• Title/Summary/Keyword: forced-ventilation

Search Result 142, Processing Time 0.033 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Effect of Physical Training on Pulmonary Function (체력단련(體力鍛鍊)이 폐기능(肺機能)에 미치는 효과(效果))

  • Nam, Pal-Soo;Hwang, Soo-Kwan;Kim, Hyeong-Jin;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.15 no.1
    • /
    • pp.37-43
    • /
    • 1981
  • In the present study, an effort was directed to elucidate the effect of the physical training on the pulmonary function. Twenty-four male athletics major students who have undergone regular physical training for more than five years were randomly chosen as the athletic subjects, and 12 regular male students who have not been engaged in any form of regular physical exercise or training were chosen as the non-athletic subjects, and a comparison was made between the two groups. The following were mainly observed by spirometry for the study; respiratory rate, tidal volume, vital capacity, maximum voluntary ventilation(MVV), forced expiratory volume for 1 second$(FEV_1)$, percent $FEV_1$ to forced vital capacity$(FEV_1%)$, forced expiratory flow for initial 1 liter$(FEF_{0.2-1.2}L)$, and forced mid-expiratory flow$(FEF_{\;25-75}%)$. The results obtained are summarized as follow. 1) The respiratory rate, tidal volume, and vital capacity showed no significant difference between athletes and non-athletes. The MVV in athletes was significantly (p<0.01) increased to $148.1{\pm}3.1\;L/min$ comparing with $118.3{\pm}9.1\;L/min$ in non-athletes. 2) $FEV_1$ was $3.310{\pm}0.070\;L$ in athletes and $2.779{\pm}0.104$ in non-athletes; $FEV_1%\;83.63{\pm}1.29%$ in athletes and $75.33{\pm}1.75%$ in non-athletes, both showing significant(p<0.01) increase in athletes. 3) $FEF_{0.2-1.2}L$ was $297.1{\pm}13.5\;L/min in athletes and $222.7{\pm}15.0\;L/min$ in non-athletes; $FEF_{\;25-75}%$ was $3.543{\pm}0.109\;L/sec$ in non-athletes, both showing significant(p<0.01) increase in athletes. 4) Some discussions were made on these results. The lung volumes showed no significant difference between the two groups. But MVV, $FEV_1$, $FEV_1%$, $FEF_{0.2-1.2}L$ and $FEF_{25-75}%$ in athletes were significantly(p<0.01) higher than in non-athletes. It is therefore concluded that the athletes have more powerful respiratory muscles, or higher compliance of the lung and thorax than the non-athletes.

  • PDF

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

An Overview of Biopulping Research: Discovery and Engineering

  • Scott, Gary M.;Akhtar, Masood;Lentz, Michael J.;Horn, Eric;Swaney, Ross E.;Kirk, T.Kent
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.4
    • /
    • pp.18-27
    • /
    • 1998
  • Biopulping is defined as the treatment of wood chips with lignin-degrading fungi prior to pulping. Fungal pretreatment prior to mechanical pulping reduces electrical energy requirements during refining or increases mill throughput, improves paper strength, reduces the pitch content, and reduces the environmental impact of pulping. Our recent work involved scaling up the biopulping process towards the industrial level, investigating both the engineering and economic feasibility. We envision the process to be done in either a chip-pile or silo-based system for which several factors need to be considered: the degree of decontamination, a hospitable environment for the fungus, and the overall process economics. Currently, treatment of the chips with low-pressure steam is sufficient for decontamination and a simple, forced ventilation system maintains the proper temperature, humidity, and moisture conditions, thus promoting uniform growth of the fungus. The pilot-scale trial resulted in the successful treatment of 4 tons of wood chips (dry weight basis) with results comparable to those on a laboratory. Larger, 40-ton trials were also successful, with energy savings and paper properties comparable with the laboratory scale. The overall economics of the process also look very favorable and can result in significant annual savings to the mill. Although the current research has focused on biopulping for mechanical pulping, it is also beneficial for sulfite chemical pulping and some applications to recycled fiber have been investigated.

  • PDF

Prevention of Barn Rot during Curing of Burley Tobacco. II. Effect of Curing Conditions and Supplemental Heat. (버어리종 잎담배 건조시 부패방지 II. 건조조건과 보조화력의 영향)

  • 배성국;임해건;한철수
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.4
    • /
    • pp.331-334
    • /
    • 1989
  • This studies were carried out to investigate the effects of the management of curing barn and the use of supplemental heat on prevention of barn rot during the rainy season. The managemental methods of curing barn were combined with hanging spaces ranged from 15cm to 30cm and ventilating conditions. The supplemental heat was applied with oil burner and oil fan heater. Barn rot was reduced in the wider hanging spaces, and the effects of hanging spaces was larger with ventilating during curing. Barn rot decreased by ventilating condition than non-ventilation. The use of supplemental heat dropped to lower relative humidity in curing barn. Supplemental heat and forced-air movement greatly reduced barn rot in comparison with tobacco cured under natural conditions.

