• 제목/요약/키워드: forest fire area

검색결과 303건 처리시간 0.025초

산불예방을 위한 감시시설 가시범위 분석에 관한 연구 (Analysis on Visibility Range of Forest Fire Detection Facilities for Forest Fire Prevention)

  • 이시영;안상현
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.157-160
    • /
    • 2008
  • This study analyzed on the area of Samcheok, Kangwondo about forest fire alarming area and enlargement of the area. Then, visible area by unattended watching camera and watchtower for forest fire which were run by Samcheok was cross-checked with geographic information system, and it could be whether effective on watching the area where the forest fire risk was high enough and also it could be expanded to larger forest fire. The result of study, the visible area by watching facilities only holds for 13.4% of the whole forest fire alarming area, but the forest fire can be observed even though it is occurred in small valley because of smoke and all the forest fire have been occurred in daytime. Therefore, it can be determined that watching area will be extended around 50.3% while the observation radii of watching facilities raise by 4km. However, Samcheok has much greater area of mountain area in compared to any other cities or counties, watching facilities should be installed and run additionally for extinguishing the forest fire from the beginning.

  • PDF

산불피해지역에서 숲 가꾸기 실행유무가 산불에 미치는 영향 (Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area)

  • 이시영;이명욱;염찬호;권춘근
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.153-156
    • /
    • 2008
  • Comparative analysis of forest fire danger rating on the forest characteristics of thinning area and non-thinning area on forest fire burnt area was studied in this work. To investigate the effect of thinning slash in forest fire, Gangneung-si Wangsan-myeon, Ulgin-gun Wonnam-Myeon, Samchok-si Gagok-Myeon, in which forest fire broke out, were selected. As a result that investigated forest fire danger ratio between thinning slash and non-thinning slash, leeward scorching ratio(36%), crown damage ratio(29%), mortality of branch at the former are higher than those at the latter, leeward scorching ratio of tree, where thinning slash is around, is 10%-20% higher than that of independent tree. So I estimate that thinning slash has a some effect on the intensity of forest fire. And the result to investigate damage of forest fire according to tree species shows that leeward scorching ratio of conifer is 5% higher than that of non-conifer, and mortality of branch of the former is 19% higher than that of the latter. It is considered that forest fire may affect directly to a tree trunk if it diffuse to piled thinning tree because there was no space between thinning trees and trees. Furthermore, it was found that re-ignition had a chance to occur due to lots of piled thinning trees.

  • PDF

삼척지역 산불위험지 구분에 따른 감시시설의 위치 적합성에 관한 연구 (Analysis on a Location Compatibility of Forest Fire Detection Facilities according to Classification of Forest Fire Hazard Regions Types in Samcheok Area)

  • 이시영;안상현
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.265-271
    • /
    • 2008
  • 본 연구는 강원도 삼척시 지역을 대상으로 산불발생 위험지역과 대형화 위험지역을 분석하고, 현재 삼척시에서 운영하고 있는 산불무인감시카메라 및 산불감시탑의 가시권역을 GIS 중첩분석을 통하여 산불발생위험이 높으면서도 대형 산불로 확대될 위험이 높은 지역을 효과적으로 감시하는지의 여부를 분석하였다. 연구결과 산불위험지역 중 가시권 범위에 들어오는 지역은 13.4% 정도밖에 되지 않았지만, 산불이 주로 낮에 발생하고, 연기가 나기 때문에 조그만 계곡부에서 발생하더라도 감시 할 수 있으므로 감시시설 반경을 4km까지 포함하면 전체면적 중 약 50.3%를 감시할 수 있을 것으로 판단되었다. 그러나 삼척시는 다른 시,군에 비해 넓은 면적의 산림을 가지고 있어 초동진화를 위해서는 감시시설을 추가적으로 설치 운영할 필요가 있다.

