• 제목/요약/키워드: flux recovery rate

검색결과 62건 처리시간 0.02초

Optimization of chemical cleaning of discarded reverse osmosis membranes for reuse

  • Jung, Minsu;Yaqub, Muhammad;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2021
  • This study optimized the chemical cleaning process of discarded RO membranes for reuse in less demanding separation processes. The effect of physicochemical parameters, including the temperature, cleaning time, pH of the cleaning solution, and addition of additives, on the cleaning process was investigated. The membrane performance was evaluated by testing the flux recovery rate and salt rejection before and after the cleaning process. High temperatures (45-50 ℃) resulted in a better flux recovery rate of 71% with more than 80% salt rejection. Equal time for acid and base cleaning 3-3 h presented a 72.43% flux recovery rate with salt rejection above 85%. During acid and base cleaning, the best results were achieved at pH values of 3.0 and 12.0, respectively. Moreover, 0.05% concentration of ethylenediaminetetraacetic acid presented 72.3% flux recovery, while 69.2% flux was achieved using sodium dodecyl sulfate with a concentration of 0.5%; both showed >80% salt rejection, indicating no damage to the active layer of the membrane. Conversely, 0.5% concentration of sodium percarbonate showed 83.1% flux recovery and 0.005% concentration of sodium hypochlorite presented 85.2% flux recovery, while a high concentration of these chemicals resulted in oxidation of the membrane that caused a reduction in salt rejection.

파일럿 규모 막 증발 공정 적용을 위한 직접 접촉식 모듈의 투과유속 및 열에너지 이동에 관한 연구 (A Study on the Flux and Heat Transfer of Direct Contact Type Module Applied for a Pilot Scale Membrane Distillation Process)

  • 김승환;김세운;이동우;조진우
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.229-236
    • /
    • 2017
  • In this study, a direct contact membrane module was manufactured to be used in a pilot scale membrane distillation process to treat $3m^3/day$ of the digestate produced from anaerobic digestion of livestock manure. In order to investigate the performance of the membrane module, permeate flux was measured with and without spacer inside the module under various condition of temperature difference and cross flow velocity (CFV) through the membrane surfaces. Flux recovery rate after chemical cleaning was also investigated by applying three different cleaning methods. Additionally, thermal energy consumption was theoretically simulated based on actual pilot plant operation conditions. As results, we observed flux of the module with spacer was almost similar to the theoretically predicted value because the installation of spacer reduced the channeling effect inside the module. Under the same operating condition, the permeate flux also increased with increasing temperature difference and CFV. As a result of chemical in-line cleaning using NaOCl and citric acid for the fouled membranes, the recovery rate was 83.7% compared to the initial flux when NaOCl was used alone, and 87% recovery rate was observed when only citric acid was used. However, in the case of using only citric acid, the permeate flux was decreased at a rapid rate. It seemed that a cleaning by NaOCl was more effective to recover the flux of membrane contaminated by the organic matter as compared to a cleaning by citric acid. The total heat energy consumption increased with increasing CFV and temperature difference across the membrane. Thus, further studies should be intensively conducted to obtain a high permeate flux while keeping the energy consumption to a minimum for a practical application of membrane distillation process to treat wastewater.

루우프형 2상 유동 열사이폰의 비등열전달 특성에 관한 연구 (A Study on the Characteristics of Boiling Heat Transfer of Two-Phase Loop Thermosyphons)

  • 조동현
    • 수산해양교육연구
    • /
    • 제26권3호
    • /
    • pp.639-646
    • /
    • 2014
  • A heat exchanger using two-phase loop thermosyphons was developed as a waste heat recovery system. An experimental study was carried out on the heat transfer characteristics of two-phase loop thermosyphons heat exchanger and the results from the experiments were used to see the possibility which the two-phase loop thermosyphons could be an alternate solution for waste heat recovery system. In the present work, R134a has been used as the working fluid and the filling rate do working fluid and heat flux have been used as the experimental parameters. The results show that the filling rate of working fluid and heat flux are very important factors for the operation of two-phase loop thermosyphons. The experimental results showed the provisional results as a waste heat recovery system.

나노여과를 이용한 Sodium Lactate의 회수 (Recovery of Sodium Lactate Using Nanofiltration)

  • 이은교;강상현;장용근;장호남
    • 한국미생물·생명공학회지
    • /
    • 제27권4호
    • /
    • pp.320-326
    • /
    • 1999
  • The effects of operating pressure, lactate concentration, impurities, and pH on solution flux and lactate rejection in nanofiltration were investigated with model sodium lactate solutions (lactate 10~200g/L) as a model system. In the tested range of pressure(80~140 psig), the solution flux was observed to be proportional to the operating pressure and the rejection of lactate increased only slightly with the pressure. Both of the flux and the rejection decreased with lactate concentration, while the recovery rate of lactate increased. The effects of glucose and yeast extract as impurities on lactate rejection were negligible, but the flux decreased significantly with the addition of yeast extract. At low lactate concentrations, the rejection of lactate increased with pH due to the increased repulsion (Donnan exclusion effect) between lactate ions and membrane surface. But, at high lactate concentrations, the donnan effect was observed to be overwhelmed by the effect of sodium ions added to adjust the pH, and the rejection of lactate decreased with pH. When fermentation broth containing about 89g/L of lactate was nanofiltered, the flux and the rejection of lactate were 2.8L/$m^2$h and 5%, respectively at 120psig. Both of them were slightly lower than those with model solutions. The recovery rate was 2.6mol/$m^2$h.

