• Title/Summary/Keyword: fourier-spectrum

Search Result 476, Processing Time 0.028 seconds

Measuring Technique of Burn-out Indices for 2.75″ Rocket Motor (2.75인치 로켓트 모터의 연소완료지표 계측기법)

  • Kang, Kyu-Chang;Choi, Ju-Ho;Yu, Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.106-115
    • /
    • 2000
  • This paper presents the measuring technique of time and velocity when rocket motor is burnt out for 2.751" rocket. This technique use doppler effect, frequency spectrum analysis and curve fitting. In this study, we use muzzle velocity radar for doppler signal acquisition, short-time fourier transform for spectrum analysis and curve fitting for smoothing.

  • PDF

Electron Beam Welding Diagnosis Using Wavelet Transform (웨이브렛 변환을 이용한 전자빔 용접 진단)

  • 윤충섭
    • Journal of Welding and Joining
    • /
    • v.21 no.6
    • /
    • pp.33-39
    • /
    • 2003
  • Wavelet transform analysis results show a spectrum energy distribution of CWT along scale factors distinguish the partial, full and over penetration in a electron beam welding by analyzing the curve of spectrum energy at small scale, middle and large scale range, respectively. Two types of signals collected by Ion collector and x-ray sensors and analyzed. The acquired signals from sensors are very complicated since these signals are very closely related the dynamics of keyhole which interact the very high density energy with materials during welding. The results show the wavelet transform is more effective to diagnosis than Fourier Transform, further for the general welding defects which are not a periodic based, but a transient, non-stationary and time-varying phenomena.

Sound Intensity Estimation with the Effect of Leakage Error from the Contaminated Data (누설오차의 영향을 고려한 음향 인텐시티의 추정)

  • 안세진;정의봉;정호경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1189-1194
    • /
    • 2002
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent micrphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional r]n analyzer will show distorted value. In this paper the expression of the Fourier transformed data of a harmonic signal is formulated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

Spectra of nonlinear shallow water waves (비선형 천해파의 스펙트라)

  • Zahibo, Narcisse;Didenkulova, Ira;Pelinovsky, Efim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.4
    • /
    • pp.355-360
    • /
    • 2007
  • The process of the nonlinear shallow water wave transformation in a basin of a constant depth is studied. Characteristics of the first breaking of the wave are analyzed in details. The Fourier spectrum and steepness of the nonlinear wave are calculated. It is shown that the spectral amplitudes can be expressed using the wave front steepness, which allows the practical estimations.

A Study of Biosignal Analysis System for Sensibility Evaluation (감성을 평가하기 위한 생체신호 분석 시스템에 관한 연구)

  • Lee, Ji-Hyeoung;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.35-38
    • /
    • 2010
  • 본 논문에서는 일상생활 속에서 무자각적으로 생체신호를 측정하고 분석하여 감성을 평가할 수 있는 임베디드 시스템에 관하여 연구하였다. 지속적으로 변화하는 감성을 일관적이며 신뢰성이 높은 생리적인 방법으로 평가하기 위해 심전도(ECG:Electrocardiogram), 맥파(PPG:Photoplethysmogram)의 두 가지 생체신호를 측정하고, 무선전송(Bluetooth) 장치를 이용하여 측정한 생체신호를 실시간으로 노트북PC로 전송하여 분석하였다. 생체신호의 분석방법은 FFT(Fast Fourier Transform)과 전력스펙트럼밀도(Power Spectrum Density)를 이용한 주파수 분석방법으로 두 생체신호의 특정 주파수 대역이 가지는 자율신경계의 활성도의 비율을 분석하여 비교 연구하였다. 또한 보다 빠르고 정확한 감성을 평가하기 위하여 분석알고리즘의 연산을 최소화 하였으며 그래프를 이용한 분석결과의 시각화를 하였다. 본 논문에서는 무자각적인 생체신호 측정 시스템을 이용하여 다양한 상황에서 생체신호를 측정하고, 개발한 분석 알고리즘으로 분석한 결과의 차이를 연구하여 정확도 및 신뢰도를 기준으로 감성을 평가하기 위한 분석 시스템을 평가하였다.

