• Title/Summary/Keyword: freezing air temperature

Search Result 159, Processing Time 0.028 seconds

Effects of Freezing-Thawing Conditions on Physicochemicnl and Histological Properties of Plaice, Paralichthys olivaceus Muscle (동결-해동 조건이 넙치육의 물리$\cdot$화학적 및 조직학적 변화에 미치는 영향)

  • CHO Young-Je;CHO Min-Sung;LEE Nam-Gul;CHOI Young-Jun;KIM Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.463-470
    • /
    • 1998
  • To improve muscle quality and prolong freshness of sashimi, the effects of freezing-thawing condition on physicochemical and rheological properties of plaice muscle were investigated. Muscle tested were frozen with quick freezing (liquid nitrogen gas) or slow freezing ($-15^{\circ}C$ air). Transition time of zone of ice crystal formation was within 10 minute for quick freezing and 110 minute for slow freezing. Time required for thawing to $0^{\circ}C$ in muscle temperature by various thawing methods was shortest with $25^{\circ}C$ tap water, followed by $15^{\circ}C$ tap water, $10^{\circ}C$ tap water, $25^{\circ}C$ air, $5^{\circ}C$ tap water and $0^{\circ}C$ cold water. Breaking strength of muscle was higher in quickly frozen sample than in slowly frozen sample. According to sashimi term, changes in breaking strength of muscle did not show any difference in quickly frozen sample, while showed significant difference in slowly frozen sample. The remaining content of ATP was not effected by freezing speed, and ATP content was apt to higher in quickly thawed sample than in slowly thawed sample. IMP was the majority of ATP and it's related compounds of sample after freezing and thawing. Collagen matrix was weakened markedly in slowly frozen sample than in quickly frozen sample.

  • PDF

Effects of Various Thawing Methods on the Quality Characteristics of Frozen Beef

  • Kim, Young Boong;Jeong, Ji Yun;Ku, Su Kyung;Kim, Eun Mi;Park, Kee Jae;Jang, Aera
    • Food Science of Animal Resources
    • /
    • v.33 no.6
    • /
    • pp.723-729
    • /
    • 2013
  • In this study, the quality characteristics due to the influence of various thawing methods on electro-magnetic and air blast frozen beef were examined. The loin and round of second grade Hanwoo were sliced into 5-7 cm thickness and packed with aerobic packaging. The packaged beef samples, which were frozen by air blast freezing at $-45^{\circ}C$ and electro-magnetic freezing at $-55^{\circ}C$, were thawed by 4 thawing methods with refrigeration ($4{\pm}1^{\circ}C$), room temperature (RT, $25^{\circ}C$), cold water ($15^{\circ}C$), and microwave (2450 MHz). These samples were thawed to the point, which were core temperature reached $0^{\circ}C$. Analyses were carried out to determine drip and cooking loss, water holding capacity (WHC), moisture contents and sensory evaluation. Frozen beef thawed by microwave indicated a lower drip loss (0.66-2.01%) than the other thawing methods (0.80-2.50%). Cooking loss after electro-magnetic freezing indicated 52.0% by microwave thawing for round compared with 41.8% by refrigeration, 50.1% by RT, and 50.8% by cold water. WHC thawing by microwave with electro-magnetic freezing didn't showed any difference depending on the thawing methods, while moisture contents was higher thawing by microwave with electro-magnetic freezing than refrigeration (71.9%), RT (75.0%), and cold water (74.9%) for round. The texture of sensory evaluation for round thawed by microwave result was the highest than refrigeration (4.7 point), RT (6.4 point) and cold water (6.6 point), while sensory evaluation was no significant difference. Therefore, it was shown that microwave thawing is an appropriate way to reduce the deterioration of meat quality due to freezing.

An Experimental Study on Heat Transfer Characteristics in the LHSS for Cool Thermal Air Conditioning (저온공조용 잠열 축열조의 열전달 특성에 관한 실험적 연구)

  • Seo, I.H.;Koh, J.Y.;Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.11-19
    • /
    • 2000
  • In this study, the basic data which were required for development of LHSS(latent heat storage system) were experimentally obtained. Experiments were carried out under the following conditions. The initial temperatures of P.C.M. which were used by parameter is $5^{\circ}C,\;9^{\circ}C$ and $14^{\circ}C$. The conditions of working fluid are $-6^{\circ}C,\;-4^{\circ}C$, and $65{\ell}$/min.. The pure water of which the freezing point is $0^{\circ}C$ was filled in the system, and the Ethylene glycol(brine) was circulated through the 10 vertical tubes as a secondary fluid in order to cool the P.C.M. down. The inlet temperature of the secondary fluid and the initial temperature of the water were varied to investigate the effects of the important design parameters. The phenomenons of temperature conversion of P.C.M. were appeared for the conductive heat transfer and free convective heat transfer by buoyancy force in this storage unit system. In order to find the effective water circulation path, we obtained P.CM. temperature distributions of 5 parts in the storage tank during freezing process.

