• 제목/요약/키워드: fracture repair

검색결과 254건 처리시간 0.028초

Tibiotarsal and Ulnar Fracture Repair in a Great Horned Owl (Bubo virginianus)

  • Yoon, Hun-Young;Fox, Derek B.;Jeong, Soon-Wuk
    • 한국임상수의학회지
    • /
    • 제25권3호
    • /
    • pp.218-220
    • /
    • 2008
  • A 1.4 kg adult great homed owl was presented to the University of Missouri-Columbia Veterinary Teaching Hospital after being found by the side of the highway. Physical examination revealed soft tissue injuries to the left wing and leg, and good body condition (body score 4/5). The radiographs revealed comminuted fracture of the diaphysis of the left tibiotarsus (severe) and ulna (mild). Closed reduction of the fracture was performed to the left tibiotarsus and ulna. System combining an intramedually (IM) Kirschner pin, IM Kirschner pin for external skeletal fixation, and polymethylmethacrylate was used for fracture repair. At 13 weeks, radiographs revealed that bridging callus was well formed over cortices of the fracture area. No physical, behavioral, or other assessable impairment was found during the rehabilitation period.

Fracture of Proximal Humerus in the Lateral Anchor Site after Suture Bridge Repair - A Case Report

  • Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Keum, Sang-Wook;Kil, Kyoung-Min;Lim, Chae-Wook;Park, Sang-Jun
    • Clinics in Shoulder and Elbow
    • /
    • 제17권3호
    • /
    • pp.134-137
    • /
    • 2014
  • To report the fracture of proximal humerus in the lateral anchor site after suture bridge repair. A 57-year-old female patient with shoulder pain on the right-side was admitted through the emergency room following a car accident. Seven weeks before the accident, the patient had undergone surgery at a different hospital for the repair of supraspinatus tendon rupture on the right-side via suture bridge technique. Humerus surgical neck fracture was confirmed by X-ray, and proximal humerus fracture at the anchor site was confirmed by magnetic resonance imaging. Following 7 months of conservative treatment resulted in satisfactory bone union and motion of the shoulder joint. We report the need of close observation during and after the arthroscopic repair of the rotator cuff in patients with osteoporosis.

Porcelain repair - Influence of different systems and surface treatments on resin bond strength

  • Yoo, Ji-Young;Yoon, Hyung-In;Park, Ji-Man;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.343-348
    • /
    • 2015
  • PURPOSE. The purpose of this study was to evaluate the bond strength of composite resin on the fracture surface of metal-ceramic depending on the repair systems and surface roughening methods. MATERIALS AND METHODS. A total of 30 disk specimens were fabricated, 15 of each were made from feldspathic porcelain and nickel-chromium base metal alloy. Each substrate was divided into three groups according to the repair method: a) application of repair system I (Intraoral Repair Kit) with diamond bur roughening (Group DP and DM), b) application of repair system I with airborne-particle abrasion (Group SP and SM), and c) application of repair system II (CoJet Intraoral Repair System, Group CP and CM). All specimens were thermocycled, and the shear bond strength was measured. The data were analyzed using the Kruskal-Wallis analysis and the Mann-Whitney test with a significance level of 0.05. RESULTS. For the porcelain specimens, group SP showed the highest shear bond strength ($25.85{\pm}3.51MPa$) and group DP and CP were not significantly different. In metal specimens, group CM showed superior values of bond strength ($13.81{\pm}3.45MPa$) compared to groups DM or SM. CONCLUSION. Airborne-particle abrasion and application of repair system I can be recommended in the case of a fracture localized to the porcelain. If the fracture extends to metal surface, the repair system II is worthy of consideration.

Hemisection and Endodontic Treatment of First Molar Tooth and Mandibular Fracture Repair in a Dog

  • Kim, Gyu-min;Kim, Jury;Bae, Hyeon-a;Kim, Nam-soo;Ji, Dong-Beom
    • 한국임상수의학회지
    • /
    • 제36권2호
    • /
    • pp.106-108
    • /
    • 2019
  • This clinical report describes hemisection and endodontic treatment of first molar tooth and mandible fracture repair in a dog. A 10 years old spayed female shih-tzu was diagnosed as left mandibular fracture by oral examination and dental radiography. First, partial odontectomy of mesial root of mandibular first molar placed in fracture line was performed, and then endodontic treatment of distal root and bone graft in extraction site was performed. Thereafter the fracture region was fixed with interdental wiring and acryl resin splint. Mandibular fracture site was healed without any complications, observed for 19 weeks follow-up period. Upon this result, this case is proving that fractured mandible can be treated successfully with hemisection followed by bone graft, interdental wiring and acryl resin splint to preserve the remaining tooth for mastication rather than tooth extraction.

Comminuted Radial Head Fracture in All-arthroscopic Repair of Elbow Fracture-dislocation: Is Partial Excision of the Radial Head an Acceptable Treatment Option?

