• 제목/요약/키워드: forced-ventilation

검색결과 142건 처리시간 0.033초

자연 및 강제 배기시의 터널 내 연기거동에 관한 실험적 연구 (An Experimental Study of Smoke Movement in Tunnel Fire with Natural and Forced Ventilations)

  • 황철홍;유병훈;금성민;김정엽;신현준;이창언
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.711-721
    • /
    • 2005
  • In order to design of emergency ventilation systems, the smoke movements in tunnel fire with natural and forced ventilation were investigated. Reduced-scale experiments were carried out under the Froude scaling with novel fire source consisting many wicks. Temperature profiles were measured under the ceiling and vertical direction along the center of the tunnel and poisonous gases were measured at emergency exit point in the natural ventilation case. In forced ventilation, temperature profiles were measured with various flow rate to obtain critical velocity. The results showed that the interval of emergency exit having 225m was estimated reasonably through the measurements of temperature variation and poisonous gas in the natural ventilation. In the case of forced ventilation, the temperature distribution near fire source is remarkably different from that of natural ventilation. Also, the critical velocity to prevent upstream smoke flow has the range of 0.57m/s between 0.64m/s. Finally, it was also identified that although the increase of flow rate can suppress the backward flow of smoke to upstream direction, brings about the increase of flame intensity near stoichiometric fuel/air ratio.

강제환기를 이용한 하절기 군 저장시설의 표면결로 방지에 관한 연구 (Forced Ventilation Method for Preventing Surface Condensation of Magazine of Igloo type in Summer)

  • 박선효;윤성도;손장열
    • KIEAE Journal
    • /
    • 제10권2호
    • /
    • pp.57-62
    • /
    • 2010
  • In case of earth-covered storage, the condensation occurs on surface of wall and stores in summer with high humidity because of low temperature of constructional mass. Therefore, the preventive plans should be considered to protect stores from the damage by corrosion in earth-covered storages. This study aims to suggest the methods of forced ventilation by the air, to solve the problems of construction's surface condensation at the Magazine of igloo type which is similar to earth-covered storages. A fan was installed at the air outlet for exhaust gas to conduct forced ventilation. The surface and indoor temperature were measured, and then the influence of those on condensation was analyzed. The results of this research are follows; 1) Forced ventilation by a fan affects the rise in surface temperature of walls and stores. 2) The condensation on surface of walls and stores was reduced after operating a fan.

강제배기를 수반한 자동차 실내의 환기시스템에 대한 유동 및 열전달 해석 (Flow and Heat Transfer Analysis for the Ventilating System in Automobile Interior with a Forced Exhaust)

  • 이상호;모정하
    • 대한기계학회논문집B
    • /
    • 제29권4호
    • /
    • pp.469-476
    • /
    • 2005
  • Numerical modeling has been carried out to investigate the two-dimensional air flow in automobile interior with a forced exhaust close to main air inlet for typical ventilation modes. The characteristics such as streamlines and temperature fields in the passenger compartment room with the forced exhaust are analyzed with comparison of the cases without a forced exhaust. The simulation results show that air flow on the floor near the front seat is increased with the forced exhaust for all ventilation modes. Flow recirculation in the cabin is most active in mode 2 with a vertical suction inlet in comparison with other two modes. In particular, less time is taken for air temperature to reach the inlet temperature due to the forced exhaust for the ventilation modes. Finally, it could be predicted that ventilating air flow is much improved with the forced exhaust in the interior Modeling results in this study can be applied to the optimal design of automobile interior fur air ventilation system.

