• Title/Summary/Keyword: frequency bands

Search Result 1,103, Processing Time 0.02 seconds

Design of TX/RX broadband L-type circular polarization Antenna using LTCC at K/Kaband (LTCC 공정을 이용한 K/Ka 대역에서의 송수신 겸용 L 형태 원형편파 안테나)

  • Oh, Min-Seok;Cheon, Young-Min;Kim, Sung-Nam;Choi, Jae-Ick;Pyo, Cheol-Sig;Lee, Jong-Moon;Cheon, Chang-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2052-2054
    • /
    • 2004
  • The TX/RX broadband L-type circular polarization antenna using LTCC at K/Ka band has been presented. This antenna has been analyzed in compensation for LTCC with relative permittivity 5.2 and could have been integrated with RF component. As the measured 10dB impedance circular polarization bandwidth of the proposed antenna is 7%(20.8GHz${\sim}$22.2GHz) at the K band and 2.3%(30.9GHz to 31.6GHz) at the Ka band. Also the gain of the antenna is -0.7${\sim}$3.05dBi at the K band and -2.8${\sim}$1dBi at the Ka band. The purpose of the research is to design an efficient antenna structure for satellite communication at K/Ka band. the antenna should be used for both TX and RX frequency bands. The antenna will be mounted on LTCC(Low Temperature Co-fired Ceramic) so that it can be integrated with other RF circuits. This research is important because of the following reasons. 1) The frequency ranges of satellite communication tends to move up to higher frequency such as Ka band or milimeter wave band. 2) Design of antenna for smaller size, lighter weight and less loss is preferred by most RF engineers. 3) Antennas on LTCC enables to integrate the antenna with other RF circuits, and thus, one can reduce the size and loss of the RF system.

  • PDF

Acoustic Emission during Crack Propagation Process of Rubber-Modified Epoxy Resin (고무변성 에폭시 수지의 균열진전과정과 음향방출 특성)

  • 이덕보;김현수;최낙삼;남기우;문창권
    • Composites Research
    • /
    • v.16 no.4
    • /
    • pp.44-50
    • /
    • 2003
  • The damage zone around a crack tip occurring before the fracture is a significant domain. which affects the toughening mechanism of materials. In this study. the growth process of damage zone in the vicinity of crack tip for rubber-modified epoxy resin is investigated using an acoustic emission(AE) analysis. The weight fractions of rubber(CTBN 1300$\times$B) in rubber-modified epoxy resin are 5 wt% and 15 wt%. The fracture toughness($K_{IC}$) and the fracture energy($G_{IC}$) were measured using 3 point bending single-edge notched specimens. The damage zone and rubber particles distributed around the crack tip were observed by a polarized optical microscope and an atomic force microscope(AFM). The damage zone around crack tip of rubber-modified epoxy resin was formed at 13 % loading and developed until 57 % loading of the fracture load. The crack initiated at 57 % loading grew repeatedly in the stick-slip propagation behavior. Based on time-frequency analysis, it was confirmed that AE signals with frequency bands of 0.15~0.20 MHz and 0.20~0.30 MHz were generated from cavitation and stable/unstable cracking inside the damage zone.

Design of A Dual-resonance PIFA Using U-Type Slot (U-형 슬랏을 이용한 이중 공진 PIFA 설계)

  • Kim, Yoon-Ho;Rhee, Joong-Geun;Kim, Jung-Hun;Jang, Tae-Heon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.11
    • /
    • pp.77-83
    • /
    • 2010
  • This paper presents the dual resonance PIFA(Planar Inverted F-Antenna) which satisfies the requirements of the 802.11n standard at both 2.4 GHz and 5 GHz frequency bands. Patch for 2.4 GHz and U-Type slot for 5 GHz were used for dual resonance, respectively. In this paper, the characteristics of an antenna were investigated by varying locations of short plate and feed point, the width of the short plate, the thickness and the location of U-Type slot. To investigate the characteristics of the PIFA, HFSS(High Frequency Structure Simulation) for the simulation was used. And the measurement results of a fabricated PIFA were compared with the simulated ones. The measurement and simulation results show that good dual resonance characteristics as the thickness of U-type slot decreases and when the location of U-type slot is far from the feed point.