  • Yang, Hee Seok;Kim, Jeong Woo;Lee, Sung Hyun;Yoo, Byung Min
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.234-239
    • /
    • 2018
  • Background: In elbow fracture-dislocation, partial excision of the comminuted radial head fracture that is not amenable to fixation remains controversial considering the accompanying symptoms. This study was undertaken to evaluate the results of radial head partial excision when the comminuted radial head fracture involved <50% of the articular surface in all-arthroscopic repair of elbow fracture-dislocation. Methods: Patients were divided into two groups based on the condition of the radial head fracture. In Group A, the patients had a radial head comminuted fracture involving <50% of the articular surface, and underwent arthroscopic partial excision. Group B was the non-excision group comprising patients with stable and non-displacement fractures. Follow-up consultations were conducted at 6 weeks and at 3, 6, 12, and 24 months after surgery. Results: In all, 19 patients (Group A: 11; Group B: 8) met the inclusion criteria and were enrolled in the study. At the final follow-up, all 19 patients showed complete resolution of elbow instability. No significant differences were observed in the range of motion, visual analogue scale score, and Mayo elbow performance score between groups. Radiological findings did not show any complications of the radiocapitellar joint. However, nonunion of the coracoid fracture was observed in 3 patients (Group A: 1; Group B: 2), without any accompanying instability and clinical symptoms. Conclusions: Considering that the final outcome is coronoid fracture fixation and lateral collateral ligament complex repair for restoring elbow stability, arthroscopic partial excision for radial head comminuted fractures involving <50% of articular surface is an effective and acceptable treatment for elbow fracture-dislocation.

저강도 초음파치료의 골절치유 효과 (Effect of Low-Intensity Ultrasound on Bone Growth)

  • 이충휘;김종만;황태선
    • 한국전문물리치료학회지
    • /
    • 제5권3호
    • /
    • pp.34-41
    • /
    • 1998
  • Noninvasive low intensity ultrasound has been shown to be an effective means of accelerating bone fracture repair in both animal and clinical studies. The effects of ultrasound stimulation on bone repair after fibular osteotomy were assessed in a rabbit fibular fracture model. Bilateral closed fibular fractures were made in skeletally mature male White Japanese rabbits. In this study, 24 subjects were randomly divided into 2 groups: experimental group 1 (n=12), and experimental group 2 (n=12). Experimental group 1 received 0.875 MHz continuous ultrasound and Experimental group 2 was treated with 3 MHz continuous u1trasound. The ultrasound intensity was 50 $mW/cm^2$ and treatment time was 10 minutes for every session in both groups. In each rabbit, one fibula served as a control and the other was subjected to ultrasound treatment 5 times per week for 3 weeks. After 3 weeks, rabbits were sacrificed and the ratios of the area between the trabeculae and bone marrow of the fibulae were calculated. At the end of the experimental period, 14 of the 24 rabbits were excluded due to complications from surgery or inadequate fracture status for this study. There was no statistically significant difference in the trabeculae area between experimental leg and control leg in experimental group 1 and experimental group 2 (p>0.05). And there was also no statistic-statistically significant difference between experimental group 1 and experimental group 2 according to ultrasound treatment frequencies, 0.875 MHz and 3 MHz (p>0.05). These data suggest that in Japanese white rabbits, low intensity ultrasound stimulation does not facilitate fracture repair nor is there any difference in fracture repair results between ultrasound frequencies, 0.875 MHz and 3 MHz.

  • PDF

Fatigue Behavior of Cracked Al 6061-T6 Alloy Structures Repaired with Composite Patch

  • Yoon, Young-Ki;Park, Jong-Joon;Kim, Guk-Gi;Yoon, Hi-Seak
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권3호
    • /
    • pp.5-10
    • /
    • 2001
  • Due to the development of high-strength fibers and adhesives, it is now possible to repair cracked metallic plates by bonding reinforced patches to the plate over the crack. In this study, pre-cracked aluminum 6061-T6 alloy plates repaired with bonded carbon/epoxy composite patch are applied to investigate the effect of various patch shapes on the tensile strength and the fatigue behavior of the structure. A non-patch-boned cased and 2 type-50$\times$50, 40$\times$20 mm-composite patch-bonded cases were tested to obtain fracture loads and fatigue crack growth rate. The results showed that the patch-bonded repair improves the static strength by 17% and the fatigue life by 200% compared to non-repaired case. It means that patch-boned repair is more effective in the fatigue life. It was also revealed that the patching method along crack growth direction is more efficient in cost and weight reduction. By observing the fractography, patch-bonded repair specimens demonstrated zigzag fracture patterns compared with the non-patched specimens, which shows a typical ductile fracture.

