• 제목/요약/키워드: fracture detection

검색결과 174건 처리시간 0.028초

Damage Detection in Fiber Reinforced Composites Containing Electrically Conductive Phases

  • Shin, Soon-Gi;Hideaki Matsubara
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.201-205
    • /
    • 2000
  • Fiber reinforced plastic (FRP) composites and ceramic matrix composites (CMC) which contain electrically conductive phases have been designed and fabricated to introduce the detection capability of damage/fracture detection into these materials. The composites were made electrically conductive by adding carbon and TiN particles into FRP and CMC, respectively. The resistance of the conductive FRP containing carbon particles showed almost linear response to strain and high sensitivity over a wide range of strains. After each load-unload cycle the FRP retained a residual resistance, which increased with applied maximum stress or strain. The FRP with carbon particles embedded in cement (mortar) specimens enabled micro-crack formation and propagation in the mortar to be detected in situ. The CMC materials exhibited not only sensitive response to the applied strain but also an increase in resistance with increasing number of load-unload cycles during cyclic load testing. These results show that it is possible to use these composites to detect and/or fracture in structural materials, which are required to monitor the healthiness or safety in industrial applications and public constructions.

  • PDF

Detection of formation boundaries and permeable fractures based on frequency-domain Stoneley wave logs

  • Saito Hiroyuki;Hayashi Kazuo;Iikura Yoshikazu
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 2004
  • This paper describes a method of detecting formation boundaries, and permeable fractures, from frequency-domain Stoneley wave logs. Field data sets were collected between the depths of 330 and 360 m in well EE-4 in the Higashi-Hachimantai geothermal field, using a monopole acoustic logging tool with a source central frequency of 15 kHz. Stoneley wave amplitude spectra were calculated by performing a fast Fourier transform on the waveforms, and the spectra were then collected into a frequency-depth distribution of Stoneley wave amplitudes. The frequency-domain Stoneley wave log shows four main characteristic peaks at frequencies 6.5, 8.8, 12, and 13.3 kHz. The magnitudes of the Stoneley wave at these four frequencies are affected by formation properties. The Stoneley wave at higher frequencies (12 and 13.3 kHz) has higher amplitudes in hard formations than in soft formations, while the wave at lower frequencies (6.5 and 8.8 kHz) has higher amplitudes in soft formations than in hard formations. The correlation of the frequency-domain Stoneley wave log with the logs of lithology, degree of welding, and P-wave velocity is excellent, with all of them showing similar discontinuities at the depths of formation boundaries. It is obvious from these facts that the frequency-domain Stoneley wave log provides useful clues for detecting formation boundaries. The frequency-domain Stoneley wave logs are also applicable to the detection of a single permeable fracture. The procedure uses the Stoneley wave spectral amplitude logs at the four frequencies, and weighting functions. The optimally weighted sum of the four Stoneley wave spectral amplitudes becomes almost constant at all depths, except at the depth of a permeable fracture. The assumptions that underlie this procedure are that the energy of the Stoneley wave is conserved in continuous media, but that attenuation of the Stoneley wave may occur at a permeable fracture. This attenuation may take place at anyone of the four characteristic Stoneley wave frequencies. We think our multispectral approach is the only reliable method for the detection of permeable fractures.

초음파-파면해석에 의한 대차 프레임의 건전성 평가 (Integrity evaluations of bogie frame using ultrasonic-fractography analysis)

  • 윤인식;권성태;정우현;박덕신;김경국
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.461-467
    • /
    • 2000
  • This study proposes the integrity evaluation of bogie frame using ultrasonic waves-fractography analysis. Analysis objectives in this study are to investigate fracture planes of damaged zone by the A-scan method. The surface condition of fracture plane shows degree of degradation by stress concentration. The detection of the natural defects in bogie frame is performed using the characteristics of echodynamic pattern in ultrasonic signal. Results of ultrasonic testing agree fairly well with those of actual fracture plane. In quantitative fractography analysis, microstructures of actual fracture plane turned out to be intergranular and transgranular fracture, Proposed ultrasonic-fractography analysis in this study can be used for the integrity evaluation of the bogie frame

