• Title/Summary/Keyword: gamma correction

Search Result 198, Processing Time 0.027 seconds

The Availability Examination for Vegetation Measurement of The SLR Digital Camera (SLR 디지털카메라의 식생관측센서로서의 유효성 검토)

  • Kim, Jong-Hwan;Kim, Eung-Nam;Jun, Byung-Dug;K., Sugiyama
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.1
    • /
    • pp.683-692
    • /
    • 2009
  • On-site remote sensing technique by using single lens reflex(SLR) digital camera will be expected as the useful tool for the vegetation measurement field such as a crop growth management, the monitoring of revegetation slope and the evaluation of environment. We reviewed the availability of the vegetation measurement using a digital camera which is sailed for general-purpose. As a result, we could analysis relationship with the illuminance of image plane and incidence energy of multitemporal observation images by doing gamma correction and exposure compensation. And also, we proposed the model formulas for the correction of influences of capturing angle and illuminance. In addition, we obtained high correlation of normalized difference vegetation index(NDVI) between digital camera and spectral photometer.

Recent Developments in Nuclear Medicine Instrumentation (최근 핵의학 영상 기기 발전 동향)

  • Kim, Joon-Young;Choi, Yong;Kim, Jong-Ho;Im, Ki-Chun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Sang-Eun;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.471-481
    • /
    • 1998
  • The goals of developments in nuclear medicine instrumentation are to offer a higher-quality image and to aid diagnosis, prognosis assessment or treatment planning and monitoring. It is necessary for physicists and engineers to improve or design new instrumentation and techniques, and to implement, validate, and apply these new approaches in the practice of nuclear medicine. The researches in physical properties of detectors and crystal materials and advances in image analysis technology have improved quantitative and diagnostic accuracy of nuclear medicine images. This review article presents recent developments in nuclear medicine instrumentation, including scatter and attenuation correction, new detector technology, tomographic image reconstruction methods, 511 keV imaging, dual modality imaging device, small gamma camera, PET developments, image display and analysis methods.

  • PDF

Road Image Enhancement Method for Vision-based Intelligent Vehicle (비전기반 지능형 자동차를 위한 도로 주행 영상 개선 방법)

  • Kim, Seunggyu;Park, Daeyong;Choi, Yeongwoo
    • Korean Journal of Cognitive Science
    • /
    • v.25 no.1
    • /
    • pp.51-71
    • /
    • 2014
  • This paper presents an image enhancement method in real road traffic scenes. The images captured by the camera on the car cannot keep the color constancy as illumination or weather changes. In the real environment, these problems are more worse at back light conditions and at night that make more difficult to the applications of the vision-based intelligent vehicles. Using the existing image enhancement methods without considering the position and intensity of the light source and their geometric relations the image quality can even be deteriorated. Thus, this paper presents a fast and effective method for image enhancement resembling human cognitive system which consists of 1) image preprocessing, 2) color-contrast evaluation, 3) alpha blending of over/under estimated image and preprocessed image. An input image is first preprocessed by gamma correction, and then enhanced by an Automatic Color Enhancement(ACE) method. Finally, the preprocessed image and the ACE image are blended to improve image visibility. The proposed method shows drastically enhanced results visually, and improves the performance in traffic sign detection of the vision based intelligent vehicle applications.

Motion Control Algorithm Expanding Arithmetic Operation for Low-Cost Microprocessor (저가형 마이크로프로세서를 위한 연산처리 확장 모션제어 알고리즘)

