• 제목/요약/키워드: fracture analysis

검색결과 2,997건 처리시간 0.04초

전완 골절 후 도수 정복 시 골절 부위 간격에 따른 골절 인접 연부 조직의 생체역학적 특성 평가: 유한요소해석 (Evaluation of Biomechanical Properties of Fractured Adjacent Soft Tissue Due to Fracture Site Spacing During Closed Reduction After Forearm Fracture: Finite Element Analysis)

  • 박준성;이상현;송찬희;노정훈;이치승
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권5호
    • /
    • pp.308-318
    • /
    • 2022
  • The purpose of this study is to evaluate the biomechanical properties of fractured adjacent soft tissue during closed reduction after forearm fracture using the finite element method. To accomplish this, a finite element (FE) model of the forearm including soft tissue was constructed, and the material properties reported in previous studies were implemented. Based on this, nine finite element models with different fracture types and fracture positions, which are the main parameters, were subjected to finite element analysis under the same load and boundary conditions. The load condition simulated the traction of increasing the fracture site spacing from 0.4 mm to 1.6 mm at intervals of 0.4 mm at the distal end of the radioulnar bone. Through the finite element analysis, the fracture type, fracture location, and displacement were compared and analyzed for the fracture site spacing of the fractured portion and the maximum equivalent stress of the soft tissues adjacent to the fracture(interosseous membrane, muscle, fat, and skin). The results of this study are as follows. The effect of the major parameters on the fracture site spacing of the fractured part is negligible. Also, from the displacement of 1.2 mm, the maximum equivalent stress of the interosseous membrane and muscle adjacent to the fractured bone exceeds the ultimate tensile strength of the material. In addition, it was confirmed that the maximum equivalent stresses of soft tissues(fat, skin) were different in size but similar in trend. As a result, this study was able to numerically confirm the damage to the adjacent soft tissue due to the fracture site spacing during closed reduction of forearm fracture.

고강도 극후판 EH36-TMCP강 EGW용접부의 역학적 거동 및 파괴인성 $K_{IC}$에 관한 해석 (Analysis of Mechanical Behavior and Fracture Toughness $K_{IC}$ on EGW Welded Joints for High Strength EH36-TMCP Ultra Thick Plate)

  • 방희선;방한서;주성민
    • 한국전산구조공학회논문집
    • /
    • 제22권6호
    • /
    • pp.565-572
    • /
    • 2009
  • 본 연구에서는 EGW공정 적용에 따른 고강도 극후판 EH36-TMCP강 용접부의 역학적 거동 및 파괴인성 $K_{IC}$ 특성을 고찰하기 위해 먼저 자체 개발한 열분포, 열탄소성 프로그램을 이용한 유한요소해석을 통하여 용접부의 역학적 거동(용접잔류응력, 소성변형율 등의 크기, 분포, 발생기구)을 규명하였다. 그리고 이때 얻어진 잔류응력을 초기응력으로 하여 상용프로그램 ANSYS에서 노치가공으로 인한 응력 재분포 특성 및 잔류응력과 외력의 복합하중에 대한 파괴인성 KIC를 계산하였다. 균열이 존재하는 EGW용접부의 파괴기준$K_{IC}$를 살펴보면, 중첩된 경우가 순수 외부하중(굽힘하중)만 작용하는 경우 보다 파괴 인성치가 다소 감소하는 경향을 보였다. a/W가 작을 경우 중첩의 경우가 순수 외부하중(굽힘하중)만의 경우보다 파괴인성치 차이가 크나, a/W가 증가함에 따라 그 차이가 점차 없어지는 것으로 나타났다.

전차선로 드로퍼 클램프 파단 원인 분석 (The Cause Analysis on Fracture of Dropper Clamp in Catenary System)

  • 김정남;권성태;강계명
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.909-914
    • /
    • 2004
  • This study investigate the cause analysis on fracture of dropper clamp in catenary system. Dropper clamp is using as a holder between messenger wire and contact wire in catenary system. To analyze the cause analysis on fracture of dropper clamp, we have conducted experiment such as tension withstand strength test, holding strength test of a new products, SEM and EDX of field fractured specimens.

