• 제목/요약/키워드: force-carrying capacity

검색결과 96건 처리시간 0.018초

Introducing a new all steel accordion force limiting device for space structures

  • Poursharifi, Maryam;Abedi, Karim;Chenaghlou, Mohammadreza;Fleischman, Robert B.
    • Structural Engineering and Mechanics
    • /
    • 제74권1호
    • /
    • pp.69-82
    • /
    • 2020
  • A significant defect of space structures is the progressive collapse issue which may restrict their applicability. Force limiting devices (FLDs) have been designed to overcome this deficiency, though they don't operate efficiently in controlling the force displacement characteristics. To overcome this flaw, a new type of FLD is introduced in the present study. The "all steel accordion force limiting device" (AFLD) which consists of three main parts including cylindrical accordion solid core, tubular encasing and joint system is constructed and its behavior has been studied experimentally. To improve AFLD's behavior, Finite element analysis has been carried out by developing models in ABAQUS software. A comprehensive parametric study is done by considering the effective design parameters such as core material, accordion wave length and accordion inner diameter. From the results, it is found that AFLD can obtain a perfect control on the force-displacement characteristics as well as attaining the elastic-perfect plastic behavior. Obtaining higher levels of ultimate load carrying capacity, dissipated energy and ductility ratio can be encountered as the main privileges of this device. Ease of construction and erection are found to be further advantages of AFLD. Based on the obtained results, a procedure for predicting AFLD's behavior is offered.

직선배치된 외부 긴장재로 보강된 2경간 강합성교의 증가 프리스트레스력을 고려한 내하율 산정식을 이용한 보강설계 (Strengthening Design Using Rating Factor Considering Increment of Tendon Force for Two-Span Steel-concrete Composite Bridges Strengthened by Straight External Tendons)

  • 최동호;유훈;김용식;김성원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권2호통권54호
    • /
    • pp.153-164
    • /
    • 2009
  • 본 논문에서는 2경간 강합성교량의 내하력을 향상시키기 위해, 외부 긴장재로 보강하는 방법을 제시하였다. 긴장재를 직선 배치하였을 경우, 외부하중으로 인한 증가 프리스트레스력을 가상일의 원리로 구하였고, 증가 프리스트레스를 고려한 내하율 산정식을 제시하였다. 제안된 내하율 산정식으로부터, 긴장재 개수와 초기 긴장력의 계산방법을 제시하였다. 본 방법을 2경간 강합성교량에 적용하여, 산정식의 타당성과 합리성을 검증하였다.

내하율을 이용한 강합성보의 외부 프리텐션과 포스트텐션 보강 설계 (Strengthening Design by External Pre-tensioning and Post-tensioning Methods for Steel-concrete Composite Girders using Rating Factor)

  • 최동호;유동민;정구상;박경부
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권5호
    • /
    • pp.123-134
    • /
    • 2007
  • 본 논문은 기존 강합성 교량의 내하력 향상을 목적으로 외부 긴장재의 초기 긴장력 결정 방법을 제시하였다, 외부 긴장력은 콘크리트 슬래브 재시공 전과 후에 각각 적용하였다. 활하중에 의하여 발생하는 증가 프리스트레스력을 고려한 내하율식을 제안하여 긴장재 개수와 초기 긴장력의 결정 과정을 제시하였다. 기존 강합성 교량의 내하율 향상에 적용하여 그 타당성을 입증하였다.

철도노반 침하저감을 위한 토목섬유 감쌈 쇄석말뚝 설계방안 고찰 (A Study on Design Method of Geogrid Encased Stone Colum for Settlement Reduction in Railroad)

  • 이대영
    • 한국지반신소재학회논문집
    • /
    • 제13권3호
    • /
    • pp.31-38
    • /
    • 2014
  • 지오그리드 감쌈 쇄석말뚝 공법은 지오그리드의 인장구속효과로 인해 연약지반에 시공된 쇄석말뚝의 지지력을 증가시켜주는 공법이다. 본 연구에서는 토목섬유 감쌈 쇄석말뚝(GESC)공법의 설계에 적용할 수 있는 토목섬유 인장저항력과 극한지지력을 산정할 수 있는 합리적인 설계법을 제안하였다. 제안된 설계방법의 적적성을 평가하기 위해 부산 경전선 연약지반 시험시공 결과로부터 산출된 GESC의 극한지지력과 설계법에의해 산정된 극한지지력을 비교 검증하였다. 연구결과 GESC 설계법에 의해 산정된 지지력이 현장시험의 지지력 보다 크게 나타나는 것으로 검토되었다.

