• 제목/요약/키워드: focusing

검색결과 18,655건 처리시간 0.053초

GB-SAR 시스템의 영상화 및 간섭기법 (Focusing and Interferometry of a GB-SAR System)

  • 이훈열;조성준;성낙훈;김정호
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.145-150
    • /
    • 2007
  • We briefly introduce the theory of GB-SAR focusing and interferometry. Deramp-FFT algorithm is evaluated as a far-range, partial focusing method along with its limitations in the near-range application. Various interferometric configurations with temporal, spatial, and/or frequency baselines are also discussed.

  • PDF

The DOA Estimation of Wide Band Moving Sources

  • Cho, Mun-Hyeong
    • Journal of information and communication convergence engineering
    • /
    • 제5권1호
    • /
    • pp.12-16
    • /
    • 2007
  • In this paper, a new method is proposed for tracking the direction-of-arrival (DOA) of the wideband moving source incident on uniform linear array sensors. DOA is estimated by focusing transformation matrices. To update focusing matrices along with new data snap shots, we use the FAST (Fast Approximate Subspace Tracking) method. Present focusing matrices are constructed by previous signal and its orthogonal basis vectors as well as present signal and its orthogonal basis vectors, which are the left and right singular vectors of the inner product of two approximated matrices. Simulation results are shown to illustrate the performance of the proposed method.

Image J 프로그램을 이용한 격자집속거리와 격자비에 따른 영상비교평가 (Using Image J program, compared of focusing distance and grid rate)

  • 서원주;서정범;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.37-42
    • /
    • 2012
  • Pediatric head and neck phantom, using the rate by focusing distance and grid images, Image J using the Quality Assessment and Dose Area Product compared. X-ray laboratory equipment due to the Philips Digital DIAGNOST a 110 cm FFD set and using ACE Non-grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Focused grid, Acryl Phantom (Fluke Model 76-2 Series Phantom) 15.24 cm, by resolution chart image acquisition, image evaluation program (Image J Ver. 1.4.3.67, USA) imaging experiments were analyzed using. Dose Area Product in the Non Grid 0.028 $mGy{\cdot}cm^2$, focusing distance 110 cm (12 : 1), the 0.129 $mGy{\cdot}cm^2$, 140 cm (12 : 1), the 0.135 $mGy{\cdot}cm^2$, 180 cm (8 : 1) was measured with a 0.110 $mGy{\cdot}cm^2$ Non Grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Image obtained when grid using the image J program focusing distance 110 cm with grid based on the measured SNR and PSNR Non Grid if the SNR the 17.307 dB, PSNR of the 20.002 dB, if the SNR 28.755 dB, PSNR was measured by the 31.451 dB. Image J image analysis through the streets, rather than focusing on grid by the rate that could see an increase in dose. Select the grid by a small dose rate reduction is possible.

  • PDF

REFOCUSING FOR ON-ORBIT MTF COMPENSATION OF REMOTE SENSING CAMERA

  • Jang Hong-Sul;Jeong Dae-Jun;Lee Seunghoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.601-603
    • /
    • 2005
  • Refocusing methods are used to compensate optical performance degradation of high resolution satellite camera during on-orbit operation. Due to mechanical vibration during launch and thermal vacuum environment of space where camera is exposed, the alignment of optical system may have error. The focusing error is dominant of misalignment and caused by the de-space error of secondary mirror of catoptric camera, which is most sensitive to vibration and space environment. The high resolution camera of SPOT, Pleiades and KOMPSAT2 have refocusing device to adjust focusing during orbital operation while QuickBird of US does not use on orbit refocusing method. For the Korsch type optical configuration which is preferred for large aperture space remote sensing camera, secondary mirror and folding mirror are available as refocusing element.