  • Moon, Sang-Chan;Kim, Jae-Jun;Nam, Kyu-Min;Kim, Byoung-Soo;Lee, Soon-Geul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.12
    • /
    • pp.1079-1085
    • /
    • 2012
  • For precise motion control, S-curve velocity profile is generally used but it has disadvantage of relatively long calculation time for floating-point arithmetics. In this paper, we present a new generating method for velocity profile to reduce delay time of profile generation so that it overcomes such disadvantage and enhances the efficiency of precise motion control. In this approach, the velocity profile is designed based on the gamma correction expression that is generally used in image processing to obtain a smoother movement without any critical jerk. The proposed velocity profile is designed to support both T-curve and S-curve velocity profile. It can generate precise profile by adding an offset to the velocity profile with decimals under floating point that are not counted during gamma correction arithmetic operation. As a result, the operation time is saved and the efficiency is improved. The proposed method is compared with the existing method that generates velocity profile using ring buffer on a 8-bit low-cost MCU. The result shows that the proposed method has no delay in generating driving profile with good accuracy of each cycle velocity. The significance of the proposed method lies in reduction of the operation time without degrading the motion accuracy. Generated driving signal also shows to verify effectiveness of the proposed method.

Theoretical Calculation of Activity Coefficients of Liquid Mixtures (액체혼합물의 활동도계수의 이론적 계산)

  • Moon Dae-Won;Jhon Mu Shik;Lee Taikyue
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.6
    • /
    • pp.395-403
    • /
    • 1977
  • Significant structure theory was applied to some liquid mixture systems ranging from simple monatomic molecule systems to polyatomic molecule systems, and the activity coefficients ${\gamma}$ of the liquid mixture systems were calculated over whole mole fractions using the following thermodynamic relation $RTln_{{\gamma}i} = (\frac{{\partial A}^E}{{\partial N}_i})_{T,V,N_i} $ where $A^E$ represents the excess Helmholtz free energy, and $N_i$ is the number of molecules of component i. The activity coefficients of the solutions such as monatomic molecule systems (Ar-Kr, Kr-Xe) and diatomic molecule systems $(Ar-O_2,\;N_2-CO)$ and $CH_4-Kr$ systems whose components have similar shapes for intermolecular potential curves were calculated successfully only with the ${\delta}E_s$, correction parameter for energy $E_s$, for mixture systems. For other systems such as $Ar-N_2,\;O_2-N_2\;and\;CH_4-C_3H_8$ whose components have dissimilar intermolecular potential curve shapes an additional correction parameters ${\delta}$V and even one more parameter ${\delta}$n were necessary [see Eqs.(10)∼(12)].

  • PDF

Verification of Extended Source-To-Imager Distance (SID) Correction for Portal Dosimetry

  • Son, Jaeman;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.137-142
    • /
    • 2018
  • This study aimed to evaluate and verify a process for correcting the extended source-to-imager distance (SID) in portal dosimetry (PD). In this study, eight treatment plans (four volumetric modulated arc therapy and four intensity-modulated radiation therapy plans) at different treatment sites and beam energies were selected for measurement. A Varian PD system with portal dose image prediction (PDIP) was used for the measurement and verification. To verify the integrity of the plan, independent measurements were performed with the MapCHECK device. The predicted and measured fluence were evaluated using the gamma passing rate. The output ratio was defined as the ratio of the absolute dose of the reference SID (100 cm) to that of each SID (120 cm or 140 cm). The measured fluence for each SID was absolutely and relatively compared. The average SID output ratios were 0.687 and 0.518 for 120 SID and 140 SID, respectively; the ratio showed less than 1% agreement with the calculation obtained by using the inverse square law. The resolution of the acquired EPIDs were 0.336, 0.280, and 0.240 for 100, 120, and 140 SID, respectively. The gamma passing rates with PD and MapCHECK exceeded 98% for all treatment plans and SIDs. When autoalignment was performed in PD, the X-offset showed no change, and the Y-offset decreased with increasing SID. The PD-generated PDIP can be used for extended SID without additional correction.

Improvement of the Accuracy of Fringe Pattern Profilometry 3D Measurements through Phase Correction (위상 보정을 통한 Fringe Pattern Profilometry 3D 측정의 정확성 개선)

  • Kim, Ho-Joong;Cho, Tai-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.389-392
    • /
    • 2016
  • As technologies evolve, 3D measurement techniques using cameras have been developed continuously. In 3D measurement, high accuracy, fast speed, and easy implementation are very important factors. Recently, 3D measurement using multi-frequency fringes has been widely used. This method is generally a method of measuring the height of a image obtained by projecting a sine wave through the projector. The sine wave is produced by software. However, this sine wave is not a perfect sine wave by gamma of projector. This is given a bad influence on the height measurement, and can not measure the correct height. In this paper, we propose a method for correcting the phase of the sine wave to avoid being affected gamma. Through this method it will be able to make more accurate height measurement.

