• Title/Summary/Keyword: g-jitter

Search Result 47, Processing Time 0.03 seconds

A Study of the Correlation between Subjective and Objective Evaluation of Voice Disorders (음성장애 주관적 평가와 객관적 평가 간의 상관성 연구)

  • Lee, Ok-Bun;Kim, So-Yeon
    • Phonetics and Speech Sciences
    • /
    • v.3 no.3
    • /
    • pp.167-172
    • /
    • 2011
  • The purpose of this study was to examine the relationship between subjective and objective evaluation in speakers with voice disorders. Subjective evaluation indicates the self-reports of voice problems by dysphonic speakers. The relating protocol is the Voice Handicap Index (VHI) and the self-awareness index of voice problems (SAIVP-14). A total of 48 individuals with voice disorders replied to the questionnaire and participated in a voice assessment. Objective evaluations included the perceptual judgement of G grade in GRBAS, acoustic measurements (jitter, shimmer, NHR) by MDVP (CSL 4400), and aerodynamic measurements (MPT, MFR, psub) by PAS (Phonatory Aerodynamic System, KayPentax, USA). Pearson and Spearman correlations were used for the analysis. In the correlation with perceptual judgement (G grade) and VHI-Total, VHI-Physical, and SAIVP-14, there was a significant correlation, but the overall correlation was poor. NHR, jitter, and shimmer were significantly correlated with overall VHI and SAIVP-14. Specifically, the correlation with shimmer was stronger compared to the other measurements. In aerodynamic measures, MFR and MPT showed a significant correlation with VHI-Total, VHI-Emotional, and SAIVP-14, but their correlation was poor. The results of this study suggested that subjective evaluation of self voice problems is meaningfully correlated with objective evaluations, but more data in the multidimensional voice assessment should be collected and analyzed for the reliability and validity of the voice handicap questionnaire.

  • PDF

Performance Analysis on Clock Sychronization of CCK Modulation Scheme in Wireless LAN System (무선 LAN 시스템에서 CCK 변조방식의 클럭 동기 성능 분석)

  • 박정수;강희곡;조성언;조성준
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.583-586
    • /
    • 2004
  • In this paper, we have analyzed the performance of synchronization of CCK(Complementary Code Keying) modulation scheme used for IEEE 802.11g wireless LAM system supporting 54 Mbps of high speed data rate over 2.4 GHz. At receiver, the clock frequency offset is caused by noise or fading. This frequency error occurs the offset of clock timing and causes ISI. Therefore the tracking is required to reduce the clock timing offset. The DLL(Delay Lock Loop), asychronization mode, performing tacking the clock is used for the simulation. The simulation result shows jitter variance and BER performance in the AWGN and multipath fading channel environment.

  • PDF

Study on Optimization of Nano Injection Molding Process for Improving Transcription of 100nm-level Pattern (100nm 급 Pattern 전사성 향상을 위한 나노 사출 성형 공정 최적화 연구)

  • Lee, J.S.;Lee, H.G.;Son, S.K.;Lee, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.81-85
    • /
    • 2006
  • In this study, we have been examined nano Injection Molding process which can improve transcription of 100nm-level pattern. We changed the various parameter (temperature of injection mold, clamp force, temperature of nozzle) which can be influence for improving transcription. And we measured and analyzed shapes of 100nm-level pattern by Automic Force Microscope for proving transcription. We made the Blu-ray Disc sample for proving transcription. And we measured HF-Signal and jitter. As a result, when the temperature of mold is more than $120^{\circ}C$ and the clamp force is more than 10 ton, We reached over 95 percent of transcription compared with stamper pattern. And we reached in-spec. value for HF-Signal and Jitter. Then we reached over 95 percent of transcription compared with stamper pattern.