환기처리에 의한 수박의 시듦증 발생 기작 (Wilted Symptom in Watermelon Plant under Ventilation Systems)

  • 조일환;안중훈;이우문;문지혜;이주현;최병순;손선혜;최은영;이상규;우영회
    • 원예과학기술지
    • /
    • 제28권4호
    • /
    • pp.529-534
    • /
    • 2010
  • 수박($Citrullus$ $lanatus$ L.)의 시듦증은 생리장해라고 알려져 있다. 품질 및 수량을 저하시키고 큰 경제적 손실을 가져오는 이 증상은 주로 한국의 수박 주산지인 의령이나 함안 지역에서 기온이 높아지는 3월 중순 이후부터 시작하며 해에 따라 발생 양상이 차이가 있다. 수박 생리장해에 대한 많은 연구가 수행되고 있으나 시듦증의 발생 기작에 대한 연구는 미흡한 실정이다. 본 연구는 시듦증 발생 기작을 해명하기 위하여 강제환기 처리를 하였으며 경남 의령군 용덕면에서 2009년 1월-5월까지 수행하였다. 관행처리에 비해 강제환기 처리는 시설내 기온, 엽온 및 근권부의 온도를 각각 약 4.5, 5, $3^{\circ}C$정도 낮게 유지시켰고 포차도 낮게 유지시켰다. 전 생육기간 동안 관행 및 강제환기 처리 모두에서 과실 생육속도가 최대를 보이는 시기가 두 차례 관찰되었고 관행에서 그 속도와 시기가 더 빠른 것으로 관찰되었고, 첫 번째 최대기는 착과 후 12일에(350g/일), 그 두 번째는 착과 후 24일에(350g/일) 관찰되었다. 시듦증은 착과 후 22일에 관행처리 에서만 발생하기 시작하였다. 강제환기 처리에서 과실 생육최대기는 관행처리에서 보다 4일 늦게 관찰되었다(350g/일). 동시에 식물체 생육속도도 강제환기가 관행처리 보다 낮은 것으로 나타났다. 이러한 결과들은 강제환기가 전 생육기간 동안 엽온 및 포차를 낮게 유지함으로써 식물체 및 과실의 생육속도를 조절했다는 것을 보여준다. 따라서 강제환기가 건전한 생육을 유도하고 식물체의 증산을 조절함으로써 엽과 과실간 수분경합을 줄여 시듦증을 방지시킨다는 가설을 제시한다. 금후 직접적이고 정밀한 실험을 통해 강제환기효과에 대한 식물체내의 수분균형의 연구가 기대 된다.

시험공간에 강제환기를 고려한 냉방부하의 실증실험 및 시뮬레이션 (Verification Experiment and Simulation of Cooling Load for a Test Space with Forced Ventilation)

  • 김동혁;유호선;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.217-222
    • /
    • 2005
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8:30 to 21:00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual cooling loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Cooling loads including sensible and latent were compared between by experiment and by simulation. Both of cooling loads associated with ventilation show a close agreement within an engineering tolerance.

  • PDF

HRSG건물 온도제어를 위한 환기방안에 관한 수치적 연구 (Numerical Study on Ventilation Method for Temperature Control of HRSG Building)

  • 김철환;이종욱;최훈기;유근종
    • 한국산업보건학회지
    • /
    • 제19권3호
    • /
    • pp.240-249
    • /
    • 2009
  • HRSG(Heat Recovery Steam Generator) building is large enclosed structure included various heat sources. This building needs to appropriately keep internal air temperature for worker's safety and operability of control devices. In this study, ventilation analysis is performed to find proper ventilation method for temperature control. Ventilation analysis is applied to entire internal space of the building with standard $k-{\varepsilon}$ model and enhanced wall treatment because of large size of the structure. And the ventilation method is considered natural and forced convection with two louver structures which has damper or not. Louver structure affect directly air circulation in near HRSG and lower region of the building. Forced ventilation provides strong inertial force which cause upward airflow. From the analysis, it is found that design requirement for internal air temperature can be satisfied by forced ventilation method with louver structure without damper.

공연장 무대 화재 시 방화막과 강제 배연구가 객석으로의 연기 확산에 미치는 영향 (Effects of Fire Curtain and Forced Smoke Ventilation on Smoke Spread to Auditorium in Stage Fire of Theater)