Effects of 835-MHz Radiofrequency Radiation on the Chromosomal DNA of Mouse Thymic Lymphoma L5178Y $Tk^{+/-}$ Cells

  • Choi, Jong-Soon;Son, TaeHo;Chang, Sung-Keun;Hong, Sae-Yong
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.4
    • /
    • pp.507-512
    • /
    • 2004
  • This study was focused on the risk assessment of whether radiofrequency electromagnetic fields generated by mobile phone is cytogenetically toxic or not. We conducted the effects of 835-MHz electromagnetic field (EMF) on DNA strand breaks in mouse thymic lymphoma L5178Y $Tk^{+/1-}$ cells using alkaline comet assay. EMF frequency 835-MHz we chosen is one of the most popular communication frequency bands in Korean code-division multiple-access (CDMA) mobile phone system. The cells were exposed to 835-MHz EMF alone or 835-MHz EMF combined with cyclophosamide(CPA) or 4-nitroquinoline-1-oxide (4NQO) at specific absorption rate (SAR) of 4.0 W $kg^{-l}$ for 24 and 48hrs. DNA damage expressed as tail moment was increased more than two-fold after exposure to 835-MHz EMF for 24 and 48hr. In particular, CPA for 48hr and 4NQO for 24 hr enhanced notably the tail moment to 9-fold and 16-fold in the presence of 835-MHz EMF, respectively, compared to each single treatment. From these results, it appears that exposure to CDMA-mobile phone radiation at 835-MHz frequency may potentiate DNA strand breaks of mouse thymic lymphoma L5178Y $Tk^{+/1-}$;cells under the defined conditions of this study.

Design and fabrication of power detector for multi-band six-port direct conversion method (다중대역 6단자 직접변환 방식을 위한 전력 검파기 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2194-2200
    • /
    • 2010
  • In this paper, the power detectors using metamaterials were designed and fabricated for multi-band six-port direct conversion method. The RF short-stubs for power detector were designed by using metamaterials which provide multi-band characteristics. The power detectors with metamaterial RF short-stub were analyzed and fabricated by using lumped and distributed element. The measured results of metamaterial power detectors show the good agreement with the simulation results. The performance of lumped-metamaterial RF short-stub shows the insertion loss below 1 dB and the good frequency response characteristics. Also, the distributed-metamaterial RF short-stub shows the good frequency response characteristics and the insertion loss under that of lumped-metamaterial RF short-stub. The multi-band power detectors with metamaterial RF short-stub detect the input RF signal in the designed dual frequency bands very well.

Power Consumption Analysis of Sensor Node According to Beacon Signal Interval in IEEE 802.15.4 Wireless Star Sensor Network (IEEE 802.15.4 무선 스타 센서 네트워크에서 비콘 신호 주기에 따른 센서 노드 전력소모량 분석)

  • Yoo Young-Dae;Choi Jung-Han;Kim Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9B
    • /
    • pp.811-820
    • /
    • 2006
  • In this paper, The correlation of the power consumption of sensor node is analyzed according to the analyze parameter in IEEE 802.15.4 star sensor network. And It is studied the influence on analysis parameter. The power consumption of sensor network in transmission process and average transmission power consumption drives to numerical formula. And CSEM WiseNET system measurement value is used. As a simulation result, The power consumption of sensor node in star network consist of 10 sensor nodes is more than 20 % that in single network in average. When beacon signal interval is 0.1 second in all frequency bands, the power consumption of sensor node in up-link is more than 2.5 times that in down-link in average. When beacon signal interval is 1 second and the number of sensor nodes increases to 100 and sensing data increases to 100 byte, the power consumption of sensor node increases to 2.3 times. And The superior performance of 2.4 GHz frequency band has than 868/915 MHz frequency band up to $6{\sim}12$ times.

Comparison of the Static Balance Ability according to the Subjective Visual Vertical in Healthy Adults

  • Kwon, Jung Won;Yeo, Sang Seok
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.3
    • /
    • pp.152-156
    • /
    • 2020
  • Purpose: The subjective visual vertical (SVV) test is used to evaluate the otolith function in the inner ear. This study compared the different balance ability according to the results of the SVV in healthy adults. Methods: This study recruited 30 normal healthy subjects who did not have neurological and musculoskeletal disorders. The subjects were divided into experimental and control groups based on the results of SVV: experimental group, >2°; control group, <2°. The static balance ability was evaluated using the Fourier Index, which could evaluate the balance capacity objectively and quantitatively. Results: The mean angle of the SVV in the experimental and control groups was 4.44° and 0.59°, respectively. In the result of the Fourier series, the F1 frequency band in the experimental group showed a significantly higher value under one condition compared to the control group (p<0.05). In the F2-4 and F5-6 frequency bands, the experimental group showed a significant increase in the Fourier series value under the four conditions compared to the control group (p<0.05). In the F7-8 frequency band, significantly higher values of the Fourier series were observed in the experimental group under the three different conditions (p<0.05). Conclusion: These results showed increased trunk sway while maintaining static balance in the experimental group who showed a larger SVV angle compared to the control group. The SVV can be applied to evaluate the vestibular system and balance ability in normal adults.

