• 제목/요약/키워드: force sensing

검색결과 347건 처리시간 0.028초

헬스케어용 실내 자전거 운동에 의한 호흡가스 분석 (Analysis of Respiratory Gas by Training on Healthcare Indoor Bicycle)

  • 홍철운;강형섭;김기범
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권2호
    • /
    • pp.147-152
    • /
    • 2009
  • This study was conducted to observe the change of limbs stroke and respiration gas parameters in our new bicycle fitness system. We hypothesized that the variable force of left and right limbs might be effective for sensing stimulation in modified new unequal pedal bicycle system. It has been developed, which can provide visual information and different length of pedal with left and right limbs. Experimental results showed different activities between the left and right limbs where the activity of the left limb increased than that of right limb. Especially, the soleous muscle activity increased both in control and experimental groups by this training method. But oxygen and carbon dioxide partial pressures in respiratory gas increased during training method. These results suggest that acidosis of blood was led by this process. Consequently, this bicycle training is concluded that aerobic training could affect different limb activities. Finally, we expect that our new bicycle system will be effective for healthcare with proper balance between the left and right limbs.

착용형 전동 목발 제어시스템 (Wearable and Motorized Crutch Control System)

  • 윤덕찬;장기호;최영진
    • 로봇학회논문지
    • /
    • 제9권3호
    • /
    • pp.133-139
    • /
    • 2014
  • This paper proposes a wearable and motorized crutch control system for the patients using the conventional crutches. The conventional crutches have a few disadvantages such as the inconvenience caused by the direct contact between the ground and the armpit of the patients, and unstable gait patterns. In order to resolve these problems, the motorized crutch is designed as a wearable type on an injured lower limb. In other words, the crutch makes the lower limb to be moved forward while supporting the body weight, protecting the lower limb with frames, and rotating a roller equipped on the bottom of the frames. Also the crutch is controlled using the electromyography and two force sensing resistor (FSR) sensors. The electromyography is used to extract the walking intention from the patient and the FSR sensors to classify the stance and swing phases while walking. As a result, the developed crutch makes the patients walk enabling both hands to be free, as if normal people do.

다이아몬드 터닝 머시인의 극초정밀 절삭공정에서의 시스템 규명 및 제어 (System identification and admittance model-based nanodynamic control of ultra-precision cutting process)

  • 정상화;김상석;오용훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1352-1355
    • /
    • 1996
  • The control of diamond turning is usually achieved through a laser-interferometer feedback of slide position. If the tool post is rigid and the material removal process is relatively static, then such a non-collocated position feedback control scheme may surface. However, as the accuracy requirement gets tighter and desired surface contours become more complex, the need for a direct tool-tip sensing becomes inevitable. The physical constraints of the machining process prohibit any reasonable implementation of a tool-tip motion measurement. It is proposed that the measured force normal to the face of the workpiece can be filtered through an appropriate admittance transfer function to result in the estimated depth of cut. This can be compared to the desired depth of cut to generate the adjustment control action in addition to position feedback control. In this work, the design methodology on the admittance model-based control with a conventional controller is presented. The recursive least-squares algorithm with forgetting factor is proposed to identify the parameters and update the cutting process in real time. The normal cutting forces are measured to identify the cutting dynamics in the real diamond turning process using the precision dynamometer. Based on the parameter estimation of cutting dynamics and the admittance model-based nanodynamic control scheme, simulation results are shown.

  • PDF

LTCC 기판을 이용한 PZT 압력 센서의 제작 및 특성 연구

  • 허원영;황현석;이태용;이경천;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.13-13
    • /
    • 2010
  • Piezoelectric sensors are extensively used to measure force because of their high sensitivity and low cost. however, the development of device with reduced size but with improved sensitivity is highly important. Low-temperature co-fired ceramic (LTCC) is one of promising materials for this application than a silicon substrate because it has very good electrical and mechanical properties as well as possibility of making various three dimensional (3D) structures. In this work, piezoelectric pressure sensors based on hybrid LTCC technology were presented. The LTCC diaphragms with thickness of $400\;{\mu}m$ were fabricated by laminating 12 green tapes which consist of alumina and glass particle in an organic binder. The piezoelectric sensing layer consists of PZT thin film deposited by RF magnetron sputtering method on between top and bottom Au electrodes. The PZT films deposited on LTCC diaphragms were successfully grown and were analyzed by using X-ray diffraction method (XRD) and field emission scanning electron microscope (FESEM).

  • PDF

저항센서와자이로센서를이용한새로운보행주기검출시스템의개발및평가 (Development and Evaluation of a New Gait Phase Detection System using FSR Sensors and a Gyrosensor)

  • 안승찬;황성재;강성재;김영호
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.196-203
    • /
    • 2004
  • In this study, a new gait phase detection system using both FSR(Force Sensing Resister) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the posterior aspect of a shoe. An algorithm was also developed to determine eight different gait transitions among four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was compared with the conventional gait phase detection system using only FSR sensors in various gait experiments such as level walking, fore-foot walking and stair walking. In fore-foot walking and stair walking, the developed system showed much better accuracy and reliability to detect gait phases. The developed gait phase detection system using both FSR sensors and a gyrosensor will be helpful not only to determine pathological gait phases but to apply prosthetics, orthotics and functional electrical stimulation to patients with gait disorders.