사다리꼴 유공웨브 형강보의 안전내력에 관한 연구 (Resistant Capacity of Longitudinally Traperzoidal Web Section with Opening)

  • 손기상
    • 한국안전학회지
    • /
    • 제7권4호
    • /
    • pp.63-71
    • /
    • 1992
  • Generally, Web & Flange of I shape beam are composed of plane for optimization of measurement in investigating the behavior resistant to horizontal force and bending moment on large section Therefore, longitudinally traperzoidal web section beam has an important function as a body for carrying more load and ensuring more support area. There is only a limited usefulness for analyzing the behavior of web section with opening. It is experimentally verified that this traperzoidal web section has a good resistant caopacity. conclustions on the above research results are as follows : 1) resistant capacity on the above can be more 15% increased than normal case 2) stiffener welding work and complexity of shopdrawing can be excluded in advance 3) traperzoidal section can be applied in structural practice.

  • PDF

Evaluation of seismic performance of mid-rise reinforced concrete frames subjected to far-field and near-field ground motions

  • Ansari, Mokhtar;Ansari, Masoud;Safiey, Amir
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.453-462
    • /
    • 2018
  • Damages to buildings affected by a near-fault strong ground motion are largely attributed to the vertical component of the earthquake resulting in column failures, which could lead to disproportionate building catastrophic collapse in a progressive fashion. Recently, considerable interests are awakening to study effects of earthquake vertical components on structural responses. In this study, detailed modeling and time-history analyses of a 12-story code-conforming reinforced concrete moment frame building carrying the gravity loads, and exposed to once only the horizontal component of, and second time simultaneously the horizontal and vertical components of an ensemble of far-field and near-field earthquakes are conducted. Structural responses inclusive of tension, compression and its fluctuations in columns, the ratio of shear demand to capacity in columns and peak mid-span moment demand in beams are compared with and without the presence of the vertical component of earthquake records. The influences of the existence of earthquake vertical component in both exterior and interior spans are separately studied. Thereafter, the correlation between the increase of demands induced by the vertical component of the earthquake and the ratio of a set of earthquake record characteristic parameters is investigated. It is shown that uplift initiation and the magnitude of tensile forces developed in corner columns are relatively more critical. Presence of vertical component of earthquake leads to a drop in minimum compressive force and initiation of tension in columns. The magnitude of this reduction in the most critical case is recorded on average 84% under near-fault ground motions. Besides, the presence of earthquake vertical components increases the shear capacity required in columns, which is at most 31%. In the best case, a direct correlation of 95% between the increase of the maximum compressive force and the ratio of vertical to horizontal 'effective peak acceleration (EPA)' is observed.

콘크리트 충전강관 기둥과 PC 철근 콘크리트 보 접합부의 개발에 관한 연구( I ) -단면형상 및 축력비를 변수로 한 접합부 모델의 적합성 검토- (A Study on Development for Joint of Concrete Filled Steel Tube Column and P.C Reinforced Concrete Beam ( I ) The Investigation of Propriety for Model of Beam-to-Column Joint with Key Parameters, such as Section Type and Axial Force Ratio)

  • 박정민;김화중;문태섭;김규석
    • 한국강구조학회 논문집
    • /
    • 제8권4호통권29호
    • /
    • pp.85-94
    • /
    • 1996
  • This paper investigated structural behaviors of joint of concrete filled steel tube column and P.C reinforced concrete beam through a series of hysteretic behavior experiment. The results are summarised as follows: (1) The joint stiffness of concrete filled square steel tube column and P.C reinforecd beam was higher than that of concrete filled circular steel tube column and P.C reinforecd beam, and it was decreased as the increase of the number of hysteretic cycle. (2) The aspects of the hysteretic behavior in the joint was stable as the increase of the number of hysteretic cycle, and rotation resisting capacity of joint of concrete filled square steel tube column and P.C reinforced concrete beam was higher than those of the concrete filled circular steel tube column and P.C reinforced concrete beam. (3) Some restriction must be put upon the ratio of axial force in this joint model because the load carrying capacity was decreased by flexural and flexural-torsional buckling in case of the ratio of axial force 0.6. (4) The emprical formula to predict the ultimate capacity of joint model to superimpose shearing strength of steel web(H section) and bending strength of reinforced concrete beam was expected.

