GAMMA-RAY BURST FORMATION ENVIRONMENT: COMPARISON OF REDSHIFT DISTRIBUTIONS OF GRB AFTERGLOWS (감마선 폭발체의 생성 환경: 에너지 영역별 잔유휘광의 거리 분포 비교)

  • Kim, Sung-Eun;Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.4
    • /
    • pp.377-384
    • /
    • 2005
  • Since gamma-ray bursts(GRBs) have been first known to science societites in 1973, many scientists are involved in their studies. Observations of GRB afterglows provide us with much information on the environment in which the observed GRBs are born. Study of GRB afterglows deals with longer timescale emissions in lower energy bands (e.g., months or even up to years) than prompt emissions in gamma-rays. Not all the bursts accompany afterglows in whole ranges of waveleogths. It has been suggested as a reason for that, for instance, that radio and/or X-ray afterglows are not recorded mainly due to lower sensitivity of detectors, and optical afterglows due to extinctions in intergalactic media or self-extinctions within a host galaxy itself. Based on the idea that these facts may also provide information on the GRE environment, we analyze statistical properties of GRB afterglows. We first select samples of the redshift-known GRBs according to the wavelength of afterglow they accompanied. We then compare their distributious as a function of redshift, using statistical methods. As a results, we find that the distribution of the GRBs with X-ray afterglows is consistent with that of the GRBs with optical afterglows. We, therefore, conclude that the lower detection rate of optical afterglows is not due to extinctions in intergalactic media.

Radiation Detection System for Prevention of Illicit Trafficking of Nuclear and Radioactive Materials

  • Kwak, Sung-Woo;Chang, Sung-Soon;Yoo, Ho-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.167-171
    • /
    • 2010
  • Fixed radiation portal monitors (RPMs) deployed at border, seaport, airport and key traffic checkpoints have played an important role in preventing the illicit trafficking and transport of nuclear and radioactive materials. However, the RPM is usually large and heavy and can't easily be moved to different locations. These reasons motivate us to develop a mobile radiation detection system. The objective of this paper is to report our experience on developing the mobile radiation detection system for search and detection of nuclear and radioactive materials during road transport. Field tests to characterize the developed detection system were performed at various speeds and distances between the radioactive isotope (RI) transporting car and the measurement car. Results of measurements and detection limits of our system are described in this paper. The mobile radiation detection system developed should contribute to defending public's health and safety and the environment against nuclear and radiological terrorism by detecting nuclear or radioactive material hidden illegally in a vehicle.

Development of a Foods Radioactivity Monitoring Sensor for Household and Evaluation of its Effectiveness (가정용 식품 방사능 모니터링 센서 개발 및 유용성 평가)

  • Park, Hye Min;Kim, Jeong Ho;Lee, Un Jang;Kim, Do Hyung;Min, Su Jeong;Joo, Koan Sik
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.427-431
    • /
    • 2017
  • In this study, a foods radioactivity monitoring sensor was developed as a part of basic research for household radioactivity monitoring, and its performance was evaluated using a calibration source. The prototype of the sensor was based on a CsI:Tl scintillator using a crystal light guide and Si photomultiplier. The light guide was introduced to improve gamma-ray detection efficiency. For quantitative evaluation, tests were conducted using $^{134}Cs$ liquid source. In the performance evaluation, It was confirmed that analysis of $^{134}Cs$: 100 Bq/L(kg) was possible. Thus, result of this study is expected to contribute to research in the development of the household foods radioactivity monitoring system.

Detection of irradiated food using photostimulated luminescence and thermoluminescence (물리적 방법(PSL, TL)을 이용한 선종별 조사처리 식품의 검지 특성)

  • Jung, Yoo-Kyung;Lee, Ji-Yeon;Kang, Tae-Sun;Jo, Cheon-Ho;Lee, Jae-Hwang;Choi, Jang-Duck;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.399-404
    • /
    • 2016
  • The applicability of photostimulated-luminescence (PSL) and thermoluminescence (TL) for the detection of 12 food materials (potato, onion, garlic, dried pumpkin, black mushroom, black soybean, Cheongkukjang powder, sea mustard, pepper powder, Ramyun soup, corn tea, and green tea powder) irradiated with an electron beam, gamma ray, and X ray at a range of 0.15 to 10 kGy was investigated. For PSL, negative results (less than 700 photon counts (PCs)) were observed from non-irradiated foods while the irradiated foods showed intermediate (879 to 2,414 PCs) and/or positive (19,951 to 65,919,035 PCs) values. In all irradiated samples, the maximum peak of the TL glow curve was observed between 150 and $250^{\circ}C$. Our findings demonstrate the successful application of PSL and TL to determine whether food items were irradiated or not. However, there were no significant differences among the radiation sources.

