• Title/Summary/Keyword: gap measurement

Search Result 701, Processing Time 0.037 seconds

Pairing symmetry analyzed by a peak shape of density of states in an Bi2Sr2CaCu2O8+x superconductor

  • Kim, Hyun-Tak;Kang, Kwang-Yong
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.30-34
    • /
    • 2003
  • For an inhomogeneous superconductor, we reveal a relation of an observed superconducting gap, $\Delta$$_{obs}$ and the intrinsic true gap, $\Delta$$_{i}$, $\Delta$$_{obs}$(equation omitted) where band filling, 0<$\rho$<$\leq$1. $\Delta$$_{obs}$ is the effect of measurement when 0<$\rho$<1. The true gap is observed only when $\rho$=1. Parring symmetry analyzed by a coherence-peak shape of density of states, observed in B $i_2$S $r_2$CaC $u_2$ $O_{8}$$\chi$ superconductors, is s- wave.X> $O_{8}$$\chi$ superconductors, is s- wave. wave.

  • PDF

Cell gap measurement method far single-polarizer reflective liquid crystal cells (분광기를 이용한 반사형 TN LCD의 셀갭 측정)

  • 이기동;박경호;이서헌;윤태훈;김재창
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.468-471
    • /
    • 2001
  • A novel method to measure the cell gap of a single-polarizer reflective twisted nematic liquid crystal (TN LC) cell by using a rotating polarizer technique is proposed. By rotating an LC cell, we can measure the cell gap of an LC cell as well as the wavelength dependence of retardation under the condition that the twist angle is known.

  • PDF

A Study on the Measurements of Discharge Parameters in Case of the Switching Impulse Breakdown of a Large Air Spacing (이격거리가 큰 전국의 공기절연파괴 현상시 발생하는 인자측정에 관한 연구)

  • 최영욱;조연옥
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.12
    • /
    • pp.1290-1295
    • /
    • 1991
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/x10S0-6Ts - 5cm/x10S0-6Ts, electric field intensity of 2kv/cm, predischarge current of 1.2-1.6A, the charges injected into the air gap of 11-40x10S0-6TC for 400-887kV impulse voltages.

  • PDF

Detecting Method for Broken Rotor Bar of Induction Motor by Measuring Air-gap Flux (공극자속 측정에 의한 유도전동기 회전자의 Broken Bar 검출기법)

  • Hwang, Don-Ha;Kang, Dong-Sik;Lee, Jin-Hee;Choi, Kyeong-Ho;Kim, Dong-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.475-480
    • /
    • 2006
  • In this paper, a new approach for detecting broken rotor bars in a squirrel-cage induction motor is proposed. The air-gap flux variation analysis was done using search coils inserted in stator slots when broken rotor bar occurs. An accurate modeling and analysis of air-gap flux variation in the induction motor are developed using finite-element (FE) software packages, and measurement of the flux are made using search coils. The simulation was done for the induction motor with 380 [V], 5 [HP], 4 Poles, 1,742 [rpm] ratings using the commercial FE analysis tool. The simulation and experiment results can be useful for detecting the broken rotor bar of an induction motor.

  • PDF

A Study of Hot Gas Velocity Measurement in GCB Using Small-Gap (Small-Gap을 이용한 가스차단기에서의 열가스 속도측정에 관한 연구)

  • Chong, J.K.;Kim, H.K.;Song, K.D.;Park, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1044-1046
    • /
    • 2005
  • [$SF_6$] 가스차단기를 개발하기 위해서는 차단기가 동작하는 동안에 차단기 내부에서의 유동 파라메터(압력, 밀도, 온도, 속도 등)의 값을 정확하게 분석하는 것이 매우 중요하며, 특히, 아크가 존재할 경우 열가스 이동속도에 대한 분석은 필수적이다. 본 연구에서는 small-gap 측정시스템을 이용하여 시험용차단기가 동작할 때 차단부에서 발생하는 열가스의 이동속도를 측정하기 위한 연구내용을 정리하였다.

  • PDF

N-type doping and band gap change of Calix adsorbed on Graphene

  • Park, Seon-Min;Yang, Se-Na;Kim, Gi-Jeong;Kim, Bong-Su;No, Gwang-Hyeon;Lee, Han-Gil
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.341-341
    • /
    • 2010
  • Electronic structure of Calix adsorbed on epitaxial graphene (EG) was investigated using high resolution photoemission spectroscopy (HRPES). Increasing the deposition of calix molecule, we found that EG becomes n-type doping using secondary edge measurement (work function change). As we observe bonding nature of O 1s peak, we found that single O 1s peak can be clearly distinguished in the spectra indicating equivalent adsorption state. Finally, we were able to control the band gap of EG using valence band spectra as we change the amount of calix molecule. In this study, we will propose the possibility of band gap modulation of EG using calix molecule.

