• 제목/요약/키워드: gap opening

검색결과 143건 처리시간 0.021초

Fracture resistance and marginal fit of the zirconia crowns with varied occlusal thickness

  • Tekin, Yadel Hazir;Hayran, Yeliz
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.283-290
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the clinical applicability of monolithic zirconia (MZ) crowns of different thickness via determination of fracture resistance and marginal fit. MATERIALS AND METHODS. MZ crowns with 0.5, 0.8, 1.0, and 1.5 mm thickness and porcelain fused to metal (PFM) crowns were prepared, ten crowns in each group. Marginal gaps of the crowns were measured. All crowns were aged with thermal cycling (5 - 55℃/10000 cycle) and chewing simulator (50 N/1 Hz/lateral movement: 2 mm, mouth opening: 2 mm/240000 cycles). After aging, fracture resistance of crowns was determined. Statistical analysis was performed with one-way ANOVA and Tukey's HDS post hoc test. RESULTS. Fracture loads were higher in the PFM and 1 mm MZ crowns compared to 0.5 mm and 0.8 mm crowns. 1.5 mm MZ crowns were not broken even with the highest force applied (10 kN). All marginal gap values were below 86 ㎛ even in the PFM crowns, and PFM crowns had a higher marginal gap than the MZ crowns. CONCLUSION. The monolithic zirconia exhibited high fracture resistance and good marginal fit even with the 0.5 mm thickness, which might be used with reduced occlusal thickness and be beneficial in challengingly narrow interocclusal space.

Effects of Opioid Pure Agonists on the Excitibility of Frog Sciatic Nerve Fibers

  • Lee, Jong-Hwa;Frank, George-B.
    • Archives of Pharmacal Research
    • /
    • 제16권2호
    • /
    • pp.83-88
    • /
    • 1993
  • opioid pure agonists, morphine, meperidine and methadone, were used to investigate the effect on the opioid receptor of fron sciatic nerve fibers using sucrose gap apparatus. When applied extracellularly by perfusion, morphine, methadone and meperidine significantly depressed the amplitude of the action potential in frog sciatic nerve fibers as a dose-dependent $(10^{-10}\;M-10^{-2}\;M)$ manner. The depression with morphine or methadone was partially antagonized by the simultaueous treatment with a lower $(10^{-10}\;M-10^{-8}\;M)$ concentration of naloxone, but that of meperidine was not blocked. When the three opioid agonists were applied intracellularly by placing it in a compartment with a cut end of the sciatic nerve fibers, all of themn depressed the amplitude of the action potentials by similar potency, and these reductions significantly blocked by pretreatment of lower concentration $(10^{-10}\;M-10^{-8}M)$ of naloxone. These results support the previous findings by other workers that the stereospecific opioid receptors of this preparation are located on or near the intracellular opening of the sodium channels which are sensitive to naloxone.

  • PDF

Osteotomy and iliac bone graft for the treatment of malunion caused by failed mandibular fracture reduction

  • Hwang, Kun;Ma, Sung Hwan
    • 대한두개안면성형외과학회지
    • /
    • 제21권6호
    • /
    • pp.384-386
    • /
    • 2020
  • This report describes osteotomy and iliac bone graft for malunion caused by failed mandibular fracture reduction. A 27-year-old man was referred 3 months after a motor vehicle accident. At another hospital, two operations had been performed for symphyseal fracture using two resorbable plates. Malocclusion was noted, and panoramic radiography and computed tomography revealed a misaligned dental arch, with a 9.37-mm gap between the central and the lateral incisor of the left mandible. A wafer was made from the patient's dental model, and a maxillary arch bar was applied. Through a lower gingivolabial incision, osteotomy was performed between the malunited symphyseal fracture segments. Both segments were reduced to their original position using the wafer and fixed with titanium miniplates via intermaxillary fixation (IMF). The intersegmental gap was filled with cancellous bone from the iliac crest. The gingival defect was covered with a mucosal transposition flap from the gingivolabial sulcus. IMF and the wafer were maintained for 5 and 9 weeks, respectively. At postoperative week 13, the screws were removed from the mandible and satisfactory occlusion was noted. His mouth opening improved from 2.5 to 3 finger breadths (40 mm). This case demonstrates the need for sufficient IMF when using resorbable plates.