Antimicrobial Effects of Retort and Gamma Irradiation on Bacterial Populations in Spicy Chicken Sauce (레토르트 및 감마선 조사에 의한 화닭 덮밥 소스의 미생물 제어 효과 비교)

  • Kim, Young-Sik;Kim, Hyun-Joo;Yoon, Yo-Han;Shin, Myung-Gon;Kim, Cheon-Jei;Shin, Mee-Hye;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.30 no.1
    • /
    • pp.141-147
    • /
    • 2010
  • This study evaluated the antimicrobial effects of retort process and gamma irradiation on reduction of total bacterial populations in spicy chicken sauce, which is served on top of the steamed rice. Commercial spicy chicken sauce was treated with retort and gamma ray at 0, 1, 3, 5, and 10 kGy. Total aerobic bacterial populations were then enumerated on plate count agar and isolated bacteria from the test samples were identified using PCR analysis. Moreover, gamma ray sensitivity of identified bacteria was evaluated by $D_{10}$ values, and genotoxicity of gamma-irradiated samples was examined. Gamma irradiation at 3 kGy reduced total aerobic bacterial cell counts in spicy chicken sauce below detection limit, but total aerobic bacterial cell counts in test samples treated with retort were 2.1 log CFU/g. Identified bacteria from the samples were Bacillus subtilis, B. amyloiquefaciense, and B. pumils, and the $D_{10}$ values for B. subtilis and B. cereus were 0.39 ($R^2\;=\;0.921$) and 0.28 log CFU/g ($R^2\;=\;0.904$), respectively. The SOS chromotest showed that the gamma-irradiated spicy chicken sauce did not cause mutagenicity. These results indicate that gamma irradiation of spicy chicken sauce could be useful in ensuring microbial safety.

Development of Anticosmic Shielded Ultra Low Background Gamma Spectrometer for Precise Measurement of Environmental Radioactivity

  • Byun, Jong-In;Park, Yun-Ho;Kwak, Seung-Im;Hwang, Han-Yull;Chung, Kun-Ho;Park, Gun-Sik;Park, Doo-Won;Lee, Chnag-Woo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • We developed an ultra low background gamma ray spectrometer particularly suitable for experiment which require lower detection limit. The background of a germanium spectrometer is suppressed by applying active and passive shielding technique at the same time. The active shielding devices consist of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shielding is made of 150 mm thick walls of very low activity lead,20 mm with activity of <10 Bq/kg and 130 mm with activity of <50 Bq/kg. The observed background count rates are 1.2 $s^{-1}$ and 0.36 $s^{-1}$ without and with the active shielding, respectively, overall the energy regions from 30 keV to 3 MeV The cosmic ray induced background is suppressed by a rate of 0.8 $s^{-1}$ at the present work. The detection efficiency curve necessary to obtain the radioactivity of environmental samples has been precisely determined on the energy regions from 80 to 2000 keV with a 10$^3$ ml marinelli beaker sample, consisting of the calibrated radionuclides $^{109}$ Cd, $^{57}$ CO, $^{139}$ Ce, $^{203}$ Hg, $^{113}$ Sn, $^{85}$Sr, $^{137}$ Cs, $^{60}$ Co and $^{88}$ Y. Virtues Of the method are demonstrated by measuring the activity of $^{137}$ Cs contained in the powdered milk.

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber (국내외 상용 단일모드 광섬유의 감마선 영향 분석 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.564-567
    • /
    • 2012
  • Optical fibers are going to be used for telecommunication, image fibers, sensors under irradiation in nuclear power plants and various irradiation facilities. Especially, Temperature detection sensors using Raman light scattering, temperature or strain sensors using fiber gratings, magnet-optical sensors using photo-magnetic effect, are already commercialized. However, When fibers are exposed to ionizing radiation, color centers are formed in fibers which reduces their light transmission, and it is limited in applying under radiation environments. In this study, $Co^{60}$ gamma-ray induced optical attenuation on Ge-doped single mode(SM) fiber has been measured. Gamma-ray is irradiated for 4hours at the dose rate of 0.5kGy/hr, 2kGy/hr, 8kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur precisely. Furthermore, dose rate effect that the higher dose rate in the same total dose, the more increase loss of optical fiber and annealing effect that the higher the loss after irradiation, the more increase the recovery rate of the loss are observed in the fiber. This results plan to make use of bases in the study of the radiation-hardened optical fiber.