  • PDF

The Effect of Applying Self-absorption and Coincidence Summation Correction when Measuring Environmental Samples (환경시료 측정 시 자체흡수 및 동시합성 보정 적용 효과)

  • Eun-Sung Jang;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.531-539
    • /
    • 2023
  • Self-absorption is the most important factor affecting the accuracy of gamma spectroscopy measurements in environmental samples. In particular, it is affected by other factors such as the chemical composition of the sample, geometric shape, thickness, density, atomic number, distance between the sample and detector, energy of the emitted gamma photon, and humidity coefficient or percentage in the sample. To test the calibration method, a 450 ml CRM standard source (9 nuclide) Marinelli beaker was used. Five soil samples among environmental samples were measured by density by applying the corrected values. Therefore, it can be seen that the self-absorption value is more effective for somewhat large and low photon energy. In the case of environmental samples, it was confirmed that the overall energy peak efficiency through self-absorption of the source greatly depends on the density of the sample.

Optimization of image reconstruction method for dual-particle time-encode imager through adaptive response correction

  • Dong Zhao;Wenbao Jia;Daqian Hei;Can Cheng;Wei Cheng;Xuwen Liang;Ji Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1587-1592
    • /
    • 2023
  • Time-encoded imagers (TEI) are important class of instruments to search for potential radioactive sources to prevent illicit transportation and trafficking of nuclear materials and other radioactive sources. The energy of the radiation cannot be known in advance due to the type and shielding of source is unknown in practice. However, the response function of the time-encoded imagers is related to the energy of neutrons or gamma-rays. An improved image reconstruction method based on MLEM was proposed to correct for the energy induced response difference. In this method, the count vector versus time was first smoothed. Then, the preset response function was adaptively corrected according to the measured counts. Finally, the smoothed count vector and corrected response were used in MLEM to reconstruct the source distribution. A one-dimensional dual-particle time-encode imager was developed and used to verify the improved method through imaging an Am-Be neutron source. The improvement of this method was demonstrated by the image reconstruction results. For gamma-ray and neutron images, the angular resolution improved by 17.2% and 7.0%; the contrast-to-noise ratio improved by 58.7% and 14.9%; the signal-to-noise ratio improved by 36.3% and 11.7%, respectively.

ALGORITHM DEVELOPMENT FOR POSITION CORRECTIONS OF FIMS DATA (FIMS 관측 자료의 위치보정 알고리즘 개발)

  • Lim, Y.M.;Seon, K.I.;Min, K.;Ryu, K.S.;Park, J.W.;Kim, I.J.;Shinn, J.H.;Lee, D.H.
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.135-141
    • /
    • 2005
  • The FIMS(Far-ultraviolet IMaging Spectrograph), the main payload onboard the first Korean Science Technology SATellite, STSAT-1, has performed various astronomical observations, including the Cygnus Loop, Vela supernova remnants, LMC(Large Magellanic Cloud), since its launch on September 2003. It has been found that the attitude information provided by spacecraft bus system has the errors of more than about 10-15 arcmins due to the time offset problem and errors in attitude knowledge. We develop an algorithm for correction of position errors in FIMS data. The aspect for the FIMS data is determined by comparing the positions of observed bright stars with the Tycho-II and TD-1 catalogs. The position errors of the bright stars along the scanning (${\gamma}$) and spatial (${\delta}$) directions were considered as functions of ${\delta}$, ignoring errors in position angle. The corrected positions of the bright stars coincided very well to their Tycho-II and TD-I positions. The correction algorithm is essential for the FIMS data analysis, and is being used for the FIMS data analysis.