• Title/Summary/Keyword: gamma correction

Search Result 198, Processing Time 0.022 seconds

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

Improved characterization method for mobile phone camera and LCD display (모바일 폰 카메라와 LCD의 향상된 특성화 방법)

  • Jang, In-Su;Son, Chang-Hwan;Lee, Cheol-Hee;Song, Kun-Woen;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.65-73
    • /
    • 2008
  • The characterization process for the accurate color reproduction in mobile phone with camera and LCD is popular. The camera and LCD characterization, gamut mapping process is necessary to map the camera's input color stimulus, CIEXYZ value, into the LCD's output color stimulus. Each characterization is the process estimating the relation between input and output signals. In case of LCD, because of output device, the output color stimulus for the arbitrary input signal can be measured by spectro-radiometer However, in the camera, as the input device, the characterization is an inaccurate and needs the manual works in the process obtaining the output signal because the input signal can not be generated. Moreover, after gamut mapping process, the noise is increased because the optimized gamma tone curve of camera for the noise is distorted by the characterization. Thus, this paper proposed the system of obtaining the output signal of camera and the method of gamma correction for the noise. The camera's output signal is obtained by RGB values of patches from captured the color chart image. However, besides the illumination, the error for the location of the chart in the viewfinder is generated when many camera modules are captured the chart. The method of correcting the position to correct the error from manual works. The position of camera is estimated by captured image. This process and moving of camera is accomplished repeatedly, and the optimized position can be obtained. Moreover, the lightness curve of camera output is corrected partly to reduce the noise from the characterization process.

Surgical Correction of Peritoneopericardial Diaphragmatic Hernia with Hepatic Necrosis in a Himalayan Cat (히말라얀 고양이에서 간괴사를 동반한 복막심낭횡격막 허니아의 외과적 치료)

  • Kim, Joon-young;Jeong, Soon-wuk;Park, Bo-yeon;Go, Hiw-gon;Yoon, Hun-young;Jeong, Man-bok;Han, Hyun-jung;Min Hwang;No, Byung-kuk
    • Journal of Veterinary Clinics
    • /
    • v.21 no.1
    • /
    • pp.45-48
    • /
    • 2004
  • A five months old, female Himalayan cat was referred to the Veterinary Medical Teaching Hospital at Konkuk University, because of suspecting peritoneopericardial diaphragmatic hernia (PPDH). After consecutive examination, the patient was diagnosed as PPDH and hepatic dysfunction. In spite of medical therapy for a month, the serum chemistry profiles for liver enzymes (aspartate transferase: 469 U/L, alanine transferase: above analysis, gamma-glutamyl transferase: above analysis) did not decrease to the normal range. In operation, some of liver was necrotized and was adhesive to diaphragm, these were gently dissected from thoracic structures, and resected. After debriding, the edges of the defect of diaphragm were closed with a simple continuous suture pattern. One month after operation, the cat had normal condition, recovery was uncomplicated, and the serum chemistry profiles for liver enzymes decrease to the normal range.

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy (2차원 토모테라피 선량측정시스템의 정성적 평가)

  • Ma, Sun Young;Jeung, Tae Sig;Shim, Jang Bo;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • The purpose of this study is to see the feasibility of the newly developed 2D dosimetry system using phosphor screen for helical tomotherapy. The cylindrical water phantom was fabricated with phosphor screen to emit the visible light during irradiation. There are three types of virtual target, one is one spot target, another is C-shaped target, and the other is multiple targets. Each target was planned to be treated at 10 Gy by treatment planning system (TPS) of tomotherapy. The cylindrical phantom was placed on the tomotherapy table and irradiated as calculations of the TPS. Every frame which acquired by CCD camera was integrated and the doses were calculated in pixel by pixel. The dose distributions from the fluorescent images were compared with the calculated dose distribution from the TPS. The discrepancies were evaluated as gamma index for each treatment. The curve for dose rate versus pixel value was not saturated until 900 MU/min. The 2D dosimetry using the phosphor screen and the CCD camera is respected to be useful to verify the dose distribution of the tomotherapy if the linearity correction of the phosphor screen improved.

