Absorption Properties of $CO_2$ in Aqueous Solutions of Piperazine, Piperidine, Cyclohexylamine (Piperazine, Piperidine, Cyclohexylamine 수용액에 대한 이산화탄소의 흡수특성)

  • Song Ho-Jun;Lee Seoungmoon;Song Hocheol;Ahn Se-Woong;Park Jin-won
    • Journal of Energy Engineering
    • /
    • v.14 no.4 s.44
    • /
    • pp.219-225
    • /
    • 2005
  • for the removal of carbon dioxide in flue gas, which is the main cause of the global warming, chemical absorption methods were widely used for years. Alkanolamines such as MEA, AMP, MDEA are mainly used as an absorbent. In this study, cyclic amines - Piperazine, Piperidine and Cyclohelylamine are investigated to compare the chemical solubilities, absorption capacities and rate ot reaction. In conclusion, Piperazine is the most effective absorbent of $CO_2$ and ran be the excellent alternative to the former absorbents. Experiments were performed at 5, 10, 15 weight percent, 30, 40, $50^{\circ}C$, and the gas solubilities are determined by back-titration method, and using Gas Chromatography the absorption rate was compared.

Development of High-Durability Ceramic Hollow Fiber and Performance Evaluation of Contact Membrane Process according to Pressure Conditions (고내구성 세라믹 중공사 개발과 압력 조건에 따른 접촉막 공정의 특성 평가)

  • Lee, Seung Hwan;Jeong, Byeong Jun;Shin, Min Chang;Zhuang, Xuelong;Jung, Jiwon;Lee, Yeon Jun;Won, Dongyeon;Park, Jung Hoon
    • Membrane Journal
    • /
    • v.30 no.6
    • /
    • pp.443-449
    • /
    • 2020
  • In this study, CO2 separation experiment was performed on a CH4/CO2 mixed gas using a ceramic hollow fiber membrane contactor module (HFMC). In order to fabricate high-durability HFMC, a high-durability hollow fiber membrane was prepared and evaluated. HFMC was fabricated using the prepared hollow fiber membrane, and the experiment used a mixture of CH4/CO2 (30% CO2, CH4 balance) and monoethanolamine (MEA). During HFMC operation, the effect of gas and absorbent pressure on the CO2 removal efficiency was evaluated. The CO2 removal efficiency increased as the gas pressure increased, and the CO2 absorption flux also showed a tendency to increase with the liquid flow rate. In addition, when the CO2 absorption rate was less than 40%, LTS-1, a counter-current form where the absorbent enters from the bottom, has higher CO2 removal performance than LTS-2, a countercurrent form in which the absorbent enters from the top. and when the absorption rate was 40% or higher, LTS-2 had higher performance than LTS-1.

Carbon Capture and CO2/CH4 Separation Technique Using Porous Carbon Materials (다공성 탄소재료를 이용한 CO2 포집 및 CO2/CH4 분리 기술)

  • Cho, Se Ho;Bai, Byong Chol;Yu, Hye-Ryeon;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.343-347
    • /
    • 2011
  • Due to the strong dependence on fossil fuels within the history of human progress, it leads to disaster of the whole world like flood, shortage of water and extinction of the species. In order to curb carbon dioxide emissions, many technologies are being developed. Among them, porous carbon materials have important advantages over other absorbent, such as high surface area, thermal and chemical resistance, low cost, various pore distribution and low energy requirement for their regeneration. Carbon capture and storage (CCS) has attracted the significant research efforts for reducing green house gas emission using several absorbent and process. Moreover, the absorbent are used for the separation of bio mass gas that contains methane which is considered a promising fuel as new green energy resource. In this review, we summarized the recent studies and trend about the porous carbon materials for CCS as well as separation from the biogas.

Cycle Analysis of Diffusion Absorption Refrigerator (확산형 흡수식 냉장고의 사이클 해석)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.

Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator (확산형 흡수식 냉장고에서 작동매체 충진조건이 증발온도에 미치는 영향)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.828-834
    • /
    • 2003
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20 kg$_{f}$cm$^2$ of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator.r.

Catalytic effect of metal oxides on CO2 absorption in an aqueous potassium salt of lysine

  • Dharmalingam, Sivanesan;Park, Ki Tae;Lee, Ju-Yeol;Park, Il-Gun;Jeong, Soon Kwan
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.335-341
    • /
    • 2018
  • We report the catalytic effects of metal oxides on the $CO_2$ absorption rate in an aqueous potassium salt of ${\text\tiny{L}}-lysine-HCl$ using the vapor liquid equilibrium method. The best $CO_2$ absorption rate obtained through testing metal oxides in a highly concentrated potassium salt of amino acids (2.0 M) was identified using CuO. The recyclability of the metal oxides was tested over three cycles. The catalyst CuO was found to enhance the absorption rate of $CO_2$ by 61%. A possible mechanism was proposed based on NMR spectroscopy studies. Further, the effect of change in liquid absorbent viscosity on $CO_2$ absorption is discussed.