  • PDF

A Study on Economical Efficiency Evaluation of Semiforcing under Structure Watermelon Cultivators (반촉성 시설수박 재배농가의 경제적 효율성 분석)

  • Kim, Woong;Kim, Jai Hong
    • Korean Journal of Agricultural Science
    • /
    • v.33 no.2
    • /
    • pp.179-193
    • /
    • 2006
  • Technical efficiency of semiforcing watermelon growers is 0.8248 on average, and distributed between 0.6744 and 0.9268. The result showed that semiforcing watermelon growers had by 18% of technical inefficiency and could be assumed that increasing technical efficiency could induce watermelon production more increase. Consequently, if growers' technical efficiency were improved while other environments were constant, watermelon production could be increased. Following the results from the inefficiency effect model, all assumption coefficient such as growers age etc, are significant at 10% level. Estimate of dispersion parameter ${\gamma}$ is 0.89, which confirms those differences between practical output and frontier output were derived from the technical efficiencies among growers. Differences of production system between high and low level growers in production efficiency were showed at side altitude, ventilation and heat-retaining in section of facilities and automation, soil test and calcium application in section of environment management, transplant preparation and duration of pollination in section of crop management and shipment place, sorting degree and management record analysis in section of business management respectively. As a result of analyzing consulting data by using standard diagnosis table of watermelon cultivation under structure which cultivated on semi-forced watermelon growers, gap between high and low level growers was 7.0 points in facility automation section, 7.1 points in environment section, 8.8 points in crop management section and 13.6 points in business management section, respectively, which were the biggest one among them. In case of excluding information-related items from the evaluation index of business management section, changes of business achievement are to occur. Therefore, it is recommended for us to review the standard diagnostic table of watermelon cultivation under structure by dividing evaluation index of management section into management and information.

  • PDF

Is There Any Immediate Difference between Pulmonary Function and Respiratory Muscle, with or without Vibration Stimulation in Respiratory Resistance Training? (진동 자극 유무에 따른 호흡 저항 훈련 시 폐 기능과 호흡근의 즉각적인 차이가 있을까?)

  • Park, Jin-Young;Kim, Ye-Seul;Park, Hyun-Ju;Lee, Myung-Mo
    • Journal of Korean Physical Therapy Science
    • /
    • v.25 no.3
    • /
    • pp.17-24
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effect of whole body vibration combined breathing resistance on lung capacity and respiratory muscle and to suggest a mediation method for improvement of respiratory function and lung function in the future. Methods: This study was a preliminary study design of two groups of 54 healthy young adults who were randomly assigned to an experimental group (n=27) with core exercise combined with respiratory resistance and whole body vibration and a control group with respiratory resistance and core exercise (n=27). All interventions consisted of 6 core exercises every 40 seconds and rest for 20 seconds. To compare the effects of intervention, we measured spirometry and respiratory muscle strength. Results: Both the experimental group and the control group showed a significant increase in Forced vital capacity (FVC) and Maximum voluntary ventilation (MVV) (p<.05). However, FEV1 and FEV1% were significantly increase only in the experimental group (p<.05). FVC, FEV1%, Maximum Inspiratory Pressure (MIP), Maximum Expiratory Pressure (MEP) showed more significant increase in the experimental group than the control group. Conclusion: These findings indicate that whole-body vibration combined breathing resistance is an effective intervention for people, with FVC, FEV1%, MIP, MEP increase.

Development of high-efficiency heating system using humidifying particles (가습 입자를 활용한 고효율 난방 시스템 개발)

  • Lee, Jeong-Won;Hong, Kyung-Bo
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.17-24
    • /
    • 2020
  • Products for heating indoors in low temperature and dry winter are largely divided into products using fossil fuels and products using electricity. The fossil fuels can warm the entire space by convection, but there is a high risk of fire and the frequent ventilation due to the increase in carbon monoxide and carbon dioxide. Heaters using electricity are mainly used because they are convenient to use and are cheap. However, these products can not efficiently warm the air because they use radiation energy. In other words, only the front part exposed to the heater is warm, and the rear part has no heating effect at all. Also, because it emits a large amount of light, fatigue of the eyes is very high. Another problem is that when using electric heaters, the room tends to be dry by high heat. Indoor humidity maintenance is a very important factor in the prevention and treatment of respiratory diseases. Especially, it is essential for health care for infants, bronchial organs and people with weak respiratory because humidity is low in winter. In this study, we conducted a study to develop a product that can improve heating efficiency while maintaining proper indoor humidity by combining heat energy and moisture particles. The concept of humidification and heating at the same time, moisture particles generated in the humidifier pass through the heater, include thermal energy, and the moisture particles with thermal energy are diffused into the space by forced convection, thereby warming the entire space. In addition, the heating time is shortened as the feeling temperature is increased with the high relative humidity, and this has the effect that the heating cost in winter is reduced.