  • PDF

A Study on the Analysis of Freezing Soil by Frost Groups and Frost Depth in Korea (우리나라 동결토의 토군별 분석과 동결심도에 관한 연구)

  • 정철호
    • Geotechnical Engineering
    • /
    • v.5 no.4
    • /
    • pp.5-16
    • /
    • 1989
  • This paper statistically analyses the freezing soil by frost group and frost depth in Korea with data from soil testing in the Korea National Housing Corporation, the climate data provided by the Central Weather Office and the data on the frost depth from the National Construction Laboratory Institute. In this paper, freezing variable are analysed such as percentage finer than 0.02 m by weight, plasticity index, freezing index, water contents of soil and frost depth etc‥‥ The result of the analysis is as follows. 1) The frost depth of Korea depends on the properties of soil rather thank the characte fistic of area. 2) The distribution map of design freezing index in 57 cities is drawn up with the maxi- mum freezing index, during past 14 years, calculated by the average of the air temperature observed four times(03 : 00.09 00, 15 : 00, 21 : 00) a day. 3) By correcting the OLS line estimated from the relationship between freezing index and frost depth, a method of utlizing the line with the upper confidence limit of 99.9% int-distribution as predicted maximum frost depth is newly introduced.

  • PDF

Combination Effect of Various Freezing and Thawing Techniques on Quality and Nutritional Attributes of Onions (다양한 냉·해동 방법에 따른 양파의 이화학적 특성 및 영양성분 변화)

  • Jung, You-Kyoung;Jang, Min-Young;Hwang, In-Guk;Yoo, Seon-Mi;Min, Sang-Gi;Jo, Yeon-Ji;Chun, Ji-Yeon;Choi, Mi-Jung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1492-1503
    • /
    • 2015
  • This study evaluated the combination effect of various freezing and thawing techniques on the quality and nutritional aspects of onions. Onions were frozen by natural air convection freezing (NCF), air blast freezing (ABF), and liquid nitrogen freezing (LNF). Onions were frozen for 76 min by NCF, 9 min by ABF, and 9 min by LNF. The freezing treatment was stopped when the core temperature reached $-12^{\circ}C$ for NCF and ABF, and $-120^{\circ}C$ for LNF. Frozen samples were thawed through natural air convection thawing, running water thawing, sonication thawing (ST), or microwave thawing. The quality and nutritional aspects of frozen-thawed onions were evaluated by measuring thawing loss, pH, texture, water content, color, and SEM image. ST was found to cause the least loss in onion sample among the tested thawing methods, whereas the freezing methods did not cause any significant loss. In our experiment, thawing is found to be a more critical technique when compared to that of freezing. There were no clear quantifications or trends of pH and water content among different freezing and thawing techniques. The highest total color difference (${\Delta}E$) was observed in the NCF sample. For morphological observation, ABF gave the smallest ice crystal size, as well as minimum cell collapse. Loss of vitamin C, free sugar, and organic acid content was lower in the ABF and ST sample, when compared to other trials. In our study, we found that combination of ABF and ST could preserve the quality and nutritional aspects of frozen-thawed onions better than other methods.

An experimental study of frost forming on the horizontal cylinder under cross flow (직교유동 내에 놓인 수평 실린더에서 서리 생성에 관한 실험적 연구)

  • 이윤빈;노승탁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.448-456
    • /
    • 1999
  • Variations of thickness and effective thermal conductivity of frost forming on the horizontal] cylinder with respect to time were measured under cross flow. The local heat flux around the cylinder was determined by measuring the radial temperature distribution in the cylinder having small holes drilled axially in which T-type thermocouples were inserted, then by using one dimensional cylindrical heat conduction equation. The thickness and the surface temperature of the frost layer around the cylinder were measured periodically while developing the frost. Each experiment was peformed by varying the Reynolds number, the temperature, and the humidity condition. Specially the dew point temperature of the most cases was below the freezing point. Experimental data showed that the frost layers on the front and the rear surface were thicker than those on the top and the bottom one which was near the separation point. The thickness and effective thermal conductivity of the frost layer were affected by inlet air velocity, temperature, and humidity. Moreover, the effective thermal conductivity and the effective thermal resistance increase with respect to time.