  • PDF

A pitch variation of knee joint sound (슬관절음의 피치변동)

  • Lee, S.O.;Kim, K.S.;Seo, J.H.;Song, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.376-378
    • /
    • 2005
  • In this study, we have evaluated and classified arthritic pathology using the acoustical analysis of knee joint sounds. Six normal subjects and 11 patients with knee problems were enrolled. Patients were divided into the 1st patient group which required an orthopeadic surgery and the 2nd patient group of osteoarthritis. During sitting and standing periods, subjects' active knee flexion and extension were monitored. Fundamental frequency, mean amplitude of pitch, jitter and shimmer were analyzed according to the position and the joint angle. The result showed that the fundamental frequency of the 2nd patient group and standing position was higher than the others, and that the pitch of sounds changed unstably.

  • PDF

Some Clinical Aspects of Dysarthria (마비성 조음장애의 임상적 양상에 관한 고찰)

  • Kim, H.G.;Kim, W.H.;Seo, J.H.;Hong, K.H.;Shin, H.K.;Ko, D.H.
    • Speech Sciences
    • /
    • v.3
    • /
    • pp.38-49
    • /
    • 1998
  • Dysarthrias are a sort of neuromotor disorders because of the weakness of neuromotor controls. They are classified in six types on the basis of Mayo clinic research: flaccid, spastic, ataxic, hypokinetic, hypekinetic and mixed types. Five dysarthria types are investigated in this study. MRI, EMG, neuropathological tests are essential diagnostic processing. Visi-Pitch and Spectrgraphy, CSL are used for assessing dysarthria speech. Maximum phonation time, diadochokinetic rate, Voice Onset Time and substitution rate are the speech evaluation parameters. Maximum phonation time and diadochokinetic rates are the lowest in case of spastic and ataxic dysarthrias. Spastic dysarthria shows the substituted glottalized consonants. However, flaccid, ataxic and hypokinetic dysarthrias show the substituted aspirated consonants. VOT is the longest for hypokinetic dysarthria and the shortest for ataxic dysarthria. Jitter shows higher percentage in comparison with control group. Speech evaluation using experimental phonetic instruments help create on international standardization of speech evaluation for speech disorders.

  • PDF

Design of a 10Gbps CMOS Clock and Data Recovery Circuit (10Gbps CMOS 클록/데이터 복원회로 설계)

  • Cha, C.H.;Shim, H.C.;Jeon, S.H.;Yu, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.197-198
    • /
    • 2007
  • In this paper, a 10Gbps Clock and Data Recovery circuit is designed in $0.18{\mu}m$ CMOS Technology. The circuit incorporates a multiphase LC oscillator, a quarter-rate Bang-Bang phase detector, a Charge Pump and a second order loop filter. The simulation results show that the designed circuit has a peak-to-peak clock jitter of 4.1ps and a peak-to-peak recovered data jitter of 8ps while consuming about 44mW from a 1.8V supply.

  • PDF

Implementation of a High-Quality Audio Collaboration System Over IP Networks (IP 네트워크 기반 고품질 오디오 협업 시스템)

  • Kang, Jin-Ah;Kim, Hong-Kook
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.218-223
    • /
    • 2008
  • In this paper, we implement several methods to improve an audio collaboration system over IP networks, and then evaluate the performance of the implemented methods. In general, speech and audio quality degrades depending on the characteristics of IP networks such as jitter and packet loss. In order to reduce this quality degradation, we propose a lower bit rate audio delivery scheme using the MPEG-2 AAC (Advanced Audio Coding) audio codec in a viewpoint that a packet loss rate could be reduced by a smaller packet size. In addition, iLBC (Internet Low-Bitrate Codec) and the G.711 packet loss concealment algorithm defined by IEFT and ITU-T, respectively, are applied to a audio collaboration system. RAT (Robust-Audio Tool)[7] is used as a baseline platform for the implementation of the proposed methods. It is shown from the implementation that the implemented MPEG-2 AAC audio codec with a bitrate of 256 kbit/s performs as similar as the uncompressed audio quality with a bitrate of 512 kbit/s, and that iLBC and the G.711 packet loss concealment algorithm can improve speech quality when a packet loss rate is 2~10%.

