• Title/Summary/Keyword: frequency and mode

Search Result 4,231, Processing Time 0.037 seconds

Dynamic analysis of a coupled steel-concrete composite box girder bridge-train system considering shear lag, constrained torsion, distortion and biaxial slip

  • Li Zhu;Ray Kai-Leung Su;Wei Liu;Tian-Nan Han;Chao Chen
    • Steel and Composite Structures
    • /
    • v.48 no.2
    • /
    • pp.207-233
    • /
    • 2023
  • Steel-concrete composite box girder bridges are widely used in the construction of highway and railway bridges both domestically and abroad due to their advantages of being light weight and having a large spanning ability and very large torsional rigidity. Composite box girder bridges exhibit the effects of shear lag, restrained torsion, distortion and interface bidirectional slip under various loads during operation. As one of the most commonly used calculation tools in bridge engineering analysis, one-dimensional models offer the advantages of high calculation efficiency and strong stability. Currently, research on the one-dimensional model of composite beams mainly focuses on simulating interface longitudinal slip and the shear lag effect. There are relatively few studies on the one-dimensional model which can consider the effects of restrained torsion, distortion and interface transverse slip. Additionally, there are few studies on vehicle-bridge integrated systems where a one-dimensional model is used as a tool that only considers the calculations of natural frequency, mode and moving load conditions to study the dynamic response of composite beams. Some scholars have established a dynamic analysis model of a coupled composite beam bridge-train system, but where the composite beam is only simulated using a Euler beam or Timoshenko beam. As a result, it is impossible to comprehensively consider multiple complex force effects, such as shear lag, restrained torsion, distortion and interface bidirectional slip of composite beams. In this paper, a 27 DOF vehicle rigid body model is used to simulate train operation. A two-node 26 DOF finite beam element with composed box beams considering the effects of shear lag, restrained torsion, distortion and interface bidirectional slip is proposed. The dynamic analysis model of the coupled composite box girder bridge-train system is constructed based on the wheel-rail contact relationship of vertical close-fitting and lateral linear creeping slip. Furthermore, the accuracy of the dynamic analysis model is verified via the measured dynamic response data of a practical composite box girder bridge. Finally, the dynamic analysis model is applied in order to study the influence of various mechanical effects on the dynamic performance of the vehicle-bridge system.

Spinal cord stimulation in chronic pain: technical advances

  • Isagulyan, Emil;Slavin, Konstantin;Konovalov, Nikolay;Dorochov, Eugeny;Tomsky, Alexey;Dekopov, Andrey;Makashova, Elizaveta;Isagulyan, David;Genov, Pavel
    • The Korean Journal of Pain
    • /
    • v.33 no.2
    • /
    • pp.99-107
    • /
    • 2020
  • Chronic severe pain results in a detrimental effect on the patient's quality of life. Such patients have to take a large number of medications, including opioids, often without satisfactory effect, sometimes leading to medication abuse and the pain worsening. Spinal cord stimulation (SCS) is one of the most effective technologies that, unlike other interventional pain treatment methods, achieves long-term results in patients suffering from chronic neuropathic pain. The first described mode of SCS was a conventional tonic stimulation, but now the novel modalities (high-frequency and burst), techniques (dorsal root ganglia stimulations), and technical development (wireless and implantable pulse generator-free systems) of SCS are becoming more popular. The improvement of SCS systems, their miniaturization, and the appearance of new mechanisms for anchoring electrodes results in a significant reduction in the rate of complications and revision surgeries, and the appearance of new waves of stimulation allows not only to avoid the phenomenon of addiction, but also to improve the long-term results of chronic SCS. The purpose of this review is to describe the current condition of SCS and up-to-date technical advances.

Mode of regional and mediastinal lymph node metastasis of bronchogenic carcinoma in accordance with the location, size and histology of primary tumor of the lung (폐암의 조직학적 분류, 위치 및 크기와 주위 림프절 전이의 양상에 관한 연구)

