• Title/Summary/Keyword: fused

Search Result 2,151, Processing Time 0.026 seconds

EFFICIENT IHS BASED IMAGE FUSION WITH 'COMPENSATIVE' MATRIX CONSTRUCTED BY SIMULATING THE SCALING PROCESS

  • Nguyen, TienCuong;Kim, Dae-Sung;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.639-642
    • /
    • 2006
  • The intensity-hue-saturation (IHS) technique has become a standard procedure in image analysis. It enhances the colour of highly correlated data. Unfortunately, IHS technique is sensitive to the properties of the analyzed area and usually faces colour distortion problems in the fused process. This paper explores the relationship of colour between before and after the fused process and the change in colour space of images. Subsequently, the fused colours are transformed back into the 'simulative' true colours by the following steps: (1) For each pixel of fused image that match with original pixel (of the coarse spectral resolution image) is transformed back to the true colour of original pixel. (2) The value for interpolating pixels is compensated to preserve the DN ratio between the original pixel and it's vicinity. The 'compensative matrix' is constructed by the DN of fused images and simulation of scaling process. An illustrative example of a Landsat and SPOT fused image also demonstrates the simulative true colour fusion methods.

  • PDF

A case of ilium fused with sacrum in Chinese water deer (Hydropotes inermis) (고라니(Hydropotes inermis) 장골과 천골이 유합된 1례)

  • Kim, Chong-Sup;Koh, Phil-Ok;Cho, Kyu-Woan;Cho, Jae-Hyeon;Won, Chung-Kil
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.465-467
    • /
    • 2005
  • The sacrum fused with ilium in a chinese water deer (Hydropotes inermis) was observed. The sacrum consists of four sacral vertebrae which was fused each other. In the ventral part of the fused pelvis, on the left, there was a 20.19 mm gap at the dorsolateral part of the sacroiliac articular part which is in between the promontory and the cranial border of the first ventral sacral foramen. On the right, there was a 14.34 mm gap at the dorsal part of sacroiliac articulation. In the dorsal view of the fused pelvis, the wing of sacrum and the wing of ilium were fused tightly, so that the boundary of the two bones was not recognizable. The left and right second dorsal sacral foramina and the third dorsal sacral foramen on the left were small. The third dorsal and ventral sacral foramina on the right were not formed.

Efficient method for generating homozygous embryonic stem cells in mice

  • Kim, Bitnara;So, Seongjun;Choi, Jiwan;Kang, Eunju;Lee, Yeonmi
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.37 no.1
    • /
    • pp.48-54
    • /
    • 2022
  • Parthenogenesis is maternally uniparental reproduction through the embryonic development of oocytes without fertilization. Artificial activation of mature oocytes could generate homozygous haploid embryos with the extrusion of the second polar body. However, the haploid embryos showed low embryo development in preimplantation embryos. In this study, we investigated whether the electronic fusion of the haploid embryos could enhance embryo development and ESC establishment in mice. Haploid embryos showed the developmental delay from 4-cell to the blastocyst stage. The haploid blastomeres of the 2-cell stage were fused electronically, resulting in that the fused embryos showed a significantly higher rate of blastocysts compared to non-fused haploid embryos (55% vs. 37%). Further, the embryonic stem cells (ESCs) derived from the fused embryos were confirmed to be diploid. The rate of ESC establishment in fused embryos was significantly higher compared to non-fused ones. Based on the results, we concluded that the electronic fusion of haploid embryos could be efficient to generate homozygous ESCs.

Fracture Strength of Porcelain Fused to Gold Crown & Gold Electroformed Crown (전기도금도재관과 금속도재관의 파절강도)

  • Park, Won-Ju;Lim, Ju-Hwan;Cho, In-Ho;Lim, Heon-Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.101-111
    • /
    • 2002
  • The purpose of this study was to evaluate the fracture strength of porcelain fused to gold crown and gold electroformed crown according to incisal and incisal under 3mm. In this study, 28 gold electroformed crown and 28 porcelain fused to gold crown were fabricated. Fracture strength testing was carried out using an Instron 8871(Instron Corporation, U.S.A) at a cross head speed of 5mm/min. All of the measurements were statistically analyzed by Independent t-testing, and k-s testing. Statistical significance was set in advance at the probability level of less than 0.05. All measurements were analized with Windows $SPSS^{(R)}$ Version 10.0 software for the personal computer. The results of this study were as follows; 1. Comparison by location (1) A compared fracture strength of incisal and incisal under 3 mm, there was statistical significant difference between gold electro -formed crown and porcelain fused to gold crown (p<0.05). 2. Comparison by loading (1) When compared fracture strength of incisal, there was no significant difference between gold electroformed crown ($619.90{\pm}53.54N$)and porcelain fused to gold crown($674.68{\pm}87.42N$). (2) When compared fracture strength of incisal under 3 mm, there was significant difference between gold electroformed crown($688.29{\pm}14.88N$) and porcelain fused to gold crown($1931.81{\pm}29.64N$) (p<0.05). 3. Mode of fracture When compared of fracture mode, gold electroformed crown showed mode of fracture and fracture line reaching coping region and porcelain fused to gold crown showed only in porcelain region.

