• Title/Summary/Keyword: focal region

Search Result 149, Processing Time 0.028 seconds

Study on the Effective Focal Volume Change due to Light Intensity Using Fluorescence Correlation Spectroscopy (형광상관분광법을 이용한 광세기에 따른 유효 초점 부피 변화에 대한 연구)

  • Jeong, Chanbae;Lee, Jaeran;Kim, Sok Won
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.71-76
    • /
    • 2013
  • Using fluorescence correlation spectroscopy, we analyzed the change of effective focal volume of a confocal system with light intensity. The fluorescence correlation spectroscopy system was home-built in accordance with the He-Ne laser with a wavelength of 632.8 nm, and two kinds of samples (AlexaFluor657 and Quantum dot655) suitable for the wavelength of the laser beam were used. For each sample, we analyzed and compared the correlation functions obtained while changing the intensity of the light source in a range of 1~50 ${\mu}W$. The result shows that the radius of the focal area increases linearly through the increase of particle number and diffusion time in response to an intensity change in weak light below 10 ${\mu}W$. In the higher intensity region (>10~15 ${\mu}W$), the increasing rate of particle number and diffusion time keep increasing but at a much slower rate. Through this result, it was also found that the radius increasing rate of the focal area was reduced however, the radius still increased slightly.

Influence of Ischemic Duration on Extent of Focal Ischemic Brain Injury Induced by Middle Cerebral Artery Occlusion in Rats (백서의 중대뇌동맥 페쇄에 의한 국소 허혈성 뇌손상의 정도에 미치는 허혈 시간의 영향)

  • 구희정;정경자;김명수;진창배
    • Biomolecules & Therapeutics
    • /
    • v.8 no.2
    • /
    • pp.160-166
    • /
    • 2000
  • The present study examined influence of various ischemic duration on extent of focal ischemic brain injury induced by middle cerebral artery occlusion (MCAO) in rats. The MCAO was produced by insertion of a 17 mm silicone-coated 4-0 nylon surgical thread to the origin of MCA through the internal carotid artery for 30, 60, 90, 120 min (transient) or 24 hr (permanent) in male Sprague-Dawley rats under isoflurane anesthesia. Reperfusion in transient MCAO models was achieved by pulling the thread out of the internal carotid artery. Only rats showing neurological deficits characterized by left hemiparesis and/or circling to the left, were included in cerebral ischemic groups. The rats were sacrificed 24 hr after MCAO and seven serial coronal slices of the brain were stained with 2,3,5-triphenyltetrazolium chloride. Infarct size was measured using a computerized image analyzer. Ischemic damage was common in the frontoparietal cortex (somatosensory area) and the lateral segment of the striatum while damage to the medial segment of the striatum depended on the duration of the occlusion. In the 30-min MCAO grouts, however, infarcted region was primarily confined to the striatum and it was difficult to clearly delineate the region since there was mixed population of live and dead cells in the nucleus. Infarct volume was generally increased depending on the duration of MCAO, showing the most severe damage in the permanent MCAO group. However, there was no significant difference in infarct size between the 90-min and 120-min MCAO groups. % Edema also tended to increase depending on the duration of MCAO. The results suggest that the various focal ischemic rat models established in the present study can be used to evaluate in vivo neuroprotective activities of candidate compounds or to elucidate pathophysiological mechanisms of ischemic neuronal cell death.

  • PDF

Side lobe free medical ultrasonic imaging with application to assessing side lobe suppression filter

  • Jeong, Mok Kun;Kwon, Sung Jae
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.355-364
    • /
    • 2018
  • When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.

Focal epithelial hyperplasia arising after delivery of metal-ceramic fixed dental prosthesis

  • Park, Min-Woo;Cho, Young-Ah;Kim, Soung-Min;Myoung, Hoon;Lee, Jong-Ho;Lee, Suk-Keun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.555-558
    • /
    • 2014
  • Focal epithelial hyperplasia (FEH) is a human papillomavirus (HPV)-induced alteration of the oral mucosa that presents with a clinically distinct appearance. While other HPV-infected lesions such as squamous papilloma, verruca vulgaris, and condyloma acuminatum involve the skin, oral mucosa, and genital mucosa, FEH occurs only in the oral mucosa. The affected oral mucosa exhibits multiple papules and nodules with each papule/nodule being flat-topped or sessile. The affected region resembles the normal color of oral mucosa rather than appearing as a white color since the epithelial surface is not hyperkeratinized. Almost all cases present with multiple sites of occurrence. This rare, benign epithelial proliferation is related to low-risk HPV, especially HPV-13 and -32, and is not transformed into carcinoma. We report a case of FEH that arose on the attached gingiva of an East Asian male adult related to prosthesis without detection of any HPV subtype in HPV DNA chip and sequencing.

