Development of Program for Renal Function Study with Quantification Analysis of Nuclear Medicine Image

핵의학 영상의 정량적 분석을 통한 신장기능 평가 프로그램 개발

  • Song, Ju-Young (Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea) ;
  • Lee, Hyoung-Koo (Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea) ;
  • Suh, Tae-Suk (Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea) ;
  • Choe, Bo-Young (Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea) ;
  • Shinn, Kyung-Sub (Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea) ;
  • Chung, Yong-An (Department of Radiology, College of Medicine, The Catholic University of Korea) ;
  • Kim, Sung-Hoon (Department of Radiology, College of Medicine, The Catholic University of Korea) ;
  • Chung, Soo-Kyo (Department of Radiology, College of Medicine, The Catholic University of Korea)
  • 송주영 (가톨릭대학교 의과대학 의공학교실) ;
  • 이형구 (가톨릭대학교 의과대학 의공학교실) ;
  • 서태석 (가톨릭대학교 의과대학 의공학교실) ;
  • 최보영 (가톨릭대학교 의과대학 의공학교실) ;
  • 신경섭 (가톨릭대학교 의과대학 의공학교실) ;
  • 정용안 (가톨릭대학교 의과대학 방사선과학교실) ;
  • 김성훈 (가톨릭대학교 의과대학 방사선과학교실) ;
  • 정수교 (가톨릭대학교 의과대학 방사선과학교실)
  • Published : 2001.04.30

Abstract

Purpose: In this study, we developed a new software tool for the analysis of renal scintigraphy which can be modified more easily by a user who needs to study new clinical applications, and the appropriateness of the results from our program was studied. Materials and Methods: The analysis tool was programmed with IDL5.2 and designed for use on a personal computer running Windows. For testing the developed tool and studying the appropriateness of the calculated glomerular filtration rate (GFR), $^{99m}Tc$-DTPA was administered to 10 adults in normal condition. In order to study the appropriateness of the calculated mean transit time (MTT), $^{99m}Tc-DTPA\;and\;^{99m}Tc-MAG3$ were administered to 11 adults in normal condition and 22 kidneys were analyzed. All the images were acquired with ORBITOR. the Siemens gamma camera. Results: With the developed tool, we could show dynamic renal images and time activity curve (TAC) in each ROI and calculate clinical parameters of renal function. The results calculated by the developed tool were not different statistically from the results obtained by the Siemens application program (Tmax: p=0.68, Relative Renal Function: p:1.0, GFR: p=0.25) and the developed program proved reasonable. The MTT calculation tool proved to be reasonable by the evaluation of the influence of hydration status on MTT. Conclusion: We have obtained reasonable clinical parameters for the evaluation of renal function with the software tool developed in this study. The developed tool could prove more practical than conventional, commercial programs.

목적: 감마카메라로부터 획득한 신장 영상의 정량적 분석을 통해 신장 기능 평가시 사용되고 있는 기존 상용 프로그램은 사용자 임의의 기능 변경 및 추가가 어려워 응용적 측면에서 단점을 갖고 있다. 이 연구에서는 이러한 기존 상용프로그램의 단점을 극복하고, 사용자가 임상 필요에 따라 기능 변경 및 추가를 쉽게 할 수 있는 분석 프로그램을 개발하여 그 결과의 타당성을 분석하였다. 대상 및 방법: 개발된 프로그램은 IDL5.2를 사용하여 작성하였으며, windows운영시스템의 일반 개인용 컴퓨터에서 구현토록 하였다. 프로그램의 기본 성능 구현 및 사구체여과율 계산값의 타당성 검증을 위한 영상자료를 얻기 위해 10명의 정상인을 대상으로 $^{99m}Tc$-DTPA 방사성의약품을 사용하였고, 평균통과시간 계산값의 타당성 검증을 위한 영상자료를 얻기 위해 정상인 11명의 22개의 신장을 대상으로 $^{99m}Tc$-DTPA와 $^{99m}Tc$-MAG3를 사용하여 수분공급에 따른 평균통과시간 분석을 시행하였다. 신장영상은 Siemens사의 단일헤드 감마카메라(ORBITOR)를 통해 획득하였다. 정량적 분석을 위한 관심영역 설정은 수동설정 외에 자동설정 기능도 함께 개발하여 구현토록 하였다. 사구체여과율 계산을 위해 Gates방법을 사용하였고, 평균통과시간 계산을 위해 역중첩 방법과 적합한 여과 방법을 적용하여 안정된 값을 구하였다. 결과: 개발한 프로그램으로 시간별 신장영상과 각 관심영역 내에서의 시간방사능곡선을 도시할 수 있었고, 사구체여과율, 평균통과시간 및 좌 우 신장의 상대적 기능 외에 각 관심영역에서 최대방사능도달시간($T_{max}$)과 중간방사능도달시간($T_{1/2}$)과 같은 시간방사능곡선과 관련된 값들도 함께 계산하였다. 10명의 신장 영상 자료를 대상으로 개발된 프로그램으로 분석한 값들과 Siemens사의 기존 상용 분석 프로그램(MPE)으로 계산한 값들을 서로 비교, 분석한 결과, 통계학적으로 차이가 없음(최대 방사능도달시간: p=0.68, 상대신장기능: p=1.0, 사구체여과율: p=0.25)을 보여 개발한 프로그램이 타당성이 있음을 입증하였다. 평균통과시간 계산값의 타당성 검토와 관련하여, Siemens사의 상용 분석 프로그램에는 해당 기능이 없어 계산값의 비교를 통한 검증은 수행하지 못하였고, 수화(hydration)와 탈수(dehydration) 각각의 조건에 따른 신장기능 분석에 적용하였을 때, 판별 기준이 되는 유의미한 값을 산출하여 타당성 검증을 대신하였다. 결론: 이 연구에서 개발한 핵의학 영상의 정량적 분석을 통한 신장기능 분석 프로그램을 사용하여 신장 기능을 분석한 결과, 타당성 있는 결과를 도출하여 그 유용성을 입증하였다. 이 개발 프로그램은 좀 더 다양한 임상응용 목적의 분석기능을 사용자가 직접 개발, 추가하기가 용이하여 기존 상용 프로그램보다 연구적 활용범위가 크다고 사료된다.

Keywords