  • PDF

합성보 전단연결부의 구조거동에 대한 비교 분석 (Analysis of a Load Carrying Behavior of Shear Connection at the Interface of the Steel-Concrete Composite Beam)

  • 신현섭
    • 한국강구조학회 논문집
    • /
    • 제17권6호통권79호
    • /
    • pp.737-747
    • /
    • 2005
  • 강재 보와 콘크리트 슬래브로 구성되어 지는 합성보에서 두 부재는 일반적으로 전단연결재에 의해 서로 합성되어져 일체적인 구조거동을 하게 된다. 현재까지 전단연결재로서는 스터드(stud)가 널리 사용되어지고 있다. 합성보의 구조적 거동은 사용된 부재의 재료적 특성 외에도 스터드에 의한 전단합성작용에 의해 많은 영향을 받게 된다. 합성보 전단연결부에서의 전단합성거동은 합성보에서가 아닌 단순화된 Push-Out 시험체(Push-Out Test Specimen)에 의해 실험적으로 결정되고 있다. 최근의 연구결과에 따르면, Push-Out 실험에서 얻은 전단 스터드의 합성거동과 실제 합성보에서의 전단합성거동에는 분명한 차이점이 존재하며, 특히 부분합성된 합성보에서는 그 차이가 매우 크다는 것이 밝혀지고 있다. 본 연구에서는 표준 Push-Out 시험체 및 합성보의 구조거동 해석을 위해, Push-Out 실험으로부터 결정되는 스터드에 대한 하중-상대변위 곡선의 도입이 필요 없는 3차원 유한요소모델을 개발하였다. 해석결과의 비교 분석으로부터 합성보 전단연결부에서의 합성거동을 평가할 수 있었고, 이를 Push-Out 실험결과와 비교하여 보았으며 전단합성거동의 차이점에 대한 구체적 원인을 찾을 수 있었다.

Smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendon-anchorage connection

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제9권6호
    • /
    • pp.489-504
    • /
    • 2012
  • For the safety of prestressed structures such as cable-stayed bridges and prestressed concrete bridges, it is very important to ensure the prestress force of cable or tendon. The loss of prestress force could significantly reduce load carrying capacity of the structure and even result in structural collapse. The objective of this study is to present a smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendon-anchorage connection. Firstly, a smart PZT-interface is newly designed for sensitively monitoring of electro-mechanical impedance changes in tendon-anchorage subsystem. To analyze the effect of prestress force, an analytical model of tendon-anchorage is described regarding to the relationship between prestress force and structural parameters of the anchorage contact region. Based on the analytical model, an impedance-based method for monitoring of prestress-loss is conducted using the impedance-sensitive PZT-interface. Secondly, wireless impedance sensor node working on Imote2 platforms, which is interacted with the smart PZT-interface, is outlined. Finally, experiment on a lab-scale tendon-anchorage of a prestressed concrete girder is conducted to evaluate the performance of the smart PZT-interface along with the wireless impedance sensor node on prestress-loss detection. Frequency shift and cross correlation deviation of impedance signature are utilized to estimate impedance variation due to prestress-loss.

외부 긴장재로 보강된 2경간 연속 강합성보의 초기 긴장력 결정 (Determination of the Initial Tendon Force in Two-span Continuous Steel-Concrete Composite Beam Strengthened with External Tendons)

  • 최동호;유동민;정재동;김은지
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.145-154
    • /
    • 2006
  • 본 논문은 외부 긴장재로 보강된 2경간 연속 강합성보의 내하력을 향상시키기 위한 방법을 제시하였다. 긴장재를 정모멘트 구간의 강주형 하부에 설치하였다. 이 방법은 정모멘트 뿐만 아니라 부모멘트도 감소시킬 수 있다. 강합성보를 긴장재로 보강함으로써 내하율 식에서 목표 내하율을 만족시키기 위한 긴장재 개수와 초기 긴장력의 결정방법을 기술하였다. 본 방법을 실교량의 강합성보에 적용하여 타당성을 입증하였다.