• Title/Summary/Keyword: gamma tool

Search Result 171, Processing Time 0.025 seconds

Development of Program for Renal Function Study with Quantification Analysis of Nuclear Medicine Image (핵의학 영상의 정량적 분석을 통한 신장기능 평가 프로그램 개발)

  • Song, Ju-Young;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shinn, Kyung-Sub;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.89-99
    • /
    • 2001
  • Purpose: In this study, we developed a new software tool for the analysis of renal scintigraphy which can be modified more easily by a user who needs to study new clinical applications, and the appropriateness of the results from our program was studied. Materials and Methods: The analysis tool was programmed with IDL5.2 and designed for use on a personal computer running Windows. For testing the developed tool and studying the appropriateness of the calculated glomerular filtration rate (GFR), $^{99m}Tc$-DTPA was administered to 10 adults in normal condition. In order to study the appropriateness of the calculated mean transit time (MTT), $^{99m}Tc-DTPA\;and\;^{99m}Tc-MAG3$ were administered to 11 adults in normal condition and 22 kidneys were analyzed. All the images were acquired with ORBITOR. the Siemens gamma camera. Results: With the developed tool, we could show dynamic renal images and time activity curve (TAC) in each ROI and calculate clinical parameters of renal function. The results calculated by the developed tool were not different statistically from the results obtained by the Siemens application program (Tmax: p=0.68, Relative Renal Function: p:1.0, GFR: p=0.25) and the developed program proved reasonable. The MTT calculation tool proved to be reasonable by the evaluation of the influence of hydration status on MTT. Conclusion: We have obtained reasonable clinical parameters for the evaluation of renal function with the software tool developed in this study. The developed tool could prove more practical than conventional, commercial programs.

  • PDF

Comparison of a whole blood Interferon-γ assay and A tuberculin skin test for detecting latent tuberculosis infection in children (소아 잠복 결핵 감염 진단에 있어서 투베르쿨린 피부반응 검사와 결핵 특이항원 자극 Interferon-γ 분비능 측정의 비교)

  • Chun, Jin-Kyong;Kim, Chang Ki;Kim, Hyun Sook;Jung, Ghee Young;Linton, John A.;Kim, Ki Hwan;Lee, Taek Jin;Jeon, Ji Hyun;Kim, Dong Soo
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.971-976
    • /
    • 2008
  • Purpose : Surveillance for detecting and managing latent tuberculosis infection (LTBI) is a key component of tuberculosis control. The classic surveillance tool, the tuberculin skin test (TST), may have some limitations when used in the Bacillus Calmette-$Gu{\acute{e}}rin$ (BCG)-vaccinated population. The object was to perform a blood test $QuantiFERON^{(R)}$-TB Gold In Tube (QFT-G IT) based on the detection of interferon-$\gamma$ ($IFN-{\gamma}$) released by T cells in response to Mycobacterium tuberculosis-specific antigens, and to compare the efficacy of this new diagnostic tool for LTBI with that of TST. Methods : For six months, between October 1, 2006 and April 30, 2007, data were collected from 111 patients under 15 years of age at Severance Children's Hospital. TST and QFT-G IT tests were performed with children with or without contact histories of tuberculosis. In addition to these tests, we examined comparative data from 29 adults who had tuberculosis, to detect false negative rates in the QFT-G IT method. Results : Thirty-three children had household contact histories. In this group, 15% and 42% of cases were found to be positive using the QFT-G IT assay and TST, respectively. Agreement was low between these two tests (${\kappa}=0.39$). In the adult active tuberculosis group, the QFT-G IT false negative rate defined as a positive culture and a negative QFT-G IT result was 12.5%. Conclusion : In diagnosing LTBI in children, the usefulness of a whole-blood $IFN-{\gamma}$ assay employing TB-specific antigens will be revealed only by examining additional longitudinal clinical data; this study serves as a starting point in that process.