Effects of Farinelli Breating Exercise on Respiratory Function and Symptoms in Patients with Chronic Obstructive Pulmonary Disease

  • Ittinirundorn, Supawit;Wongsaita, Naiyana;Somboonviboon, Dujrath;Tongtako, Wannaporn
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.2
    • /
    • pp.137-146
    • /
    • 2022
  • Background: Farinelli breathing (FB) exercise is a typical breathing exercise used by singers. This study aimed to compare effects of FB exercise and diaphragmatic breathing (DB) exercise on respiratory function and symptoms in patients with chronic obstructive pulmonary disease (COPD). Methods: Sixteen patients aged 51-80 years with mild or moderate COPD were recruited for this study. They were divided into two groups: DB group (n=8) and FB group (n=8). Both groups received complete breathing exercise training five times per week for 8 weeks. Their respiratory functions, COPD symptoms, cytokine levels, and oxidative stress variables were analyzed during pre- and post-tests. Dependent variables were compared between pre- and post-tests using paired t-tests. An independent t-test was used to compare variables between the groups. Differences were considered significant at p<0.05. Results: The maximal expiratory pressure (MEP), maximum oxygen consumption (VO2max), and COPD Assessment Test (CAT) scores changed significantly in the DB group after the 8-week intervention compared to those at pre-test, whereas force vital capacity, forced expiratory volume in the first second, maximum voluntary ventilation, maximal inspiratory pressure (MIP), MEP, VO2max, CAT score, tumor necrosis factor-α, and malondialdehyde level changed significantly in the FB group at post-test compared to those at pre-test. Moreover, both MIP and MEP in the FB group were significantly higher than those in the DB group. Conclusion: FB exercise improved respiratory functions and COPD symptoms of patients with COPD. It might be an alternative breathing exercise in pulmonary rehabilitation programs for patients with COPD.

Effects of grain-based pecking blocks on productivity and welfare indicators in commercial broiler chickens

  • Byung-Yeon Kwon;Hyun-Gwan Lee;Yong-Sung Jeon;Ju-Yong Song;Jina Park;Sang-Ho Kim;Dong-Wook Kim;Kyung-Woo Lee
    • Animal Bioscience
    • /
    • v.37 no.3
    • /
    • pp.536-546
    • /
    • 2024
  • Objective: This experiment was conducted to investigate the effect of grain-based pecking blocks on productivity and welfare status at two commercial broiler welfare-certified farms. Methods: Production and welfare indicators were assessed at two farms (designated Farm A and B). Both farms had two windowless houses with forced tunnel-type ventilation and housed broilers at stocking densities of approximately 16.7 birds/m2 (Farm A) and 16.8 birds/m2 (Farm B). Each house was divided into two or three equal sections and was provided with or without pecking blocks. Grain-based pecking blocks, measuring 25 × 25 × 25 cm, were given to broilers in both farms at 1 block per 1,000 birds. Various parameters including productivity (body weight and flock uniformity), corticosterone levels (in fecal droppings and feathers), footpad dermatitis, hock burn, feather dirtiness, gait score, litter quality, body surface temperature, and volatile fatty acids in fecal samples were assessed at 26 days of age, whereas litter quality was analyzed at 13 and 26 days of age. Results: There were no significant effects of providing pecking blocks on productivity (body weight and uniformity), fecal and feather corticosterone, welfare indicators (i.e., footpad dermatitis, hock burn, feather cleanliness, and gait score), and litter quality (i.e., moisture, nitrogen, and pH). No differences in body surface temperature between the control and enrichment treatments were noted in Farm B, but body surface temperatures of the head (p = 0.029) and legs (p = 0.011) in the enrichment vs. control group were elevated in Farm A. Butyrate concentration in the enrichment vs control group was higher in Farm B (p = 0.023), but this effect was not detected in Farm A. Conclusion: It is concluded that grain-based pecking blocks did not affect performance and welfare indicators. Further studies are warranted to elucidate the potential impact of grain-based pecking blocks on gut health indicators.