악관절 강직증의 치험례 (THE CASES REPORT OF ANKYLOSIS)

  • 현영옥;강창희;노양호;천영두;김신헌;이희원
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권1호
    • /
    • pp.95-102
    • /
    • 2001
  • Temporomandibular ankylosis is defined as a situation in which the condyle is fused to the fossa by bone or fibrous tissue. Conditons such as trauma, infection, or systemic disease may predispose to various types of ankylosis, bringing about different levels of limitation in mandibular movement. Most patients with temporomandibular ankylosis are associated with limitation of maximal mouth opening, deviation of the chin toward the affected side, impaired occlusion, chronic pain, compromised oral hygiene, severe facial asymmetry & impeded mandibular molar eruption occurring in childhood. Several techniques to release ankylosis have been described in the literature, showing variable and often unsatisfactory results. The most frequently used operations are gap arthroplasty, interpositional arthroplasty, and exicision and joint reconstruction with autogenous or alloplastic materials. We have managed the two patients of TMJ ankylosis. They had previously TMJ surgery and we treated with gap arthroplasty & active physial therapy. We have obtained favorable results and report these cases with literatures review.

  • PDF

MARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNS

  • Kim Yong-Sun;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.275-283
    • /
    • 2006
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite because of sample size, measurement number, measuring instruments, etc, and there have been few studies about the marginal fit of the Digident CAD/ CAM zirconia ceramic crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made by using the Digident CAD / CAM zirconia ceramic crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and Methods. The crowns were made from one extracted maxillary central incisor pre-pared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. The in vitro marginal discrepancies of the digident CAD / CAM zirconia ceramic crowns and control groups(metal ceramic crowns) were evaluated and compared. Twenty crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were $88{\pm}10{\mu}m$ for the control (metal-ceramic crowns), $92{\pm}4{\mu}m$ for Digident CAD / CAM zirconia ceramic crowns. 2. Marginal gap between Digident CAD / CAM zirconia ceramic crowns and metal ceramic crowns did not show significant difference (P>.05). 3. The Digident CAD/ CAM zirconia ceramic crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

개구장애 환자의 병인, 감별진단 및 치료방식에 대한 임상연구 (CLINICAL STUDY ON THE ETIOLOGY, DIFFERENTIAL DIAGNOSIS AND TREATMENT OF TRISMUS)

  • 강희제;황대석;김용덕;신상훈;김욱규;김종렬;정인교
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권6호
    • /
    • pp.544-558
    • /
    • 2006
  • Trismus is a common problem to most people experiencing at once in his or her life and to most dental practitioners experiencing frequently. It has a number of potential causes which are single factor or complex factors. Its treatment will depend on the cause. The purpose of this study was to discuss the causes of trismus condition and the various treatments available. This study was made by reviewing of collected data from 86 patients complained of trismus among patients who were diagnosed by TMD, tumor, infection including tetanus, soft tissue anomalies, bony fracture and ankylosis from Jan 2002 to Dec 2004 on department of oral and maxillofacial surgery at Pusan National University Hospital, South Korea. The clinical reviews regarding chief complaints, clinical characteristics, diagnostic examination, treatments and the results on the patients were given as follows. 1. The etiology of trismus commonly were derived from temporomandibular joint(TMJ) disorder, TMJ ankylosis, TMJ tumor, odontogenic maxillofacial infection, mandibular condylar fracture, tetanus. 2. The chief complaints of trismus patients were progressive mouth opening limitation, TMJ pain, malocclusion, facial asymmetry, retrognathic state. 3. Especially, for the differential diagnosis between the fibrous ankylosis and true bony ankylosis, computed tomogram (CT) was useful. Surgical gap arthroplasty on bony ankylosis patients was applied and the gain of mouth opening after operation was average 35.8 mm during 19 months. 4. The tetanus, rarely, also induced the trismus with the range of mouth opening less than 10 mm. The average serum level of tetanus anti-toxin was 0.02-0.04 IU/mL. The limitation of mouth opening was improved into average 38 mm on 4 weeks after injection of 10,000 units of tetanus immune globulin. 5. In the treatment of osteochondroma, TMD, odontogenic infection and fracture, and the others inducing trismus, to obtian the maximum result and decreased inadequate time and effort, it is important to finding the causes from the exact clinical examination and diagnosis.