  • 김길동
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.81-89
    • /
    • 1990
  • A total of 178 patients with primary lung cancer who had undergone complete resection of the tumor in combination with complete mediastinal lymphadenectomy were reviewed at the Department of Thoracic and Cardiovascular Surgery of Yonsei Medical Center from January 1980 through July 1989. Materials; 1. There were 45 men and 33 women ranging of age from 25 to 78 years with a mean age of 55.4 years. 2. Histological types were squamous carcinoma in 115 cases [64.6%] adenocarcinoma in 42 cases [23.6 %], bronchioloalveolar carcinoma in 9 cases [5.1%], large cell carcinoma in 8 cases [4.5 %] and small cell carcinoma in 4 cases [2.2%] Results were summarized as follows: 1. The size of primary tumor was not directly proportional to the frequency of mediastinal lymph node metastasis. [P =0.0567] 2. The histologic types of the primary tumor did not related to the incidence of mediastinal lymph node metastasis. [P >0.19] 3. The chance of mediastinal lymph node metastasis in the case with lung cancer located in right middle lobe[31.8%, N=22] and left lower lobe [31.4%, N=32] were the highest and the lowest was the one located in right lower lobe, while over all incidence of mediastinal lymph node metastasis in this series was 25.4 % [N=55]. 4. The rate of mediastinal lymph node metastasis without evidence of regional and hilar lymph node metastasis was 13%. [N=23] The chance of mediastinal lymph node involvement without N1 lymph node metastasis was 16.3 % [N=17] in both upper lobes and 8.2 % [N=6] in both lower lobes. It was statistically significant that the tumors in the upper lobes had greater chance of the mediastinal lymph node metastasis without N1 than the tumors in the lower lobes. 5. In this series majority of the patients with lung cancer the mediastinal lymph node metastasis from the tumor in each pulmonary lobes usually occurs via ipsilateral tracheobronchial and paratracheal lymphatic pathway. Especially the lung cancer located in lower lobes can metastasize to subcarinal, paraesophageal and inferior pulmonary ligamental lymph node through the lymphatic pathway of inferior pulmonary ligament. It can be speculated that in some cases of this series otherwise mediastinal lymph node metastasis can also occur with direct invasion to the parietal pleura and to the mediastinal lymph node via direct subpleural lymphatic pathway .

  • PDF

Association of Blood Pressure Levels with Carotid Intima-Media Thickness and Plaques (혈압 수준과 경동맥 내중막 두께 및 동맥경화반의 관련성)

  • Lee, Young-Hoon;Kweon, Sun-Seog;Choi, Jin-Su;Rhee, Jung-Ae;Choi, Sung-Woo;Ryu, So-Yeon;Shin, Min-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.5
    • /
    • pp.298-304
    • /
    • 2009
  • Objectives : The aim of this study was to investigate the association of blood pressure levels with the common carotid artery intima-media thickness (CCA-IMT) and carotid plaques. Methods : Data were obtained from 2,635 subjects, aged 50 years and over, who participated in the Community Health Survey (a population-based, cross-sectional study) in Dong-gu, Gwangju city between 2007 and 2008. Participants were categorized into three groups according to blood pressure levels; normotensives (<120/80 mmHg), prehypertensives (120-139/80-89 mmHg), and hypertensives ($\geq$140/90 mmHg). Prehypertensives were further categorized as low prehypertensives (120-129/80-84 mmHg) and high prehypertensives (130-139/85-89 mmHg). Carotid intima-media thickness and plaques were evaluated with a high-resolution B-mode ultrasound. Statistical analyses were performed using chi-square test, ANOVA, and multiple logistic regression. Results : Prehypertensives had significantly greater maximal CCA-IMT values than normotensives, with a multivariate adjusted odds ratio of 1.78 (95% CI=1.36-2.32) for abnormal CCA-IMT (maximal CCA-IMT$\geq$1.0 mm), and 1.45 (95% CI=1.19-1.77) for carotid plaques. The multivariate adjusted odds ratio of low prehypertensives was 1.64 (95% CI=1.21-2.21) for abnormal CCA-IMT, and 1.30 (95% CI=1.04-1.63) for carotid plaques compared with normotensives. Subject with hypertension had higher frequency of abnormal CCA-IMT (odds ratio, 2.18; 95% CI=1.49-3.18), and carotid plaques (odds ratio, 1.98; 95% CI=1.46-2.67) compared with normotensives after adjustment for other cardiovascular risk factors. Conclusions : Our results indicate that there is a significant increase in the prevalence of carotid atherosclerosis in subjects with prehypertension (even in low prehypertensives) compared with normotensive subjects. Further studies are required to confirm the benefits and role of carotid ultrasonography in persons with prehypertension.

Study on Vibration Characteristics for Reducing Vibration of the Hopper-type Feeder (호퍼식급이기의 진동 저감을 위한 진동 특성 연구)

  • Lee, S.J.;Chang, D.I.;So, J.K.;Chang, H.H.;Yoon, T.J.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • This study was carried out to measure and analyze the vibration levels and modes produced by a hopper type feeder used at laying hen farms, to prevent the vibration resonance and to reduce the vibration of the hopper type feeder (6-tier). The most vibration in a layer house were produced by hopper type feeder as shown the previous study. According to the measurement results, the ratio of transmissibility was as high as 100-638% for natural frequency of 170 Hz or less. And vibration simulations were taken by the results of vibration mode analysis and the weakest points to vibrations were determined accordingly. Then measurement and analysis were taken for those points. The quantities of vibration were 4.6354-4.9118 g($g=9.81^m/s^2$) by axis. In this study, it was found that hopper type feeder generated vibration as much as to influence the ratio of laying eggs of layer. And by the analysis of vibration on the weakest points, design methods and equipment were suggested for isolating/reducing of vibration by each axis.