  • PDF

The Texture Classification of Liver Parenchyma Using the Fractal Dimension and the Fourier Power Spectrum (프랙탈 차원과 퓨리에 파워스펙트럼을 이용한 간조직 분류)

  • Jeong, Jeong-Won;Kim, Dong-Youn
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.37-41
    • /
    • 1995
  • In this paper, we proposed the 2-stage ultrasound liver image classifier which uses the fractal dimensions obtained from the original image and its 1/2 subsampled image, and the Normalized Fourier Power Spectrum. The fractal dimension based on Fractional Brownian Motion (FBM) is calculated from the variance of the same scale pixels instead of the mean of them. Since the actual ultrasound. liver images does not fully match the FBM, to get the fractal dimension, we use the scale vectors which satisfy the FBM model. In 2-stage classifier, we first classified normal and diffuse liver and then classified the fat liver and cirrhosis from the diffuse liver. For the test liver images. 70% of normal liver and 80% of fat liver and 90% of cirrhosis is classified classified with our 2-stage classifier.

  • PDF

Leakage Error Improvement of the Intensity with a single freqency (단일 주파수를 갖는 음향 인텐시티의 누설오차 개선)

  • 정의봉;안세진;정호경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1156-1161
    • /
    • 2001
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed date of a harmonic signal with a single frequency is formated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

Energy Spectrum of Underwater Explosive Sound (수중 폭발음의 에너지 스펙트럼)

  • Kim, Sung-Boo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.56-61
    • /
    • 1990
  • A New theoretical energy spectrum model for underwater explosive sound is introduced in order to calculate the precise spectral energy levels. This model is obtained by Fourier analysis of Gaussian formula which accurately represents the pressure wave generated from Underwater explosions. In case that explosive energy is very low. The spectrum levels which are obtained from the new theoretical model are in good agreement with the experimental spectrum levels, while the Weston model using impulse formula cannot interpret the experimental results.

  • PDF

Feature Extraction of Fault Current using Fourier Transform in the Multi-Shot Reclosing Scheme (푸리에 변환을 이용한 다중 재폐로방식에서의 사고전류 특징 추출)

  • O, Jeong-Hwan;Yun, Sang-Yun;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.50-55
    • /
    • 2000
  • This paper presents the feature extraction of fault currents related to the multi-shot reclosing scheme in the power distribution system. In order to get the fault current waveform, we have measured the fault currents by the fault recorders which have been installed at the secondary side of 154/22.9[kV] substation transformer. These waveforms are classified into temporary and permanent fault. For the classified waveforms, Fourier transform is used to extract the feature of the fault current waveforms. After the waveforms are analyzed by using Fourier transform, the magnitude spectrum and the relative variation of THD (Total Harmonic Distortion) are calculated. And then the relative variation of THD is great in the temporary faults, and is small in the permanent faults.

  • PDF

Stamping Tool Wearing Analysis by Time-Frequency Analysis (시간-주파수 분석에 의한 금형 마모 분석)

  • Lee, Chang-Hee;Han, Ho-Young;Seo, Geun-Seok;Kim, Yong-Yun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.3
    • /
    • pp.407-413
    • /
    • 2010
  • This paper reports on the research which analyzes acoustic signals acquired in progressive compressing, hole blanking, and burr compacting process. An acoustic sensor was set on the bed of hydraulic press. Acoustic signal is generated from progressive stamping process. First the signal acquired from the unit process; compressing, blanking or compacting, is studied by Fourier Transform and Short Time Fourier Transform. The blanking process emitted ultrasonic signal with more than 20kHz, but the compressing and compacting processes emitted acoustic signals with lower than 10kHz. The combined signals periodically acquired right after the tool grinding were then analyzed. 70-80kHz signals appeared in time-frequency domain, but not in the frequency domain, the magnitude of which was related to the tool wear. Short Time Fourier Transform made up for the Fourier Transform in analyzing the emitted signal for stamping process in the ultrasonic domain.