  • PDF

Determination of fracture toughness in concretes containing siliceous fly ash during mode III loading

  • Golewski, Grzegorz Ludwik
    • Structural Engineering and Mechanics
    • /
    • 제62권1호
    • /
    • pp.1-9
    • /
    • 2017
  • This paper describes laboratory tests carried out to evaluate the influence of class F fly ash (FA) on fracture toughness of plain concretes, specified at the third model fracture. Composites with the additives of: 0%, 20% and 30% siliceous FA were analysed. Fracture toughness tests were performed on axial torsional machine MTS 809 Axial/Torsional Test System, using the cylindrical specimens with dimensions of 150/300 mm, having an initial circumferential notch made in the half-height of cylinders. The studies examined effect of FA additive on the critical stress intensity factor $K_{IIIc}$. In order to determine the fracture toughness $K_{IIIc}$ a special device was manufactured.The analysis of the results revealed that a 20% FA additive causes increase in $K_{IIIc}$, while a 30% FA additive causes decrease in fracture toughness. Furthermore, it was observed that the results obtained during fracture toughness tests are convergent with the values of the compression strength tests.

액정 디스플레이(LCD)의 패널유리 파손평가에 관한 연구 (Analysis on the Fracture of a Panel Glass in a Liquid Crystal Display Module under Mechanical Shock)

  • 박상후;이부윤;엄윤용
    • 한국정밀공학회지
    • /
    • 제17권12호
    • /
    • pp.76-81
    • /
    • 2000
  • Analysis on failure of the panel glass under mechanical shock is the main topic of this study. Since the glass for the LCD panel is thin, it needs to be designed to have enough toughness against mechanical shock. In this paper, a process of estimating fracture of the panel glass is proposed to guarantee reliability of the product. The fracture toughness of the panel glass is used as a criterion of the fracture based on an experimental approach. The stress intensity factor was calculated considering a model with the largest initial crack size on a cut surface and with the boundary force obtained from a dynamic finite element analysis. Critical surface roughness on the cut surface of a typical glass panel, to prevent fracture in case of bending mode, is obtained.

  • PDF

척추성형술 시술에서 요추의 생체역학적 특성 변화 (Biomechanical Property Change of Vertebral body in Vertebroplasty)

  • 이준형;전성재;채수원;이태수;서중근;박정율;김상돈;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1324-1327
    • /
    • 2003
  • The compressed fracture of spine caused by osteoporosis is one of the most frequent diseases in bone fracture. Recently the vertebroplasty has drawn much attention as a medical treatment for the compressed fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. The finite element analysis is used to investigate the vertebroplasty quantitatively. Previous works with finite element analysis have drawbacks in their simplified models geometry of vertebral body and with material properties of bone. In this paper the exact geometry of vertebral body has been constructed from medical image data and the biomechanical property changes of vertebral body in vertebroplasty have been investigate by using three dimensional finite element analysis.

  • PDF

3-way 초고압 밸브의 유로제어를 위한 니플 파단 특성에 관한 연구 (Study on Characteristics of Nipple Fracture for Fluid Path Control of 3-Way Ultra-High Pressure Valve)

  • 강대희;;정윤재;김원태
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.865-871
    • /
    • 2018
  • The 3-way valve have been used as a valve for opening and closing the valve by the flow control in the pressure system of the cryogenic and high pressure environment. In this paper, numerical analysis and experimental study on fracture nipple of 3-way ultra high pressure valve applied to space launch vehicle was carried out. We have developed a 3-way valve numerical simulation modeler of cryogenic environment using commercial software ANSYS 18.2. As results of numerical analysis, optimum nipple condition was derived. In addition, a 3-way valve prototype was fabricated and the fracture test was performed and compared with the numerical analysis results.

