• Title/Summary/Keyword: full bridge inverter

Search Result 295, Processing Time 0.023 seconds

Development of TIG-Welder DC-DC Converter Based on Fuel Cell Stack (연료전지로 구동되는 TIG-용접기용 DC-DC 컨버터 개발)

  • Min, Myung-Sik;Park, Sang-Hoon;Jeon, Byum-Soo;Won, Chung-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.48-56
    • /
    • 2009
  • This paper presents the power conversion system for TIG-welder using the fuel cell stack Generally, power supply for TIG-welder uses the front-ended diode bridge rectifier by common AC power source. In this case, power supply of TIG-welder increases in volume because of using bulky capacitor and diode-rectifier. Also, input current includes ripple and harmonics. Moreover, TIG-welder will be demand the power supply with lightweight and easy movement in the areas like as the islands and mountainous areas or the special environment are not use common AC power source. Thus, input power of the power conversion system for TIG-welder is used PEMFC(Polymer Electrolyte Membrane Fuel Cell), and the power conversion system is comprised of full-bridge converter with function of boost converter and inverter welding source, in this paper. The proposed power conversion system which is power supply for TIG-welder was verified by computer simulations and experiments.

Study on Change of Poly ADP Ribose Polymerase in the Rat with Thrombotic Stroke by Full Wave Cockroft Walton method's Transcranial Magnetic Stimulation

  • Kim, Whi-Young;Kim, Jun-Hyoung
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • This study examined the relationships between protein expression and Poly ADP ribose polymerase in brain cell death in brains damaged by thrombotic stroke and treated with the Full Wave- Cockroft Walton (FWCW) method of Transcranial Magnetic Stimulation (TMS). The two-way switching element for TMS drove a half-bridge inverter of the current resonance of direct current voltage (+) and direct current voltage (-), and the experiment was conducted by stimulating the mice with thrombotic stroke through a range of pulses. Thrombotic stroke was caused of ligation of the common carotid artery of male SD mice, and blood reperfusion was conducted five minutes later. Protein expression was examined in immune reaction cells, which reacted to an antibody to Poly ADP ribose polymerase in the cerebrum cells, and western blotting. Observations of the PARP changes after thrombotic stroke showed that the number of Poly ADP ribose polymerase reactions were significantly lower (p < 0.05) in the group treated with TMS of the FWCW than the group with thrombotic stroke 24 hours after its onset. The application of FWCW-TMS helped prevent the necrosis of nerve cells and might prevent the brain damage that occurs as a result of thrombotic stroke, and improve the function recovery and disorder of brain cells.

A Study on characteristic of a double resonant type high frequency inverter using Phase-Shift (Phase-Shift를 이용한 복공진형 고주파 인버터의 특성에 관한 연구)

  • 조규판;김종해;남승식;김동희;노채균;배영호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.109-117
    • /
    • 2000
  • A full bridge type double resonant high frequency resonant inverter to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one and this paper also realize the output control of independence irrespective of the switching frequency using Phase-shift. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters, such as switching frequency, the variation of phase angle ($\phi$) of Phase-shift.

  • PDF

Implementation of Zero-Ripple Line Current Induction Cooker using Class-D Current-Source Resonant Inverter with Parallel-Load Network Parameters under Large-Signal Excitation

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1251-1264
    • /
    • 2018
  • The systematic and effective design method of a Class-D current-source resonant inverter for use in an induction cooker with zero-ripple line current is presented. The design procedure is based on the principle of the Class-D current-source resonant inverter with a simplified load network model that is a parallel equivalent circuit. An induction load characterization is obtained from a large-signal excitation test-bench based on parallel load network, which is the key to an accurate design for the induction cooker system. Accordingly, the proposed scheme provides a systematic, precise, and feasible solution than the existing design method based on series-parallel load network under low-signal excitation. Moreover, a zero-ripple condition of utility-line input current is naturally preserved without any extra circuit or control. Meanwhile, a differential-mode input electromagnetic interference (EMI) filter can be eliminated, high power quality in utility-line can be obtained, and a standard-recovery diode of bridge-rectifier can be employed. The step-by-step design procedure explained with design example. The devices stress and power loss analysis of induction cooker with a parallel load network under large-signal excitation are described. A 2,500-W laboratory prototype was developed for $220-V_{rms}/50-Hz$ utility-line to verify the theoretical analysis. An efficiency of the prototype is 96% at full load.

A Study of the Inverter Optimization Design for EEFL BLU (EEFL BLU 구동용 인버터 최적화 설계에 대한 연구)

  • Kim, S.B.;Lee, S.H.;Kang, J.G.;Cho, M.R.;Shin, S.W.;Lee, S.H.;Hwang, M.K.;Yang, S.Y.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.241-245
    • /
    • 2006
  • EEFL(External Electrode Fluorescent Lamp) for LCD displays are analyzed on electrical and optical characteristics by various electrode length. The electrodes of EEFL are coated at the outside of the glass tube. Brightness and efficiency of the EEFL are affected on lamp impedance characteristic. So, the experimental models are proposed for analysis and measurements of the brightness and efficiency of the lamps according to the electrode length. The sample of LCD backlight unit is used for these experiments, EEFL arrayed BLU of 32' for commercial TV display. The parameters of the experiments were quantised for simple result reading as the length of electrodes as 15, 23 and 30 mm. The inverter was designed and manufactured in the laboratory as the Full-Bridge switching inverter. The feature of the output were measured on voltages about 1000 - 1400V at the currents of 11 - 29 mA and the brightness $15,000\;cd/m^2-40,000\;cd/m^2$. The experiments have shown that the brightness are increased by increasing of the electrode lengths which have the lamp currents increased. But at an certain conditions, the brightness and efficiency were decreased because of unmatched between the inverter output and lamp impedance. The optimum applications of the EEFL BLU of 32' in this experiments have been shown to choose the parameters for driving frequencies of 100 kHz - 150 kHz, the brightness of $18,000-19,000\;cd/m^2$ and efficiencies of 40 - 45 lm/w.