  • 김재한;김동균;이치영
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.28-36
    • /
    • 2017
  • 본 논문에서는 공연장 무대 화재 시 객석으로의 연기 확산에 방화막 및 강제 배연구가 미치는 영향에 대하여 Fire Dynamics Simulator (FDS)를 이용하여 연구를 수행하였다. 폭 31 m, 깊이 34 m, 높이 32 m의 무대에 대하여, 10 MW의 열방출률과 화재성장속도가 fast인 화재를 적용하였다. 강제 배출량은 화재안전기준과 기존 연구를 토대로 설정하였으며, 방화막과 프로시니움 (Proscenium) 벽 사이 간격은 0 m, 0.5 m인 경우를 대상으로 하였다. 방화막과 프로시니움 벽이 완벽하게 밀착되어 있는 경우, 강제 배연구와는 상관없이 객석으로의 연기 확산은 일어나지 않았다. 방화막과 프로시니움 벽 사이의 간격이 0.5 m인 경우, 방화막이 없는 경우에 비해 무대 공간 내에서 연기층이 더욱 낮은 높이까지 하강하였으며, 이는 방화막에 의해 객석으로의 연기 확산이 방해받았기 때문이다. 한편, 동일한 방화막 조건에서, 강제 배연구가 있는 경우가 없는 경우에 비해 방화막과 프로시니움 벽 사이 간격을 통한 유출 질량유량이 작았다. 본 연구를 통하여 방화막과 강제 배연구가 공연장 무대 화재 시 객석으로의 연기 확산을 억제할 수 있는 효과적인 방법임을 확인하였다.

여름철 유리온실의 목표온도 유지를 위한 강제환기 회수 (Forced Ventilation Number of Air Changes to Set Point of Inside Air Temperature in Summer Glasshouse)

  • 우영회;이정명;남윤일
    • 생물환경조절학회지
    • /
    • 제4권2호
    • /
    • pp.223-231
    • /
    • 1995
  • 여름철 온실 온도환경의 효율적인 제어는 온실의 주년재배와 고도활용을 위한 가장 중요한 당면과제이다. 따라서 본 연구는 우리나라 31개 지역의 기후자료를 분석하여 고온기 온실의 기온관리에 있어서 목표 온도 유지를 위한 지역별 적정 최대환기횟수를 결정함으로서 온실의 기온관리를 위한 기본적인 자료를 제공하고자 실시하였다. 그 결과 여름철 유리온실의 설정온도 유지를 위한 강제환기는 40% 차광 유리 온실에서 최대환기횟수 1회/min로 35$^{\circ}C$ 유지가 가능하였으나 환기만에 의한 한계 최고실온 3$0^{\circ}C$ 유지는 불가능하였다.

  • PDF

지하 전력구 터널의 환기시스템 적용에 관한 연구 (II) (A Study for Application Ventilation System of Underground cable Tunnel (II))

  • 김경열;오기대;김대홍;김종환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.778-783
    • /
    • 2008
  • In this paper, numerical method was calculated on evaluation of underground ventilation system to keep servicing a fresh air. The tunnel length for simulation is 18.2 km with various located seven ventilation shaft. Generally, owing to thermal generation in cable tunnel under about 50 m depths, cable tunnel ventilation system is more important than that of other tunnels. So, we conducted that the effects of ventilation systems was simulated depending on the difference of electrical power tunnel length, the number of shaft tunnel, forced ventilation and duct was or not. Test results show that the main conditions in order to enhance the underground cable tunnel are that ventilation systems have to be designed with forced ventilation and with duct.

  • PDF

동력 철도차량 기관실의 효과적인 환기에 관한 실험적 연구 (Experiments on the Effective Engine Room Ventilation in a Power Car)

  • 한석윤;이진호
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.166-176
    • /
    • 1990
  • Experimental study was made to find the effective ways for cooling of engine room in a power car through natural ventilation, forced ventilation and wind tunnel test of 1:10 model. Through the measurements of inner temperature of engine room and pressure distribution of model surface for the various opening combinations and the fan locations, the following results are obtained. For natural ventilation, side and top opening combination is more effective than the side openings only and optimal opening combination is all side openings with top center opening. For forced ventilation with fan on the roof, the combination of all sides and top opening is more effective than the combination of side and top opening, and the optimal location of fan is top center. When the model is located in the air stream, the combination of side and top opening is more effective than the side openings only, and the optimal location of top opening is the front opening. With both air stream and forced ventilation, the optimal location of fan is the side region, and the direction of side grill installation is found to have negligible effect on the room ventilation.

  • PDF