• 제목/요약/키워드: gas cooling

검색결과 1,089건 처리시간 0.03초

헬륨가스 주입식 유리섬유 냉각장치의 냉각성능 해석 (COMPUTATIONAL ANALYSIS ON THE COOLING PERFORMANCE OF GLASS FIBER COOLING UNIT WITH HELIUM GAS INJECTION)

  • 오일석;김동주;우마로프 알리세르;곽호상;김경진
    • 한국전산유체공학회지
    • /
    • 제16권4호
    • /
    • pp.110-115
    • /
    • 2011
  • A modern optical fiber manufacturing process requires the sufficient cooling of glass fibers freshly drawn from the heated and softened silica preform in the furnace, since the inadequately cooled glass fibers are known to cause improper polymer resin coating on the fiber surface and to adversely affect the product quality of optical fibers. In order to greatly enhance the fiber cooling effectiveness at increasingly high fiber drawing speed, it is necessary to use a dedicated glass fiber cooling unit with helium gas injection between glass fiber drawing and coating processes. The present numerical study features a series of three-dimensional flow and heat transfer computations on the cooling gas and the fast moving glass fiber to analyze the cooling performance of glass fiber cooling unit, in which the helium is supplied through the discretely located rectangular injection holes. The air entrainment into the cooling unit at the fiber inlet is also included in the computational model and it is found to be critical in determining the helium purity in the cooling gas and the cooling effectiveness on glass fiber. The effects of fiber drawing speed and helium injection rate on the helium purity decrease by air entrainment and the glass fiber cooling are also investigated and discussed.

가스냉방 보급효과에 대한 연구 (Study on The Supplying effect of Gas Air Conditioning Systems)

  • 한정옥;채정민;최경식;홍성호
    • 한국가스학회지
    • /
    • 제15권3호
    • /
    • pp.19-25
    • /
    • 2011
  • 냉방용 에너지는 크게 전력과 가스로 대별할 수 있는데, 전기냉방 시스템은 하절기 최대전력을 상승시키는 요인이 되고 있다. 전기에너지는 수요 공급 특성상 저장이 불가능하기 때문에 예상되는 최대전력을 상회하는 공급능력을 보유해야 하며 매년 하절기의 사회문제로 대두되어 왔다. 한편 가스냉방의 경우 흡수식 시스템과 GHP 시스템이 있다. 그러나 가스냉방 보급용량은 전기 냉방에 비해 매우 적으며 소형시장은 대부분 전기냉방에 의존하고 있는 상황이다. 본 논문에서는 국내 냉방에너지 현황을 살펴보고 에너지원간의 부하분담 비중을 분석하여 냉방에너지의 합리적인 방향을 제시하고자 2024년까지 장기적인 가스냉방 보급 규모를 전망하였으며, 이를 바탕으로 가스냉방 보급효과를 분석하여 가스냉방의 확대 필요성을 뒷받침 하고자 하였다.

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

에너지원별 냉방기기 표본설계 (Sample design of cooling systems for each energy source)

  • 강용태;이덕주;김의경;전호철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.202-208
    • /
    • 2008
  • The objectives of this study are to collect the population of each cooling system for gas and electric driven systems, and propose sample design for five cooling systems; ice storage systems, system air-conditioning system, turbo system as electric driven cooling systems, and absorption system and Gas driven Heat Pump (GHP) system as gas driven cooling systems. The sample design are carried out based on types of business, capacity, installation region and year. This study proposes criterion of the sample design for cooling systems for each energy source.

  • PDF

발전용 가스터빈 1단 동익 열전달 해석 (The Heat Transfer Analysis of the First Stage Blade)

  • 홍용주;최범석;박병규;윤의수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.30-35
    • /
    • 2001
  • To get higher efficiency of gas turbine, The designer should have more higher turbine inlet temperature (TIT). Today, modem gas turbine having sophisticated cooling scheme has TIT above $1,700^{\circ}C$. In the korea, many gas turbine having TIT above $1,300^{\circ}C$ was imported and being operated, but the gas with high TIT above $1,300^{\circ}C$ in the turbine will give damage to liner of combustor, and blade of turbine and etc. So frequently maintenance for parts enduring high temperature was performed. In this study, the heat transfer analysis of cooling air in the internal cooling channel (network analysis) and temperature analysis of the blade (Finite Element Analysis) in the first stage rotor was conducted for development of the optimal cooling passage design procedure. The results of network analysis and FEM analysis of blade show that the high temperature spot are occured at the leading edge, trailing edge near tip, and platform. so to get more reliable performance of gas turbine, the more efficient cooling method should be applied at the leading edge and tip section. and the thermal barrier coating on the blade surface has important role in cooling blade.

