• 제목/요약/키워드: furnace design

검색결과 346건 처리시간 0.027초

릴레이 회로의 확장된 마크흐름선도 변환 (The Relay Circuits Translation to EMFGs)

  • 여정모;백형구
    • 제어로봇시스템학회논문지
    • /
    • 제9권11호
    • /
    • pp.952-957
    • /
    • 2003
  • We propose how to translate relay circuits to the EMFGs(Extended Mark Flow Graphs) formally and analyze the original one by using the mark flow of it. Firstly, the concepts of the output condition, the output-on condition and the output-off condition are introduced in the relay circuits. These can be used to find the structure and the operation of respective relay outputs but the sequential operations of them cannot be obtained from these. Secondly, a relay circuit is translated to the corresponding EMFG as the all output-on conditions and all output-off conditions of it are translated to EMFGs. For the adequate translation, the condition arc and the concepts of the generation transition and the degeneration transition are introduced, and the duality for the simplification of the result. Thirdly, we analyze the operation of the original circuit by analyzing the mark flow of the resulting EMFG. We can achieve easy and fast analysis based on the EMFG's operation algorithm. Finally, we apply these to the relay circuit for an electric furnace and analyze its operation with the mark flow of the resulting EMFG. The formal translation from relay circuits to EMFGs makes the analysis easy so that these results can be used to design, modelling, the fault detection and the maintenance.

강원 영동지역의 관광철 폐기물 및 발열량 특성 (Characteristics of Municipal Solid Wastes and Heating Value in Tourist Season of the eastern side of Gangwondo)

  • 이해승;최용범
    • 환경위생공학
    • /
    • 제21권1호
    • /
    • pp.66-75
    • /
    • 2006
  • When we looked at the seasonal food dregs of the eastern side of gangwondo, gangneung city's summer and winter food dregs showed 25.9 and 25.8% respectively due to the presence of beach areas and ski resorts. Sokcho city showed 28.12% in summer and yangyang gun's summer food dregs showed 40.2%. Yangyang gun's august food dregs showed 2.7 times larger than annual average amount. Outlook density showed regional characteristics. Data showed that food dregs' amount rate has been reduced gradually from 2005 because of the prohibition of direct filling up. As a result of compositions analysis, the eastern side of gangwondo's water fraction of living dregs were lower than that of chuncheon city where is located at the gangwondo's inland area. chuncheon city's data showed residential areas 53.5%, community areas 56.8% and commercial areas 55.6%. These discrepancies caused by the characteristics of dregs discharge type and climate. The caloric value of dregs has been increased incrementally after the ban of food dregs' direct filling up. Therefore, heating value of the dregs exceeds the existing furnace design spec and it can cause high caloric value problems, so we need additional research to solve these problems.

유동상 반응로 조건에서 목재와 RDF 부분 산화의 영향 (Effect of Partial Oxidation of Wood and RDF in a Fluidized Bed)

  • 김태현;최상민
    • 한국연소학회지
    • /
    • 제13권2호
    • /
    • pp.23-32
    • /
    • 2008
  • Gasification characteristics in the fluidized bed reactor are essential for the design of a gasification furnace to optimize the operation condition. Moisture content of the solid fuel is one of the important factors to influence directly the gasification characteristics. So it is necessary to investigate the effect of moisture content of solid fuel in partial oxidation condition. Gasification characteristics are investigated with results from thermogravimetric analyzer and lab-scale fluidized bed reactor for wood and RDF samples along with changing moisture contents. Additionally lab-scale fluidized bed reactor was run continuously and gas concentrations at the exit were measured. It is observed that the rate of reaction in partial oxidation condition is between the results from the combustion environment and from the inert condition. Moisture content in a particle slows down the heating rate of a particle. So, reaction is delayed by the moisture content. However, RDF samples those are easy to break-up don't show the effect of moisture content. The result of continuous operation condition shows that proper moisture content promotes gasification because steam from the particles helps gasification of the solid fuel. A simulation to predict the syn-gas composition was conducted by the Aspen Plus process simulator. The cold gas efficiency of the experiment was compared with results from the simulation.