  • PDF

A PILOT SURVEY ON THE STATE OF FEEDING, ORAL HYGIENE CARE TOOTH ERUPTION AND CARIES IN 18-MONTH OLD INFANTS (18개월 유아의 섭식, 구강위생 관리실태 및 구강상태에 관한 기초조사)

  • Lee, Chang-Han;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.714-720
    • /
    • 2004
  • This survey was performed as a pilot of comprehensive survey of 18-month old infants which is an important period in pediatric dentistry. Through the oral examination of 154 infants of 18-month age, labored at Pusan National University Hospital and Ilsin Christian Hospital, and direct interview with their first caregivers (mother in most cases), we investigated into the state of their weaning and feeding, between-meal snacks, oral hygiene care, tooth eruption and dental caries and obtained the results as follows : 1. 73% of the infants had not yet weaned, and 82% of which were being milked during or before sleep without oral hygine care. 2. Snacks were taken in order of fruits, biscuits, cheese, bread and candies, and beverages in order of water, fermented milks, milk, sugared juice, fresh fruit juice. 61% of the infants ate snacks irregularly. 3. The toothbrush for infants was the most popular way of oral hygiene care. The mean age of initiation of tooth brushing was 13.8 months and the mean frequency was 1.6 times a day. 4. The incisors in all infants, the 1st molars in 86%, and canines in 66% were erupted. The average number of erupted teeth was 14.1. 5. The caries prevalence rate was 27.3% and 73% of total caries was observed in maxillary deciduous incisors. dmft index was 0.97. Through these results, it was concluded that a systematic education about weaning time, mode of snacking and the way of oral hygine care is required for the parents.

  • PDF

Hardware Architecture of High Performance Cipher for Security of Digital Hologram (디지털 홀로그램의 보안을 위한 고성능 암호화기의 하드웨어 구조)

  • Seo, Young-Ho;Yoo, Ji-Sang;Kim, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.17 no.2
    • /
    • pp.374-387
    • /
    • 2012
  • In this paper, we implement a new hardware for finding the significant coefficients of a digital hologram and ciphering them using discrete wavelet packet transform (DWPT). Discrete wavelet transform (DWT) and packetization of subbands is used, and the adopted ciphering technique can encrypt the subbands with various robustness based on the level of the wavelet transform and the threshold of subband energy. The hologram encryption consists of two parts; the first is to process DWPT, and the second is to encrypt the coefficients. We propose a lifting based hardware architecture for fast DWPT and block ciphering system with multi-mode for the various types of encryption. The unit cell which calculates the repeated arithmetic with the same structure is proposed and then it is expanded to the lifting kernel hardware. The block ciphering system is configured with three block cipher, AES, SEED and 3DES and encrypt and decrypt data with minimal latency time(minimum 128 clocks, maximum 256 clock) in real time. The information of a digital hologram can be hided by encrypting 0.032% data of all. The implemented hardware used about 200K gates in $0.25{\mu}m$ CMOS library and was stably operated with 165MHz clock frequency in timing simulation.

Inhibitory Effects of Naeso-san on Pacemaker Potentials in Interstitial Cells of Cajal of Murine Small Intestine (생쥐 소장 카할세포의 내향성 향도잡이 전압에 미치는 내소산의 억제효과에 관한 연구)

  • Hong, Noo Ri;Ahn, Tae Seok;Park, Hyun Soo;Chae, Han;Kwon, Young Kyu;Kim, Byung Joo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.630-635
    • /
    • 2014
  • The purpose of this study was to investigate the effects of Naeso-san in interstitial cells of Cajal (ICCs) in murine small intestine. First, we isolated ICCs from murine small intestine. After that, we cultured these cells for 1 days. The patch-clamp technique was applied on ICCs that formed network-like structures in culture (1 days). Spontaneous rhythms were routinely recorded from cultured ICCs under current-clamp conditions, and the ICCs within networks displayed more robust electrical rhythms (pacemaker potentials). To understand the relationship between Naeso-san and pacemaker activity in ICCs, we examined the effects of Naeso-san on pacemaker potentials of ICCs. In current clamp mode (I = 0), the addition of Naeso-san (10 mg/ml - 50 mg/ml) decreased the amplitude and frequency of the pacemaker potentials of ICCs in a dose dependent manner. However, these effects were blocked by intracellular $GDP{\beta}S$, a G-protein inhibitor, and glibenclamide, a specific ATP-sensitive K+ channels blocker. Pretreatment with SQ-22536, an adenylate cyclase inhibitor, did not block the Naeso-san induced effects, whereas pretreatment with ODQ, a guanylate cyclase inhibitor, or L-NAME, an inhibitor of nitric oxide (NO) synthase blocked the Naeso-san induced effects. Our findings provide insight into unraveling the modulation of Naeso-san in pacemaker potentials of ICCs and developing therapeutic agents against gastrointestinal motility disorders.

