• Title/Summary/Keyword: frequency bands

Search Result 1,101, Processing Time 0.032 seconds

Indoor Wi-Fi Localization with LOS/NLOS Determination Scheme Using Dual-Band AP (이중대역 AP를 이용한 LOS/NLOS 판별 및 실내 위치 측위 기술)

  • Kim, Kangho;Lee, Suk Kyu;Jung, Jongtack;Yoo, Seungho;Kim, Hwangnam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1643-1654
    • /
    • 2015
  • With standardization of IEEE 802.11n, APs with the 2.4GHz and 5GHz dual-band capability have widely been deployed over a metropolitan area by individuals and internet service providers. Moreover, due to the increasing attentions on indoor-localization technique using Wi-Fi, the need for LOS and NLOS determination scheme is increasing to enhance accuracy of the localization. In this paper, we propose a novel LOS/NLOS determination technique by using different radio attenuation characteristics in different frequency bands and different mediums. Based on this technique, we designed a LOS/NLOS-aware indoor localization scheme. The proposed LOS/NLOS determination algorithm can be used when the distance between an user device and an AP is unknown, and the proposed localization scheme provides very accurate room-level position information. We validated the proposed scheme by implementing it on Android smart phones.

Radio Resource Sharing using Power Control of Base-station in Cognitive Radio System (코그니티브 라디오 시스템에서의 전력 제어를 이용한 무선 자원 공유)

  • Kwon, Yang-Soo;Ji, Young-Geun;Chung, Jae-Hak
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10A
    • /
    • pp.1057-1064
    • /
    • 2007
  • Cognitive radio(CR) technique which utilizes empty frequency bands allocated to private business but not being used temporally has been researched. According to the standard, CR users detect the primary user using the same channel, CR users should move to the another channel to guarantee the primary user's decodability. Thus, CR systems cannot use the same channel and support the CR user's QoS(Quality of Service) during the channel moving time. In this paper, we propose a radio resource sharing method that CR basestation controls the transmission power with the primary user's SNR(Signal to Noise Ratio) to increase the spectral efficiency of area and to minimize the outage of CR users. In addition, computer simulation demonstrates show that the proposed method improved spectral efficiency of area and decreased outage probability of CR users.

CASE STUDIES ON MHD WAVE PROPAGATION BY THE EXOS-D ELECTRIC FIELD MEASUREMENTS (EXOS-D 위성자료를 이용한 자기유체 파동 연구)

  • 황정선;이동훈
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.286-296
    • /
    • 1997
  • Magnetohydrodynamic wave phenomena have been investigated in the deep plasmasphere by the electric field measurements in the EXOS-D(Akebono) satellite. EXOS-D has highly eccentric orbits(the perigee: 274km, the apogee: 10,500km), which allows relatively long observational time interval near the apogee region compared to other satellites which pass by the same region with less eccentric orbits. Case studies are performed on one month data of October in 1989 where the apogee is located near the equator and the magnetic local time is about 9:00-12:00 a.m. in the dayside plasmasphere. The observational region ranges from L=2 to L=3 and the magnetic latitude is restricted to less than 30 degrees. The power spectrum is examined for each 128 point series of 8-sec averaged data through a FFT, which covers f = 0~62.3 mHz frequency bands. The results are well consistent with field line resonances (FLRs) and cavity modes in the plasmasphere.

  • PDF

Study About the Evaluation of Driving Stability Using 3-axis Accelerometer Test (3축 가속도 시험을 통한 도로 노면의 주행 안정성 평가에 대한 연구)

  • Lee, Dong-Hyun;Kim, Ji-Won;Mun, Sung-Ho;Jeong, Won-Seok
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.141-149
    • /
    • 2012
  • This paper attempts to evaluate driving stability by the vibration of human body. The purpose of this research is to establish an evaluation methodology for controling the quality of road surface. The study was conducted to investigate the relationship between road surface profiles (IRI, International Roughness Index) and the fatigue caused by the vibration of human body. Furthermore, 3-axis acceleration in driving vehicles was examined based on sampling sections under various road conditions. The acceleration value of frequency bands were analyzed by the characteristics of road surface, and realized the range of human influence by conditions and type of road surface with ISO-2631 standards. In general, more human fatigue by vehicle vibration was appeared in concrete pavements with high IRIs based on the analysis from given test data. Whereas, The SMA asphalt pavement and the diamond grinded concrete pavement reduce the human fatigue.