Reduction of Color Distortion by Estimating Dominant Chromaticity in Multi-Scaled Retinex (다중 Retinex 알고리즘에서 주색도 추정을 이용한 색상 왜곡 보정)

  • Jang, In-Su;Park, Kee-Hyon;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.3
    • /
    • pp.52-59
    • /
    • 2009
  • In general, methods based on histogram or a correction of gamma curve are usually utilized to enhance the contrast of captured image in the dark scene. These methods are efficient to enhance the contrast globally, however, they locally induced the low quality of image. Recently, to resolve the problem, the multi-scaled refiner algorithm improving the contrast with locally averaged lightness is proposed. However, estimating the locally averaged lightness, if there is the object with a high saturated color, the color distortion might be induced by the color of object. Thus, in this paper, the dominant chromaticity of image is estimated to correct the locally averaged lightness in multi-scaled retinex algorithm. Because the average chromaticity of image includes the chromaticity of illumination, the dominant chromaticity is estimated with dividing the average chromaticity of image by the estimated chromaticity of illumination from highlight region. In addition, to improve the lower chroma by multi-scaled retinex algorithm generally, the chroma was compensated preserving the hue in the CIELAB color space.

A Dithering Based Technique for Improving Gray Level Reproduction Capability in Dark Areas on Plasma Display Panels (플라즈마 디스플레이의 어두운 영역에서의 계조 표현 향상을 위한 디더링 방법)

  • Park, Seung-Ho;Kim, Chun-U
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Because of the reduced number of displayable gray levels resulting from inverse gamma correction, images on a plasma display panel (PDP) exhibit undesirable false contours in dark areas. An error diffusion method has been applied to remedy this problem. However, it is computationally expensive and requires large memory resources. This paper proposes a computationally efficient dithering based technique to improve the gray level reproduction capability in dark areas. In the proposed method, multiple dithering masks ate utilized in turn to improve the gray level reproduction in dark areas. Also, in order to reduce undesirable regular patterns generated by the dithering method, positions of threshold values within a given dithering mask are changed. Compared to the error diffusion method, the proposed method requires much less computations and memory resources with a comparable gray level reproduction capability.

Development of the Estimation Model on Daily Pollutant Loads for the Watersheds in the Nakdong River Basin I. Correction and Verification for the Model (낙동강 유역에 대한 일별 유달부하량 산정모델개발 I. 모델식의 보정 및 검증)

  • Yoon, Young-Sam;Kim, Moon-Soo;Yu, Jae-Jung;Lee, Hae-Jin;Lee, Jun-Bae;Yang, Sang-Yong
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.203-210
    • /
    • 2007
  • The delivery load data obtained from Nakdong river basin are used for developing the model estimating the daily delivery load on the main side streams of Nakdong River. The developed model assesses the daily contamination loads of the main thirteen side streams that contribute to the main stream of Nakdong river. It is developed that the model using the simplified equation that can estimate the daily delivery loads on the side main streams of Nakdong river for a period of having no data of the water quality and flow. The developed model for estimating the daily delivery loads from the main side streams in Nakdong river basin on each item such as BOD, TN, and TP is expressed as Daily delivery load ($\frac{kg}{day}$) = Production load $(\frac{kg}{day}){\times}(1-{\alpha}){\times}(\frac{daily\;runoff}{average\;runoff\;per\;year}){\gamma}$. The estimated values obtained by using the model are almost fit to the calculated values (real data) that have been acquired from the thirteen main side streams in Nakdong river basin. The correlation coefficient values, R, that indicate the correlation between the estimated and the calculated show over 0.7 that mean the estimated values from the used model are adapted to the real data except TN values of Nam-river, Hwang-river, Gam-river, We-river. Especially, the correlation of TP values between the estimated and the calculated implies quite a creditable data to use.

Dose modeling and its Application of Ir-192 for substitution of Ralstron Brachytherapy source (Ralstron 선원대체형 Iridium-192 선원의 선량모델링과 응용)

  • 김옥배;최태진;김진희;이호준;박정호;김성규;조운갑;한현수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.131-139
    • /
    • 2000
  • We designed high dose rate Ir-192 source which was prepared for substitute the Co-60 source in Ralstron unit (Simatsu, Japan) which is supplied for cervical cancer treatment. The source dimension is 1.5 mm in a diameter and 1.5mm thickness of cylinder and encapsulated with 3 mm diameter of stainless steel(SUS316L) to substituted for the Co-60 source size. The Ir-192 source was prepared the dose model for tissue dose computation through the experimental determination of apparent activity and applied the empirical tissue correction factors extended to 20cm distance. The tissue dose model was applied the 4.69 R/cm-mCi-hr gamma constant and the ratio of energy absorption coefficient of water to that of air showed 1.112 include filteration of the self-absorptions. In this experiments, we prepared the dose computation software to clinical usefulness.