어드미턴스 모델을 이용한 다이아몬드 터닝머시인의 극초정밀 제어 (Admittance Model-Based Nanodynamic Control of Diamond Turnning Machine)

  • 정상화;김상석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 1996
  • The control of diamond turning is usually achieved through a laser-interferometer feedback of slide position. The limitation of this control scheme is that the feedback signal does not account for additional dynamics of the tool post and the material removal process. If the tool post is rigid and the material removal process is relatively static, then such a non-collocated position feedback control scheme may surfice. However, as the accuracy requirement gets tighter and desired surface contours become more complex, the need for a direct tool-tip sensing becomes inevitable. The physical constraints of the machining processprohibit any reasonable implementation of a tool-tip motion measurement. It is proposed that the measured force normalto the face of the workpice can be filterd through an appropriate admittance transfer function to result in the estimated depth of cut. This can be compared to the desired depth of cut to generate the adjustment cotnrol action in addition to position feedback control. In this work, the design methodology on the admittance model-based control with a conventional controller is presented. Based on the empirical data of the cutting dynamics, simulation results are shown.

  • PDF

보행로봇의 신경망 이론을 이용한 가상센서 검증 (Virtual Sensor Verification Using Neural Network Theory of the Quadruped Robot)

  • 고광진;김완수;유승남;한창수
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1326-1331
    • /
    • 2009
  • The sensor data measured by the legged robot are used to recognize the physical environment or information that controls the robot's posture. Therefore, a robot's ambulation can be advanced with the use of such sensing information. For the precise control of a robot, highly accurate sensor data are required, but most sensors are expensive and are exposed to excessive load operation in the field. The seriousness of these problems will be seen if the prototype's practicality and mass productivity, which are closely related to the unit cost of production and maintenance, will be considered. In this paper, the use of a virtual sensor technology was suggested to address the aforementioned problems, and various ways of applying the theory to a walking robot obtained through training with an actual sensor, and of various hardware information, were presented. Finally, the possibility of the replacement of the ground reaction force sensor of legged robot was verified.

MOTION OF GLACIERS, SEA ICE, AND ICE SHELVES IN CANISTEO PENINSULA, WEST ANTARCTICA OBSERVED BY 4-PASS DIFFERENTIAL INTERFEROMETRIC SAR TECHNIQUE

  • Han, Hyang-Sun;Lee, Hoon-Yol
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.414-417
    • /
    • 2008
  • We have extracted a surface deformation map of a part of Canisteo Peninsula on Amundsen Sea in West Antarctica by applying 4-pass DInSAR technique to two ERS-1/2 tandem pairs obtained on October 21-22, 1995 (diff-pair) and March 9-10, 1996 (topo-pair), and analyzed changes of glaciers, sea ice, ice shelves, and their kinematic interactions. We observed fast motion of glaciers pushing the adjoining sea ice. Some interferometric phases indicate the up-rise of sea ice of which type is thought to be land-fast ice to exert repulsive force against the pushing glacier. There were other glaciers and sea ice that moved to the same direction, suggesting that the sea ice in these regions was land-fast ice weakly harnessed to sea bottom or pack ice not harnessed at all. Several small circular fringes in ice shelves suggested that islands or seamounts on the bottom of ice shelves deterred the movement of ice shelves, resulting in the rise of ice surface.

  • PDF

로봇형 차량의 자율주행을 위한 센서 기반 운동 계획법 개발 (Development of Sensor-based Motion Planning Method for an Autonomous Navigation of Robotic Vehicles)

  • 김동형;김창준;이지영;한창수
    • 제어로봇시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.513-520
    • /
    • 2011
  • This paper presents the motion planning of robotic vehicles for the path tracking and the obstacle avoidance. To follow the given path, the vehicle moves through the turning radius obtained through the pure pursuit method, which is a geometric path tracking method. In this paper, we assume that the vehicle is equipped with a 2D laser scanner, allowing it to avoid obstacles within its sensing range. The turning radius for avoiding the obstacle, which is inversely proportional to the virtual force, is then calculated. Therefore, these two kinds of the turning radius are used to generate the steering angle for the front wheel of the vehicle. And the vehicle reduces the velocity when it meets the obstacle or the large steering angle using the potentials of obstacle points and the steering angle. Thus the motion planning of the vehicle is done by planning the steering angle for the front wheels and the velocity. Finally, the performance of the proposed method is tested through simulation.

비연성 수직형 마이크로 자이로스코프의 구조해석 및 최적설계 (Structural Analysis and Optimum Design of a De-coupled Vertical Micro-Gyroscope)

  • 박성균;정희문;김명훈;김형태;하성규
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1840-1848
    • /
    • 2003
  • This paper presents the structural analysis and optimum design of a vertical micro-gyroscope with decoupled 2 degrees of freedom (DOF), driven by electrostatic force. Simplified beam models were presented to derive the structural stiffness of the driving spring of the U shape and the sensing spring of I shape. A finite element analysis (FEA) was performed to validate each derivation. A total mass and a polar mass moment of inertia were also obtained and used in calculating the resonance frequency at each mode of the 2 DOF. The resonance frequencies of the total system were calculated using the proposed models and it has been found that they were in excellent agreement with those of the FEA. Finally, the developed analysis program was then linked to an optimum design module, and an optimum design of the micro-gyroscope was successfully performed.