  • PDF

한외여과에 의한 다시마 정미성분 분리에 대한 연구 (Studies on the Separation of Taste Components from Sea Tangle (Laminaria japonica) Extract by Cross Flow Ultrafiltration)

  • 이호봉;이승렬;장영상;신재익
    • 한국식품과학회지
    • /
    • 제24권3호
    • /
    • pp.199-203
    • /
    • 1992
  • 한외여과를 이용하여 다시마 열수추출물로 부터 가용성 저분자량의 정미성분을 회수하는데 필요한 조건을 최적화하기 위해, 분리막 선정 및 온도, 압력, Flow rate의 영향을 고찰하였고 선정된 최적 조건하에서 한외여과와 Diafiltration을 실시하여 투과유량의 flux profile과 정미성분의 회수율을 비교하였다. 분리막은 소수성인 GR 51PP가 친수성인 FS 형태보다 높은 투과유량을 유지하였다. Flow rate의 증가에 따라서 투과유량도 증가하는 경향을 보였으나 3.7 l/min에서 한계값을 나타내었다. 한편, 압력이 높은 경우에는 Steady-state에서 투과유량이 감소하는 경향을 보였고 온도 증가에 따라서는 큰 변화는 없었다. 한외여과와 Diafiltration 실시에 따른 투과유량의 Flux profile과 전체 고형분과 정미성분의 회수율을 조사한 결과 한외여과를 실시한 경우가 비교적 높은 회수율을 보였으나 투과유량은 전반적으로 Diafiltration 보다 낮았다.

  • PDF

세라믹 막여과의 성능향상을 위한 응집 전처리의 적용 (Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration)

  • 강준석;송지영;박서경;정아영;이정준;서인석;채선하;김성수;김한승
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.

침지형 MF 중공사막을 이용한 하수 2차 처리수의 재이용 연구 (Treatment of Secondary Municipal Wastewater by Submerged Hollow Fiber MF Membranes for Water Reuse)

  • 현승훈;김응도;홍승관;안원영;임성균;김건태
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.47-52
    • /
    • 2005
  • This study was conducted to evaluate the performance of submerged hollow fiber MF processes to treat secondary wastewater for water reuse. Specifically, membrane productivity and filtrate water quality were investigated under various operating conditions (i.e. flux, recovery, and backwash rate) at pilot-scale. Membrane fouling became more severe with increasing flux and recovery, suggesting that low flux operation (< 25 LMH) was desirable. At high flux operating(> 37.5 LMH), increasing backwash rate showed only limited success. The biofouling, quantified by PEPA and BFHPC, was also significant in wastewater reclamation, and biogrowth control by chlorine, were necessary to improve membrane productivity. Filtrate water qualities are in good compliance with water reuse regulations regardless of operating conditions (flux, recovery and backwash rate). Particle (e.g. turbidity) removal ranged from 89 to 98%, while only 11 to 21% of organics (e.g. NPDOC) were removed by MF membrane. Only small improvement in biostability (e.g. AOC) was achieved by MF system, and thus, without post disinfection, significant microorganisms might be present in the filtrate due to regrowth. Lastly, in order to further investigate pathogen removal, controlled microbial challenge tests were performed by monitoring Giardia, Cryptosporidium, bacteria and virus, and showed relatively good microbial removal.

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

Cross-Flow Filtration에 의한 항생물질 생산 균사체의 분리 (Separation of Antibiotics-Producing Mycelia by Cross-Flow Filteration)

  • 정상철;윤종원
    • KSBB Journal
    • /
    • 제4권2호
    • /
    • pp.177-184
    • /
    • 1989
  • 항생물질 발효액의 균사체 분리에 있어서 Modified regenerated cellulose 막을 이용한 Cross-flow filtration으로 높은 Flux를 얻을 수 있었다. 막분리시 가급적 높은 유속, 높은 온도, 특정 균사체농도(약 20% PMV)에서 높은 Flux를 보여주었으며 Fouling 정도는 균사체 농도가 높을수록 또한 유속이 낮을수록 심각한 것으로 나타났다. 발효액을 농축 분리할 때의 Flux profile은 1단계 Sublayer형성에 의한 급속감소, 2단계 평형, 3단계 Fouling에 의한 급속감소의 세 구간으로 나눌 수 있었으며 Diafiltration의 적용으로 3단계의 Flux 감소 현상을 현저히 완화시킬 수 있었다. 한편 Diafiltration에 의한 항생물질 회수시 초기부터Diafiltration하는 것보다는 특정 PMV까지 농축시킨 후 Diafiltration하는 경우에 작업시간과 여액의 Volume을 최소화 할 수 있었으며 본 실험에서는 98%의 회수율을 얻기 위해서 Di-afiltration을 시작하는 Optimum PMV는 20%였다.

  • PDF

펜턴반응후 후처리로써 막분리에 의한 염색폐수처리 (Dyestuff Wastewater Treatment by Membrane Separation as Post-treatment after lenten막s Reaction)

  • 김선일;윤영재
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.74-80
    • /
    • 1998
  • Because permeate flux was very low as It has the suspension soled of higher concentration In the trafiltration membrane separation treatment of dyestuff wastewater, pre-treatment of Ponton reaction was carried out. In the case of pH 3, COD removal rate was the hi각erst of 58%. When PAC was added into the pre-treatment supernatant, the COD removal rate was found to be 53% , and when COD was 153mg/L, the removal rate was 92.3% in the trafiltration separation. In addition, the effect of the addition of PAC on the permeate flux was also investigated. The decrease of permeate flux In the presence of PAC was higher than In the abscence of PAC, but the recovery of permeability by cleaning was better In the case of PAC system.

  • PDF