  • PDF

혼화재 종류 변화에 따른 저온조건하 콘크리트의 초기강도 발현 특성 (Strength Development of the Concrete at Early Age subjected to Low Temperature depending on Admixture Types)

  • 한민철
    • 한국건축시공학회지
    • /
    • 제7권4호
    • /
    • pp.145-151
    • /
    • 2007
  • In this paper, tests are carried out in order to investigate the strength development of concrete under various binder types, W/B and curing temperature ranged from $5{\sim}20^{\circ}C$. Fly ash and blast furnace slag were incorporated by as much as 30%, respectively. Strength development of concrete are estimated using Logistic model and strength ratio of concrete at 28days to that at early age are also investigated. According to experimental results, it is found that good agreements are obtained between measured values and calculated ones using logistic model below $20^{\circ}C$. Strength ratio of concrete at 28days to that at early age increases in case W/B decreases and curing temperature increases. Tables and graphs for strength ratio of concrete are provided in this paper. It is capable of obtaining and predicting the periods to attain design strength by considering increment factor of strength easily with the table and graphs presented in this paper. This paper presents the reference data to decide removal time of form, time to reach target strength and strength inspection of remicon whether the test specimens meet the specified criteria of compressive strength. Multi regression models with respect to the relationship between 7days compressive strength and 28 days compressive strength depending on W/B and admixture types are presented.

질화탄탈 박막형 스트레인 게이지의 제작과 특성 (Fabrication and Characteristics of Tantalum Nitride Thin-Film Strain Gauges)

  • 정귀상;우형순;김순철;홍대선
    • 센서학회지
    • /
    • 제13권4호
    • /
    • pp.303-308
    • /
    • 2004
  • This paper descibes on the characteristics of Ta-N(tantalum nitride) ceramic thin-film strain gauges which were deposited on Si substrates by DC reactive magnetron sputtering in an argon-nitrogen atmosphere (Ar-$(4{\sim}16%)N_{2}$) for high-temperature applications. These films were annealed in $2{\times}10^{-6}$ Torr vacuum furnace at the range of $500{\sim}1000^{\circ}C$. Optimum deposition atmosphere and annealing temperature were determined at $900^{\circ}C$ for 1 hr. in 8% $N_{2}$ gas flow ratio. Under optimum formation conditions, the Ta-N thin-film for strain gauges was obtained a high-resistivity of $768.93{\mu}{\Omega}{\cdot}cm$, a low temperature coefficient of resistance (TCR) of -84 ppm/$^{\circ}C$ and a good longitudinal gauge factor (GF) of 4.12.

1MWth 실험연소로를 이용한 석탄의 연소특성 연구 (Study on Coal Combustion Characteristics with 1MWth Test Facility)

  • 장길홍;장인갑;정석용
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1464-1472
    • /
    • 1999
  • Design and operation of $1MW_{th}$ pulverized coal combustion testing facility are described. Also the influence of air staging on NOx emission and burnout of coal flames was investigated in this facility. The test facility consisted of coal feeding system, firing system and flue gas treatment system. A top-fired externally air staging burner was adopted in order to avoid influence of gravity on the coal particles and for easy maintenance. Distribution of temperature and chemical species concentration of coal flames could be measured in vertical pass of furnace. Main fuel was pulverized (83.4% less than $80{\mu}m$) Australian high bituminous coal. From variety of test conditions, overall excess air ratio was selected at 1.2(20% excess air). Tho study showed that increasing the staged air resulted in lower NOx omission, and it was suggested to be more than 40% of the total combustion air for the substantial NOx reduction. Sufficient burnout was not achievable when NOx emission was less than 500ppm. Also, the amount of core air did not influence tho NOx reduction.