The Effect of Electroacupuncture at the BL60 (Kollyun) on the EEG (곤륜의 전침 자극이 뇌파에 미치는 영향)

  • Lee Tae-Young;Lee Kwang-Gyu;Jang Yun-Sung;Yuk Sang-Won;Lee Chang-Hyun;Lee Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.20 no.2
    • /
    • pp.31-46
    • /
    • 2003
  • Objectives : The aim of this study was to examine the effects of electroacupuncture(EA) at the BL60 (Kollyun) on normal humans using power spectral analysis. Methods : EEG power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 10 subjects $(10\;males;\;age=22.4{\pm}0.5$ years). Results : In alpha band, the power values at Fz during the non-acupoint treatment and at Fp2, T5 during the BL60-acupoint treatment significantly were decreased. In beta band, the power values at C3, Po2, O2, Oz during the BL60-acupoint treatment significantly were increased than the before-acupuncture treatment. In theta band, the power values at F7 during the BL60-acupoint treatment significantly was increased. However, the comparison with that before and after the treatment shows no significant differences in all channels.

  • PDF

Stability and Adhesion of Diamond-like Carbon Film under Micro-tensile Test Condition (미소 인장시험을 통한 다이아몬드상 카본 박막의 안정성 및 접합력 평가)

  • Choi Heon Woong;Lee Kwang-Ryeol;Wang Rizhi;Oh Kyu Hwan
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.4
    • /
    • pp.175-181
    • /
    • 2004
  • We investigated the stability of the DLC film coated on 304 stainless steel substrate by Radio frequency assisted chemical vapor deposition method. Fracture and spallation behaviour of the coating was observed during micro-tensile test of the fil $m_strate composite. As the tensile deformation progressed, the cracks of the film were observed in the perpendicular direction to the tensile axis. Further deformation resulted in the plastic deformation with $45^{\circ}$ slip bands on the substrate surface. Spallation of the film occurred with the plastic deformation, which was initiated at the cracks of the film and was aligned along the slip directions. We found that both the cracking and the spallation behaviors are strongly dependent on the pre-treatment condition, such as Ar plasma pre-treatment. The spallation of the film was considerably suppressed in an optimized condition of the substrate cleaning by Ar glow discharge. We observed the improved stability with increasing duration of Ar plasma pre-treatment.nt.

Differences of EEG and autonomic responses between olfactory stimuli with orange and valeric acid in human (오렌지향과 valeric acid향에 대한 뇌파와 자율신경계반응에 나타난 후각 감성)

  • 백은주;이윤영;이배환;문창현;이수환
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.75-79
    • /
    • 1997
  • The present study was designed to investigate whether there is a consistint changes in the signals from the central and autonomic nervous systim due to olfactory stimulation. The olfactory stimuli were 0.6% orange and 2.5% valeric acid and the stimuli through the olfactory stimulator soth controlled consistint flow, controlled concentration, and saturated with vapour to prevent drying the nasal mucosa. A room air blunk served as the control stimulus, EEG was recorede from 4channels according to the international 10-20 systim. Additionally, ECG, EOG, heart rate, skin conductance and resputation were recorded comtinuously. The fast Fourier transform analysis of EEG waves was analysed with the power spectra. Averaged power spectra were computed for the following frequency bands ; delta(0-4.5Hz), theta (4.5-7Hz), alphal(7-9.5Hz), alpha2 (9.5-12.5Hz) and beta(12.5-30Hz). Withthe results of the subjective sensibility test for the ordor, the orange was related to pleasant and familiar and the valeric acid was realted to snpleasant and bothersome. There is the difference between orange and valeric acid in alphal at PG2-A2 channel. While the unpleasant stimuli seem to be increased in alphal, alpha2 and beta waves at all channels. Also, the heart rate, galvaric skin resistance seem to be decreased by pleasant stimuli and thd unpleasant stimuli shdwed the opposite. In respiration, respiration rate had been declinig tendency, and input/output ampoitued and duration showed an upward trend by olfactory stimulation with orange, while opposite by valeric acid. In conclusion, the consistent EEG changes and the autonomic responses suggests the possibilities of the subjective signal of human sensibility.

