was 7.8 days and mean postoperative stay was 5.1days mean chest tube indwelling period was 4..0 days. There was no recurrence of pneumothorx. Conclusion : Thoracoscopic wedge resections with introduction of fibrin glue are safe and effective and requires only a short hospital stay. We believe that this thoracoscopic technique will further simplify the surgical treatment of pneumothorax.

  • PDF