숲 가꾸기 실행 및 미실행지의 임분특성에 따른 산불위험도 분석 (Analysis of forest fire danger rating on the forest characteristic of thinning area and non-thinning area)

  • 이시영;이명욱;채희문;원명수;염찬호
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.217-222
    • /
    • 2007
  • Since 1973, we attain a successful achievement of nation-wide afforestation such as a thick forest and heaped-up leaves. However, the higher of the formation density in forest, the more dangerous to be a large-scale forest fire whenever fire occurs. According to the type of forest in the country, 42% of the forest is occupied by conifer forest that are highly flammable, and the distribution of forest age is in a transition period from immature forest to mature one. And the structure is too weak to the forest fire for the occurrence and spread because there are too many scrub and shrub trees in the forest. As a matter of course, it is on the increase of the thinning-forest that can shift the forest structure from a weak on forest fire to a strong one nowaday. In other words, thinning-forest has primary purposes such as the promotion of producing forest trees, production of excellent timbers, and build-up of public forest area. Furthermore, in some reports, the reduction of ladder fuel by eliminating the vertical/horizontal fuel in a forest and ensuring spaces in the forest can decrease the occurrence of forest fire and the risk of spread of burning as by-effect. Therefore, this study is designed to clarify the relation with the risk of forest fire by an on-spat-investigation of the characteristics of forest composition on the thinning and the non-thinning area.

  • PDF

산불피해지역 연료형태가 산불연소에 미치는 영향 (Influence on forest fire spread & intensity on fuel type of burnt area.)

  • 이시영;이명욱;염찬호;권춘근;박흥석;이해평
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.321-324
    • /
    • 2008
  • Forest fire danger rate of thinning area was lower than that of non thinning area, because height rate of leewardside in burned stem of tree, damage rate of crown and mortality of tree in thinning area were 30.8%, 37% and 48.4% lower than that in non-thinning area, respectively. Intensity of forest fire varied depending upon topographical condition up slope, down slope, aspect, location as well as species, breast height diameter and forest tree density. Especially, a mountaintop area was burned down when forest fire was spread to up slope ridge of mountain.

  • PDF

1991년부터 2007년까지 산불의 공간적 특성 (Spatial Patterns of Forest Fires between 1991 and 2007)

  • 이병두;이명보
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.15-20
    • /
    • 2009
  • 산불을 효율적으로 관리하기 위해서는 지역별 산불 행동 특성에 대한 이해가 요구된다. 본 논문에서는 전국 시 군 구 단위고 산불통계 자료를 이용하여 발생 및 확산 특성을 분석하였다. 이를 위해 1991년 부터 2007년까지 17년간 발생건수, 연소면적, 확산속도, 건당 면적 자료를 이용하여 산불 특성에 따라 군집을 분류하고 GIS를 이용하여 공간적 분포 특성을 분석하였다 분석결과, 산불의 공간적 특성 변이가 뚜렷하게 관찰되었고, 전국 시 군 구는 산불위험성에 따라 5개의 군집으로 분류할 수 있었다. 대도시와 인근 지역은 산불위험이 낮은 군집으로 분류되었으나, 강원도 영동지방 4개 시 군은 가장 위험한 군집으로 분류되었다. 그 뒤를 이어 남, 서해안에 인접한 시 군 구의 산불위험성이 높았다.

디지털 사진을 이용한 산불 피해 조사 방안 (A Plan for Estimation of Damaged Area from Forest Fire Using Digital Photographs)

  • 정수
    • 대한공간정보학회지
    • /
    • 제18권4호
    • /
    • pp.41-50
    • /
    • 2010
  • 우리나라는 국토에서 산림이 차지하는 비율이 매우 높기 때문에 산불은 방재에 있어서 중요한 요소로 취급된다. 산불 피해 면적 산정은 향후 복원계획을 수립함에 있어서 예산 수립이나 물량 산출에 기초가 되는 중요한 자료이므로 정확하게 산정되어야 한다. 우리나라에서는 산불이 발생되면 GPS를 이용하여 피해 면적을 조사하고 있다. 그러나 실제 산불 피해 면적을 산정하는 데 있어서는 여러 가지 문제로 인하여 신속하고 정확한 산정이 잘 이루어지지 않고 있다. 우리나라의 산불 담당 기관인 산림청은 전국을 대상으로 하여 충분한 수의 산림 헬리콥터를 운용하고 있다. 따라서 산불 피해가 발생한 후에 산림 헬리콥터를 이용하여 피해지역을 디지털 카메라로 사진 촬영하는 것이 가능할 것이다. 본 연구에서는, 공중에서 디지털 카메라로 스냅 촬영한 산불 피해 지역 사진을 이용하여 그 피해 조사를 수행할 수 있도록, 여러 가지 처리 방법을 비교 고찰함으로써 적합한 방안을 정립하였다. 본 연구의 결과는 향후에 디지털 사진을 이용한 산불 피해 조사 시스템 개발에 유용하게 활용될 수 있을 것이다.