A COMPARISON OF FRACTURE STRENGTHS OF PORCELAIN-FUSED-TO-TITANIUM CROWN AMONG TITANIUM SURFACE COATING TREATMENTS (타이타늄 표면 코팅 처리에 따른 타이타늄도재관의 파절강도 비교)

  • Kim, Ji-Hye;Park, Sang-Won;Vang, Mong-Sook;Yang, Hong-So;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Kyung-Ku
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.203-215
    • /
    • 2007
  • Statement of problem: Titanium and its alloy, with their excellent bio-compatibility and above average resistance to corrosion, have been widely used in the field of dentistry. However, the excessive oxidization of titanium which occurs during the process of firing on porcelain makes the bonding of titanium and porcelain more difficult than that of the conventional metal-porcelain bonding. To solve this problem related to titanium-porcelain bonding, several methods which modify the surfaces, coat the surfaces of titanium with various pure metals and ceramics, to enable the porcelain adhesive by limiting the diffusion of oxygen and forming the adhesive oxides surfaces, have been investigated. Purpose: The purpose of this study was to know whether the titanium-porcelain bonding strength could be enhanced by treating the titanium surface with gold and TiN followed by fabrication of clinically applicable porcelain-fused-to-titanium crown Material and method: The porcelain-fused-to-titanium crown was fabricated after sandblasting the surface of the casting titanium coping with $Al_2O_3$ and treating the surface with gold and TiN coating followed by condensation and firing of ultra-low fusing porcelain. To compare with porcelain-fused-to-titanium crowns, porcelain-fused-to-gold crowns were fabricated and used as control groups. The bonding strengths of porcelain-fused-to-gold crowns and porcelain-fused-totitanium crowns were set for comparison when the porcelain was fractured on purpose to get the experimental value of fracture strength. Then, the surface were examined by SEM and each fracturing pattern were compared with each other Result:Those results are as follows. 1. The highest value of fracture strength of porcelain-fused-to-titanium crowns was in the order of group with gold coating, group with TiN coating, group with $Al_2O_3$ sandblasting. No statistically significant difference was found among the three (P>.05). 2. The porcelain-fused-to-gold crowns showed the highest value in bonding strength. The bonding strength of crowns porcelain-fused-to-titanium crowns of rest groups showed bonding strength reaching only 85%-94% of that of PFG, though simple comparision seemed unacceptable due to the difference in materials used. 3. The fracturing patterns between metal and porcelain showed mixed type of failure behavior including cohesive failure and adhesive failure as a similar patterns by examination with the naked eye and SEM. But porcelain-fused-to-gold crowns showed high incidence of adhesive failure and porcelain-fused-to-titanium crowns showed high incidence of cohesive failure. Conclusion: Above results proved that when fabricating porcelain-fused-to-titanium crowns, treating casting titanium surface with gold or TiN was able to enhance the bonding strength between titanium and porcelain. Mean value of masticatory force was found to showed clinically acceptable values in porcelain bonding strength in all three groups. However, more experimental studies and evaluations should be done in order to get better porcelain bonding strength and various surface coating methods that can be applied on titanium surface with ease.

Maturation Induction of Mouse Immature Oocytes by Fusion (생쥐 미성숙 난자의 융합에 의한 성숙 유도)

  • 김해권;공희숙;이경광;조완규
    • The Korean Journal of Zoology
    • /
    • v.30 no.1
    • /
    • pp.89-98
    • /
    • 1987
  • The research of fused oocytes was conducted to investigate the in vitro mejotic maturation of immature oocytes (GV oocytes) fused with oocytes in germinal vesicle breakdown (GVBD oocytes) in the presence of dbcAMP which is known as one of the strong inhibitors to GVBD. The immature oocytes fused together as well as those fused with GVBD oocytes proceeded to GVBD in 3 hr culture in plain medium. But in the medium containing dbcAMP (100$\mu$g/ml), the immature oocytes fused together did not show any GVBD and thus the fusion itself could not affect the inhibitory activity of dbcAMP. However, all of the immature oocytes fused with GVBD oocytes underwent GVBD in 3 hr culture despite of the presence of dbcAMP. When the culture was extended to 20 hr, nearly all of the immature oocytes fused together were still arrested at the GV stage in the presence of dbcAMP. But most of the fused oocytes which had shown GVBD during 3 hr culture developed to metaphase II stage extruding one or two polar bodies regardless of the presence of dbcAMP. In this experiment, it was found that two sets of the metaphase chromosomes were somewhat concomitant with a pair of the polar bodies in the fused egg. Upon the results of the present studies, it is assumed that there may be a maturation promoting factor(s) in the cytoplasm of the GVBD occytes, and this factor(s) possibly nullifies the function of dbcAMP.