Strain-Relaxed SiGe Layer on Si Formed by PIII&D Technology

  • Han, Seung Hee;Kim, Kyunghun;Kim, Sung Min;Jang, Jinhyeok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.155.2-155.2
    • /
    • 2013
  • Strain-relaxed SiGe layer on Si substrate has numerous potential applications for electronic and opto- electronic devices. SiGe layer must have a high degree of strain relaxation and a low dislocation density. Conventionally, strain-relaxed SiGe on Si has been manufactured using compositionally graded buffers, in which very thick SiGe buffers of several micrometers are grown on a Si substrate with Ge composition increasing from the Si substrate to the surface. In this study, a new plasma process, i.e., the combination of PIII&D and HiPIMS, was adopted to implant Ge ions into Si wafer for direct formation of SiGe layer on Si substrate. Due to the high peak power density applied the Ge sputtering target during HiPIMS operation, a large fraction of sputtered Ge atoms is ionized. If the negative high voltage pulse applied to the sample stage in PIII&D system is synchronized with the pulsed Ge plasma, the ion implantation of Ge ions can be successfully accomplished. The PIII&D system for Ge ion implantation on Si (100) substrate was equipped with 3'-magnetron sputtering guns with Ge and Si target, which were operated with a HiPIMS pulsed-DC power supply. The sample stage with Si substrate was pulse-biased using a separate hard-tube pulser. During the implantation operation, HiPIMS pulse and substrate's negative bias pulse were synchronized at the same frequency of 50 Hz. The pulse voltage applied to the Ge sputtering target was -1200 V and the pulse width was 80 usec. While operating the Ge sputtering gun in HiPIMS mode, a pulse bias of -50 kV was applied to the Si substrate. The pulse width was 50 usec with a 30 usec delay time with respect to the HiPIMS pulse. Ge ion implantation process was performed for 30 min. to achieve approximately 20 % of Ge concentration in Si substrate. Right after Ge ion implantation, ~50 nm thick Si capping layer was deposited to prevent oxidation during subsequent RTA process at $1000^{\circ}C$ in N2 environment. The Ge-implanted Si samples were analyzed using Auger electron spectroscopy, High-resolution X-ray diffractometer, Raman spectroscopy, and Transmission electron microscopy to investigate the depth distribution, the degree of strain relaxation, and the crystalline structure, respectively. The analysis results showed that a strain-relaxed SiGe layer of ~100 nm thickness could be effectively formed on Si substrate by direct Ge ion implantation using the newly-developed PIII&D process for non-gaseous elements.

  • PDF

A Design and Fabrication of the X-Band Transmit/Receive Module for Active Phased Array SAR Antennas (능동 위상 배열 SAR 안테나를 위한 X-대역 송수신 모듈의 설계 및 제작)

  • Chong, Min-Kil;Kim, Sang-Keun;Na, Hyung-Gi;Lee, Jong-Hwan;Yi, Dong-Woo;Baik, Seung-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1050-1060
    • /
    • 2009
  • In this paper, a X-Band T/R-module for SAR(Synthetic Aperture Radar) systems based on active phased array antennas is designed and fabricated. The T/R modules have a and width of more than 800 MHz centered at X-Band and support dual, switched polarizations. The output power of the module is 7 watts over a wide bandwidth. The noise figure is as low as 3.9 dB. Phase and amplitude are controlled by a 6-bit phase shifter and a 6-bit digital attenuator, respectively. Further the fabricated T/R module has est and calibration port with directional coupler and power divider. Highly integrated T/R module is achieved by using LTCC(Low Temperature Co-fired Ceramic) multiple layer substrate. RMS gain error is less than 0.8 dB max. in Rx mode, and RMS phase error is less than $4^{\circ}$ max. in Rx/Tx phase under all operating frequency band, or the T/R module meet the required electrical performance m test. This structure an be applied to active phase array SAR Antennas.