  • PDF

An investigation of lead absorption in an electric accumulator factory with the use of personal samplers

  • Williams M.K.;King E.;Walford Joan
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.561-575
    • /
    • 1994
  • Williams, M K., King, E., and Walford, Joan (1969). Brit. J. industr. Med., 26, 202-216. An investigation of lead absorption in an electric accumulator factory with the use of personal samplers. Thirty-nine lead workers and controls, in stable conditions of exposure, each wore personal lead-in-air samplers daily for two weeks. During the second week samples for blood lead, urinary lead, urinary coproporphyrin, urinary $\gamma$-aminolevulinic acid (ALA), the punctate basophil count, and haemoglobin were taken daily. Duplicate estimations were made on one day. The lead exposures of men doing almost identical jobs differed by ratios of up to four to one. This could be attributed on y to personal differences in working habits. The correlation coefficients and regression equations of the biochemical tests with lead-in-air and with each other were determined. The mean values and $95\%$ confidence limits of single determinations of some of the biochemical tests corresponding to the two commonly accepted TLVs of lead-in-air (0-20 and 0-15 mg./$m^{3}$) were calculated from the regression equations. For each biochemical test the variation due to analytical error, the variation from day to day within subjects and the residual variation about the regression on lead-in-air were calculated. Previous estimates of the latter are not known. Excessive confidence may be placed in an index of exposure due to its low coefficient of variation within subjects unless the coefficient of variation between subjects about regression is taken into account. The correction for specific gravity of estimations of lead and ALA in spot samples of urine was found to reduce slightly the residual variation between subjects about the regression on lead-in-air and to increase the correlations with lead-in-air and with the other biochemical tests, but these changes were not statistically significant. The modified method used for estimating blood lead and urinary lead is described and validated.

  • PDF

A Novel Luminance Adaptation Effect Model in Pixel Intensity Domain for Image Quality Assessment: Theory and Application (영상 화질 측정을 위한 픽셀 강도 영역의 새로운 광적응 효과 모델: 이론 및 적용)

  • Bae, Sung-Ho;Kim, Munchurl
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.07a
    • /
    • pp.78-80
    • /
    • 2015
  • 광적응(Luminance Adaptation; LA) 효과는 영상의 배경 밝기에 따른 왜곡에 대한 시각 인지 민감도가 달라지는 특성을 의미한다. 기존 영상 화질 측정(Image Quality Assessment; IQA) 방법들은 베버의 법칙(Weber' s law) 모델을 이용하여 LA 효과를 IQA 방법에 반영해왔다. 그러나, 이러한 IQA 방법들에 있어서 베버의 법칙 기반 LA 효과 모델은 다음 두 가지 이유로 부정확하게 동작한다: (i) 전통적인 베버의 법칙 모델은 실제 광도(luminance)에 대한 인지 민감도 응답값을 정확히 반영할 수 없다는 것이 밝혀졌다, (ii) 대부분 IQA 방법들은 픽셀 강도 영역에서 계산되지만, 베버의 법칙과 같은 LA 효과 모델들은 광도 영역에서 개발되었다. 따라서 광도와 픽셀 강도간 비선형 관계로 인해 IQA 방법에 반영된 베버의 법칙 기반 LA 효과 모델들은 부정확하게 동작한다. 이 문제를 해결하기 위해, 본 논문에서 처음으로 픽셀 강도 영역에서의 LA 모델을 이론적으로 유도한다. 본 논문에서 제안하는 픽셀 강도 영역에서의 LA 효과 모델은 감마 교정 함수(Gamma correction function)와 광도 영역에서의 LA 효과 모델인 제곱-법칙(power-law) 모델을 기반으로 하는 테일러 급수 확장 근사화를 통해 유도된다. 제안하는 픽셀 강도 영역 LA 효과 모델의 효과를 검증하기 위해, 제안하는 LA 효과 모델을 PSNR 에 도입하여 광범위한 실험을 수행한다. 실험 결과, 제안하는 LA 효과 모델 기반 PSNR 은 PSNR 및 베버의 법칙 기반 PSNR 대비 괄목할 만한 주관적 화질 예측 성능 향상을 보였다.

  • PDF