• 제목/요약/키워드: frequency Ratio

검색결과 5,842건 처리시간 0.034초

구기자 가지의 진동 특성 (Vibration Characteristics of Boxthorn(Lycium chinense Mill))

  • 서정덕
    • Journal of Biosystems Engineering
    • /
    • 제26권2호
    • /
    • pp.105-114
    • /
    • 2001
  • Modulus of elasticity, modulus of rigidity, damping ratio, and natural frequency of three varieties of boxthorn (Lycium chinense Mill) (Cheongyang #2, Cheongyang gugija, and Cheongyang native) branches were analyzed. Modulus of elasticity and modulus of elasticity and modulus of rigidity of the boxthorn branch was determined using standard formula after simple beam bending and torsion test, respectively, using an universal testing machine. Damping ratio and natural frequency of branches were determined using a system consisted of an accelerometer, a PC equipped with A/D converter, and a software for data analysis. Relationship between the elastic modulus and branch diameter in overall varieties and branch types showed a good correlation (r -0.81). There was, however, no correlation between torsional rigidity and branch diameter. The internal damping results were highly variable and the overall range of the damping ratio of the boxthorn branch was 0.014-0.087, which indicated that the branch was a lightly damped structure. The natural frequency of the boxthorn branch was in the range of 89-363 rad/s for the overall varieties and branch types. A good correlation (r 0.82) existed between the natural frequency and branch diameter in overall varieties and branch type.

  • PDF

인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향 (The effect on the seasonal performance of an inverter compressor with higher and lower operating range)

  • 박윤철;하도용;민만기
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

A Protection Ratio with Composite Fade Margin for Detailed Frequency Coordination in Microwave Relay System Network

  • Suh, Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • 제7권2호
    • /
    • pp.83-90
    • /
    • 2007
  • In this paper, the formulation of the protection ratio based upon a composite fade margin and availability is newly presented for the detailed planning of frequency coordination in the microwave relay system network, and computed results for co-channel and adjacent channel protection ratios are illustrated over an actual system with 6.2 GHz. It is shown that the protection ratio to assure a quality of service can be expressed in terms of the composite fade margin, noise-to-interference ratio, net filter discrimination, and system parameters. In addition, the net filter discrimination, depending upon the transmitter spectrum mask and the overall receiver filter characteristic, has been examined to investigate the effect of the adjacent channel protection ratio caused by the adjacent channel interference. Regarding simulated results for 6.2 GHz, 60 km, 64-QAM, and N/I=6 dB at the bit error rate of $10^{-6}$, composite fade margin and co-channel protection ratio yield 25.14 and 50.3 dB, respectively. Also, the net filter discrimination of 26.5 dB and the adjacent channel protection ratio of 23.8 dB are obtained at the first adjacent channel of 30 MHz. The proposed method provides some merits in view of a comprehensive and practical application with more detailed and various system parameters needed to access the criteria for making the proper frequency coordination.

기체 전달 관로에 있어서 압력 전파의 주파수 응답에 대한 부하 임피던스의 영향 (The Effect of Load Impedances on the Frequency Response of Pressure Propagation in the Pneumatic Transmission Line)

  • 윤선주;손병진
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.344-353
    • /
    • 1994
  • This study numerically analyzed the dynamic characteristics of the frequency response on the pneumatic transmission line with load impedances. The pressure transfer function is represented by the distributed parameter line model. To validate the mathematical approximations of Bessel function ratios, the results of frequency response in a blocked line were compared with those obtained by the Infinite-product, Brown's and Square-root approximations. Special emphasis was given to the frequency response characteristics on the pneumatic transmission line with load impedances. Computations were carried out for the wide range of parameters in terms of load capacitance ratio and load resistance ratio. The present results indicated that the theoretical model is capable of accurately predicting the frequency response characteristics for any configuration of a fluid transmission line.

  • PDF

효율적인 색인어 추출을 위한 합성명사 생성 방안에 대한 연구 (Study on the Generation Methods of Composition Noun for Efficient Index Term Extraction)

  • 김미진;박미성;최재혁;이상조
    • 한국정보처리학회논문지
    • /
    • 제7권4호
    • /
    • pp.1122-1131
    • /
    • 2000
  • The efficiency of thesytem depends upon an accurate extraction capability of index terms in the system of information search or in that of automatic index. Therefore, extraction of accurate index terms is of utmost importance. This report presents the generation methods of composition noun for efficient index term extraction by using words of high frequency appearance, so that the right documents can be found during information search. For the sake of presentation of this method, index terms of composition noun shall be extracted by applying the rule of composition and disintegration to the nouns with high frequency of appearance in the documents, such as those with upper 30%∼40% of frequency ratio. In addition, for he purpose of effecting an inspection of validity in relation to a composition of high frequency nouns such as those with upper 30∼40% of frequency ratio as presented in this report, it proposes an adequate frquency ratio during noun composition. Based upon the proposed application, in this short documents with less than 300 syllables, low frequency omissions were noticed, when composed with nouns in the upper 30% of frequency ratio; whereas the documents with more than 30 syllables, when composed with nouns in he upper 40% of frequency ration, had a considerable reduction of low frequency omissions. Thus, total number of index terms has decreased to 57.7% of these existing and an accurate extraction of index terms with an 85.6% adequacy ratio became possible.