  • PDF

A Study of Acoustic Measurement in Connected Speech with Dysphonia (음성장애 연속구어의 음향학적 분석)

  • Lee, Myoung-Soon
    • Phonetics and Speech Sciences
    • /
    • v.3 no.4
    • /
    • pp.109-115
    • /
    • 2011
  • The purposes of this study were to identify acoustic parameters of connected speech and to contribute to acoustic analysis of dysphonic voice about patient's natural speech voice as well as sustained phonation of vowels. Acoustic parameters of sentences included LTAS (long-term average spectrum) mean and spectral slope over frequence ranges such as 0-4kHz, 0-6kHz, 0-8kHz, 0-12.5kHz as well as HNR. Acoustic parameters of the vowel 'a' included jitter, RAP, shimmer, NHR, and HNR. Based on 'G' of GRBAS for the severity of dysphonia, two experienced raters judged and classified as four groups including controls, mild, moderate and severe dysphonic group. Connected speech was two sentences extracted from 'stroll' passage. Parameters of the vowel and LTAS mean of the sentences were measured by CSL. The spectral slope of the sentences and HNR of the vowel and the sentences were measured by Praat. Data were statistically analyzed by Spearman correlation and Kruskal-Wallis test using SPSS 12.0. The results of this study are as follows: First, jitter, RAP, shimmer and NHR were significantly different between the groups. Second, for several frequencies, LTAS mean and spectral slope of the sentences were significantly different between the groups. Third, the HNR of the sentences were significantly different between the groups. Forth, there was a presence of correlation between HNR and NHR of the vowel and HNR of the sentences. Accordingly, this study concluded that LTAS, spectral slope, and HNR were predictive parameters of connected speech voice for dysphonic voice.

  • PDF

Acoustical analysis of knee sound for diagnosis of articular pathology (관절질환 진단을 위한 슬관절음의 음향학적 분석)

  • Kim, K.S.;Lee, S.O.;Jin, S.C.;Moon, C.H.;Jang, Y.S.;Han, M.S.;Um, E.C.;Kweon, J.B.;Cho, D.H.;Jung, M.S.;Song, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.51-53
    • /
    • 2005
  • Considerable noise is sometimes associated with degeneration of the hee joint surface. Such noise may indicate roughness or softening of the cartilage surfaces, and may be a useful index for early disease. In this study, we have evaluated arthritic pathology using the acoustical analysis of knee joint sounds. During sitting and standing periods, subjects' active knee flexion and extension were monitored. Fundamental frequency, mean amplitude of pitch, jitter and shimmer were analyzed according to the position and the joint angle. The result showed that the fundamental frequency of the 2nd patient group and standing position was higher than the others, and that the pitch of sounds changed unstably. These results suggest that an analysis of knee joint sound might assist non-invasive diagnosis of an articular pathology.

  • PDF

Speech Intelligibility of Alaryngeal Voices and Pre/Post Operative Evaluation of Voice Quality using the Speech Recognition Program(HUVOIS) (음성인식프로그램을 이용한 무후두 음성의 말 명료도와 병적 음성의 수술 전후 개선도 측정)

  • Kim, Han-Su;Choi, Seong-Hee;Kim, Jae-In;Lee, Jae-Yol;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.92-97
    • /
    • 2004
  • Background and Objectives : The purpose of this study was to examine objectively pre and post operative voice quality evaluation and intelligibility of alaryngeal voice using speech recognition program, HUVOIS. Materials and Methods : 2 laryngologists and 1 speech pathologist were evaluated 'G', 'R', 'B' in the GRBAS sclae and speech intelligibility using NTID rating scale from standard paragraph. And also acoustic estimates such as jitter, shimmer, HNR were obtained from Lx Speech Studio. Results : Speech recognition rate was not significantly different between pre and post operation for pathological vocie samples though voice quality(G, B) and acoustic values(Jitter, HNR) were significantly improved after post operation. In Alaryngeal voices, reed type electrolarynx 'Moksori' was the highest both speech intelligibility and speech recognition rate, whereas esophageal speech was the lowest. Coefficient correlation of speech intelligibility and speech recognition rate was found in alaryngeal voices, but not in pathological voices. Conclusion : Current study was not proved speech recognition program, HUVOIS during telephone program was not objective and efficient method for assisting subjective GRBAS scale.

  • PDF