캘러킨 유한요소법을 이용한 미케니컬 페이스 시일의 윤활성능해석 (Lubrication Analysis of Mechanical Seal using Galerkin Finite Element Method)

  • 최병렬;이안성;최동훈
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.197-202
    • /
    • 1999
  • A mechanical face seal is a tribe-element intended to control the leakage of working fluid at the interface of a rotating shaft and its housing. The leakage of working fluid decreases as the seal surfaces get closer each other. But a very small seal clearance results in a drastic reduction of seal life because of high wear and heat generation. Therefore, in the design of mechanical face seals the compromise between low leakage and acceptable life is important and presents a difficult design problem. And the gap geometry of seal clearance affects seal performance very much and becomes an important design variable. In this study the Reynolds equation for the sealing dam of mechanical face seals is numerically analyzed using the Galerkin Finite Element Method, which can be readily applied to various seal geometries. The film pressures of the sealing dam are analyzed, including the effects of the seal face coning and tilt. Then, opening forces, restoring moments, leakages, and dynamic coefficients are calculated.

  • PDF

Data Interpolation and Design Optimisation of Brushless DC Motor Using Generalized Regression Neural Network

  • Umadevi, N.;Balaji, M.;Kamaraj, V.;Padmanaban, L. Ananda
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.188-194
    • /
    • 2015
  • This paper proposes a generalized regression neural network (GRNN) based algorithm for data interpolation and design optimization of brushless dc (BLDC) motor. The procedure makes use of magnet length, stator slot opening and air gap length as design variables. Cogging torque and average torque are treated as performance indices. The optimal design necessitates mitigating the cogging torque and maximizing the average torque by varying design variables. The data set for interpolation and ensuing design optimisation using GRNN is obtained by modeling a standard BLDC motor using finite element analysis (FEA) tool MagNet 7.1.1. The performance indices of the standard motor obtained using FEA are validated with an experimental model and an analytical method. The optimal design is authenticated using particle swarm optimization (PSO) algorithm and the performance indices of the optimal design obtained using GRNN is validated using FEA. The results indicate the suitability of GRNN as an interpolation and design optimization tool for a BLDC motor.

천체 망원경의 자동화 : I. 컴퓨터 제어와 자동 관측을 위한 기본 설계 및 하드웨어의 제작

  • 강용우;이형목;윤갑수
    • 천문학논총
    • /
    • 제6권1호
    • /
    • pp.62-75
    • /
    • 1991
  • The small sized telescope can be best used if the control and observation can be made remotely and fully automatically by the aid of computers. We discuss the possible ways of automating the existing telescopes of various designs using personal computers. 'We have specifically designed the parts necessary to automate 16 inch Cassegrain Telescope at Pusan University Observatory. The degree of automation we have set for the present work is the interactive. remote observation including opening and shutting down of dome slit. The observational modes we have in mind are photoelectric photometry and CCD imaging. The basic components of the hardware are interface card for 16 or 32 bit IBM PC family of computers, relay switches for the control of telescope movements, stepping motor controller card for the control of observational equipments, and AID converter unit that accepts signal from sensors for the environment conditions such as temperature, wind speeds, precipitation, etc. We also have designed and built a photoelectric photometer that can be fully controlled by the command of a computer. Such observational equipment is also essential in order that the remote observation can be realized.

  • PDF

IPM type BLDC 전동기의 자속장벽 설치에 따른 코깅 토크 저감 (Reducing the Cogging toque of IPM type BLDC Motor according to the Flux barrier shape)

  • 양병렬;윤근영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.67-69
    • /
    • 2004
  • This paper describes an approach to design a interior permanent magnet motor(IPM motor) for the reduction of cogging torque. The magnitude of the torque ripple and cogging torque in a interior permanent magnet motor(IPM motor) are generally dependent on several major factors: the shape of stator tooth tip, slot opening width, air gap length, the shape of barrier preventing flux leakage of magnets, magnet configuration and magnetization distribution or magnet poles. In this paper, the IPM BLDC motor is designed considering a saturated leakag flux between the barriers on the rotor for increasing the efficiency and decreasing the magnitude of the cogging torque. Analytical model is developed for the IPM BLDC motor with a concentrated winding stator. The results verifies that the proposed design approach is very efficient and effective in reducing the cogging torque and the torque ripple of the IPM BLDC motor to be used in an electric vehicle.

  • PDF