  • PDF

A Derivation of Comprehensive Protection Ratio and Its Applications for Microwave Relay System Networks

  • Suh Kyoung-Whoan
    • Journal of electromagnetic engineering and science
    • /
    • 제6권2호
    • /
    • pp.103-109
    • /
    • 2006
  • This paper suggests an efficient and comprehensive algorithm of the protection ratio derivation and illustrates some calculated results applicable to the initial planning of frequency coordination in the fixed wireless access networks. The net filter discrimination associated with Tx spectrum mask and overall Rx filter characteristic has been also examined to show the effect of the adjacent channel interference. The calculations for co-channel and adjacent channel protection ratios are performed for the current microwave frequency band of 6.7 GHz including Tx spectrum mask and Rx filter response. According to results, fade margin and co-channel protection ratio reveal 41.4 and 75.2 dB, respectively, for 64-QAM and 60 km at BER $10^{-6}$. It is shown that the net filter discrimination with 40 MHz channel bandwidth provides 28.9 dB at the first adjacent channel, which yields 46.3 dB of adjacent channel protection ratio. In addition, the protection ratio of 38 GHz radio relay system is also reviewed for millimeter wave band applications. The proposed method gives some advantages of an easy and systematic extension for protection ratio calculation and is also applied to frequency coordination in fixed millimeter wave networks.

가변 핵심 대역 하향 표본화 비를 가진 MPEG USAC 성능 평가 (A Performance Evaluation of the MPEG USAC with Variable Core-Band Down-Sampling Ratio)

  • 이재화;김인철
    • 방송공학회논문지
    • /
    • 제18권1호
    • /
    • pp.106-114
    • /
    • 2013
  • 본 논문에서는 내부 표본화 주파수와 핵심 대역 하향 표본화 비의 조정이 MPEG USAC의 전체 성능에 끼치는 영향을 다룬다. 여기서 내부 표본화 주파수는 실제 부호화될 때의 내부적인 표본화 주파수를 말한다. 핵심 대역 하향 표본화 비는 전체 부호화 대역폭에 대한 핵심 대역폭의 비를 나타낸다. 성능은 6개의 실험 음원에 대해 10명이 참가한 MUSHRA 검사를 통해 평가되었다. 실험에서는 기존의 1/2에 비해 1/3 혹은 1/4의 핵심 대역 하향 표본화 비를 사용하면 저전송률에서 부호화 성능을 향상시킬 수 있음을 보였다.

Damage detection of shear buildings using frequency-change-ratio and model updating algorithm

  • Liang, Yabin;Feng, Qian;Li, Heng;Jiang, Jian
    • Smart Structures and Systems
    • /
    • 제23권2호
    • /
    • pp.107-122
    • /
    • 2019
  • As one of the most important parameters in structural health monitoring, structural frequency has many advantages, such as convenient to be measured, high precision, and insensitive to noise. In addition, frequency-change-ratio based method had been validated to have the ability to identify the damage occurrence and location. However, building a precise enough finite elemental model (FEM) for the test structure is still a huge challenge for this frequency-change-ratio based damage detection technique. In order to overcome this disadvantage and extend the application for frequencies in structural health monitoring area, a novel method was developed in this paper by combining the cross-model cross-mode (CMCM) model updating algorithm with the frequency-change-ratio based method. At first, assuming the physical parameters, including the element mass and stiffness, of the test structure had been known with a certain value, then an initial to-be-updated model with these assumed parameters was constructed according to the typical mass and stiffness distribution characteristic of shear buildings. After that, this to-be-updated model was updated using CMCM algorithm by combining with the measured frequencies of the actual structure when no damage was introduced. Thus, this updated model was regarded as a representation of the FEM model of actual structure, because their modal information were almost the same. Finally, based on this updated model, the frequency-change-ratio based method can be further proceed to realize the damage detection and localization. In order to verify the effectiveness of the developed method, a four-level shear building was numerically simulated and two actual shear structures, including a three-level shear model and an eight-story frame, were experimentally test in laboratory, and all the test results demonstrate that the developed method can identify the structural damage occurrence and location effectively, even only very limited modal frequencies of the test structure were provided.

주파수 점유율 측정 기능의 구현 (Realization of Frequency Occupancy Measurement Function)

  • 김경석;손수호;강흥용;임성준
    • 한국전자파학회논문지
    • /
    • 제7권4호
    • /
    • pp.279-287
    • /
    • 1996
  • 주파수 점융율 데이터는 개별 주파수 채널의 실제 이용율에 대한 정보를 제공할 수 있다. 또한 스펙트럼의 예비 용량이 추정될 수 있도록 이들 주파수 대역들의 평균 이용율에 대한 정보를 제공한다. 그러한 추정치는 추가 배분 계획 및 스펙트럼 사용에 대한 새로운 기술의 영향을 평가하는 방법으로 사용될 수 있다. 본 논문에서는 국내에서 개발한 주파수 점유율 측정 시스템과 측정 방법을 제시한다. 그리고, 수도권 5개 지역의 전파감시 결과 데이터를 이용하여 주파수의 점유율을 시간대 및 지역별로 제시한다.

  • PDF

진동하는 구를 지 나는 유동의 특성 (Characteristics of Flow p ast an Oscillating Sphere)

  • 이대성;윤현식;하만영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.284-287
    • /
    • 2008
  • Flow over a sphere under forced oscillation at Re=300 is simulated for various frequency ratios which are defined as excitation frequency over natural frequency of stationary sphere. The results of oscillating sphere are compared with those of stationary sphere and an oscillating cylinder. Detailed vortical structures, hydrodynamic forces and frequencies of the wake are prescribed as a function of frequency ratio. For oscillating sphere, planar symmetry of the wake is kept and two nearly symmetric hair pin vortices are induced by oscillation for one period of oscillation when the frequency ratio is bigger than 0.5. Modulation phenomenon which can be found in an oscillating cylinder were not seen for an oscillating sphere.

  • PDF