  • PDF

Evaluation of Color Change according to Process Step of Fused Porcelain to SLM Method (치과용 레이저 선택가공 금속체의 도재 소성단계에 따른 색조변화 관찰)

  • Kim, Chi-Young;Chung, In-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.12
    • /
    • pp.236-242
    • /
    • 2010
  • The porcelain fused metal was made through the progressive fused process of porcelain on substructure of metal material. The substructure was made using novel SLM method. The objective of this study was to observe the color change of porcelain using spectrophotometer equipment according to porcelain fused step and production methods after conducting the process of casting and SLM method of the substructure. The color change by step was indicated that fused opaque porcelain groups(CN1, CC1, CT1, SC1, ST1) had color difference(${\Delta}E$=30) by comparison with fused body porcelain groups(CN2, CC2, CT2, SC2, ST2) and fused glazing porcelain groups(CN3, CC3, CT3, SC3, ST3) (p<0.05). and there was no color difference between the substrates(CN, CC, CT) made by the casting method and the substrates(SC, ST) made by the SLM method. so, the color change was expressed by fused change of porcelain, and this study showed that the color of porcelain fused metal made by the SLM method can be applied clinical trials.

A Study on Metal-Porcelain Fusing Layer in Porcelain Fused to High Gold Alloy (도재소부용 고금함유금합금의 연구 - 도재 결합층을 중심으로 -)

  • Lee, Kee-Dae;Kwak, Dong-Ju
    • Journal of Technologic Dentistry
    • /
    • v.31 no.3
    • /
    • pp.15-20
    • /
    • 2009
  • The success of the porcelain fused to gold alloy restoration depends not only on the choice of materials but to a larger degree on the technical skills. The porcelain fused to metal(PFM) alloys containing gold are commonly use for dental purposes in dental laboratory. The gold-colored alloys contain primarily gold, platinum, palladium, and silver, with minimum amounts of such metals as tin, iridium, or titanium. The purpose of this study is on the metal-porcelain fusing layer in porcelain fused to high gold alloy Principal results are as follows. The hardness number(Hv) of PFG is respectively $140.2{\pm}12.6$ in as-casted, $164.3{\pm}14.3$ in heat-treated, $186.6{\pm}20.4$ in fired-treated. The formation of the fusing(intermediate) layer caused by components fusing the interface of porcelain and gold alloy. The main components of the fusing(intermediate) layer are Na, Al, Si, K, Zn, Zr and Ce. The intermediate layer formed by the 2nd firing is more larger than the intermediate layer formed by the 1st firing.

  • PDF

Detection of multiple change points using penalized least square methods: a comparative study between ℓ0 and ℓ1 penalty (벌점-최소제곱법을 이용한 다중 변화점 탐색)

  • Son, Won;Lim, Johan;Yu, Donghyeon
    • The Korean Journal of Applied Statistics
    • /
    • v.29 no.6
    • /
    • pp.1147-1154
    • /
    • 2016
  • In this paper, we numerically compare two penalized least square methods, the ${\ell}_0$-penalized method and the fused lasso regression (FLR, ${\ell}_1$ penalization), in finding multiple change points of a signal. We find that the ${\ell}_0$-penalized method performs better than the FLR, which produces many false detections in some cases as the theory tells. In addition, the computation of ${\ell}_0$-penalized method relies on dynamic programming and is as efficient as the FLR.

A comparative study on the fracture strength of esthetic porcelain crowns (심미도재관의 파절 강도 비교 연구)

  • Kim, Eun-Ha;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.79-85
    • /
    • 2007
  • In this study, We tried to find out the fracture strength of zirconia coping all ceramic crown and collarless porcelain fused gold alloy crown as the compared group. Each of the collarless porcelain fused gold crown and zirconia all ceramic crown has been produced specimen 10 each. And after pasting them on the steel jig, it had load given at porcelain incisal edge by 130$^{\circ}$ and measured fracture strength by Universal Testing Machine and then We have results from that. 1. The average value of fracture strength suggested 950.49 N at collarless porcelain fused gold alloy crown, 656.81 N at zirconia coping all ceramic crown. 2. Fractured pattern showed that the whole of labial part was exposed in collarless porcelain fused gold crown, but porcelain of margin part did not show fracture in advance. In the practice, the concern that collarless might cause fracture strength to be weaken does not matter, we concluded zirconia all ceramic crown made fracture that only a part of labial porcelain was fractured. The combination of zirconia all ceramic crown and turned out to be excellent.

  • PDF