  • PDF

The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 반도체 검출기 설계에 관한 연구)

  • Kim, Kyo-Tae;Kim, Joo-Hee;Han, Moo-Jae;Heo, Ye-Ji;Ahn, Ki-Jung;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.171-175
    • /
    • 2017
  • In the non-destructive inspection field, we invest a lot of time and resources in developing the radiation source system to ensure the safety of the workers. However, the probability of accidents is still high. In order to prevent potential radiation accidents in advance, it is necessary to directly verify the position of the radiation source, but the research is still insufficient. In this study, we developed a monitoring system that can detect the position of the radiation source in the source guide tube in the gamma-ray irradiator. The characteristics of the radiation detector are estimated by monte carlo simulation. As a result, the radiation detector for Ir-192 gamma-ray energy was analyzed to have secondary electron equilibrium at $150{\mu}m$ regardless of the semiconductor material. Also, it is expected that the gamma ray response characteristic is the best in $HgI_2$. These results are expected to be used as a basis for determining the optimal thickness of the radiation detector located in the detection part of the future monitoring system. In addition, when developing a monitoring system based on this, radiation workers can easily recognize the danger and secure safety, as well as prevent and preemptively respond to potential radiation accidents.

Development of Signal Processing Circuit for Side-absorber of Dual-mode Compton Camera (이중 모드 컴프턴 카메라의 측면 흡수부 제작을 위한 신호처리회로 개발)

  • Seo, Hee;Park, Jin-Hyung;Park, Jong-Hoon;Kim, Young-Su;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • In the present study, a gamma-ray detector and associated signal processing circuit was developed for a side-absorber of a dual-mode Compton camera. The gamma-ray detector was made by optically coupling a CsI(Tl) scintillation crystal to a silicon photodiode. The developed signal processing circuit consists of two parts, i.e., the slow part for energy measurement and the fast part for timing measurement. In the fast part, there are three components: (1) fast shaper, (2) leading-edge discriminator, and (3) TTL-to-NIM logic converter. AC coupling configuration between the detector and front-end electronics (FEE) was used. Because the noise properties of FEE can significantly affect the overall performance of the detection system, some design criteria were presented. The performance of the developed system was evaluated in terms of energy and timing resolutions. The evaluated energy resolution was 12.0% and 15.6% FWHM for 662 and 511 keV peaks, respectively. The evaluated timing resolution was 59.0 ns. In the conclusion, the methods to improve the performance were discussed because the developed gamma-ray detection system showed the performance that could be applicable but not satisfactory in Compton camera application.

Comparison of Photostimulated Luminescence, Thermoluminescence, and Electron Spin Resonance Spectroscopic Analyses on Dried-spices Irradiated by Gamma Ray and Electron Beam (감마선 및 전자선 조사 처리 건조향신료에 대한 광자극발광, 열발광 및 전자스핀공명의 분광학적 분석 비교)

  • Jeong, Jin-Hwa;Ahn, Jae-Jun;Baek, Ji-Yeong;Kim, Hyo-Young;Kwon, Joong-Ho;Jin, Chang-Hyun;Jeong, Il-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.256-261
    • /
    • 2014
  • This study was conducted to determine the effect of gamma-ray and electron-beam irradiation on dried spices (black pepper, red pepper, parsley, and basil) using the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods. The spices were irradiated at 0, 1, 5, and 10 kGy. All non-irradiated spices had photon counts (PCs) less than 700 PCs. The PCs of three irradiated spices (red pepper, parsley, and basil) were clearly distinguishable from those of non-irradiated ones, exhibiting PSL signals higher than 5000 PCs. However, negative PSL counts (<700 PCs) were obtained for most irradiated black pepper, except those irradiated with 5 kGy gamma rays and 10 kGy electron-beams. TL glow curves of the irradiated spices showed a higher peak at $150-250^{\circ}C$. TL ratios were found to be less than 0.1 for non-irradiated spices and higher than 0.1 for irradiated ones. No ESR signal was observed for any irradiated spice except red pepper, which displayed cellulose-based ESR spectra. Therefore, the results suggest that the PSL, TL, and ESR methods are effective detection techniques for dried spices irradiated with electron beams as well as gamma rays.