• 제목/요약/키워드: frame buildings

검색결과 688건 처리시간 0.025초

Seismic evaluation of RC stepped building frames using improved pushover analysis

  • Sarkar, Pradip;Prasad, A. Meher;Menon, Devdas
    • Earthquakes and Structures
    • /
    • 제10권4호
    • /
    • pp.913-938
    • /
    • 2016
  • 'Stepped building' frames, with vertical geometric irregularity, are now increasingly encountered in modern urban constructions. This paper proposes a new approach to determine the lateral load pattern, considering the contributions from the higher modes, suitable for pushover analysis of stepped buildings. Also, a modification to the displacement coefficient method of ASCE/SEI 41-13 is proposed, based on nonlinear time history analysis of 78 stepped frames. When the newly proposed load pattern is combined with the modified displacement coefficient method, the target displacement for the stepped building frame is found to match consistently the displacement demand given by the time history analysis.

Lateral force-displacement ductility relationship of non-ductile squat RC columns rehabilitated using FRP confinement

  • Galal, K.
    • Structural Engineering and Mechanics
    • /
    • 제25권1호
    • /
    • pp.75-89
    • /
    • 2007
  • Post-earthquake reconnaissance and experimental research indicate that squat reinforced concrete (RC) columns in existing buildings or bridge piers are vulnerable to non-ductile shear failure. Recently, several experimental studies were conducted to investigate upgrading the shear resistance capacity of such columns in order to modify their failure mode to ductile one. Among these upgrading methods is the use of fibre-reinforced polymer (FRP) jackets. One of the preferred analytical tools to simulate the response of frame structures to earthquake loading is the lumped plasticity macromodels due to their computational efficiency and reasonable accuracy. In these models, the columns' nonlinear response is lumped at its ends. The most important input data for such type of models is the element's lateral force-displacement backbone curve. The objective of this study is to verify an analytical method to predict the lateral force-displacement ductility relationship of axially and laterally loaded rectangular RC squat columns retrofitted with FRP composites. The predicted relationship showed good accuracy when compared with tests available in the literature.

Performance of multi-storey structures with high damping rubber bearing base isolation systems

  • Karabork, Turan
    • Structural Engineering and Mechanics
    • /
    • 제39권3호
    • /
    • pp.399-410
    • /
    • 2011
  • Base isolation, having quite simple contents, aims to protect the buildings from earthquake-induced damages by installing structural components having low horizontal stiffness between substructure and superstructure. In this study, an appropriate base isolation system for 2-D reinforced concrete frame is investigated. For different structural heights, the structural systems of 2, 3 and 4 bays are modeled by applying base isolation systems and results are compared with conventional structural systems. 1999 Marmara earthquake data is used for applying the model by time history method in SAP2000 package. Results of various parameters such as base shear force, structure drift ratio, structure period and superstructure acceleration are discussed for all models.

무량판 슬래브와 H형강 기둥 접합부 상세 개발 (Development for Connection Details between Flat Plate Slab and H-Steel Column)

  • 윤명호;이윤희
    • 복합신소재구조학회 논문집
    • /
    • 제5권1호
    • /
    • pp.22-27
    • /
    • 2014
  • The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.

The Structural Design of "China Zun" Tower, Beijing

  • Liu, Peng;Cheng, Yu;Zhu, Yan-Song
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.213-220
    • /
    • 2016
  • The "China Zun" tower in Beijing will rise to 528 meters in height and will be the tallest building in Beijing once built. Inspired by an ancient Chinese vessel, the "Zun", the plan dimensions reduce gradually from the bottom of the tower to the waist and then expand again as it rises to form an aesthetically beautiful and unique geometry. To satisfy the structural requirement for seismic and wind resistance, the structure is a dual system composed of a perimeter mega structure made of composite mega columns, mega braces, and belt trusses, and a reinforced-concrete core with steel plate-embedded walls. Advanced parametric design technology is applied to find the most efficient outer-perimeter structure system. The seismic design basically follows a mixed empirical and performance-based methodology that was verified by a shaking table test and other specimen lab tests. The tower is now half-way through its construction.