  • PDF

도재파절 양상에 따른 수종의 도재 수복용 레진의 결합력에 관한 실험적 연구 (A comparison of the shear bond strength between porcelain repair systems and fractured surface of porcelain-fused-to-metal restorations)

  • 최정원;한동후;정창모
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.147-163
    • /
    • 1990
  • Although dental porcelain demonstrates lasting esthetic results, it suffers from inherent brittle fractures. Various techniques and materials for intraoral porcelain repair has been suggested. This study investigated the in vitro shear strength of three porcelain repair systems according to aspects of the porcelain fractures. The purpose of this study was to evaluate the shear bond strength of three porcelain repair systems(All-bond, Clearfil, Scotchprime) according to fractured surface of porcelain - fused - to - metal restorations. For this study specimens were divided into five groups : group 1 represented fracture occurred at body porcelain layer, group 2 represented fracture occurred at opaque porcelain layer, group 3 represented fracture including 1/3 of metal exposure, group 4 represented fracture including 2/3 of metal exposure, and group 5 represented all metal surface was exposed. Specimens were stored in double deionized water(24Hr, $37^{\circ}C$) and thermocycling was performed(24Hr, 1080cycles), and subjected to a shear force parallel to the repair resin and porcelain interface by use of an University Testing Machine. The results of this study were obtained as follows : 1. In group 1 and 2, bond strength was relatively high, and bond strength showing reducing tendency as exposure of metal was increased. 2. In group 1, bond strength was relatively high, and no significant differences in porcelain repair system. 3. In group 2, 3 and 4, All-bond and Clearfil provided significantly higher bond strength than scotchprime. 4. In group 5, bond strength was the lowest among all groups and especially in case if Scotchprime. 5. Cohesive failure was observed in group 1 and 2, adhesive failure was observed in group 5, and cohesive / adhesive failures were observed in group 3 and 4.

  • PDF

The Merits of Mannitol in the Repair of Orbital Blowout Fracture

  • Shin, Kyung Jin;Lee, Dong Geun;Park, Hyun Min;Choi, Mi Young;Bae, Jin Ho;Lee, Eui Tae
    • Archives of Plastic Surgery
    • /
    • 제40권6호
    • /
    • pp.721-727
    • /
    • 2013
  • Background One of the main concerns in orbital blowout fracture repair is a narrow operation field, due mainly to the innate complex three dimensions of the orbit; however, a deep location and extensive area of the fracture and soft tissue edema can also cause concern. Swelling of the orbital contents progresses as the operation continues. Mannitol has been used empirically in glaucoma, cerebral hemorrhage, and orbital compartment syndrome for decompression. The authors adopted mannitol for the control of intraorbital edema and pressure in orbital blowout fracture repair. Methods This prospective study included 108 consecutive patients who were treated for a pure blowout fracture from January 2007 to October 2012. For group I, mannitol was administered during the operation. Under general anesthesia, all patients underwent surgery by open reduction and insertion of an absorbable mesh implant. The authors compared postoperative complications, the reoperation rate, operation time, and surgical field improvement between the two groups. Results In patients who received intraoperative administration of mannitol, the reoperation rate and operation time were decreased; however, the difference was not statistically significant. The total postoperative complication rates did not differ. Panel assessment for the intraoperative surgical field video recordings showed significantly improved vision in group I. Conclusions For six years, mannitol proved itself an effective, reliable, and safe adjunctive drug in the repair of orbital blowout fractures. With its rapid onset and short duration of action, mannitol could be one of the best methods for obtaining a wider surgical field in blowout fracture defects.

삼각인대 손상 의심 시 진단과 치료방법 (Diagnosis and Management of Suspected Deltoid Injury)

  • 양성훈;이준영
    • 대한족부족관절학회지
    • /
    • 제26권1호
    • /
    • pp.16-21
    • /
    • 2022
  • 도수 또는 중력 외회전 부하 방사선 검사는 족관절 양과 유사 골절과 단독 외과 골절을 구별할 수 있는 기준이 된다. 부하 방사선 검사상 내측 관절 간격이 넓어지면 삼각인대 손상을 진단할 수 있고 비골 골절에 대한 수술적 처치가 권장된다. 비골 골절에 대하여 관혈적 정복술 후 Cotton test를 시행하여 경비원위인대가 벌어질 경우 이에 대한 고정을 시행한 후 삼각인대의 봉합술 시행 여부는 술자의 선호도 및 수술장 내 소견에 의하여 결정된다. 삼각인대 봉합술은 내과에 suture anchor를 삽입하고 심부와 천부 삼각인대에 대하여 중첩술 후 내과에 anchor를 통하여 고정함으로써 시행한다. 유일하게 무작위로 시행된 족관절 골절에서의 삼각인대 봉합술의 유용성 평가 연구에서는 삼각인대 봉합술의 유용성에 대하여 긍정적인 결론을 도출하지 못하였으나 연구 자체의 제한점이 많아 해석을 하는 데 있어 한계가 있었다. 추후 이에 대한 심도 있는 연구가 필요하리라 판단된다.