Degradation Characteristics of Carbon Dioxide Absorbents with Different Chemical Structures (상이한 화학적 구조를 가진 이산화탄소 흡수제의 열화특성)

  • Kim, Jun-Han;Lee, Ji-Hyun;Jang, Kyung-Ryong;Shim, Jae-Goo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.883-892
    • /
    • 2009
  • We evaluated the degradation properties of various alkanolamine absorbents (MEA, AMP, DEA, and MDEA) having different chemical structures for $CO_2$ capture. The degradation of $CO_2$ absorbent in general was known to be caused by oxygen which is in flue gas and by heat source, respectively. To analyze the effect of $CO_2$ and $O_2$ on degree of degradation, we conducted a variety of experiments at $30^{\circ}C$ and $60^{\circ}C$ (oxidative degradation) and $130^{\circ}C$ and $150^{\circ}C$ (thermal degradation), respectively. DEA showed the worst property for oxidative degradation in the presence of oxygen among the alkanolamine absorbents. In the case of thermal degradation, the degradation of absorbent was occurred for most of absorbents at $150^{\circ}C$. Among these absorbents, MEA and DEA gave the worst results. As a result, AMP which is a primary amine and having a steric hindrance showed the best result through the degradation test. But, the degradation of absorbent proceeded easily in the case of DEA which is a secondary amine and having 2 OH groups in terminal position. Consequently, we have evaluated the degree of degradation of various absorbents having different chemical structures to give the basic data for the development of alkanolamine absorbent.

Removal Efficiency of Some Odorants against Water as Sorptive Media: A Case Study on Trimethylamine and Reduced Sulfur Compounds (물을 흡수매체로 이용한 트리메틸아민과 환원황화합물의 제거효율 비교 연구)

  • Ahn, Ji-Won;Kim, Ki-Hyun;Ok, Joon-Seok;Kim, Yong-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.512-522
    • /
    • 2009
  • In this study, the removal efficiency of trimethylamine (TMA) and four reduced sulfur compounds (RSC) of $H_2S$, $CH_3SH$, DMS, and DMDS was investigated using deionized water as absorbent. To this end, two types of experiments were conducted which include: (1) by passing both RSC and TMA standard gases through water contained in an impinger system and (2) by passing TMA gases through a water spray system. In the former method, TMA standard gases were effectively removed (below detection limit) in all experiments. Likewise, minor fractions of some RSC ($CH_3SH$, DMS, and DMDS) were removed by water in line with theoretical expectations. In addition, the first type of our experiment was extended further to test some commercially available odor treatment products. The results of this test showed that removal efficiencies of RSC $(8.2\pm13.7\sim43.7\pm2.48%)$ were different significantly among 4 kinds of absorbent, while the removal of TMA was consistently good as water. In the second phase of experiment, removal efficiency of TMA was tested by passing its standard gas through a water spray system. The overall results of our study showed that the actual removal efficiency of odorants by water (as sorptive media) approached the values that can be predicted theoretically (by Henry's law).

Determination and Calculation of Physical Properties for Sodium Glycinate as a CO2 Absorbent (CO2 제거용 흡착제 Sodium Glycinate의 물성측정과 추산)

  • Park, So-Jin;Jang, Gyeong-Ryong;Park, In Hwan
    • Korean Chemical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.277-283
    • /
    • 2006
  • Aqueous solution of sodium glycinate was checked as a suitable $CO_2$ absorbent from the flu gas in the thermal power plant. For this purpose, solubility, vapor pressure, latent heat of vaporization and thermal conductivity were determined for pure and aqueous solution of sodium glycinate. The solubility of sodium glycinate in the solvent, 25 g of $H_2O$, was increased with increasing the temperature and their relation was represented as a first order equation of y = 0.3471x + 20.993. The vapor pressure for 10 wt% to 60 wt% of aqueous sodium glycinate solution were determined and the latent heat of vaporization of each aqueous solution was calculated from measured vapor pressure using Clausius-Clapeyron equation. Besides, thermal conductivity of sodium glycinate powder was also determined and it was $1.0933kcal/m{\cdot}hr{\cdot}^{\circ}C$.