  • PDF

Wearing Condition & Preference of Shirts for Males in Their Twenties and Thirties (20~30대 남성의 셔츠 착용실태 및 선호도 연구)

  • Seong, Hyeyun;Yi, Kyong-Hwa
    • Journal of Fashion Business
    • /
    • v.20 no.5
    • /
    • pp.60-75
    • /
    • 2016
  • This research was conducted to understand the different circumstances for wearing shirts by adult males aged 20-39, and to provide this basic information to the shirt industry prior to developing new functional men's shirts. A total of 345 respondents participated in the survey. Most of questionnaire, frequency, mean and standard deviation were calculated and the differences between the 20s and 30s were analyzed by t-test or ${\chi}^2$ test. The results of the survey are as follows. Grading the satisfaction degree of their body parts, the respondents were relatively unsatisfied with their height, weight, and waist, abdominal and hip circumferences. Majority preferred department stores, discount stores and outlets for purchasing shirts. Many have never owned tailored shirts - men in 20's had less experience with tailoring than men in 30's. The foremost selection criterion for purchasing shirts was fit -during purchase, men in their 20's considered fit more important than men in their 30's. The most preferred unbuttoning of the top button when wearing shirts. For favored collar shapes with one button unbuttoned, the most valued collar angle and style was V-neck shape when unbuttoned, low collar band, collar with unopened collar, and stiff collars. Most shirt designs and details included slim fit, no dart in the front and one dart on the back. Men in 20's more preferred the no dart in the front and one tuck on the back, as compared to men in 30's. On the other hand, men in their 30's preferred one dart shirts than men in 20's. Regarding shirt bands and cuffs, one button and regular collar and one button cuffs with round angle design, were the most preferred, respectively.

The Effect of Electroacupuncture at the PC6(Naegwan) and TE5 (Oegwan) on the EEG (내관, 외관 전침 자극이 뇌파변화에 미치는 영향)

  • Yim, Jin-Teck;Kim, Su-Hyun;Lee, Sang-Ryong
    • Journal of Pharmacopuncture
    • /
    • v.6 no.3
    • /
    • pp.91-106
    • /
    • 2003
  • Objectives : The aim of this study was to examine the effects of electroacupuncture(EA) at the PC6(Naegwan) and the TE5 (Oegwan) on nounal humans using power spectral analysis. Methods : EEG power spectrum exhibit site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 30 channel EEG study was carried out in 30 subjects(30 males ; age=23.7 years). Results : In ${\alpha}$(alpha) band, the power values at F7 channels(p<0.05) during the PC6-acupoint treatment were significantly were decreased. In ${\beta}$(beta) band, the power values at Fp1, Fz, TT1, T5, P3, P4, Po1, P02, O1, Oz, O2 channels(p<0.05) during the non-acupoint treatment and at Fp1, F4, F8 channels(p<0.05) during the TE5-acupoint treatment significantly were increased. In ${\theta}$(theta) band, the power values at Fp1 channels(p<0.05) during the non-acupoint treatment and at Oz channels(p<0.05) the TE5-acupoint treatment significantly were increased. but, the power values at F7 channels(p<0.05) during the non-acupoint treatment were significantly were decreased. In ${\delta}$(delta) band, the power values at TCP1, TCP2, CP1, T5 channels(p<0.05) during PC6-acupoint treatment were increased and the power values at F7, TT2 channels(p<0.05) during non-acupoint treatment were increased. but, the power values at the TE5-acupoint treatment significantly was decreased than the before-acupuncture treatment.

MPEG-7 Texture Descriptor (MPEG-7 질감 기술자)

  • 강호경;정용주;유기원;노용만;김문철;김진웅
    • Journal of Broadcast Engineering
    • /
    • v.5 no.1
    • /
    • pp.10-22
    • /
    • 2000
  • In this paper, we present a texture description method as a standardization of multimedia contents description. Like color, shape, object and camera motion information, texture is one of very important information in the visual part of international standard (MPEG-7) in multimedia contents description. Current MPEG-7 texture descriptor has been designed to fit human visual system. Many psychophysical experiments give evidence that the brain decomposes the spectra into perceptual channels that are bands in spatial frequency. The MPEG-7 texture description method has employed Radon transform that fits with HVS behavior. By taking average energy and energy deviation of HVS channels, the texture descriptor is generated. To test the performance of current texture descriptor, experiments with MPEG-7 Texture data sets of T1 to T7 are performed. Results show that the current MPEG-7 texture descriptor gives better retrieval rate and fast and fast extraction time for texture feature.

  • PDF