  • PDF

AE에 의한 알루미나 세라믹스의 Microcrack 생성과 파괴거동의 평가 (Evaluation of Fracture Behavior and Formation of Microcrack of Alumina Ceramics by Acoustic Emission)

  • 장병국;우상국
    • 한국세라믹학회지
    • /
    • 제35권6호
    • /
    • pp.551-558
    • /
    • 1998
  • Detection of microcrack in {{{{ {Al }_{2 } {O }_{3 } }} ceramics were studided by AE(acoustic emission) technique with 4-point bending test in order to evaluate the fracture process and formation of microcrack. Fully-dense alu-mina ceramics having a different grain size were fabricated by varing the hot-pressing temperature. The grain size of alumina increased with increasing the hot-pressing temperature whereas the bending strength decreasd. The microcracks were observed by SEM and TEM. The generation of AE event increased with increasing the applied load and many AE event was generated at maximum applied load. Alumina with smaller grain size shows the generation of many AE event resulting in an increase of microcrack formation. An intergranular fracture is predominantly observed in fine-grained alumina whereas intragranular fracture occurs predominantly in coarse-grained alumina,. Analysis of micorstructure and AE prove that primary mi-crocracks occur within grain-boundaries of alumina. The larger microcracking were formed by the growth and/or coalesence of primary microcracks. Then the materials become to fracuture by main crack gen-eration at the maximum applied load.

  • PDF

초음파 파면해석에 의한 대차 프레임의 건전성 평가 (Integrity Evaluation of Bogie Frame by Ultrasonic Fractography Analysis)

  • 윤인식;권성태;선종성;명노종;정우현;손태순;김경국;김순철
    • 한국철도학회논문집
    • /
    • 제3권2호
    • /
    • pp.77-83
    • /
    • 2000
  • This study proposes the integrity evaluation of the bogie frame using ultrasonic fractography analysis. Analysis objectives in this study are to investigate fracture planes of damaged zone by the A-scan method. The surface condition of fracture planes shows degree of degradation by the stress concentration. The detection of the natural defects in the bogie frame is performed using the characteristics of echodynamic pattern in ultrasonic signal. Results of ultrasonic testing agree fairly well with those of actual fracture plane. In quantitative fractography analysis, microstructures of actual fracture plane turned out to be intergranular and transgranular fracture. Proposed ultrasonic fractography analysis in this study can be used for the integrity evaluation of the bogie frame.

  • PDF

비골골절의 비관혈적 정복술 중 사용한 초음파의 유용성 (Usefulness of Ultrasound-Guided Closed Reduction of Nasal Bone Fracture)

  • 이성표;석정훈;최원석;김태범;양완석
    • 대한두개안면성형외과학회지
    • /
    • 제9권1호
    • /
    • pp.12-16
    • /
    • 2008
  • Purpose: Closed reduction is most common treatment method for nasal bone fracture but it requires secondary correction operation commonly. For preventing secondary revision, we applied ultrasonography during closed reduction of nasal bone fracture and examined the result of operation. Methods: 80 patients were sorted into 2 groups, ultrasound-guided closed reduction group(n=40) and manual closed reduction group(n=40). We classified the unilateral fracture involving lower 1/2 of nasal bone into type I, the bilateral fracture involving lower 1/2 of nasal bone into type III and the fracture of upper 1/2 of nasal bone into type III. The occurrence rate of overcorrection and undercorrection were evaluated by comparing preoperative and postoperative MDCT(Multi Direction Computed Tomography). Results: In manual closed reduction group, overcorrection were found in 4 patients and undercorrection were found in 3 patients. In ultrasound-guided closed reduction group, overcorrection was not observed and undercorrection was observed in 2 patients. Conclusion: Intraoperative ultrasound evaluation of nasal bone fracture resulted in reduced occurrence rate of secondary nasal deformities, showed easier detection of the fractured site and have superiority upon simple physical examination or simple x-ray.