  • PDF

Mobility-Spectrum Analysis of an Anisotropic Material System with a Single-Valley Indirect-Band-Gap Semiconductor Quantum-Well

  • Joung, Hodoug;Ahn, Il-Ho;Yang, Woochul;Kim, Deuk Young
    • Electronic Materials Letters
    • /
    • v.14 no.6
    • /
    • pp.774-783
    • /
    • 2018
  • Full maximum-entropy mobility-spectrum analysis (FMEMSA) is the best algorithm among mobility spectrum analyses by which we can obtain a set of partial-conductivities associated with mobility values (mobility spectrum) by analyzing magnetic-field-dependent conductivity-tensors. However, it is restricted to a direct band-gap semiconductor and should be modified for materials with other band structures. We developed the modified version of FMEMSA which is appropriate for a material with a single anisotropic valley, or an indirect-band-gap semiconductor quantum-well with a single non-degenerate conduction-band valley e.g., (110)-oriented AlAs quantum wells with a single anisotropic valley. To demonstrate the reliability of the modified version, we applied it to several sets of synthetic measurement datasets. The results demonstrated that, unlike existing FMEMSA, the modified version could produce accurate mobility spectra of materials with a single anisotropic valley.

Design of an Antireflection Coating for High-efficiency Superconducting Nanowire Single-photon Detectors

  • Choi, Jiman;Choi, Gahyun;Lee, Sun Kyung;Park, Kibog;Song, Woon;Lee, Dong-Hoon;Chong, Yonuk
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.375-383
    • /
    • 2021
  • We present a simulation method to design antireflection coating (ARCs) for fiber-coupled superconducting nanowire single-photon detectors. Using a finite-element method, the absorptance of the nanowire is calculated for a defined unit-cell structure consisting of a fiber, ARC layer, nanowire absorber, distributed Bragg reflector (DBR) mirror, and air gap. We develop a method to evaluate the uncertainty in absorptance due to the uncontrollable parameter of air-gap distance. The validity of the simulation method is tested by comparison to an experimental realization for a case of single-layer ARC, which results in good agreement. We show finally a double-layer ARC design optimized for a system detection efficiency of higher than 95%, with a reduced uncertainty due to the air-gap distance.

The dosimetric impact on treatment planning of the Dynamic MLC leaf gap (동적 다엽콜리메이터의 Leaf gap이 전산화 치료계획에 미치는 영향)

  • Kim, Chong Mi;Yun, In Ha;Hong, Dong Gi;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.233-238
    • /
    • 2014
  • Purpose : The Varian's Eclipse radiation treatment planning system is able to correct radiation treatment thought leaf gap which is limitation MLC movement for collision with both MLC. In this study, I'm try to analyze dosimetric effect about the leaf gap in treatment planning system. And then apply to clinical implement. Materials and Methods : The Elclipse version is 10.0. In general, the leaf gap set to 0.05~0.3 mm and must measurement each leaf gap. The leaf gap measured by each LINACs and photons. We applied to measured each leaf gap in IMRT and VMAT. Changing the leaf gap, we evaluated treatment plans by Dmax, CI, etc. Results : When the same plan was evaluated with changing the leaf gap, an increase of 2-5% over the value Dmax, CI increases mm to 0.0~0.50 mm leaf gap. Volumetric modulated and intensity modulated radiation therapy plans all showed the same trend was not found significant between each radiation treatment planning. Conclusion : Generally, the leaf gap setting has a unique measure of the Multileaf collimator. However, the aging of the Multileaf collimator, calibration, and can be changed, after inspection and repair of the lip gap should eventually because these values affect the treatment plan must be applied to the treatment after confirmation. In some cases, may be to maintain the initial setting value of the lip gap, which is undesirable because it can override the influence on the treatment plan.

Measurement of Oil Pressure Distribution between the Piston and Cylinder in Hydraulic Piston Pump (유압 피스톤 펌프의 피스톤과 실린더 사이에서의 압력측정)

  • 김영환;박태조
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.237-242
    • /
    • 2000
  • In this paper, an experiment was carried out to measure the hydrodynamic oil pressure distribution in the clearance gap between a piston and cylinder. The results showed that the pressure distributions are highly affected by the eccentricity of the piston. Therefore present experimental method can be used to enhance the performance of hydraulic piston pumps. Further experimental studies for various operating conditions and improvement in data acquisition methods are required to obtain more accurate results.

  • PDF