• Title/Summary/Keyword: frequency Ratio

Search Result 5,812, Processing Time 0.032 seconds

The Altering Ratio of the luminance of a Inorganic Powder EL Lamp That was made by Screen Printing Technique (스크린 인쇄 기법에 의해 제작된 분산형 무기 EL 램프의 휘도 변화율)

  • Kang, Young-Reep;Moon, Kil-Hwan
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.29 no.2
    • /
    • pp.33-44
    • /
    • 2011
  • The inorganic powder EL lamp was made by screen printing technique with a phosphor ink and a dielectric ink. The thickness of a phosphor ink layer and a dielectric ink layer is $35{\mu}m$ and $54{\mu}m$ respectively. A increasing ratio of the luminance of inorganic powder EL lamp to be a 1P1PD-phosphor ink layer in which increased voltage at constant frequency is higher 12% than when increased frequency at constant voltage. It is higher 57% than when increased frequency at constant voltage that the rate of increase of the luminance of inorganic powder EL lamp to be a 2PD-phosphor ink layer in which increased voltage at constant frequency. Finally, when increased voltage at constant frequency, a increasing ratio of the luminance of inorganic powder EL lamp to be a 2PD-phosphor ink layer is higher about 40% than that to be a 1P1PD-phosphor ink layer.

Vibration Analysis of the Temporomandibular Joint Sounds (측두하악 관절잡음의 진동 분석)

  • Jeong, Da-Un;Jeong, Jae-Hyeon;Gang, Dong-Wan
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.232-242
    • /
    • 2008
  • 관절잡음의 발생은 측두하악 관절의 구조적, 기능적 이상의 징후로 여겨져왔다. 이러한 관절잡음을 평가하는데 electrovibratography가 비침습적이고 신뢰할만한 방법으로 제시되어 왔으며 이를 통해 관절잡음의 진동수와 진폭 및 전체 에너지 양상을 숫자화하고 도식화 하는 것이 가능하게 되었다. 기존의 연구에서 여러 가지 관절잡음의 양적, 질적 분석이 시도되어 왔다. 이번 연구의 목적은 관절 잡음이 도식화되어 나타나는 frequency spectrum pattern을 integral>300Hz/<300Hz ratio와 함께 분석하는 것이다. 본 실험에서는 Joint Vibration AnalysisTM를 사용하여 측두하악 관절 장애의 증상이 없는 10명의 대조군과 관절 잡음과 동통이 있으나 개구제한을 보이지 않는 정복성 관절원판 변위의 범주에 있는 20명의 실험군에서 관절진동을 분석하였으며 관절진동 기록 시에 Jaw tracker를 함께 사용하여 개폐구시 관절잡음 발생의 위치를 감별하고 치아접촉음을 배제하여 관절잡음을 분석하였다. 그 후 실험군을 frequency spectrum pattern에 따라 4가지 하위 그룹으로 나누어 분석하였다. 실험 결과 실험군과 대조군의 하위 그룹 1에서 유사한 frequency spectrum pattern과 ratio범위를 보였으며 실험군의 하위 그룹 2,3,4 에서는 더 불규칙한 에너지 양상을 보이는 frequency spectrum pattern과 더 큰 ratio가 관찰 되었다. 이번 연구를 통해 Joint Vibration AnalysisTM가 악관절 진동의 특성을 감별하는데 유용함을 알 수 있었고 Joint Vibration AnalysisTM를 이용한 지속적인 진동 분석이 환자 교육뿐 아니라 성공적인 턱관절 기능이상의 진단과 치료에 유용할 것으로 사료된다.

  • PDF

Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-Horizontal Area Ratio (수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안)

  • Woo, Sung-Sik;Lee, Sang-Hyun;Chung, Lan;Lee, Joung-Woo;Cho, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.653-658
    • /
    • 2008
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the Case01 to 19, the standard deviation($s_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the Case21 to 61, the standard deviation ($s_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF

The Experiment on the effect of variations of voltage frequency and duty r on the electrochemical discharge machining of Pyrex glass (전압 주파수와 파형 폭 변화에 따른 유리의 미세 전해 방전 가공 성능에 대한 실험)

  • Lee, Jung-Yong;Ahn, Yoo-Min;Ahn, Si-Hong;Park, Chi-Hyun;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3307-3309
    • /
    • 1999
  • Electrochemical discharge machining (ECDM) is a very recent technique in the fabrication of the micro-electro-mechanical system ( MEMS ) devices. This paper presents the experimental results of the machining of micro-holes on pyrex glass substrates by use of ECDM. Electrolyte is used with a KOH aqueous solution, cathode with copper, anode with platinum, and tool feed system is applied with gravity feed system. Already established experimental results were taken under the condition of constant voltage frequency. However in this paper, the effect of variation of the voltage frequency and duty ratio is considered. In this experiment, it is measured the ECDM performances with variation of the voltage frequency and duty ratio under the conditions of constant other machining variables. ECDM performances are described by the hole depth, and the top hole diameter.