Composite Fracture Detection Capabilities of FBG Sensor and AE Sensor

  • Kim, Cheol-Hwan;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • 제27권4호
    • /
    • pp.152-157
    • /
    • 2014
  • Non-destructive testing methods of composite materials are very important for improving material reliability and safety. AE measurement is based on the detection of microscopic surface movements from stress waves in a material during the fracture process. The examination of AE is a useful tool for the sensitive detection and location of active damage in polymer and composite materials. FBG (Fiber Bragg Grating) sensors have attracted much interest owing to the important advantages of optical fiber sensing. Compared to conventional electronic sensors, fiber-optical sensors are known for their high resolution and high accuracy. Furthermore, they offer important advantages such as immunity to electromagnetic interference, and electrically passive operation. In this paper, the crack detection capability of AE (Acoustic Emission) measurement was compared with that of an FBG sensor under tensile testing and buckling test of composite materials. The AE signals of the PVDF sensor were measured and an AE signal analyzer, which had a low pass filter and a resonance filter, was designed and fabricated. Also, the wavelength variation of the FBG sensor was measured and its strain was calculated. Calculated strains were compared with those determined by finite element analysis.

Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

  • Mohammadpour, Mahdis;Bakhshalian, Neema;Shahab, Shahriar;Sadeghi, Shaya;Ataee, Mona;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.89-94
    • /
    • 2014
  • Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts.

Numerical simulation of the femur fracture under static loading

  • El Sallah, Zagane Mohammed;Smail, Benbarek;Abderahmane, Sahli;Bouiadjra, B. Bachir;Boualem, Serier
    • Structural Engineering and Mechanics
    • /
    • 제60권3호
    • /
    • pp.405-412
    • /
    • 2016
  • Bone is a living material with a complex hierarchical structure that gives it remarkable mechanical properties. Bone constantly undergoes mechanical. Its quality and resistance to fracture is constantly changing over time through the process of bone remodeling. Numerical modeling allows the study of the bone mechanical behavior and the prediction of different trauma caused by accidents without expose humans to real tests. The aim of this work is the modeling of the femur fracture under static solicitation to create a numerical model to simulate this element fracture. This modeling will contribute to improve the design of the indoor environment to be better safe for the passengers' transportation means. Results show that vertical loading leads to the femur neck fracture and horizontal loading leads to the fracture of the femur diaphysis. The isotropic consideration of the bone leads to bone fracture by crack propagation but the orthotropic consideration leads to the fragmentation of the bone.

피로골절 환자에서 골주사 소견과 방사선 소견의 비교 (Radioisotopic and Radiological Evaluation in Patient with Stress Fracture)

  • 고광섭;김재영;강성구;김소연;이권전
    • 대한핵의학회지
    • /
    • 제21권1호
    • /
    • pp.39-46
    • /
    • 1987
  • The stress fracture is a disease caused by and abnormal stress to the normal bone with constant, repeated pull. Early detection of stress fracture plays an important role in treatment and prevention of its complication. Bone scintigraphy was performed to evaluate 18 patients with stress fracture of the lower extremities from May, 1985 to April, 1987, in the Department of Internal Medicine of National Police Hospital. The results were as follows: 1) Seventeen of the 18 cases showed positive bone scans at the initial study performed from 1 week to S months after the onset of symtom. 2) Ten of the 18 patients had findings of stress fracture at the initial X-ray film. Two out of 8 negative case revealed positive findings in the follow-up studies. 3) The bone scans in the 2 cases taken 5 months after the onset of symton; the one showed only slightly increased radiouptake, the other showed no abnormal findings. In conclusion, bone scanning is a more sensitive indicator of early stress fracture than radiologic study. The healing phase is characterized by a gradual decline in radioactivity at the fracture site in concordance with subsidence of symptom.

  • PDF