A Study on Dose Distribution Programs in Gamma Knife Stereotactic Radiosurgery (감마나이프 방사선 수술 치료계획에서 선량분포 계산 프로그램에 관한 연구)

  • 고영은;이동준;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.175-184
    • /
    • 1998
  • The dose distribution evaluation program for the stereotactic radiosurgery treatment planning system using a gamma knife has been built in order to work on PC. And this custom-made dose distribution is compared with that of commercial treatment planning program. 201 source position of a radiation unit were determined manually using a gamma knife collimator draft and geometrical coordinates. Dose evaluation algorithm was modified for our purpose from the original KULA, a commercial treatment planning program. With the composed program, dose distribution at the center of a spherical phantom, 80 mm in diameter, was evaluated into axial, coronal and sagittal image per each collimator. Along with this evaluated data, the dose distribution at a arbitrary point of inside the phantom was compared with those from KULA. Radiochromic film was set up at the center of the phantom and was irradiated by gamma knife, for the verification of dose distribution. In result, the deviation of the dose distribution from that of KULA is less than ${\pm}$3%, which is equivalent to ${\pm}$0.3 mm in 50% isodose distribution for all examined coordinates and film verification. The custom-made program, GPl is proven to be a good tool for the stereotactic radiosurgery treatment planning program.

  • PDF

A Study on FPGA Design for Rotating LED Display Available Video Output (동영상 표출이 가능한 회전 LED 전광판을 위한 FPGA 설계에 관한 연구)

  • Lim, Young-Sik;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.168-175
    • /
    • 2015
  • In this paper, we propose FPGA design technique for rotating LED display device which is capable of displaying videos with the use of the afterimage effect. The proposed technique is made up of image data correction process based on inverse gamma correction and error diffusion, block interleaving process, and data serial output process. The data correction process based on inverse gamma correction and error diffusion is an image data correction step in which image data received are corrected by inverse gamma correction process to convert the data into linear brightness characteristics, and by error diffusion process to reduce the brightness reduction phenomenon in low-gray-level which is caused by inverse gamma correction. In the block interleaving process, the data of the frames entered transversely are first saved in accordance with entrance order, and then only the longitudinal image data are read. The data serial output process is applied to convert the parallel data in a rotating location into serial data and send them to LED Driver IC, in order to send data which will be displayed on high-speedy rotating LED Bar. To evaluate the accuracy of the proposed FPGA design technique, this paper used XC6SLX45-FG484, a Spartan 6 family of Xilinx, as FPGA, and ISE 14.5 as a design tool. According to the evaluation analysis, it was found that goal values were consistent with simulation values in terms of accurate operation of inverse gamma and error diffusion correction, block interleaving operation, and serialized operation of image data.

Springback Reduction of Multi-step Cylindrical Cup in Spinning Process. (스피닝공정에 있어서 스프링백 억제방안)

  • Park, Joong-Eon;Lee, Woo-Young;Choi, Seogou;Kim, Seung-Soo;Na, Kyoung-Hoan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.186-191
    • /
    • 2001
  • Spinning process is a chipless metal forming method for axi-symmetric parts, which is more economical, efficient and versatile method for producing parts than the other sheet metal forming process such as stamping or deep drawing. In this study, a fundamental experiment was conducted to improve productivity with process parameters such as tool path, angle of roller holder($\alpha$), feed rate($\gamma$) and corner radius of forming roller(Rr). These factors were selected as variables in the experiment because they were most likely expected to hale an effect on spring back. The empirical results were analyzed to know how much spring back was affected by these factors. And also thickness and diameter distribution of a multistage cup obtained by spinning process were observed and compared with those of a commercial product produced by conventional deep drawing.

  • PDF

Carbide Behavior in STD11 Tool Steel during Heat Treatment (STD11 공구강의 열처리 온도에 따른 탄화물 거동)

  • Hong, Ki-Jung;Song, Jin-Hwa;Chung, In-Sang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.5
    • /
    • pp.262-270
    • /
    • 2011
  • Carbide precipitation and dissolution behavior at various temperatures during heat treatment has been studied in STD11 cold working die steel through confocal scanning laser microscopy; dilatometry; and X-ray diffraction analysis. The equilibrium phase diagram and phase fractions with temperature were calculated using a FactSage program. Confocal laser microscopic observation revealed that ${\alpha}$ to ${\gamma}$ transformation temperature is near $800^{\circ}C$; M7C3 carbides melt at $1245^{\circ}C$; and the melting temperature of STD11 is near $1370^{\circ}C$. XRD results indicated that the M23C6 carbides dissolve in the matrix if austenitized at over $1030^{\circ}C$; while the M7C3 carbides remain up to $1200^{\circ}C$ although their amount decreases. The calculated equilibrium phase diagram showed good agreement with experimental results on carbide dissolution and phase transformation temperatures.