Developing Tuned Mass Damper of Adjustable Damping Type to Control the Vibrations of Medical Robots (의료용 로봇의 미진동제어를 위한 가변감쇠형 동조질량감쇠기 기술 개발)

  • Cha, WoonYong;Chun, ChongKeun;Park, SangGon;Han, HyunHee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.706-715
    • /
    • 2014
  • Recently, the medical community has been enthusiastically welcoming robots that are able to provide high-quality medical services across the board, including assisting the surgeons during surgeries. In response, many higher education institutions and research facilities started to conduct various experiments and studies about these robots. During such research, it was discovered that the arm of one particular robot type that is being developed to assist surgeries are prone to vibrate even from the weakest impact, in addition to other residual vibration problems. We attempted to reduce such dynamic response by using a MF-TMD that is produced by adding magnetic fluid to ECD. We verified the MF-TMD's performance by testing it within various frequency bands and attenuations. We then designed a cantilever that was structurally similar to the robot's arm. We attached the MF-TMD to this cantilever and conducted a pilot experiment, which validated our hypothesis that MF-TMD will reduce the robot arm's vibrations through its optimal damping ratio. Henceforth, we attached the MF-TMD to the robot arm in question and conducted a performance experiment in which we tuned the MF-TMD's frequency and damping factor to its optimal level and measured the vibrations of the arm. The experiment demonstrated that the vibrations that occurred whenever the arms rotated were significantly reduced.

Spectral Analysis of Heart Rate Variability during Passive Standing after Ethanol Ingestion

  • Kim, Hyeong-Jin;Han, Chun-Duk;Yang, Eun-Kyoung;Lee, Won-Jung
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.6
    • /
    • pp.605-613
    • /
    • 1999
  • The purpose of the present study was to evaluate cardiovascular regulation during passive standing (PS) after ethanol ingestion by spectral analysis of heart rate variability (HRV) in flushed and nonflushed subjects. Of 24 young male subjects, 8 belonged to flushed group (F) and 16 to nonflushed group (NF). Two sessions of 10-min PS were performed before and after ethanol (0.5 g/kg) ingestion. Powers of R-R interval variability in very low frequency $(VLF,\;0{\sim}0.05\;Hz),$ low frequency $(LF,\;0.05{\sim}0.15\;Hz)$ and high frequency $(HF,\;0.15{\sim}0.50\;Hz)$ bands, normalized powers (LFn and HFn) and LF/HF ratio were obtained. After ethanol ingestion, F showed higher heart rate than NF. PS increased LFn $(+22.9{\pm}3.6\;in\;NF,\;+12.8{\pm}4.7$ in F, in normalized units) and LF/HF $(+3.10{\pm}0.57\;in\;NF,\;+3.00{\pm}1.08\;in\;F)$ and decreased HFn powers. Ethanol ingestion increased LFn and LF/HF and decreased HFn. PS after ethanol resulted in higher LFn and LF/HF and lower HFn than the prior PS. F showed a greater and more sustained HRV change than NF after ethanol. In conclusion, PS or ethanol ingestion increased LFn and LF/HF and decreased HFn. Flushed subjects showed an accentuated HRV response to ethanol.

  • PDF

Power Signal Inter-harmonics Detection using Adaptive Predictor Notch Characteristics (적응예측기 노치특성을 이용한 전력신호 중간고조파 검출)

  • Bae, Hyeon Deok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.5
    • /
    • pp.435-441
    • /
    • 2017
  • Detecting an inter-harmonic accurately is not easy work, because it has small magnitude, and its frequency which can be observed is not an integer multiple of fundamental frequency. In this paper, a new method using filter bank system and adaptive predictor is proposed. Filter bank system decomposes input signal to sub bands. In adaptive predictor, inter-harmonic is detected with decomposed sub band signal as input, and error signal as output. In this scheme, input-output characteristic of adaptive predictor is notch filter, as predicted harmonic is canceled in error signal, so detecting an inter-harmonic can be possible. Magnitude and frequency of detected inter-harmonic is estimated by recursive algorithm. The performances of proposed method are evaluated to sinusoidal signal model synthesized with harmonics and inter-harmonics. And validity of the method is proved as comparing the inter-harmonic detection results to MUSIC and ESPRIT.