커튼월용 1액형 구조용 실란트 물성 평가 연구 (Evaluation of one component structural sealant for curtain wall.)

  • 한창화;정진영;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.228-229
    • /
    • 2014
  • Recently, to ensure the high openness and prospect right of the building, curtain wall system is mainly applied to the high-rise buildings at domestic and overseas. As a result, the use of Structural Sealant is increasing. Structural Glazing Sealant is applied with the glass and AL-FRAME (Mullion) that the strong structural strength is required to hold. However, the structural sealant at the construction site in a variety of external influences, such as wind load, thermal load, uv, chemical pollutants etc, in case of storing condition, if structural sealant stored in high temperature for a long period time, it will not perform well compared with initial performance. In this study, the influence of the performance of one-component structural sealant evaluated for proper storage conditions at the construction site and how to use the non-intended.

  • PDF

바로크적 특성으로 본 한국 사찰건축 -공주 마곡사를 대상으로- (A Study oA study on the Baroquely characteristics in Korean Temple Architecture)

  • 고인룡;동재욱
    • 한국디지털건축인테리어학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-44
    • /
    • 2002
  • Purpose of this paper is to find the Baroquely characteristics in Korean Temple Architecture.(MA KOK-SA) We could find out the characteristics as follows; First, visual freedom and floating in the arrangement of the temple buildings through segmenting the axis. Second, tension of variations in size, distance, and frame. Third, diverse sceneries provided by Sequential(dynamic) view points. Fourth, visual process and sharp contrast between horizontality and verticality, and unexpected scenery, etc.

  • PDF

비선형요구내력스펙트럼을 이용한 철근콘크리트건물의 지진손상도 평가법 - Part II. 지진손상도 평가법 평가사례 - (A New Methodology of Earthquake Damage Evaluation for R/C Buildings Based on Non-linear Required Strength Spectrum - Part II. A example of Earthquake Damage Evaluation -)

  • 위정두;전경주;이강석;최윤철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.113-114
    • /
    • 2010
  • 본 연구에서는 Part I에서 제안한 평가법를 이용하여 철근콘크리트 건물의 지진손상도를 평가하였다. 본 평가법의 특징은 비선형 지진해석 및 능력스펙트럼(C.S.M)등의 상세 성능평가 방법을 사용하지 않고도 비선형요구내력스펙트럼을 통해 특정 연성률에 대한 지진입력수준, 잔존내진성능 그리고 붕괴메커니즘을 효과적으로 파악 할 수 있다는 점이다.

  • PDF

Seismic behavior of special moment-resisting frames with energy dissipating devices under near source ground motions

  • Bayat, Mahmoud;Bayat, Mahdi
    • Steel and Composite Structures
    • /
    • 제16권5호
    • /
    • pp.533-557
    • /
    • 2014
  • In this study, the performances of the SMRF building equipped with energy dissipating devices are studied. Three types of these structures with different heights are considered. The Added Damping and Stiffness (ADAS) devices are used as energy dissipating devices in these structures. The behavior of these structures with ADAS devices subjected to near source ground motions are investigated. Three SMRF buildings with five, ten and fifteen-story, with ADAS devices were chosen. The nonlinear time history analysis was used by applying the near source ground motions with PERFORM 3D.V4 and conclusions are drawn upon an energy criterion. The effect of PGA variation and height of the frames are also considered based on the energy criterion.

Shaking Table Test and Seismic Performance Evaluation of Shanghai Tower

  • Chunyu, Tian;Congzhen, Xiao;Hong, Zhang;Jinzhe, Cao
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.221-228
    • /
    • 2012
  • Shanghai Tower is a super high-rise building of 632 m height with 'mega frame-core- outrigger truss' structure system. Due to the complexity and irregularity of structure, shaking table test was carried out to investigate its seismic performance. A 1/40 scaled test model was designed, built and tested on shaking table under earthquake of small, moderate and large levels. The experimental results showed that the structure can meet the requirements of Chinese codes and reach scheduled performance objectives. Elastic and plastic time-history analysis on the structure were carried out and the results were compared to experimental results. Based on the research results some suggestions were proposed to contribute favorable effect on the seismic capacity of the structure.