  • PDF

PWM Inverter System Control for Flywheel Energy Storage System using PDFF(Pseudo-Derivative Control with Feedforward Gain) Algorithm (PDFF 기법을 적용한 플라이휠 에너지 저장장치용 PWM 인버터 시스템 제어)

  • Park, Jong-Chan;Jeong, Byung-Hwan;Choi, Hee-Ryong;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.267-275
    • /
    • 2007
  • This paper presents about energy input and output modeling for a flywheel energy storage system that can store and supply mechanical energy, which is emerging as one of clean energy sources, and the analysis and control of a PWM inverter system. Moreover, this paper describes flywheel's characteristics related to variations of mechanical and electrical parameters like as voltage and current versus speed characteristics formed as numerical formula and thus simulate behaviour-status of flywheel energy. Also for comparison and analysis between PI control and PDFF control, the modeling, design and analysis to the single-phase full bridge inverter with double loop feedback control is accomplished through numerical description and simulation. Finally, under load condition 0.1[pu], 1[pu]. it is validated that harmonic characteristics for voltage and current wave is controlled within 5% below even dynamics condition.

A Study on the development of Explosion-proof type's the terminal box of the ventilator with the control of wind volume and operating time (풍량 및 운전시간 제어 방폭 배풍기 인버터 단자함 개발에 관한 연구)

  • Yoo, DongJoo
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.187-192
    • /
    • 2018
  • This thesis is about the study of inverter terminal boxes in a explosion proof type exhaust fan that can control wind volume and operating time. In Korea, there is no ventilator to adjust the amount of wind and operating time when working in poor conditions. The purpose of the project is to create a explosion terminal box that can control the operating time and wind speed of a suitable explosion ventilator in hazardous environments. The two explosion-proof switches allow the operation time to be driven 1 hour, 3 hours and continuous time, and the speed of the induction motor rotation was set in 3 stages at 2000 rpm, 2600 rpm and 3000 rpm to control the volume. The tested motor used a half-horsepower barrier three-phase induction motor and a full-bridge inverter to set the desired flow rate and operating time.

Parallel Operation of Microgrid Inverters Based on Adaptive Sliding-Mode and Wireless Load-Sharing Controls

  • Zhang, Qinjin;Liu, Yancheng;Wang, Chuan;Wang, Ning
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.741-752
    • /
    • 2015
  • This study proposes a new solution for the parallel operation of microgrid inverters in terms of circuit topology and control structure. A combined three-phase four-wire inverter composed of three single-phase full-bridge circuits is adopted. Moreover, the control structure is based on adaptive three-order sliding-mode control and wireless load-sharing control. The significant contributions are as follows. 1) Adaptive sliding-mode control performance in inner voltage loop can effectively reject both voltage and load disturbances. 2) Virtual resistive-output-impedance loop is applied in intermediate loop to achieve excellent power-sharing accuracy, and load power can be shared proportionally to the power rating of the inverter when loads are unbalanced or nonlinear. 3) Transient droop terms are added to the conventional power outer loop to improve dynamic response and disturbance rejection performance. Finally, theoretical analysis and test results are presented to validate the effectiveness of the proposed control scheme.

A Study on the Power Control Characteristics of a Power Supply for Electrodeless Lamp (무전극 램프(Electrodeless Lamp) 구동용 전원장치의 전력제어 특성에 관한 연구)

  • Lee, Sung-Geun;Jeon, Su-Kyun;Jang, Min-Kyu;Kim, Dong-Sok;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.65-67
    • /
    • 2003
  • This paper describes a design of power supply for electrodeless lamp system to be easy to control electric power widely keeping the high power factor. Proposed system is composed of power factor correction(PFC) circuit, half bridge(HB) inverter, high voltage transformer, full wave rectifier to supply dc number kV's magnetron(MGT) anode voltage in the second of high voltage transformer and magnetron. It was confirmed that the proposed circuits can correct the 99.8[%] power factor and control input power of the magnetron up to 33.3[%] linearly by adjusting of pulse frequency of the inverter through the experiment.

  • PDF

Development of induction heating superheater system using new heat exchanging method (새로운 열교환 방식을 이용한 유도가열 과열증기 발생장치 개발)

  • Sul, Yong-Tae;Lee, Eui-Yong;Kwon, Hyuk-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.740-746
    • /
    • 2009
  • Two step serial load induction superheater has been proposed using resonance type induction heat method in this paper. Heat method is a type of flowing the electron induction and current to special alloy heater in body from external heat coil with non-contact method. Inverter was a full bridge serial load resonance type and inductor was used as load in LC resonance design to maximize the efficiency. The developed system is a new heat exchanging method combined with electromagnetic induction heater and fluid movement, ana very accurate to control of heating the gas, liquid and evaporated mass, so on without combustion process.