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

Analyses of the indispensible Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans (감마나이프 방사선수술 치료계획의 평가에 필수불가결한 지표들의 분석)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.303-312
    • /
    • 2017
  • The central goal of Gamma Knife radiosurgery(GKRS) is to maximize the conformity of the prescription isodose surface, and to minimize the radiation effect of the normal tissue surrounding the target volume. There are the various kinds of indices related with the quality of treatment plans such as conformity index, coverage, selectivity, beam-on time, gradient index(GI), and conformity/gradient index(CGI). As the best treatment plan evaluation tool, we must check by all means conformity index, GI, and CGI among them. Specially, GI and CGI related with complication of healthy normal tissue is more indispensible than conformity index. Then author calculated and statistically analysed CGI, the newly defined conformity/gradient index as well as GI being applied widely using the treatment planning system Leksell GammaPlan(LGP) and the verification method Variable Ellipsoid Modeling Technique(VEMT). In the study 10 patients with intracranial lesion treated by GKRS were included. Author computed the indices from LGP and VEMT requiring only four parameters: the prescribed isodose volume, the volume with dose > 30%, the target volume, and the volume of half the prescription isodose. All data were analyzed by paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in GI at 10 cases was observed between LGP and VEMT. Differences in GI ranged from -0.14 to 0.01. The newly defined gradient index calculated by two methods LGP and VEMT was not statistically significant either. Author did not find out the statistical difference for the prescribed isodose volume between LGP and VEMT. CGI as the evaluation index for determining the best treatment plan is not significant statistically also. Differences in CGI ranged from -4 to 3. Similarly newly defined Conformity/Gradient index for GKRS was also estimated as the metric for the evaluation of the treatment plans through statistical analysis. Statistical analyses demonstrated that VEMT was in excellent agreement with LGP when considering GI, new gradient index, CGI, and new CGI for evaluating the best plans of GKRS. Due to the application of the fast and easy evaluation tool through LGP and VEMT author hopes CGI and newly defined CGI as well as gradient indices will be widely used.

Development of Quality Assurance Software for $PRESAGE^{REU}$ Gel Dosimetry ($PRESAGE^{REU}$ 겔 선량계의 분석 및 정도 관리 도구 개발)

  • Cho, Woong;Lee, Jaegi;Kim, Hyun Suk;Wu, Hong-Gyun
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.233-241
    • /
    • 2014
  • The aim of this study is to develop a new software tool for 3D dose verification using $PRESAGE^{REU}$ Gel dosimeter. The tool included following functions: importing 3D doses from treatment planning systems (TPS), importing 3D optical density (OD), converting ODs to doses, 3D registration between two volumetric data by translational and rotational transformations, and evaluation with 3D gamma index. To acquire correlation between ODs and doses, CT images of a $PRESAGE^{REU}$ Gel with cylindrical shape was acquired, and a volumetric modulated arc therapy (VMAT) plan was designed to give radiation doses from 1 Gy to 6 Gy to six disk-shaped virtual targets along z-axis. After the VMAT plan was delivered to the targets, 3D OD data were reconstructed from 512 projection data from $Vista^{TM}$ optical CT scanner (Modus Medical Devices Inc, Canada) per every 2 hours after irradiation. A curve for converting ODs to doses was derived by comparing TPS dose profile to OD profile along z-axis, and the 3D OD data were converted to the absorbed doses using the curve. Supra-linearity was observed between doses and ODs, and the ODs were decayed about 60% per 24 hours depending on their magnitudes. Measured doses from the $PRESAGE^{REU}$ Gel were well agreed with the TPS doses at central region, but large under-doses were observed at peripheral region at the cylindrical geometry. Gamma passing rate for 3D doses was 70.36% under the gamma criteria of 3% of dose difference and 3 mm of distance to agreement. The low passing rate was resulted from the mismatching of the refractive index between the PRESAGE gel and oil bath in the optical CT scanner. In conclusion, the developed software was useful for 3D dose verification from PRESAGE gel dosimetry, but further improvement of the Gel dosimetry system were required.

A Model for Health Promoting Behaviors in Late-middle Aged Woman (중년후기 여성의 건강증진행위 모형구축)