  • PDF

입력소스의 위치와 센서개수에 따른 평판에서의 시간반전램파의 공간집속성능 규명 (Investigating the spatial focusing performance of time reversal Lamb waves on a plate with respect to input source location and the number of sensors)

  • 서대재;박현우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.722-725
    • /
    • 2014
  • The spatial focusing of time reversal Lamb waves on a plate has attracted considerable attention for identifying the location of an input source. This study investigates the spatial focusing performance on a plate with respect to the number of piezoelectric (PZT) sensors for varying locations of input sources. In particular, a small number of PZT sensors produce spatial focusing through the virtual sensor effect due to reflection of Lamb waves at plate edges. The spatial focusing performance with respect to the number of PZT sensors is quantified in terms of signal to noise ratio through numerical simulation and its implication is discussed.

  • PDF

Use of Time Reversal Techniques for Focusing of Ultrasonic Array Transducer Beams

  • Kim, Hak-Joon;Song, Sung-Jin;Thompson R. Bruce;Kim, Jae-Hee;Eom, Heung-Sup
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.190-197
    • /
    • 2006
  • For enhancement of flaw detactability using array transducers, focusing of ultrasonic waves on a target in an inhomogeneous medium or through a complex geometry is important. But focusing can be strongly degraded by geometrical distortion of field radiated by the array transducers or by sound speed fluctuations in the propagating medium. In recent years, the time reversal technique has been proposed. Thus, in this paper, we describe the basic principal of the time reversal technique for focusing. Then, the implementation results of the time reversal technique for ultrasonic inspections using bulk waves and guided waves generated by array transducers are presented.

나노입자 집속 마스크를 이용한 나노입자 패턴 형성 (Nanoparticle patterning using nanoparticle focusing mask)

  • 유석범;이희철;김형철;최만수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1713-1717
    • /
    • 2008
  • We have developed a nanoparticle focusing mask which can generate particle arrays directly on the large area with high resolution. Using this mask, nanomaterials are precisely deposited onto desired positions on a substrate surface. We obtained various sizes of arrays ranging from 80 nm to 6 ${\mu}m$ with silver and copper nanoparticles that are generated by a spark discharge and an evaporation-condensation method. The feather size is much smaller than that of mask openings due to the focusing effects, like electrostatic lens, caused by charge or electric potential on insulator mask surface, which also prevent a mask clogging. The particle array size depends on the size of mask open patterns and focusing effects near the mask relate to ion flow rate and electric potential. We have demonstrated that diverse size of arrays with high resolution could be obtained repeatedly using the same sized mask in atmosphere.

  • PDF

줄 발열에 의한 온도기울기 농축을 위한 미세채널 형상 최적화 (A Geometric Optimization of a Microchannel for Temperature Gradient Focusing via Joule Heating)

  • 한태헌;김선민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1623-1628
    • /
    • 2008
  • A temperature gradient focusing (TGF) via Joule heating phenomenon was numerically studied. The governing transport equations are implemented into a quasi-1D numerical model to predict the resulting temperature, velocity, and concentration profiles along a microchannel of varying width under an applied electric field. The model is used to analyze the effects of varying certain geometrical parameters of a microchannel on the focusing performance of the device. We show the effects of varying width of the microchannel having a fixed length, and propose the optimal geometry of the device. This method can be easily implemented into lab-on-a-chip (LOC) applications where focusing is required based on its simple design.

  • PDF

초음파 영상에서 Multi-element Receive Synthetic Focusing을 이용한 그레이팅 로브 감축 (A Reduction of Grating Lobe By Using the Multi-element Receive Synthetic Focusing In Ultrasonic Image)

  • 이종석;안영복
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.559-562
    • /
    • 1997
  • In this paper, we propose the method that reduce the grating lobe in the ultrasound synthetic focusing images. synthetic focusing images have more larger and closer grating lobe than conventional phased array images and more lower signal to noise ratio. so, we represent the method that reduce the grating lobe by using multi element receive focusing. experimental results are showed that the proposed multi element receiving method reduce the grating lobe and increase the signal to noise ratio.

  • PDF