침식 해석을 이용한 월 블로워 노즐의 성능 예측 (Performance Evaluation of Wall Blower Nozzle using Erosion Analysis)

  • 백재호;장일광;장용훈
    • Tribology and Lubricants
    • /
    • 제34권5호
    • /
    • pp.175-182
    • /
    • 2018
  • Accumulation of coal ash at the boiler wall reduces combustion and fuel efficiency. The design of a wall blower is important to effectively remove coal ash. We present numerical results for the removal of coal ash from boiler walls of domestic coal-fired power plants, associated with the computational fluid dynamics for the flow from spray nozzle to boiler wall. The numerical model simulates an erosion process in which the multiphase fluid comprising saturated vapor and fluid water is sprayed from the nozzle, and the water particles impact the boiler wall. We adopt the Finnie erosion model for water particles. We obtain the erosion rate density as a function of nozzle angle and its injection angle. As excessive coal ash removal usually induces damage to the boiler wall, the removal operation typically focuses on a large area with uniform depth rather than the maximum removal of coal ash at a specific location. In order to estimate the removal performance of the wall blower nozzle considering several functionality and reliability factors, we evaluate the optimal injection and nozzle angles with respect to the biggest cumulative and highest erosion rates, as well as the widest range and lowest standard deviation of the erosion rate distribution.

석탄화력발전소 보일러 연료제어 알고리즘과 분산제어시스템의 개발 (The Development of Boiler Fuel Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;이흥호
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.36-44
    • /
    • 2013
  • This paper is written for the development and application of boiler fuel control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. Fuel control algorithm has the upper algorithm and it is boiler master control algorithm that controls the fuel, feed water, air by generation output demand. Generation output demand by power load influences fuel control. Because fuel can not be supplied fast to the furnace of boiler, fuel control algorithm was designed adequately to control the steam temperature and to prevent the explosion of boiler. This control algorithms were coded to the control programs of distributed control systems which were developed domestically for the first time. Simulator for coal-fired power plant was used in the test step. After all of distributed control systems were connected to the simulator, the tests of the actual power plant were performed successfully. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.

단결정 실리콘 잉곳 결정성장 속도에 따른 고-액 경계면 형성 및 Defect 최적화 (Melt-Crystal Interface Shape Formation by Crystal Growth Rate and Defect Optimization in Single Crystal Silicon Ingot)

  • 전혜준;박주홍;블라디미르 아르테미예프;정재학
    • Current Photovoltaic Research
    • /
    • 제8권1호
    • /
    • pp.17-26
    • /
    • 2020
  • It is clear that monocrystalline Silicon (Si) ingots are the key raw material for semiconductors devices. In the present industries markets, most of monocrystalline Silicon (Si) ingots are made by Czochralski Process due to their advantages with low production cost and the big crystal diameters in comparison with other manufacturing process such as Float-Zone technique. However, the disadvantage of Czochralski Process is the presence of impurities such as oxygen or carbon from the quartz and graphite crucible which later will resulted in defects and then lowering the efficiency of Si wafer. The heat transfer plays an important role in the formation of Si ingots. However, the heat transfer generates convection in Si molten state which induces the defects in Si crystal. In this study, a crystal growth simulation software was used to optimize the Si crystal growth process. The furnace and system design were modified. The results showed the melt-crystal interface shape can affect the Si crystal growth rate and defect points. In this study, the defect points and desired interface shape were controlled by specific crystal growth rate condition.

투수성 폴리머 블록 포장에 의한 우수 유출 저감 효과에 관한 실험적 연구 (Experimental Study on Rainfall Runoff Reduction Effects by Permeable Polymer Block Pavement)

  • 성찬용;김영익
    • 한국농공학회논문집
    • /
    • 제54권2호
    • /
    • pp.157-166
    • /
    • 2012
  • Most of the roads are paved with impermeable materials such as asphalt concrete and cement concrete, and in the event of heavy rainfall, rainwater directly flows into river through a drainage hole on the pavement surface. This large quantity of rainwater directly spilled into the river frequently leads to the flooding of urban streams, damaging lowlands and the lower reaches of a river. In recent years there has been a great deal of ongoing research concerning water permeability and drainage in pavements. Accordingly, in this research, a porous polymer concrete was developed for permeable pavement by using unsaturated polyester resin as a binder, recycled aggregate as coarse aggregate, fly ash and blast furnace slag as filler, and its physical and mechanical properties were investigated. Also, 3 types of permeable polymer block by optimum mix design were developed and rainfall runoff reduction effects by permeability pavement using permeable polymer block were analyzed based on hydraulic experimental model. The infiltration volume, infiltration ratio, runoff initial time and runoff volume in permeability pavement with permeable polymer block of $300{\times}300{\times}80$ mm were evaluated for 50, 100 and 200mm/hr rainfall intensity.