  • Park, Chai-Soon
    • Women's Health Nursing
    • /
    • v.2 no.2
    • /
    • pp.298-331
    • /
    • 1996
  • Recent improvements in living standard and development in medical care led to an increased interest in life expectancy and personal health, and also led to a more demand for higher quality of life. Thus, the problem of women's health draw a fresh interest nowadays. Since late-middle aged women experience various physical and socio-psychological changes and tend to have chronic illnesses, these women have to take initiatives for their health control by realizing their own responsibility. The basic elements for a healthy life of these women are understanding of their physical and psychological changes and acceptance of these changes. Health promoting behaviors of an individual or a group are actions toward increasing the level of well-being and self-actualization, and are affected by various variables. In Pender's health promoting model, variables are categorized into cognitive factors(individual perceptions), modifying factors, and variables affecting the likelihood for actions, and the model assumes the health promoting behaviors are affected by cognitive factors which are again affected by demographic factors. Since Pender's model was proposed based on a tool broad conceptual frame, many studies done afterwards have included only a limited number of variables of Pender's model. Furthermore, Pender's model did not precisely explain the possibilities of direct and indirect paths effects. The objectives of this study are to evaluate Pender's model and thus propose a model that explains health promoting behaviors among late-middle aged women in order to facilitate nursing intervention for this group of population. The hypothetical model was developed based on the Pender's health promoting model and the findings from past studies on women's health. Data were collected by self-reported questionnaires from 417 women living in Seoul, between July and November 1994. Questionnaires were developed based on instruments of Walker and others' health promotion lifestyle profile, Wallston and others' multidimensional health locus of control, Maoz's menopausal symptom check list and Speake and others' health self-rating scale. IN addition, items measuring self-efficacy were made by the present author based on past studies. In a pretest, the questionnaire items were reliable with Cronbach's alpha ranging from .786 to .934. The models for health promoting behaviors were tested by using structural equation modelling technique with LISREL 7.20. The results were summarized as follows : 1. The overall fit of the hypothetical model to the data was good (chi-square=4.42, df=5, p=.490, GFI=.995, AGFI=.962, RMSR=.024). 2. Paths of the model were modified by considering both its theoretical implication and statistical significance of the parameter estimates. Compared to the hypothetical model, the revised model has become parsimonious and had a better fit to the data (chi-square =4.55, df=6, p=.602, GFI=.995, AGFI=.967, RMSR=.024). 3. The results of statistical testing were as follows : 1) Family function internal health locus of control, self-efficacy, and education level exerted significant effects on health promoting behaviors(${\gamma}_{43}$=.272, T=3.714; ${\beta}_[41}$=.211, T=2.797; ${\beta}_{42}$=.199, T=2.717; ${\gamma}_{41}$=.136, T=1.986). The effect of economic status, physical menopausal symptoms, and perceived health status on health promoting behavior were insignificant(${\gamma}_{42}$=.095, T=1.456; ${\gamma}_{44}$=.101, T=1.143; ${\gamma}_{43}$=.082, T=.967). 2) Family function had a significance direct effect on internal health locus of control (${\gamma}_{13}$=.307, T=3.784). The direct effect of education level on internal health locus of control was insignificant(${\gamma}_{11}$=-.006, T=-.081). 3) The directs effects of family functions & internal health locus of control on self-efficacy were significant(${\gamma}_{23}$=.208, T=2.607; ${\beta}_{21}$=.191, T=2.2693). But education level and economic status did not exert a significant effect on self-efficacy(${\gamma}_{21}$=.137, T=1.814; ${\beta}_{22}$=.137, T=1.814; ${\gamma}_{22}$=.112, T=1.499). 4) Education level had a direct and positive effect on perceived health status, but physical menopausal symptoms had a negative effect on perceived health status and these effects were all significant(${\gamma}_{31}$=.171, T=2.496; ${\gamma}_{34}$=.524, T=-7.120). Internal health locus and self-efficacy had an insignificant direct effect on perceived health status(${\beta}_{31}$=.028, T=.363; ${\beta}_{32}$=.041, T=.557). 5) All predictive variables of health promoting behaviors explained 51.8% of the total variance in the model. The above findings show that health promoting behaviors are explained by personal, environmental and perceptual factors : family function, internal health locus of control, self-efficacy, and education level had stronger effects on health promoting behaviors than predictors in the model. A significant effect of family function on health promoting behaviors reflects an important role of the Korean late-middle aged women in family relationships. Therefore, health professionals first need to have a proper evaluation of family function in order to reflect the family function style into nursing interventions and development of strategies. These interventions and strategies will enhance internal health locus of control and self-efficacy for promoting health behaviors. Possible strategies include management of health promoting programs, use of a health information booklets, and individual health counseling, which will enhance internal health locus of control and self-efficacy of the late-middle aged women by making them aware of health responsibilities and value for oneself. In this study, an insignificant effect of physical menopausal symptoms and perceived health status on health promoting behaviors implies that they are not motive factors for health promoting behaviors. Further analytic researches are required to clarify the influence of physical menopausal symptoms and perceived health status on health promoting behaviors with-middle aged women.

  • PDF