  • PDF

가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰 (A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System)

  • 유원주;이승현
    • 대한안전경영과학회지
    • /
    • 제12권2호
    • /
    • pp.75-82
    • /
    • 2010
  • Gas turbines for power generating operate in a very high temperature condition and use natural gas for fuel. For this reason, many cases of damage happen at hot gas parts which are severely affected by high temperature gas and many cases of explosion occur by fuel gas. So a lot of efforts should be made to prevent hot gas parts damage and gas explosion accidents. Though there are many damage cases and explosion accidents, it is very difficult to find out the root causes of hot gas parts damage caused by gas explosion due to gas leakage in the heat exchanger for air cooling and gas heating. To prevent gas turbine from damage caused by gas explosion, removal of leakage gas from gas turbine is inevitably required before firing the gas turbine and installing alarm systems is also required for detecting gas leakage at stop valve to turbine while shut down.

가스터빈 내부 냉각계통 발화에 의한 고온부품 손상의 현상학적 고찰 (A Phenomenological Review on the Damage of Hot Gas Parts caused by Explosion of Gas Turbine Cooling System)

  • 유원주;이승현
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 춘계학술대회
    • /
    • pp.81-95
    • /
    • 2010
  • Gas turbines generating power operate in high temperature condition and use natural gas as fuel. For that reason, there are many cases where damage is done to the hot gas parts caused by the high temperature and many accidents occur like gas explosions, then various efforts are needed to maintain the hot gas parts and prevent accidents. It is difficult to find the root causes of damage to the hot gas parts from the gas explosion caused by gas leakage through rotor cooling air line from fuel gas heat exchanger during the shut down. To prevent gas turbine from damage, removal of gas leakage inside of gas turbine is required by purging the turbine before firing, improving the fuel gas heating system and installing alarm systems for detecting gas leakage from stop valve to turbine while the gas turbine has shut down.

  • PDF

자동차용 기관의 냉각수 온도조절 최적화에 관한 연구(I) (A Study on the Optimum Cooling Water Temperature Control of an Automotive Engine(I))

  • 박경석;신진식;이경우
    • 오토저널
    • /
    • 제14권2호
    • /
    • pp.34-43
    • /
    • 1992
  • The purpose of this study is to consider the performance and exhaust characteristics in the practical engine according to the cooling water temperature change of engine and to set up the optimum cooling condition and to obtain the optimum operating condition of thermostat in the cooling system. In order to accomplish the purpose of this study, authors have used the following procedure. 1. This study is to investigate the influence of the cooling water temperature on the engine performance and the exhaust gas, authors regulated the cooling water temperature by using the special closing circuit and measured the concentration of exhaust gas by using the exhaust gas measuring system in the exhaust pipe. 2. This study carried out the experiment by regulating the opening degree of throttle valve and engine speed in the dynamometer and by changing the cooling water temperature, at the same time kept air-fuel ratio constant and made the spark ignition time MBT(Minimum spark advance for Best Torque) 3. This study measured the cooling water temperature by using the K-type thermocouple centring around the easy over-heated parts and by installing a special closing circuit. Therefore, in this study, authors intend to examine the influence of the cooling water temperature on the engine performance, exhaust gas and present the basic materials needed in the engine design including the optimum operating time control system for the cooling water temperature.

  • PDF

SF6 가스를 충전한 변압기의 자연순환 냉각시스템의 성능시뮬레이션 (Performance Simulation of Natural Circulating Cooling System of SF6 Gas Charged Transformer)

  • 최영돈;허창수;김진봉
    • 설비공학논문집
    • /
    • 제6권1호
    • /
    • pp.54-65
    • /
    • 1994
  • Performance of naturally circulating cooling system of $SF_6$ gas charged transformer was simulated and the variations of gas flow rate, maximum coil temperature, gas temperature and cooling air temperature were investigated with respect to the height of radiator, interplates distance and heat generation rate at core. The results show that the height of radiator most significantly affects the performance of natural circulating cooling system of transformer.

  • PDF

국내외 가스냉방 지원제도 비교분석 (Analysis on the Domestic and Abroad Policies and Regulations for the Gas Cooling Systems)

  • 김용찬;조금남
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.201-207
    • /
    • 2009
  • In this study, the domestic and abroad policies and regulations on the gas cooling systems have been analyzed. First, the current policies were investigated in Korea and other countries to stimulate the distribution of the gas cooling systems. The advantage and disadvantage for each policy were evaluated. Finally, several policies were proposed for the effective distribution of the gas cooling systems.

  • PDF