가시권 분석을 이용한 산불감시 우선지역 선정 방안 (Development of Algorithm for Analyzing Priority Area of Forest Fire Surveillance Using Viewshed Analysis)

  • 이병두;유계선;김선영;김경하;이명보
    • 한국지리정보학회지
    • /
    • 제14권3호
    • /
    • pp.126-135
    • /
    • 2011
  • 산불 감시 시설의 탐지확률을 높이고, 감시 자원의 운영 효율성을 높이기 위해서는 어디를 감시해야 하는가에 대한 사전 분석이 요구된다. 본 연구에서는 산불 감시 우선지역을 기존 감시 시설의 가시권과 해당 지역의 산불발생 확률 분석 결과를 이용하여 선정하는 방안을 제시하였다. 즉 발생 확률이 높으면서, 가시성이 떨어지는 곳을 우선 감시 지역으로 정의하고, 퍼지함수를 이용한 변환과 가중치 부여에 의한 중첩분석을 통해 산불감시 우선지도를 생성하였다. 봉화지역을 대상으로 분석한 결과, 감시 우선 지역은 산지가 많은 북부 지역보다는 인구가 많은 중남부 지역에 많이 분포하였다. 개발된 산불감시 우선지역 분석 체계는 한정된 감시 자원의 적정 배치 위치를 선정하는데 기여할 수 있을 것으로 예상된다.

숲 가꾸기 실행 및 미 실행지의 임분특성에 따른 산불위험성 비교분석 (Comparative Analysis of Forest Fire Danger Rating on the Forest Characteristics of Thinning Area and Non-thinning Area)

  • 이시영;이명욱
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.52-58
    • /
    • 2007
  • 본 연구는 숲 가꾸기 실행지와 미실행지의 임분 특성이 산불에 미치는 영향에 관한 연구이다. 조사지역은 강원도 양양군, 인제군 그리고 경기도 가평군 등 3개 군에서 14개소를 선정하였으며, 이중 숲 가꾸기 실행지 9개소, 미실행지의 5개소에 대한 현장조사를 실시하였다. 현장조사를 통해 임목의 수고, 흉고직경, 지하고, 죽은 가지 고사율, 임목밀도, 울폐도, 관목층 및 초본층 피도를 조사하였으며 이 자료를 통해 숲 가꾸기 실행 및 미실행지의 임내특성분석을 실시하였다. 또한 임내특성 분석으로부터 산불발생 및 확산 위험성과의 관계를 분석하였다. 숲 가꾸기 실행지역과 미실행지역의 임분 특성조사 결과 숲 가꾸기 실행지역이 미실행지역에 비해 상대적으로 평균 지하고는 높았고, 임목본수는 적었으며, 죽은 가지 고사율은 적었고, 초본층 피도는 높게 나타나고 있어 숲 가꾸기 실행지역의 산불위험도는 미실행지역보다 낮아질 것으로 판단되었다.

농촌 주거지역 쓰레기소각으로 인한 산불화재 개선방안에 관한 연구 (A Study on the Improvement Method of Forest Fire Caused by Waste Incineration at the Farming Residential Area)

  • 이영삼
    • 대한안전경영과학회지
    • /
    • 제18권3호
    • /
    • pp.9-15
    • /
    • 2016
  • Currently the forest area is 6,370,000 hectare (ha) which occupies 63.7% in Korea. The forest has good functions such as production of forest products, conservation of national land, prevention of disasters, etc. However constructing houses near the forest area make bad situation like illegal waste incineration by resident. So research subject is forest fire caused by waste incineration place including facility. And this study was conducted about statistical analysis and research analysis of the 100 waste incineration places including facilities at the country town. Statistical analysis shows that March is 27% which percentage is the highest number of forest fire in 10 years' average. The number of forest fire caused by waste incineration is 45 which is the third highest number in the fire statistic. The distance between waste incineration place including facility and forest area is 30m, 40m and 50m. That 40m (36%) is the most common distance from forest area. The types of waste incineration are ground (62%), the temporary facility made with oil drum can (35%) and other made with steel sheet, concrete, etc. The result of this study is that government and local government must conduct the improvement measure to reduce illegal incineration such as waste pickup area made with rain and wind proof type installed near residence, expenses for waste treatment, enlightenment and training, etc. Also considering their age and income are needed for realistic improvement.