• Title/Summary/Keyword: fundamental frequency component

Search Result 113, Processing Time 0.02 seconds

Phasor Estimation Algorithm Based on the Least Square Technique during CT Saturation

  • Lee, Dong-Gyu;Kang, Sang-Hee;Nam, Soon-Ryul
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.459-465
    • /
    • 2011
  • A phasor estimation algorithm based on the least square curve fitting technique for the distorted secondary current due to current transformer (CT) saturation is proposed. The mathematical form of the secondary current during CT saturation is represented as the scaled primary current with magnetizing current. The information on the scaled primary current is estimated using the least square technique, with the measured secondary current in the saturated section. The proposed method can estimate the phasor of a fundamental frequency component during the saturated period. The performance of the algorithm is validated under various fault and CT conditions using a C400 CT model. A series of performance evaluations shows that the proposed phasor estimation algorithm can estimate the phasor of the fundamental frequency component with high accuracy, regardless of fault conditions and CT characteristics.

Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators (열화된 고분자애자의 카올린 오손에따른 표면방전특성)

  • Park, Jae-Jun;Ga, Pyung-Hyun;Seo, Ui-Won;Jung, Myeong-Yeon;Song, Il-Kwen;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

Control of Electrically Excited Synchronous Motors with a Low Switching Frequency

  • Yuan, Qing-Qing;Wu, Xiao-Jie;Dai, Peng;Fu, Xiao
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.615-622
    • /
    • 2012
  • The switching frequency of the power electronic devices used in large synchronous motor drives is usually kept low (less than 1 kHz) to reduce the switching losses and to improve the converter power capability. However, this results in a couple of problems, e.g. an increase in the harmonic components of the stator current, and an undesired cross-coupling between the magnetization current component ($i_m$) and the torque component ($i_t$). In this paper, a novel complex matrix model of electrically excited synchronous motors (EESM) was established with a new control scheme for coping with the low switching frequency issues. First, a hybrid observer was proposed to identify the instantaneous fundamental component of the stator current, which results in an obvious reduction of both the total harmonic distortion (THD) and the low order harmonics. Then, a novel complex current controller was designed to realize the decoupling between $i_m$ and $i_t$. Simulation and experimental results verify the effectiveness of this novel control system for EESM drives.

THD Analysis of Output Current for Active Frequency Drift Method in Anti-islanding (능동적 주파수 변환기법의 출력전류 고조파 왜형율 분석)

  • Lee, Ki-Ok;Choi, Ju-Yeop;Choy, Ick;Yu, Gwon-Jong;An, Jin-Ung
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.7-12
    • /
    • 2010
  • As many grid-connected photovoltaic power conditioning systems (PVPCS)are installed in many residential areas simultaneously, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. In this paper, active frequency drift (AFD) method, one of the anti-islanding methods which is analyzed by current magnitude compensation and calculation of the fundamental component. Both harmonic component and RMS value of the output current for THD analysis are provided and verified by simulation.

A Design of Frequency Multipliers Using λ/4 Open Composite Right/Left Handed Stub and Left Handed Transmission Line (λ/4 개방형 CRLH 스터브와 LH 전송 선로를 이용한 주파수 체배기 설계)

  • Seo, Su-Jin;Park, Sang-Keun;Choi, Heung-Jae;Jeong, Yong-Chae;Lim, Jong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1271-1278
    • /
    • 2007
  • A novel frequency multiplier using composite right/left-handed transmission line is proposed. The left-handed transmission line in the proposed frequency multiplier suppresses the fundamental component($f_0$), while the composite right/left-handed ${\lambda}/4$ open stub diminishes unwanted harmonics. Due to the combination of the left-handed transmission line and composite right/left-handed ${\lambda}/4$ open stub, the only desirable multiplied frequency component such as 3 $f_0$ and 4 $f_0$ are obtained at the output port excellently. For the example of the proposed design, frequency multipliers are designed at 1 GHz of $f_0$ and measured. The measured output power of 3 $f_0$ and 4 $f_0$ is -5.67 dBm and -6.43 dBm, respectively, when the fundamental input power was 0 dBm.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

AM-FM Decomposition and Estimation of Instantaneous Frequency and Instantaneous Amplitude of Speech Signals for Natural Human-robot Interaction (자연스런 인간-로봇 상호작용을 위한 음성 신호의 AM-FM 성분 분해 및 순간 주파수와 순간 진폭의 추정에 관한 연구)

  • Lee, He-Young
    • Speech Sciences
    • /
    • v.12 no.4
    • /
    • pp.53-70
    • /
    • 2005
  • A Vowel of speech signals are multicomponent signals composed of AM-FM components whose instantaneous frequency and instantaneous amplitude are time-varying. The changes of emotion states cause the variation of the instantaneous frequencies and the instantaneous amplitudes of AM-FM components. Therefore, it is important to estimate exactly the instantaneous frequencies and the instantaneous amplitudes of AM-FM components for the extraction of key information representing emotion states and changes in speech signals. In tills paper, firstly a method decomposing speech signals into AM - FM components is addressed. Secondly, the fundamental frequency of vowel sound is estimated by the simple method based on the spectrogram. The estimate of the fundamental frequency is used for decomposing speech signals into AM-FM components. Thirdly, an estimation method is suggested for separation of the instantaneous frequencies and the instantaneous amplitudes of the decomposed AM - FM components, based on Hilbert transform and the demodulation property of the extended Fourier transform. The estimates of the instantaneous frequencies and the instantaneous amplitudes can be used for modification of the spectral distribution and smooth connection of two words in the speech synthesis systems based on a corpus.

  • PDF

Estimation Technique of Frequency using FIR Filter in the Power System (FIR 필터를 이용한 전력계통의 주파수 추정기법)

  • 남시복;박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Characteristics of pressure Propagation According to Frequency Changes in a Hydraulic Pipeline (유압관로의 주파수변화 따른 압력전파특성)

  • 유영태;나기대;김지환
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.2
    • /
    • pp.71-79
    • /
    • 2002
  • In this paper, an oil hydraulic pipeline is terminated by both rotary sinusoidal flow generator at upstream oriffice at down stream. The pulsating pressure wave from generated by the rotary sinusoidal flow generator, is measured by using sensor. In the analysis of this paper, a component of the fundamental frequency is obtained by using Laplace transformation.. The experimental and analytical results make clear that (1) viscosity is significant role in hydraulic pipe. (2) When pulsating frequency is matched with the natural frequency, resonance frequency occured periodically. According to the study proposed here, dynamic pressure in a circular oil pipe is expressed in propagation of pressure wave with respect to frequency and Bessel function. The resonance at oil temperature $20^{\circ}$$0^{\circ}C$ in this study. The abrupt change of gain value is due to effect of resonance frequency. The results of experiment are compared with the calculated results, and agreement of both results is fairly good.

Over Current Protection Schemes for Active Filters with Series Compensators

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.134-145
    • /
    • 2004
  • This paper presents and analyses protection schemes for a series active compensator, which consists of a Unified Power Quality Conditioner (UPQC) or a hybrid active power filter. The proposed series active compensator operates as a high impedance "k(D)" for the fundamental components of the power frequency during over current conditions in the distribution system. Two control strategies are proposed in this paper. The first strategy detects the fundamental source current using the p-q theory. The second strategy detects the fundamental component of the load current in the Synchronous Reference Frame (SRF). When over currents occur in the power distribution system momentarily, the proposed schemes protect the series active compensator without the need for additional protection circuits, and achieves excellent transient response. The validity of the proposed protection schemes is investigated through simulation and compared with experimental results using a hybrid active power filter systems.