변형률 측정을 이용한 추진기관용 Al 합금의 파괴인성 평가 (Evaluation of Fracture Toughness of Al alloys for Propulsive Engine using Strain Measurement)

  • 김재훈;김덕회;임동규;박성욱;문순일
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.13-21
    • /
    • 2002
  • The tincture toughness is evaluated by using U(compact tension) and 3PB(three point bending) specimens of AI alloys far propulsive engine. To evaluate the static fracture toughness, strain gage method is used. The static fracture toughness obtained from the strain measurement is compared with the results by ASTM standard and FEM analysis. For the reliable evaluation of fracture toughness, strain gages are attached at various positions.

A comparative evaluation of fracture resistance of endodontically treated teeth restored with different post core systems - an in-vitro study

  • Makade, Chetana S.;Meshram, Ganesh K.;Warhadpande, Manjusha;Patil, Pravinkumar G.
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.90-95
    • /
    • 2011
  • PURPOSE. To compare the fracture resistance and the mode of failure of endodontically treated teeth restored with different post-core systems. MATERIALS AND METHODS. Root canal treatment was performed on 40 maxillary incisors and the samples were divided into four groups of 10 each. For three experimental groups post space preparation was done and teeth were restored with cast post-core (Group B), stainless steel post with composite core (Group C) and glass fiber post with composite core using adhesive resin cement (Group D). Control group (A) samples were selected with intact coronal structure. All the samples were prepared for ideal abutment preparation. All the samples were subjected to a load of 0.5 mm/min at $130^{circ}$.until fracture occurred using the universal testing machine. The fracture resistance was measured and the data were analyzed statistically. The fracture above the embedded resin was considered to be favorable and the fracture below the level was considered as unfavorable. The statistical analysis of fracture resistance between different groups was carried out with t-test. For the mode of failure the statistical analysis was carried out by Kruskal-Wallis test and Chi-Square test. RESULTS. For experimental group Vs control group the fracture resistance values showed significant differences (P<.05). For the mode of failure the chi-square value is 16.1610, which means highly significant (P=.0009) statistically. CONCLUSION. Endodontically treated teeth without post core system showed the least fracture resistance demonstrating the need to reinforce the tooth. Stainless steel post with composite core showed the highest fracture resistance among all the experimental groups. Teeth restored with the Glass fiber post showed the most favorable fractures making them more amenable to the re-treatment.

노인과 중년 당뇨병 환자의 골절의 발생 빈도 위험과 혈당조절의 관계 (Risk of Fracture Prevalence and Glycemic Control in Korean Older and Middle-aged Patients with Diabetes: A Retrospective Analysis of a Cohort Derived from the Korean National Health Insurance Sharing Service Database, 2009-2013)

  • 신혜연
    • 한국임상약학회지
    • /
    • 제28권3호
    • /
    • pp.194-203
    • /
    • 2018
  • Background: Bone fractures are high in elderly patients with type 2 diabetes mellitus (T2DM). Hyperglycemia and chronic kidney disease may increase the risk of fracture prevalence via altered bone metabolism, but whether glycemic control and kidney function are associated with the risk of fracture prevalence remains unclear. This study evaluated the relationship between glycemic control and baseline estimated glomerular filtration rate (eGFR) and risk of fracture prevalence in older and middle-aged patients with T2DM. Methods: Patients who underwent a general medical check-up between 2009 and 2013 were selected from the Korean National Health Insurance Sharing Service records. Chi-square test and multiple logistic regression analysis were used to assess the relationship between glycemic control and eGFR and risk of fracture prevalence. Results: Cumulative fracture prevalence were higher in patients with T2DM, irrespective of whether they had tight or less stringent glycemic control (fasting blood glucose [FBG] ${\geq}110mg/dL$). After adjustment for baseline age and FBG, tight and less stringent glycemic control was significantly associated with increased adjusted risk of fracture prevalence in middle-aged patients with T2DM (OR=1.13, 95% CI, 1.05-1.21, p=0.0005 vs OR=1.13, 95% CI, 1.06-1.20, p=0.0001), but not in older patients. Baseline eGFR was not significantly related to fracture prevalence in either older or middle-aged patients. Conclusion: Less stringent glycemic control significantly increased the adjusted risk of fracture prevalence in middle-aged patients with T2DM. Further studies are needed to confirm the effect of tight glycemic control on fracture prevalence.