  • PDF

Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-horizontal Area Ratio (수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안)

  • Woo, Sung-Sik;Chung, Lan;Lee, Joung-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.119-126
    • /
    • 2009
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the case01 to 19, the standard deviation($S_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the case21 to 61, the standard deviation($S_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

Effects of Distributed Load on the Dynamic Response of the Reinforced Concrete Slabs (분포하중이 철근 콘크리트 슬래브의 동적 거동에 미치는 영향)

  • Oh, Kyung-Yoon;Cho, Jin-Goo;Choi, Soo-Myung;Hong, Chong-Hyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.19-26
    • /
    • 2008
  • This study has been carried out to investigate the dynamic characteristics of RC slabs. For this purpose, the 20-node solid element has been used to discretize the RC slabs into two parts of concrete and rebar. The material non-linearity considering elasto-visco plastic model and the smeared crack model have been adopted in the finite element formulation. The applied load can handle step load, load intensity of harmonic load, area of distributed load and frequency. The frequency of harmonic load has an significant effect on dynamic behaviour in terms of displacement. As the frequency is increased, the effect of load amplitude is more serious. Especially, if the frequency of harmonic load exceeds 30 Hz, it is noted that the displacement by harmonic load is greater than that by step load. In case of harmonic load, the damping effect shows no certain tendency with respect to frequency of load. In details, the damping is effective when the frequency of harmonic load is 2 Hz, but there is no consistent tendency according to damping ratio. The dynamic response when the frequency of harmonic load is 3 Hz shows same result for undamped case as well as for damped case with 5% damping ratio. It is also noted that we can get the largest deflection for damped case with 1% damping ratio. However, there is not any damping effect when the frequency of harmonic load is greater than 4 Hz.

An Improved LLR Generation Technique for SC-FDMA Systems Using Frequency Domain MMSE Equalization (주파수 영역 MMSE 등화방식 기반의 SC-FDMA 시스템을 위한 개선된 LLR 생성 기법)

  • Kim, Jin-Min;Im, Tae-Ho;Kim, Jae-Kwon;Yi, Joo-Hyun;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12C
    • /
    • pp.1197-1207
    • /
    • 2009
  • Orthogonal Frequency Division Multiple Access (OFDMA) is widely used as a multiple access technique for next generation mobile communication systems, however, its main drawback is the high peak-to-average ratio (PAPR). Thus for the uplink case where the transmit power is strictly limited due to the battery life of mobile units, single carrier frequency division multiple access (SC-FDMA) with low PAPR is preferred to OFDMA method. In this paper, we propose a method to improve the performance of SC-FDMA using frequency domain MMSE equalization. The proposed improved log-likelihood ratio (LLR) generation method exploits both the diversity characteristic of channels and the reciprocity that is obtained from the received signals. The complexity of the proposed method is analyzed and its performance gain is demonstrated via a set of computer simulations.

A Study on Dynamic Properties of Short-fiber Reinforced Chloroprene Rubber (단섬유 강화 Chloroprene 고무의 동적특성 연구)

  • 이동주;류상렬
    • Composites Research
    • /
    • v.17 no.3
    • /
    • pp.45-50
    • /
    • 2004
  • The dynamic properties of short-fiber reinforced chloroprene rubber with different interphase conditions and fiber contents have been studied as functions of frequency, amplitude and temperature. The loss factor(LF) slightly increased more than 1.33% of strain and the dynamic ratio(DR) rapidly decreased with increasing strain amplitude. The LF rapidly decreased with increasing frequency especially more than 50Hz. The DR showed the lower when it compared to virgin material with increasing frequency. The LF showed the maximum at $65^{\circ}$ and rapidly decreased after that temperature. The DR showed the lower when it compared with virgin rubber with increasing temperature. Generally, the better interphase condition showed the lower LF and DR at the same testing condition. Therefore, the short-fiber reinforced rubber could have the better isolation when the frequency ratio is more than $\sqrt{2}$ compared with frequency ratio less than $\sqrt{2}$.

Analysis and Modelling of Vibration Performance for Multi-layered Corrugated Structure

  • Kim, Jin Nyul;Sim, Jae Min;Park, Min Jung;Kim, Ghi Seok;Kim, Jongsoon;Park, Jong Min
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.327-334
    • /
    • 2013
  • Purpose: The purpose of this study was to analyze for resonant frequency, vibration transmissibility and damping ratio of multi-layered corrugated structures using a random vibration test. Methods: The random vibration test was performed by the ASTM D4728 specifications using two paperboards (S120, K180) and two types of flutes (A/F, B/F). Damping ratio of the multi-layered corrugated structures was estimated using a theoretical equation derived from the measured resonant frequency and transmissibility. Results: The resonant frequency and vibration transmissibility of the multi-layered corrugated structures of K180 and B-flute were higher than those of S120 and A-flute, respectively; however, the damping ratio of each sample had the opposite tendency. The resonant frequency was inversely proportional to the sample thickness and static stress; vibration transmissibility and damping ratio were not correlated with sample thickness and static stress. In addition, we developed a mathematical model of the resonant frequency with variables of sample thickness and static stress. Conclusions: Results of this study can be useful for environment-friendly and optimal packaging design since vibration has been a key factor in cushioning packaging design.

Noise Estimation based on Standard Deviation and Sigmoid Function Using a Posteriori Signal to Noise Ratio in Nonstationary Noisy Environments

  • Lee, Soo-Jeong;Kim, Soon-Hyob
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.6
    • /
    • pp.818-827
    • /
    • 2008
  • In this paper, we propose a new noise estimation and reduction algorithm for stationary and nonstationary noisy environments. This approach uses an algorithm that classifies the speech and noise signal contributions in time-frequency bins. It relies on the ratio of the normalized standard deviation of the noisy power spectrum in time-frequency bins to its average. If the ratio is greater than an adaptive estimator, speech is considered to be present. The propose method uses an auto control parameter for an adaptive estimator to work well in highly nonstationary noisy environments. The auto control parameter is controlled by a linear function using a posteriori signal to noise ratio(SNR) according to the increase or the decrease of the noise level. The estimated clean speech power spectrum is obtained by a modified gain function and the updated noisy power spectrum of the time-frequency bin. This new algorithm has the advantages of much more simplicity and light computational load for estimating the stationary and nonstationary noise environments. The proposed algorithm is superior to conventional methods. To evaluate the algorithm's performance, we test it using the NOIZEUS database, and use the segment signal-to-noise ratio(SNR) and ITU-T P.835 as evaluation criteria.