  • PDF

An Study on Efficiency and Application of Thermal Siphon in the Permafrost (영구동토 지대에서 Thermal Siphon의 효율성 연구)

  • Kang, Jae-Mo;Kim, Hak-Seung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

Estimation of the amount of refrigerant in artificial ground freezing for subsea tunnel (해저터널 인공 동결공법에서의 냉매 사용량 산정)

  • Son, Youngjin;Choi, Hangseok;Ko, Tae Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.255-268
    • /
    • 2018
  • Subsea tunnel can be highly vulnerable to seawater intrusion due to unexpected high-water pressure during construction. An artificial ground freezing (AGF) will be a promising alternative to conventional reinforcement or water-tightening technology under high-water pressure conditions. In this study, the freezing energy and required time was calculated by the theoretical model of the heat flow to estimate the total amount of refrigerant required for the artificial ground freezing. A lab-scale freezing chamber was devised to investigate changes in the thermal and mechanical properties of sandy soil corresponding to the variation of the salinity and water pressure. The freezing time was measured with different conditions during the chamber freezing tests. Its validity was evaluated by comparing the results between the freezing chamber experiment and the numerical analysis. In particular, the freezing time showed no significant difference between the theoretical model and the numerical analysis. The amount of refrigerant for artificial ground freezing was estimated from the numerical analysis and the freezing efficiency obtained from the chamber test. In addition, the energy ratio for maintaining frozen status was calculated by the proposed formula. It is believed that the energy ratio for freezing will depend on the depth of rock cover in the subsea tunnels and the water temperature on the sea floor.

Variationsin Air and Ground Temperatures During a Frozen Season in the Subalpine Zone of Mt. Halla (한라산 아고산대의 동결기 기온 및 지온변화)

  • Kim, Taeho
    • Journal of The Geomorphological Association of Korea
    • /
    • v.20 no.3
    • /
    • pp.95-107
    • /
    • 2013
  • In order to examine the temperature regime responsible for periglacial processes, air and ground temperatures were monitored from October 2010 to May 2011 at a subalpine bare patch (1,710m asl) of Mt. Halla. Four thermistor sensor probes were installed at 55 cm above a ground surface and depths of 2 cm, 10 cm, and 20 cm, respectively. A mean air temperature is $-0.1^{\circ}C$, while mean ground temperatures are $1.8^{\circ}C$ at 2 cm, $2.6^{\circ}C$ at 10 cm and $3.2^{\circ}C$ at 20 cm deep. A mean monthly ground temperature at 2 cm deep demonstrates below $0^{\circ}C$ successively from January to March, while those at 10 cm and 20 cm deep show no sub-zero temperature. A total of 72 freeze-thaw cycle was observed in air temperature. However, the numbers in ground temperature reduced into 17 at 2 cm, 8 at 10 cm, and 3 at 20 cm deep. The cycles of air temperature and ground temperature at 2 cm deep mostly fluctuated diurnally, while those of ground temperature at 10 cm and 20 cm deep exhibited a several-daily oscillation. Snow cover over 55 cm high remained from January to early April, and it seemed to disappear completely on April 16. A seasonal frost of at least 2 cm thick was formed on late December and the isotherm of $0^{\circ}C$ descended slowly into 10 cm deep on late March to early April due to the insulating snow cover. It showed the maximum freezing depth of 20 cm on April 7 to 14 and then thawed rapidly so that the frozen ground did not longer after April 17. Periglacial processes are predominant during a freezing period than a thawing period when the ground surface is still covered with snow. The periglacial mass movement in the subalpine zone of Mt. Halla is mainly generated by frost creep in terms of the occurrence depth of diurnal freeze-thaw cycle and the maximum freezing depth of ground.

Computational Analysis for Effects of Cooling System on Homogeneity of Ice Thickness and Temperature on Water Surface (빙해수조 공냉 시스템 변화에 따른 결빙 균질도 비교 전산해석)

  • Lee, Sungsu;Kim, Young-Min;Lee, Chun-Ju
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.3
    • /
    • pp.167-174
    • /
    • 2013
  • Model ice forming process in ice tank needs several steps of seeding, freezing, tempering. In those process, one of the most important factors to affect the accuracy of experiment is the homogeneity of the ice thickness and the temperature. This paper investigated a computational and statistical method to assess the uniformity of the model ice. In addition, the different configurations of freezing systems were considered to improve the uniformity. Qualitative assessment using streamlines from the cooling units was carried out by computational fluid dynamics (CFD) and the quantitative evaluations of the homogeneity were compared using the temperature distribution on the ice surface. In addition, multi species transport analysis is introduced to understand the circulation efficiency of cold air from the cooling units. As the results, optimized configurations were determined by adjusting the angles of vane in the cooling units.