Feature Based Multi-Resolution Registration of Blurred Images for Image Mosaic

  • Fang, Xianyong;Luo, Bin;He, Biao;Wu, Hao
    • International Journal of CAD/CAM
    • /
    • v.9 no.1
    • /
    • pp.37-46
    • /
    • 2010
  • Existing methods for the registration of blurred images are efficient for the artificially blurred images or a planar registration, but not suitable for the naturally blurred images existing in the real image mosaic process. In this paper, we attempt to resolve this problem and propose a method for a distortion-free stitching of naturally blurred images for image mosaic. It adopts a multi-resolution and robust feature based inter-layer mosaic together. In each layer, Harris corner detector is chosen to effectively detect features and RANSAC is used to find reliable matches for further calibration as well as an initial homography as the initial motion of next layer. Simplex and subspace trust region methods are used consequently to estimate the stable focal length and rotation matrix through the transformation property of feature matches. In order to stitch multiple images together, an iterative registration strategy is also adopted to estimate the focal length of each image. Experimental results demonstrate the performance of the proposed method.

Formulating Blue Ocean Strategy to Revitalize a Regional Industry : A Case of Rafting Industry in Korea (지역산업 발전을 위한 블루오션전략 수립 : 래프팅산업에의 적용 사례)

  • Park, Kyung-Min
    • Korean Management Science Review
    • /
    • v.26 no.1
    • /
    • pp.7-20
    • /
    • 2009
  • The framework of "blue ocean strategy (Kim and Mauborgne, 2005)" applies to not only business firm level but also region or regional industry level. The paper suggests an approach of survey-based blue ocean strategy formulation. The result from survey on customer group and non-customer group gives information on positions of value curves for regions on strategy canvas and hints on how to reposition the focal region's value curve for both increases in value for customers and decreases in cost for local government, i.e., value innovation. In the context of rafting industry in Korea, this study shows the process how blue ocean strategy can be formulated with results from the survey on customers and business people in rafting industry. Relative positions of value curves on strategy canvas and importance scores for strategy elements provides the local government in region A with implications on which elements to raise or to reduce to create "blue ocean" in rafting industry under fierce inter-region competition.

Design and Construction of Hexgonal Ring-type Transducers for Ultrasonic Hyperthermia (초음파 hyperthermia용 육각환 변환기의 설계및 제작에 관한 연구)

  • Cho, Young-Hwan;Sung, Koeng-Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.4
    • /
    • pp.5-12
    • /
    • 1989
  • In the clinical application of ultrasonic hyperthermia, selective heating of tumor is essential and thus precise control of ultrasonic intensity in both tumor and normal tissue is needed. In this paper, a hexagonal array transducer for ultrasonic hyperthermia is designed and manufactured of which focal point and focal region can be ocntrolled by the digital phase control circuit proposed by authors. Profiles of the focussed ultrasound beam in water and those of temperature in phantom were determined. The experimental and computed results are in good agreement.

  • PDF

Role of phospholipase D and osteopontin in reactive glial cells after transient forebrain ischemia

  • Kim, Seong-Yun
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2000.04a
    • /
    • pp.15-16
    • /
    • 2000
  • Transient forebrain ischemia results in delayed neuronal death in the CA1 region of the hippocampus after injury, which is, at least in part, a consequence of excessive generation of reactive oxygen species. Previous in vitro studies using cell cultures or brain slices have demonstrated that phospholipase D (PLD) in the nervous system is involved in the signaling mechanism in response to a variety of agonists. Several recent studies have shown that reactive oxygen species stimulate phospholipase D (PLD) activity in several kinds of cells. Therefore, this raises the possibility that PLD activity is enhanced in the ischemic brain. Meanwhile, osteopontin (OPN) was initially identified as a sialoglycoprotein in bone, but has since been found in various tissues. Although not much is known about its function, OPN seems to play an important role in inflammation and tissue repair. Recently, it was reported that OPN was upregulated in the activated microglia after focal brain ischemia, suggesting that OPN might play a role in wound healing after a focal stroke.

  • PDF

Parametric Analysis of Digital Particle Holography for Spray Droplets (분무 액적을 위한 디지털 입자 홀로그래피의 파라미터 해석)

  • Yang, Yan;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.191-197
    • /
    • 2007
  • This study presents in-line digital particle holography and its application to spray droplets to measure the characteristics of spray droplets. Several important parameters at the time of hologram recording such as the object distance and the region of laser beam used were verified. The correlation coefficient method with important parameters such as the reconstruction interval and the correlation interval was used for determination of the focal planes of particles. The optimal values of all these parameters are obtained by either numerical simulation of holograms or experiments. Using these optimal parameters, double pulse digital spray holograms in a short time interval were recorded with the synchronization system for the time control. The spatial positions of droplets that are used for the evaluation of the three dimensional droplet velocities can be easily located, which proves the feasibility of the digital holographic technology for measurements of several important features of spray droplets.

  • PDF